RS232 to RS485 or RS422 line converter with isolation. >>> Distribucion: ER-Soft, S.A. Tel: <<<

Similar documents
QuidoDuplex RS. Set for bi-directional transmission of 4 or 8 two-state signals over RS485 or RS June 2011 w w w. p a p o u c h.

QuidoDuplex. Two-state signal over-ethernet transmission set based on I/O module Quido. 12. July 2017 w w w. p a p o u c h. c o m

THT2. Intelligent sensor. Humidity measuring range: 0 to 100 % Temperature measuring range: 40 to +125 C. Dew point automatic calculation

Universal RS232/CMOS to RS422/RS485 Converter

Intelligent Temperature Sensor TQS3. Measuring range -55 C to +125 C. Communication via an RS485 link

Modem RS232/RS422/RS485. to MM optic fibers. RS-232 to Multimode Optic. Fiber Converter. Characteristics DIN rail mounting.

RS-232 / 20mA Interface Converter ELO E00Q. Operation manual

CONV232/422 SERIAL DATA CONVERTER

Lecture #3 RS232 & 485 protocols

ADA User manual ADA RS-232 to RS-485 / RS-422 Converter

Concept of Serial Communication

Selection guide. Communication accessories. Communication accessory selection guide. Characteristics

The I-2532 CAN to Fiber Converter

Absolute encoder HE-65

RS 485/422 to Fibre Optic Modems ELO E243, ELO E244, ELO E245. Operation manual

TD_485 Transceiver Modules Application Guide 2017

ZCS485 User s Manual. Version ZYPEX, Inc.

ADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j.

Instruction Manual MTX-8485C MRX-8485C Four Channel Video Multiplexer with Bi-directional Data

A50/A51/A60. June 2008 (4th Edition) All Rights Reserved

MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE

Instruction Manual MTX-8485 MRX-8485 Four Channel Video Multiplexer with Bi-directional Data

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

The i-7531 CAN Repeater

Analog Module D1-15P User Manual

MD-45 AC MD-45 LV/HV INSTALLATION MANUAL

Series 2000 Reader System. Reader S251B RI-STU-251B. Reference Guide. April 2000 SCBU035

UNICOM 2500 UNICOM Installation Operation Programming. Universal Communication Converter

Instruction Manual MT-945SL Four Channel Video Transmitter With Two Bi-Directional Data Channels

Cross-Connect Interface

af i Instruction Manual MR-944C Four Channel Video Receiver With One Bi-Directional Multi-Protocol Data Channel american fibertek 11/30/2012 JPK

ADAM Isolated DC Input/Output Signal Conditioning Module. User s Manual

Serial Communications RS232, RS485, RS422

Data Acquisition Modules/ Distributed IO Modules

I-2533CS series User Manual

Modem 9600 baud 500FSD11 EDS500 series - FSK modems

Instruction Manual RT-93285SL RR-93285SL Thirty-two Channel Video Multiplexer With Two Bi-directional Data Channels

RS-232 Electrical Specifications and a Typical Connection

Integrity Instruments

Z-10-D-IN. RS485 Modbus Module 10 Digital Inputs

Ultrasonic Multiplexer OPMUX v12.0

SERIAL COMMUNICATION. IDTECK Home e-training Center Home Product Catalog Product Manual Troubleshooting Purchase Order

Miniature Synchronous Multipoint Modems

Data transmission. 4.1 Optical transmission 173

Universal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485

RM24100D. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

LASER. Analog Laser Displacement Transducer. LAM Series. Key-Features: Content:

M-Bus Master MultiPort 250L Installation and User Guide

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

Instruction Manual MX-480 Bi-directional Multi-Protocol Data

HR1200. Version 1.00 ATIM RADIOCOMMUNICATION 1/11

APPLICATION BULLETIN. SERIAL BACKGROUNDER (Serial 101) AB23-1. ICS ICS ELECTRONICS division of Systems West Inc. INTRODUCTION CHAPTER 2 - DATA FORMAT

Modem 1200 baud 500FSD10 EDS500 series - FSK modems

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

Serial Input/Output. Lecturer: Sri Parameswaran Notes by: Annie Guo

Dual Protocol Transceivers Ease the Design of Industrial Interfaces

XIOC technology and networking modules

USING RS-232 to RS-485 CONVERTERS (With RS-232, RS-422 and RS-485 devices)

Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter

AR-DN-RS232. An-10 / Rapid RS232 Interface. Product Guide. Overview. Features

GSM/GPRS/GPS Tracker GV100. User Manual TRACGV100UM001. Revision: Quectel Wireless Solutions

Instruction Manual MX-485-S Bi-directional RS485 Data Transceiver

EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442

Interface converter RS-232 / RS-485 TECHNICAL GUIDE. Review date: 9 Jun 2010 TECHNOTRADE LTD

USER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

ies-2309 Integrated Easy Servo

Model 4xx. Plug-in Series Of FSK Modems USER GUIDE. (TI) 20 Jan 06 DWG: A GDI COMMUNICATIONS LLC PO Box I-80 Exit 1 Verdi, NV 89439

1 FUNCTIONAL DESCRIPTION WAY SPLITTER/INPUT BOARD FET RF AMPLIFIERS WAY POWER COMBINER VSWR CONTROL BOARD...

RM24100D. Introduction. Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

Appendix C RS-485 Network

Nokeval. Operators manual. Signal converter 641. No P

2070-6A Manual A Manual. Dual 1200 baud Modem For The 2070 Controller GDI A MANUAL

SICLOCK DCFRS Industrial Version with TTY Interface 2XV9450-1AR21

POSICHRON position sensor in stick design. Protection class. Voltage: V, 3 wire Current: ma, 3 wire

There are many important factors when trying to achieve good, reliable communications between 2 devices.

Thermo Electric Cooling Temperature Controller TEC Controller / Peltier Driver ±16 A / ±19 V

SRWF-1021 Series Low Power Wireless Transceiver Data Module User Manual

Since 1987 Developed, Created and Made in Spain NDV6/ND6V VIDEO & DATA TRANSCEIVER, AUDIO & CONTACT

Technical description MT24. User manual WARNING GENERAL INSTRUCTIONS GENERAL DESCRIPTION

Programmable RS-232/RS-485 Transceiver

INSTRUCTION MANUAL MODEL 2779 SUBCARRIER MODULATOR

Revision WI.232FHSS-25-FCC-R and RK-WI.232FHSS-25-FCC-R USER S MANUAL

Protection Class (IEC 529)

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

HD 48V01T... HD 4977T...

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

IQ SENSOR NET MIQ/MC(-A)-RS

2070-6B Manual B Manual. Dual 9600 baud Modem For The 2070 Controller. GDI B Manual. Rev B

Brushed DC Motor Control. Module with CAN (MDL-BDC24)

CONTROL MICROSYSTEMS SCADAWave Radio Transceiver. Hardware Manual

3DM phase Digital Stepper Drive

A local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires.

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION MD-45 AC MD-45 LV/HV

RM24100A. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

Answering frequently asked Questions (Firmware V.107)

Characteristics and functioning

SA-320 Installation Guide SA-320. Installation Guide. Date: June, 2007 Version: 2.2. All Rights Reserved

Industrial Systems Design & Implementation

CSG110 Strain Gauge Universal Amplifier

JZ878 RF Data Radio. User s Manual

Transcription:

RS232 <> RS485/422 RS232 to RS485 or RS422 line converter with isolation >>> Distribucion: ER-Soft, S.A. www.er-soft.com info@er-soft.com Tel: +34 916-408-408 <<< 8/30/2005 w w w. p a p o u c h. c o m 0004

Datasheet Created: 5/4/2005 Last update: 5/19/2005 9:15 Number of pages: 16 2005 Address: Sobeslavska 15 130 00 Prague 3 Czech Republic Tel: +420 267 314 268-9 +420 602 379 954 Fax: +420 267 314 268-9 Internet: www.papouch.com E-mail: info@papouch.com >>> Distribucion: ER-Soft, S.A. www.er-soft.com info@er-soft.com Tel: +34 916-408-408 <<< Page 2 Sobeslavska 15, Prague 3, tel.: +420 267 314 268 www.papouch.com

TABLE OF CONTENTS Description...4 Features...4 Installing options...4 Technical Parameters...5 General...5 Connector pins...5 Settings...6 Modes...6 Line termination and idle mode...7 Automatic control settings...7 Installation for the RS485/422 line...9 Installation for the RS422 line...11 RS232 line extension...12 RS485 and RS422 lines...13 Possible problems during installation...15 Fig. 1 Principal diagram of isolation >>> Distribucion: ER-Soft, S.A. www.er-soft.com info@er-soft.com Tel: +34 916-408-408 <<< www.papouch.com Sobeslavska 15, Prague 3, tel.: +420 267 314 268 Page 3

DESCRIPTION The module converts an RS232 line to RS485 or RS422. The module settings can be set with the aid of switches, as described below. The green LED indicates that the module is ON; the yellow indicators show the RxD and TxD status. FEATURES Lines can be set: RS485, RS422, and RS422 multimaster Transmission speed up to 480 kbd Direction control on the RS485 line can be automatic or by DTR signal (whose polarity can be set) The RS485/422 line (including the grounding) is completely isolated from RS232 and from the power supply (this isolation is provided as standard for all types) Optionally, grounding of the power supply and grounding of the RS232 line can be isolated from each other The RS485/RS422 line is over voltage protected The ON and data flow statuses are indicated by LED indicators the unit activation is easy A built-in optional termination, including resistors which define the line's idle status Power supply 7 to 40 V (depending on the type, also 36 to 75 V or 5 V) D-SUB 9 connectors or a slip-on termination board Dimensions 105 55 24 mm, optionally secured to a DIN strip INSTALLING OPTIONS Holder: Without a DIN rail holder (standard) With a DIN rail holder Power supply: 7 to 40 V 1 (standard configuration) 5 V ±10% 1,2 4.5 V ±10% 2,3 9 V ±10% 2.3 18 V to 36 V 2.3 RS485/422 connection: D-SUB 9M (type C) Slip-on terminal board (type S) Fig. 2 S 36 V to 75 V 2.3 Please do not hesitate to contact us if you have specific requirements for the module's configuration and functionality. 1 The RS485/422 line (including the grounding) is completely conductively separated from RS232 and from the power supply (G1 separation cf. Fig. 1). The power supply and the RS232 line have common grounding. 2 The time limit for delivery of this configuration is between one and three weeks. 3 The RS232 line's grounding is conductively separated from the power supply's grounding (cf. Fig. 1 to see the G2 separation). Page 4 Sobeslavska 15, Prague 3, tel.: +420 267 314 268 www.papouch.com

TECHNICAL PARAMETERS G e n e r a l Power supply voltage...7 V to 40 V (optionally, 4.5 75 V) with protection from polarity reversal Power supply connector...slip-on connector board Isolation...1,000 V Maximum transmission speed...480 kbd Operating temperature... 20 C to +70 C RS485/422: Terminal resistors...120 Ω Resistors which define the idle status...680 Ω Maximum number of connected devices...31 Voltage overprotection...yes, 12 V bipolar transil diodes C connection...d-sub 9M S...slip-on connector board RS232: Voltage overprotection...15 kv Connection...D-SUB 9M C o n n e c t o r p i n s Fig. 3 RS232 pins Fig. 4 - RS485/422 pins on C 1 6 Pin Description 1 U OUT (5V/15mA) 2 GND 3 Tx+/RxTx+ 4 Tx-/RxTx- 5 Rx+ 6 Rx- Fig. 5 Power supply connector Fig. 6 RS485/422 pins on S www.papouch.com Sobeslavska 15, Prague 3, tel.: +420 267 314 268 Page 5

SETTINGS M o d e s The communication modes are set by switches on the front panel. Fig. 7 Front panel switches, module (they are all OFF in this figure) RS485 RS422 RS422 Multimaster SW3 SW4 SW7 SW8 Mode OFF ON OFF OFF OFF OFF OFF ON OFF OFF ON OFF ON OFF OFF OFF ON ON OFF OFF ON OFF OFF ON ON OFF ON OFF Automatic control When transmitting data from RS232 to RS485, the converter is automatically switched to transmission. Upon completion of the transmission, it is switched to receipt after a short delay. The duration of this delay can be set according to Table 2 on page 8. DTR control Transmission to the RS485 line is controlled by positive polarity of the DTR signal on the RS232 line. DTR control Transmission to the RS485 line is controlled by negative polarity of the DTR signal on the RS232 line. Standard RS422 Bidirectional ("full duplex") communication; the output line driver is connected all the time. Automatic control multimaster When transmitting data from RS232 to RS422, the converter is automatically switched to transmission. Upon completion of the transmission, it is disconnected after a short delay. The duration of this delay can be set according to Table 2 on page 8. DTR control multimaster Transmission to the RS422 line is controlled by positive polarity of the DTR signal on the RS232 line. DTR control multimaster Transmission to the RS422 line is controlled by negative polarity of the DTR signal on the RS232 line. Table 1 Settings of the communication line modes Page 6 Sobeslavska 15, Prague 3, tel.: +420 267 314 268 www.papouch.com

L i n e t e r m i n a t i o n a n d i d l e m o d e TERM485 This device connects the impedance termination of the RS485 or RS422 line on the transmitter's side. It prevents signal from reflection at the line ends. These resistors should be connected at both ends of the communication line. TERM422 This device connects the impedance termination of the RS422 line on the receiver's side. It prevents signal from reflection at the line ends. These resistors should be connected at both ends of the communication line. BIAS485 This device connects the resistors which define the idle mode of the RS485 or RS422 line on the transmitter's side. They determine the idle-status levels of the communication line. (More detailed information can be found in the section "Idle mode" on page 10.) A u t o m a t i c c o n t r o l s e t t i n g s When automatic (time) control is used for the RS485 or RS422 line, the value T of the time delay can be set, for which the driver remains switched to transmission. Fig. 8 Time delay for which the driver remains switched to transmission The default value of this delay is 460 μs; it can be changed using jumpers inside of the module. First open the module case. Unscrew the two screws (opposite to each other) on the module case's bottom side, loosen the screws on the top lid, and tilt the top lid out. Fig. 9 Locations of the screws securing the top lid www.papouch.com Sobeslavska 15, Prague 3, tel.: +420 267 314 268 Page 7

There are four jumpers inside. SW1 SW2 SW3 SW4 Fig. 10 Jumpers for setting the time delay value The jumpers' configuration defines the time delay value T. The default value of this delay is 460 μs; it can be changed using jumpers inside of the module. The configurations and their meanings are shown in the Table below. SW1 SW2 SW3 SW4 Delay value Recommended for speed OFF OFF OFF OFF 1.9 ms < 19,200 Bd ON OFF OFF OFF 460 μs 19,200 or 38,400 Bd (factory default) OFF ON OFF OFF 140 μs 57,600 or 115,200 Bd OFF OFF ON OFF 33 μs OFF OFF OFF ON 9 μs OFF OFF ON ON 7 μs Table 2 Time delay value setting Page 8 Sobeslavska 15, Prague 3, tel.: +420 267 314 268 www.papouch.com

I n s t a l l a t i o n f o r t h e R S 4 8 5 / 4 2 2 l i n e The following steps are used for the converter installation for communication on an RS485 line: 1) Set the switches SW3 through SW8 according to Table 1 on page 6. 2) Connect the RS485 wires to the D-SUB 9M connector according to Table 3. (Cf. the connector diagram on page 5.) Wire D-SUB 9M pin Slip-on connector Comment RxTx+ (A) 7 3 RxTx- (B) 6 4 SGND 5 2 Table 3 RS485 line connection grounding of signal 3) Connect the RS232 wires to the D-SUB 9F connector according to Table 4 using an uncrossed cable. Wire RS232 connection on PC D-SUB 9F D-SUB 9 D-SUB 25 TxD 3 3 2 Comment Data transmitted from a PC RxD 2 2 3 Data received to a PC GND 5 5 7 grounding of signal DTR 4 or RTS 4 4 20 7 4 direction control Table 4 RS485 line connection 4) If the converter is at a line endpoint, the termination resistors should to be connected by a TERM485. Switches consider connection of resistors which define the idle status. 5) Connect to the power supply. 1 The DTR or RTS signal is only used within modes with the DTR line control. The mode settings are described on page 6 under "Modes". www.papouch.com Sobeslavska 15, Prague 3, tel.: +420 267 314 268 Page 9

Idle mode When communicating on the RS485 line or the RS422 multimaster line, there may be a notransmission status (all lines are in the receiving mode). In this case, the status of the line is undefined and it is extremely sensitive to any induced voltage (interference), which is deemed incoming signals. Therefore an idle mode should be defined by connecting suitable resistors to a line. If the line is long, the best point is at the end-of-line modules or equipment. Fig. 11 Connection of resistors which define the idle mode With the converter, built-in resistors can be used, connected by the BIAS485 switches; or the resistors may be connected directly to the RS485 connector (cf. Fig. 11). For long lines, the resistor values should be higher and the termination should be connected simultaneously. SGND can also be used for connection of the cable shielding contact. Page 10 Sobeslavska 15, Prague 3, tel.: +420 267 314 268 www.papouch.com

I n s t a l l a t i o n f o r t h e R S 4 2 2 l i n e The following steps are used for the converter installation for communication between two devices on an RS422 line: 1) Set the switches SW3 through SW8 according to Table 1 on page 6. 2) Connect the RS422 leads to the D-SUB 9M connector according to Table 5 (a drawing of the connectors is on page 5). Wire D-SUB 9M pin Slip-on connector board Comment Tx+ (A) 7 3 Tx- (B) 6 4 Rx+ (A ) 9 5 Rx- (B ) 8 6 SGND 5 2 grounding of signal Table 5 RS422 line connection 3) Connect the RS232 leads to the D-SUB 9F connector according to Table 6 using an uncrossed cable. Wire RS232 connection to PC D-SUB 9F D-SUB 9 D-SUB 25 TxD 3 3 2 Comment Data transmitted from a PC RxD 2 2 3 Data received to a PC GND 5 5 7 grounding of signal DTR or RTS 5 4 4 20 7 4 disconnection of exciter Table 6 RS232 line connection 4) If the converter is at a line endpoint, the termination resistors are to be connected by the TERM422. For the multimaster mode, consider connection of resistors which define the idle status. 5) Connect to the power supply. 5 The DTR or RTS signal is only used within modes with the DTR line control. The mode settings are described on page 6 under "Modes". www.papouch.com Sobeslavska 15, Prague 3, tel.: +420 267 314 268 Page 11

R S 2 3 2 l i n e e x t e n s i o n By using two, you can extend an RS232 line to a distance of up to 1,200 m. 6 1) Connect the RS232 line and the power supply to the converters on both ends. 2) Both converters should be set to the RS422 mode according to the above-mentioned instructions. 3) Connect the cable between the converters according to Table 7 (a drawing of the connectors is on page 5). (S) Opposite (S) 7 (3) 9 (5) 6 (4) 8 (6) 9 (5) 7 (3) 8 (6) 6 (4) Table 7 RS232 extension line connection 6 An RS232 line can also be extended with the aid of a special LD232 set. Page 12 Sobeslavska 15, Prague 3, tel.: +420 267 314 268 www.papouch.com

RS485 AND RS422 LINES An RS485 line consists of a pair of wires, denoted by symbols RxTx+ and RxTx- 7, preferably by a twisted pair. In the idle mode, the RxTx+ wire's potential is more positive than that of RxTx-. The topology is a stem line with short branches. Impedance termination devices should be connected at both ends of the stem line. The RS485 line is a half-duplex bus: data is sent and received on the same wires. Therefore the communication direction must be switched between transmission and receipt. Fig. 12 An example of a system with an RS485 line interconnection. Termination is connected in Modules 1 and 5. The DTR signal of the RS232 line can be used for the direction control, or automatic (time) control can be used. Fig. 13 An example of a system with an RS422 line interconnection. Termination is connected in both modules. 7 Notation A (for RxTx+) and B (for RxTx ) is sometimes used. www.papouch.com Sobeslavska 15, Prague 3, tel.: +420 267 314 268 Page 13

Fig. 14 An example of a system with an RS422 line interconnection in the multimaster mode. An RS422 line consists of two symmetric pairs of conductors. It is duplex line and directly substitutes the RxD and TxD signals of the RS232 lines; one pair is used for data receipt, the other pair for transmission. The transmission conductors are denoted by symbols Tx+ and Tx-; the receipt pair are denoted Rx+ and Rx-. In the idle mode, the + wire s potential is more positive than the wire. Impedance terminations are connected to the line endpoints. An RS422 line can have branches; in this case, transmitters must be disconnected mode Multimaster must be set according Table 1. Page 14 Sobeslavska 15, Prague 3, tel.: +420 267 314 268 www.papouch.com

POSSIBLE PROBLEMS DURING INSTALLATION Recognising RxTx+ and RxTx- conductors: In the idle mode of an RS485 (RS422) line, the RxTx+ conductor's potential is more positive than that of RxTx-. Before measuring, we must ensure that the equipment at the other endpoint is a transmitter and either idle or sending data with a very low frequency of occurrence. If the polarity of the RxTx+ and RxTx- conductors is correct, the yellow RxD indicator must be on when data is transmitted (test it when the control signal is off and the "positive control signal during transmission" option is set). Even thought the power supply is switched on, the green indicator is off: Make sure that power supply is on, the power supply voltage is accordant with converter installing option and polarity is not reversed. The RxD remains on even if no data is being transmitted: There may be several causes of this defect: The RxTx+ and RxTx- conductors of the RS485 line may be mutually interchanged. An impedance termination on the receiver side is connected, but there are no resistors which would define the line's idle mode. The impedance termination is connected to the module. On the opposite side, resistors are connected which define the line's idle mode. However, the line or one of its wires is broken. >>> Distribucion: ER-Soft, S.A. www.er-soft.com info@er-soft.com Tel: +34 916-408-408 <<< www.papouch.com Sobeslavska 15, Prague 3, tel.: +420 267 314 268 Page 15

Data transmission in industry, line and protocol conversions, RS232/485/422/USB/Ethernet/GPRS/ WiFi, measurement modules, intelligent temperature sensors, I/O modules, and custommade electronic applications. Address: Sobeslavska 15 130 00 Prague 3 Czech Republic Tel: +420 267 314 268-9 +420 602 379 954 Fax: +420 267 314 268-9 Internet: www.papouch.com E-mail: info@papouch.com >>> Distribucion: ER-Soft, S.A. www.er-soft.com info@er-soft.com Tel: +34 916-408-408 <<< w w w. p a p o u c h. c o m