Crossed-Field Amplifier (Amplitron)

Similar documents
Magnetron. Physical construction of a magnetron

Lecturer Note. Lecturer-29

Module IV, Lecture 2 DNP experiments and hardware

Highly efficient water heaters using magnetron effects

Dhanalakshmi College of Engineering Department of ECE EC6701 RF and Microwave Engineering Unit 4 Part A

Navy Electricity and Electronics Training Series

PRODUCT AND CAPABILITY SUMMARY

SIMULATION OF A MAGNETRON USING DISCRETE MODULATED CURRENT SOURCES. Sulmer A. Fernández-Gutierrez. A dissertation. submitted in partial fulfillment

CHAPTER 4 TRANSMITTERS. T. A. Weil Equipment Division Raytheon Company

6 Experiment II: Law of Reflection

3. (a) Derive an expression for the Hull cut off condition for cylindrical magnetron oscillator. (b) Write short notes on 8 cavity magnetron [8+8]

GT-1000A Microwave Power Amplifier 2 GHz to 20 GHz. Broadband High-Power Instrumentation Amplifier. Preliminary Technical Datasheet

EC 1402 Microwave Engineering

X band Magnetron. Water: Anode cavity Forced-air: Input ceramics and terminals Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent

Figure Cutaway view of the Phasitron tube, which is used as the modulator and upon which the operation of the GE f-m transmitter is based.

St.MARTIN S ENGINEERING COLLEGE Dhulapally, Secunderabad

MAGNETRON DEVELOPMENT. R.R.Moats

Technical Datasheet GT-1000B Microwave Power Amplifier. 100 MHz to 20 GHz. Broadband High-Power Instrumentation Amplifier Rev.

...the power in microwaves! MICROWAVE TUBES. product summary MICROWAVE TUBES.

X-band Magnetron. Cooling (note 5) Water Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent

ECRH on the Levitated Dipole Experiment

SIMULATION OF A MAGNETRON USING DISCRETE MODULATED CURRENT SOURCES. Sulmer A. Fernández Gutierrez. A dissertation. submitted in partial fulfillment

QUESTION BANK SUB. NAME: RF & MICROWAVE ENGINEERING SUB. CODE: EC 2403 BRANCH/YEAR/: ECE/IV UNIT 1 TWO PORT RF NETWORKS- CIRCUIT REPRESENTATION


Satellite Sub-systems

Lecture - 19 Microwave Solid State Diode Oscillator and Amplifier

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

Microwave capability. Delivering precision effects. e2v.com

R.K.YADAV. 2. Explain with suitable sketch the operation of two-cavity Klystron amplifier. explain the concept of velocity and current modulations.

Technical Datasheet GT-1050B Microwave Power Amplifier. 2 GHz to 50 GHz. Broadband High-Power Instrumentation Amplifier Rev.

PRINCIPLES OF RADAR. By Members of the Staff of the Radar School Massachusetts Institute of Technology. Third Edition by J.

. From the above data, determine the network is symmetric or not.

S-band Magnetron. Tuner revolutions to cover frequency range 4.75 (note 3) Mounting position (note 4) Any Cooling (note 5) Water

8984 Power Tube. VHF Linear Beam Power Tube

Impulse Response as a Measurement of the Quality of Chirp Radar Pulses

6.3 - Velocity Modulated Tubes: Magnetron Tubes

Thirteenth Edition Copyright 2007 L-3 Communications Electron Technologies, Inc.

9007 Power Tube. VHF Linear Power Amplifier Tube 33 Kilowatt Peak Sync Output Thru VHF-TV Band

Passive Phased Arrays for Radar Antennas

Experiment-4 Study of the characteristics of the Klystron tube

This place covers: Demodulation or transference of signals modulated on a sinusoidal carrier or on electromagnetic waves.

ABSOLUTE MAXIMUM RATINGS These ratings cannot necessarily be used simultaneously and no individual ratings should be exceeded.

Development Activity of Terahertz Power Amplifiers -W-band to 300GHz-

Tendencies in the Development of High-Power Gyrotrons

MAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI UNIT III TUNED AMPLIFIERS PART A (2 Marks)

ELEC4604. RF Electronics. Experiment 2

Stanford Linear Accelerator Stanford University, Stanford, CA ABSTRACT

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, MAGNETRON TYPE 8943

8121 Power Tube. Linear Beam Power Tube

8807 Power Tube. Beam Power Tube

OF MICROWAVE OSCILLATORS

10 GHz Microwave Link

RECOMMENDATION ITU-R M.1314* REDUCTION OF SPURIOUS EMISSIONS OF RADAR SYSTEMS OPERATING IN THE 3 GHz AND 5 GHz BANDS (Question ITU-R 202/8)

A 94 GHz Overmoded Traveling Wave Tube (TWT) Amplifier

COOPERATIVE PATENT CLASSIFICATION

Models 1421 and 1422 User s Manual. Broadband Amplifiers

Solid-State Upgrade for the COBRA JUDY S-Band Phased Array Radar

E2V Technologies M5187F X-Band Magnetron

High Frequency Gyrotrons and Their Applications

Experimental Plan for Testing the UNM Metamaterial Slow Wave Structure for High Power Microwave Generation

MG7095 Tunable S-Band Magnetron

July 2009 Vol. 32 No. 7. Advancing TWT. Also in this issue: Technology Survey: COMINT/DF Receivers

MICROWAVE ENGINEERING LAB VIVA QUESTIONS AND ANSWERS

FLASH rf gun. beam generated within the (1.3 GHz) RF gun by a laser. filling time: typical 55 μs. flat top time: up to 800 μs

HITACHI Proton Therapy System with Spot Scanning

Gyroklystron Research at CCR

PowerMAX Redundant SSPA Systems. Soft-fail Redundancy Modular, Hot-swap Assemblies Indoor and Outdoor Packages

Predictions of LER-HER limits

Technical Note

Continuous Wave Radar

-31- VII. MAGNETRON DEVELOPMENT. Prof. S. T. Martin V. Mayper D. L. Eckhardt R. R. Moats S. Goldberg R. Q. Twiss

Developme nt of Active Phased Array with Phase-controlled Magnetrons

Investigation of Spatial Harmonic Magnetrons for High Power Millimetre and THz Wave Operations

8988 Power Tube. Linear Beam Power Tube

Normal-conducting high-gradient rf systems

Power-stabilization of high frequency gyrotrons using a double PID feedback control for applications to many high power THz spectroscopy

Continental's 816R -5B, 35 kw Single Tube Broadcast Transmitter. Includes the 802A solid -state exciter

DEPARTMENT OF ELECTRONICS AND COMMUNICATION ENGINEERING QUESTION BANK SUBJECT NAME & CODE: EC2403 & RF AND MICROWAVE ENGINEERING UNIT I

Chapter 8. Wavelength-Division Multiplexing (WDM) Part II: Amplifiers

SRM UNIVERSITY FACULTY OF ENGINEERING AND TECHNOLOGY SCHOOL OF ELECTRONICS AND ELECTRICAL ENGINEERING DEPARTMENT OF TCE COURSE PLAN

Optodevice Data Book ODE I. Rev.9 Mar Opnext Japan, Inc.

The Basics of Travelling Wave Tube Amplifiers SCM01

M5187 X-Band Magnetron

Aviation Electricity and Electronics Radar

FREQUENCY -SHIFT. maintains radiation at full power, but the carrier is shifted back and

Frequency Diversity Radar

Sonic Distance Sensors

Chapter 6: Power Amplifiers

MICROWAVE MICROWAVE TRAINING BENCH COMPONENT SPECIFICATIONS:

Project of RF System for 2.2 GeV Electron Storage Ring Zelenograd SR Source.

Introduction to ixblue RF drivers and amplifiers for optical modulators

egkjk.kk izrki ih-th- dkyst] taxy /kwlm+] xksj[kiqj

waveguides. Figure 16. Strapping in a magnetron to obtain a mode. Figure 17. Cylindrical and rectangular

Design considerations for the RF phase reference distribution system for X-ray FEL and TESLA

Transmitter Tetrode TH 347

Radio Receivers. Al Penney VO1NO

Fast start of oscillations in a short-pulse relativistic magnetron driven by a transparent cathode.

Latest Control Technology in Inverters and Servo Systems

MG5193 Tunable S-Band Magnetron

Tuned Radio Frequency Receiver (TRF) The most elementary receiver design, consisting of RF amplifier stages, detector and audio amplifier stages.

Transcription:

Crossed-Field Amplifier (Amplitron) Figure 1: water-cooled Crossed-Field Amplifier L 4756A in its transport case Figure 2: Subset of the cycloidal electron paths into a Crossed-Field Amplifier Also other names are sometimes used for the Crossed-Field Amplifier in the literature.

Platinotron Amplitron Stabilotron The Crossed-Field Amplifier (CFA), is a broadband microwave amplifier that can also be used as an oscillator (Stabilotron). It is a so called Velocitymodulated Tube. The CFA is similar in operation to the magnetron and is capable of providing relatively large amounts of power with high efficiency. In contrast to the magnetron, the CFA have an odd number of resonant cavities coupled with each other. These resonant cavities work to as a slowwave structure: an oscillating resonant cavity excites the next cavity. The actual oscillation will be lead from the input waveguide to the output waveguide. The electric and magnetic fields in a CFA are perpendicular to each other ( crossed fields ). Without an input signal and the influence of both the electric field (anode voltage) and the magnetic field (a strong permanent magnet) all electrons will move uniformly from the cathode to the anode on a cycloidal path as shown in figure 2. (This case should be avoided in practice, because the CFA will generate a high level of noise then.) Figure 3: The input signal starts the excitation of the first resonant cavity

If the input-waveguide introduces an oscillation into the first resonator (as shown in figure 3), the vanes of the resonator gets a voltage difference synchronously to the oscillation. Under the influence of this additionally field flying past electrons get acceleration (at the positively charged vane) or they are decelerated (at the negatively charged vane). This causes a difference in speed of the electrons. The faster electrons catch the slower electrons and the forms electron bunches in the interaction space between the cathode and the anode. These bunches of electrons rotates as like as the Space- Charge Wheel known from the magnetron operation. But they cannot rotate in full circle, the Space-Charge Wheel will be interrupted because the odd number of cavities causes an opposite phase in the last odd cavity (this bottom one between the waveguides). To avoid a negative feedback, into this resonant cavity may exist a bloc containing graphite to decouple input and output.) The oscillation is still very weak into the first cavity. But the electron bunches will hit the vanes of the following cavities and will dispense their energy synchronously to the oscillation. The alternating microwave field causes the electrons to alternately speed up and slow down near the next cavity. Simultaneously, the anode near the vanes is hit of the first electrons in cycle of oscillation. This causes amplification: the oscillation will be stronger from cavity to cavity therefore. At the resonant cavity with the coupled output-waveguide these electron bunches are solved: all but electrons hit the anode and causes the anode current. The bandwidth of the CFA, at any given instant, is approximately plus or minus 5 percent of the rated center frequency. Any incoming signals within this bandwidth are amplified. Peak power levels of many megawatts and average power levels of tens of kilowatts average are, with efficiency ratings in excess of 70 percent, possible with crossed-field amplifiers. To avoid ineffective modes of operation the construction of CFA contains strapping wires like to as used in magnetrons. Because of the desirable characteristics of wide bandwidth, high efficiency, and the ability to handle large amounts of power, the CFA is used in many applications in microwave electronic systems. When used as the intermediate or final stage in highpower radar systems, all of the advantages of the CFA are used.

Figure 4: Interaction between a cavity resonator and the rotating Space- Charge Wheel Figure 5: The interrupted Space-Charge Wheel into a Crossed-Field Amplifier The amplifiers in this type of power-amplifier transmitter must be broadband microwave amplifiers that amplify the input signals without frequency distortion. Typically, the first stage and the second stage are traveling-wave

tubes (TWT) and the final stage is a crossed-field amplifier. Recent technological advances in the field of solid-state microwave amplifiers have produced solid-state amplifiers with enough output power to be used as the first stage in some systems. Transmitters with more than three stages usually use crossed-field amplifiers in the third and any additional stages. Both traveling-wave tubes and crossed-field amplifiers have a very flat amplification response over a relatively wide frequency range. Crossed-field amplifiers have another advantage when used as the final stages of a transmitter; that is, the design of the crossed-field amplifier allows rf energy to pass through the tube virtually unaffected when the tube is not pulsed. When no pulse is present, the tube acts as a section of waveguide. Therefore, if less than maximum output power is desired, the final and preceding cross-field amplifier stages can be shut off as needed. This feature also allows a transmitter to operate at reduced power, even when the final crossed-field amplifier is defective. If the anode voltage is switched on then the CFA will provide a gain of 3 to 20 db. Note: William C. Brown's work on adapting magnetron principles to create a new broadband amplifier resulted in the Amplitron, a trademark of the Raytheon Manufacturing Company for the Raytheon line of crossed-field amplifiers today. Source: http://www.radartutorial.eu/08.transmitters/crossed- Field%20Amplifier%20%28Amplitron%29.en.html