This is a postprint version of the following published document:

Similar documents
This is a postprint version of the following published document:

Diffraction grating-based demultiplexers for SI-POF networks

D DAVID PUBLISHING. POF over WDM Beyond the Dispersion Limit. 1. Introduction. U. H. P. Fischer 1, S. Höll 2, M. Haupt 1 and M.

Presentation Overview

An Amplified WDM-PON Using Broadband Light Source Seeded Optical Sources and a Novel Bidirectional Reach Extender

CWDM self-referencing sensor network based on ring resonators in reflective configuration

2006 International Students and Young Scientists Workshop Photonics and Microsystems. Demultiplexers.

Microwave and Optical Technology Letters. Minhui Yan, Qing-Yang Xu 1, Chih-Hung Chen, Wei-Ping Huang, and Xiaobin Hong

WWDM Transceiver Module for 10-Gb/s Ethernet

Compact two-mode (de)multiplexer based on symmetric Y-junction and Multimode interference waveguides

Visible to infrared high-speed WDM transmission over PCF


Dr. Monir Hossen ECE, KUET

Selection of Spectral Filters for Optical Demultiplexer Via Same Source Different Filters Testing Technique

In-home networks integrating high-capacity DMT data and DVB-T over large-core GI-POF

Frequency Domain LED Compensation for Nonlinearity Mitigation in DMT Systems

Colorless Amplified WDM-PON Employing Broadband Light Source Seeded Optical Sources and Channel-by-Channel Dispersion Compensators for >100 km Reach

A novel tunable diode laser using volume holographic gratings

Mahendra Kumar1 Navneet Agrawal2

Why Using Fiber for transmission

Integrated TOSA with High-Speed EML Chips for up to 400 Gbit/s Communication

Opto-VLSI-based reconfigurable photonic RF filter

CWDM Cisco CWDM wavelengths (nm)

UNIVERSITY OF TORONTO FACULTY OF APPLIED SCIENCE AND ENGINEERING. FINAL EXAMINATION, April 2017 DURATION: 2.5 hours

Enabling Devices using MicroElectroMechanical System (MEMS) Technology for Optical Networking

Evolution from TDM-PONs to Next-Generation PONs

Performance Analysis Of An Ultra High Capacity 1 Tbps DWDM-RoF System For Very Narrow Channel Spacing

11.1 Gbit/s Pluggable Small Form Factor DWDM Optical Transceiver Module

Published in: Proceedings of the 15th International Conference on Optical Network Design and Modeling (ONDM), 8-10 February 2011, Bologna, Italy

FMU-MC09-A/B, Pair Packaged DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET FMU-MC04E-A/B, Pair Packaged, w/expansion Port

Long-wavelength VCSELs ready to benefit 40/100-GbE modules

Innovations in Photonic Integration Platforms

Improved Analysis of Hybrid Optical Amplifier in CWDM System

Hybrid Integration Technology of Silicon Optical Waveguide and Electronic Circuit

Emerging Subsea Networks

Optical Fiber Technology

Introduction of 25 Gb/s VCSELs

Module 19 : WDM Components

Adaptive multi/demultiplexers for optical signals with arbitrary wavelength spacing.

Available online at ScienceDirect. The 4th International Conference on Electrical Engineering and Informatics (ICEEI 2013)

SIMULATIVE INVESTIGATION OF SINGLE-TONE ROF SYSTEM USING VARIOUS DUOBINARY MODULATION FORMATS

A High-Speed Bi-Directional Visible Light Communication System Based on RGB-LED

International Journal of Advanced Research in Computer Science and Software Engineering

This is a paper submitted to and accepted for publication in:

Fast, Two-Dimensional Optical Beamscanning by Wavelength Switching T. K. Chan, E. Myslivets, J. E. Ford

WaveSmart Wave Division Multiplexing (WDM)

Datasheet. FMU-MC04-A/B, Pair Packaged 4 Channels Single Fiber CWDM Mux Demux, Plug-in Module, LC/UPC. Overview. Highlights

Spectrally Compact Optical Subcarrier Multiplexing with 42.6 Gbit/s AM-PSK Payload and 2.5Gbit/s NRZ Labels

System demonstrator for board-to-board level substrate-guided wave optoelectronic interconnections

Enhancing Optical Network Capacity using DWDM System and Dispersion Compansating Technique

Testing of DWDM + CWDM high speed systems. Christian Till Technical Sales Engineer, EXFO

DATASHEET FMU-MC04E-A/B, w/expansion Port. Data Center & Cloud Computing Infrastruture Solutions

OPTICAL TRANSMISSION SYSTEM EMPLOYINGCARRIERLESS AMPLITUDE PHASE (CAP) MODULATION FORMAT

Low-power 2.5 Gbps VCSEL driver in 0.5 µm CMOS technology

Opto-VLSI based Broadband Reconfigurable Optical Add-Drop Multiplexer

WHITE PAPER LINK LOSS BUDGET ANALYSIS TAP APPLICATION NOTE LINK LOSS BUDGET ANALYSIS

40Gb/s & 100Gb/s Transport in the WAN Dr. Olga Vassilieva Fujitsu Laboratories of America, Inc. Richardson, Texas

MODELING AND EVALUATION OF CHIP-TO-CHIP SCALE SILICON PHOTONIC NETWORKS

Cisco s CLEC Networkers Power Session

Photonics and Optical Communication

Dynamic optical comb filter using opto-vlsi processing

Gigabit-class optical wireless communication system at indoor distances (1.5-4 m)

Implementation of Dense Wavelength Division Multiplexing FBG

Design of Ultra High Capacity DWDM System with Different Modulation Formats

Basic Optical Components

Proposal for 4-channel WDM (WDM4) for intermediate reach 100GbE SMF PMD

Theoretical Analysis of Random-Modulation Continuous Wave LIDAR

RZ BASED DISPERSION COMPENSATION TECHNIQUE IN DWDM SYSTEM FOR BROADBAND SPECTRUM

APSUNY PDK: Overview and Future Trends

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

Performance Limitations of WDM Optical Transmission System Due to Cross-Phase Modulation in Presence of Chromatic Dispersion

Ph.D. Course Spring Wireless Communications. Wirebound Communications

OPC1600 MUX WDM OADM SPLITTER

Effect of the FWM Influence on the CWDM Signal Transmission in the Optical Transmission Media

Integrated Optoelectronic Chips for Bidirectional Optical Interconnection at Gbit/s Data Rates

Wavelength Division Multiplexing of a Fibre Bragg Grating Sensor using Transmit-Reflect Detection System

2062 JOURNAL OF LIGHTWAVE TECHNOLOGY, VOL. 23, NO. 6, JUNE 2005

OPTICAL TRANSPORT CAPACITIES have been growing

Design and Performance Evaluation of 20 GB/s Bidirectional DWDM Passive Optical Network Based on Array Waveguide Gratings

Advances in Widely Tunable Lasers Richard Schatz Laboratory of Photonics Royal Institute of Technology

Utilizing Self-Seeding RSOA with Faraday Rotator Mirror for Colorless Access Network

40GBd QSFP+ LR4 Optical Transceiver

Carrierless amplitude phase modulation of VCSEL with 4 bit/s/hz spectral efficiency for use in WDM-PON

optoel 2013 VIII REUNIÓN ESPAÑOLA DE Optoelectrónica Julio de 2013 Alcalá de Henares Madrid LIBRO DE COMUNICACIONES

Data Sheet. AFBR-1150L / AFBR-2150L Fiber Optic Transmitter and Receiver for 150 Mbit/s MOST. Features. Description. Applications.

GS7000 and GainMaker Reverse Segmentable Node bdr Digital Reverse 2:1 Multiplexing System

Implementation and analysis of 2 Tbps MDRZ DWDM system at ultra narrow channel spacing

Optical networking. Emilie CAMISARD GIP RENATER Optical technologies engineer Advanced IP Services

A HIGH SPEED WDM PON FOR DOWNSTREAM DPSK ASK SIGNALS AND UPSTREAM OOK SIGNAL WITH BROADCAST CAPABILTY

TECHNICAL ARTICLE: DESIGN BRIEF FOR INDUSTRIAL FIBRE OPTICAL NETWORKS

Analog OptoLock FC300T

How Bend Insensitive Multimode Fiber is Affecting Installation and Testing of Enterprise and Data Center Cabling

Real-time white-light phosphor-led visible light communication (VLC) with compact size

Novel Design of Long Reach WDM-PON by using Directly Modulated RSOA

40Gb/s Optical Transmission System Testbed

S-band gain-clamped grating-based erbiumdoped fiber amplifier by forward optical feedback technique

City, University of London Institutional Repository

PERFORMANCE EVALUATION OF GB/S BIDIRECTIONAL DWDM PASSIVE OPTICAL NETWORK BASED ON CYCLIC AWG

22-Channel Capacity of 2.5Gbit/s DWDM-PON ONU Transmitter by Direct-Modularly Side-Mode Injection Locked FPLD

Transcription:

This is a postprint version of the following published document: C. Vázquez, P. J. Pinzón and I. Pérez. Visible WDM System Design for Multi-Gbit/s Transmission over SI-POF, Proc. SPIE 9387, Broadband Access Communication Technologies IX, 93870G (February 7, 2015); doi:10.1117/12.2081228 2015 Society of Photo Optical Instrumentation Engineers. One print or electronic copy may be made for personal use only. Systematic electronic or print reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited.

Visible CWDM system design for Multi-Gbit/s transmission over SI-POF Carmen Vázquez, Plinio Jesús Pinzón and Isabel Pérez Grupo de Displays y Aplicaciones Fotónicas, Dept. Tecnología Electrónica, Universidad Carlos III Madrid, Av. Universidad 30, 28911 Leganés, Madrid, Spain; ABSTRACT In order to increase the data rates of Multi-Gbit/s links based on large core step index (SI) plastic optical fibers (POF), different modulation scenes have been proposed. Another option is to use multiple optical carriers for parallel transmission of communication channels over the same fiber. Some designs to reach data rates of 14.77 Gb/s in 50 m, with 4 channels have been developed by off line processing. In this work, designs to test the potential of real Multi- Gbit/s transmission systems using commercial products are reported. Special care in designing low insertion loss multiplexers and demultiplexers is carried out to allow for greener solutions in terms of power consumption. Keywords: In-building networks, visible CWDM, plastic optical fibers, multiplexer, demultiplexer, ADAS, automobile. 1. INTRODUCTION Primarily due to the do-it-yourself installation, easy maintenance and high bending tolerance, large core step index (SI) plastic optical fibers (POF) are considered more suitable than 50 mm core diameter multimode glass fibers or perflourinated plastic optical fibers in some applications such as home networking [1]. It is shown to be impossible to achieve more than 2 Gb/s for 50 m single-core SI-POF using eye-safe VCSEL transmitters. In order to increase the data rates of Multi-Gbit/s links based on SI-POF, different modulation scenes have been proposed by different authors such as CAP-64, QAM512 [2, 3], DMT and M-PAM. Another option is to use multiple optical carriers in a single POF for parallel transmission of communication channels over the same fiber [4]. As the channels are broadband and far away in comparison to long haul optical communication, they are referred to as course wavelength division multiplexing (CWDM) systems. Current proposals of visible CWDM over SI-POF are based on spectral grids [5] with channels between 400nm and 700nm using laser diodes (LDs) or light emitting diodes (LEDs). Some designs to reach data rates of 14.77 Gb/s, with 4 channels via up to 50 m of a SI POF have been developed [6] using this approach but those rates are reached by offline-processing discrete multitone modulation. Initially, transmission with SI POF has been realized with only one channel, typically at 650 nm, reaching data rates of 100 Mb/s over links of 275 m [7]; even multi gigabit transmission over links of 50 m has been reached [8]. Commercial systems based on SI-POF links able to provide data rates around 1 Gb/s over 50 m are already in the market but operating at a single wavelength [9]. SI-POF technology has also an application niche in providing a solution to the exponential growth of infotainment devices within the car, along with the proliferation of ADAS (Advanced Driver Assistance Systems), that has created a demand for a more efficient way to interconnect devices within the automobile. ADAS global market is substantially growing in recent years and requires increasing the available bandwidth, nowadays up to 1 Gb/s [10] and potentially in the near future to be increased up to 5Gb/s [11]. Apart from the physical transmission characteristics of SI-POF, it is equally important to consider the optical components introduced to deploy advanced WDM-based architectures. A typical WDM optical communication link requires, at the very least, both a multiplexer and a demultiplexer which provide additional insertion loss into the system.

This results in a decrease of the available optical power budget of the system leading to a bit-rate penalty. Most of the POF-based mux/demux prototypes reported in literature have been developed on the basis of interference filters and diffraction gratings. However, it has been previously stated that the use of gratings for WDM-POF applications probably leads to the best results in terms of insertion loss [12] in which typical insertion losses of ~5dB are usually expected. Improved designs are reported in [13, 14]. In this work, designs to test the potential of real Multi-Gbit/s transmission systems using commercial products are reported. Special care in designing low insertion loss multiplexers and demultiplexers is carried out. A comparison with reported data of off-line processing CWDM systems in terms of power consumption is included. 2. VISIBLE CWDM SI-POF SYSTEM A real time bidirectional link between two points (e.g. two personal computers, PC1 and PC2) at data rates of multiple Gb/s using N CWDM SI-POF channels is designed from a commercial 1 channel link at 1 Gb/s at 50m and novel MUX/DEMUX designs with low insertion losses and high crosstalk. The link schematic is shown in Figure 1. The PCs are equipped with Gigabit Ethernet interfaces in combination with Media Converters (MCs) to generate and to read the data bits, respectively. The MCs transform the standard Gigabit Ethernet frames into M PAM signals (called Tx signals), and vice versa. In the transmitters (Txs), the different Tx signals modulate the respective laser diode (LDs) or Light Emitting Diodes (LEDs). These optical signals are multiplexed in a SI POF link up to 50m. A reflective diffraction grating based DeMux is used at the end of the link to split the different channels to their respective receivers (Rxs). At the receivers the optical signals are converted back to electrical signals (Tx signals) by using a commercially available receiver [5], and finally, the Ethernet frames are recovered by the MCs. (1) Fig. 1 Transmission scheme of the proposed SI-POF visible CWDM system with N channels between 400 and 700 nm. 2.1 Media Converters, transceivers and Power Budget Requirements The Media Converters specifications and performance are reported in [9]. This commercial system can be used to set up a real time single channel link at 1 Gb/s link over 50 m of standard SI POF using a light source at 650 nm with a transmission power of 3.15 dbm and total Insertion Losses (IL) up to 17.85 db (at 25ºC) is. Those MCs require a minimum power of -18dBm (at 650nm) at the receiver (including 2 db losses of receiver coupling loss) to establish a 1Gb/s link using SI-POF. 2.2 Multiplexer and Demultiplexer In this section, a new 5 channels low loss demultiplexer for SI POF CWDM networks is presented. It is based on a collimator/focusing lens and a reflective diffraction grating. The diffraction grating has an area of 50 mm 50 mm, 600 grooves/mm and efficiency between 56% to 68% in the range from 400 to 650 nm. The grating area limits the collimation distance, or effective focal length (EFL), to be less than 45 m, in order to get a collimated beam diameter <

50 mm (this is an approximation considering SI POFs with NA = 0.5). Therefore, the selected collimator/focusing lens has 50 mm diameter and 40 mm of EFL, in order to separate up to 5 channels, a distance greater than 1.3 mm. This guarantees channels with large a spectral bandwidth at -25 db (up to 50nm). A detailed description of diffraction grating based demultiplexer design for SI POF WDM networks is reported in [13]. b) Transfer Function [db] 390 415 440 465 490 515 540 565 590 615 640 665 690-5 -10-15 -20-25 -30 Wavelength, λ [nm] Figure 1. (a) Left: Mux-Demux experimental setup. (b) Right: Transfer function of a Mux-Demux configuration with 5 ports and 1 common fiber. The DeMux experimental setup is shown in Fig. 2.a; it is made of only two optical elements and it has ~60 mm diameter and ~70 mm length. This Mux-Demux is based on a common port and N input/output ports, which represent the number of channels. Each input/output port has its own focusing distance due to the dispersion of the lens in the range from 400 to 650 nm, see an example in Fig. 2.a (1 common port and 3 input/output ports). The number of channels, crosstalk and insertion losses are highly dependent of the configuration used in the SI-POF input/output fibers. The transfer function shown on Fig. 2b is obtained using an optimized SI-POF input/outputs configuration based on 1 common fiber and 5 input/output ports separated a distance greater than 1.2 mm. The IL measurements were done with the following procedure: 1) the light source is connected to the spectrometer using 3 m of SI POF with mode filters next to the source and spectrometer, this measurement is the reference spectra (100% of transmission), 2) the 3 m of SI POF is cut in half and each end is polished, 3) the SI POF section attached to the light source is connected to the common port and the SI POF section that is attached to the spectrometer is connected to the respective input/output port, 4) This procedure is repeated with the 5 input/output ports. The transfer function of each input/output port in the range from 370 nm to 700 nm is shown in Fig. 2.b and the main parameters are reported on Table I. Central Wavelength [nm] Table I. Basic parameters of the MUX/DEMUX Spectral Bandwidth [nm] at -25dB IL [db] 405 43 3.92 470 43 2.62 530 42 2.78 590 38 3.05 650 50 3.5

It is shown that the IL per channel of the proposed demultiplexer is less than 4 db. This value includes the IL produced by two polished surfaces. IL uniformity in a 5 channel configuration is 1.3 db, more than 1dB below the 4 channel configuration reported in [6] and it is reduced below 0.9 db in a 4 channel configuration. It is also shown that the spectral bandwidth at -25 db is higher than 38 nm. It is important to note that the measurements under 40dB are limited by the spectrometer sensitivity. This DeMux is compact and presents one of the best performances reported to date with only 2 optical elements. Current works of the authors are aimed to increase the number of channels to 8 keeping the IL below 5 db. 3. PRELIMINARY RESULTS OF THE PROPOSED TRANSMISSION SYSTEM The measured transfer function of the 5 input/output port, including 25 and 50 m of SI POF and two Mux-Demux devices is shown in Fig 3. a) Transfer Function [db] -10-15 -20-25 -30-35 -40-45 -50 390 415 440 465 490 515 540 565 590 615 640 665 690 Wavelength, λ [nm] b) Transfer Function [db] -10-15 -20-25 -30-35 -40-45 -50 390 415 440 465 490 515 540 565 590 615 640 665 690 Wavelength, λ [nm] Figure 2. Transfer function of a bidirectional link using a visible CWDM system with 5 channels made of 2 Mux-DeMux devices: a) 25 m of SI-POF, b) 50m of SI-POF. The overall system test has been done with only one channel at 650 nm, using the LD L650P0007 with an average transmitted power of 6 dbm (4 mw), and 50 m of SI POF. In this case, the received power is of about 8.1 dbm (total IL of ~15 db) which is enough to full fill the link budget and sensitivity requirements of the receiver [9]. On the other hand, the system produces an opened eye diagram with NRZ signals up to 333 MHz. Therefore, the bandwidth requirements for establishing the 1 Gb/s link are also full filled [9]. The system transmission bandwidth has been experimentally tested using the channel at 650 nm and a TCP bandwidth measurement tool (iperf). The results are shown in Fig.4. Figure 4. Transmission Test with one channel at 650 nm and 50m of SI-POF. The test is done with a TCP bandwidth measurement tool (iperf) with 4 parallel streams. The resulting mean bandwidth is 814 Mbits/s.

The different channels at 405, 470, 530, 590 nm and 650 nm can be used to increase the transmission link capacity, up to 5 Gb/s. 4. POWER CONSUMPTION DISCUSSION In the current system, a receiver sensitivity of -18dBm is required for a 1 Gb/s link proper operation (including 2dB loss at Rx). In a 25m length (see Fig. 3.a) fiber losses at 650nm are equal to -11dB, so the link is viable keeping the transmitter optical power at -3.5dBm, having a margin of 3.5dB. But in 50m length, fiber losses increase up to -15dB and transmitter optical power has to be increase up to 0dBm for keeping a margin of 3dB. A CWDM configuration with 4 channels is going to be considered for comparison purposes with the solution reported in [6]. For the worst case channel, a power budget improvement of 3.6 db is achieved (2.1 db in the DEMUX IL and 1.5dB in the MUX IL), see Table I, in an overall power budget of 18dB. This loss saving can be used for reducing the transmitter output power in more than 3dB or a 50% power consumption reduction. In our experiment it is used a LD output power of 6 dbm, although only 0dBm were needed, meanwhile in [6] a 10 dbm optical source output power at around 650nm is used. Input optical powers up to 19 dbm are considered in [6] at other wavelenghts with higher MUX/DEMUX insertion losses. 5. CONCLUSIONS A real time bidirectional link at data rates of multiple Gb/s using N CWDM SI-POF channels has been designed from a commercial 1 channel link at 1 Gb/s at 50m and novel MUX/DEMUX designs with low insertion losses and high crosstalk. An improvement of more than 3 db in power budget is achieved, in comparison with previous 4 channels CWDM SI-POF experiments. This loss saving can be used for reducing the transmitter output power implying a 50% power consumption reduction. The proposed designs can be scale up to an 8 channels system. Better Insertion Loss uniformity is also achieved. 6. ACKNOWLEDGEMENT This work has been sponsored by the Spanish institutions Ministerio de Economía y Competitividad under project TEC2012-37983-C03-02, Comunidad de Madrid under grant S2013/MIT-2790. REFERENCES [1] A. M. J. Koonen, and E. Tangdiongga, Photonic Home Area Networks, Journal of Lightwave Technology, 32(4), 591-604, 2014. [2] J.L. Wei, L. Geng, D.G. Cunningham, R.V. Penty, and I.H. White, Gigabit NRZ, CAP and optical OFDM systems over POF links using LEDs, Opt. Express 20, 2284 22289, 2012. [3] S Loquai, R Kruglov, B Schmauss, C.-A. Bunge, F Winkler, O Ziemann, E Hartl, and T Kupfer Comparison of Modulation Schemes for 10.7 Gb/s Transmission Over Large-Core 1 mm PMMA Polymer Optical Fiber Journal of Lightwave Technology, 31 ( 13), 2170-2176, 2013. [4]U. H. P. Fischer, M. Haupt and M. Joncic, Optical Transmission Systems Using Polymeric Fibers, (InTech, 2011). [5] M. Joncic, M. Haupt, U.H.P. Fischer, Standardization Proposal for Spectral Grid for VIS WDM Applications over SI-POF, in Proceedings of POF Congress, 351-355, 2012. [6]M. Jončic, R. Kruglov, M. Haupt, R. Caspary, J. Vinogradov, and U. H. P. Fischer, Four-Channel WDM Transmission Over 50-m SI-POF at 14.77 Gb/s Using DMT Modulation, IEEE Phot. Tech. Lett. 26,1328 1331 (2014).

[7] Cardenas Lopez D. F., Nespola A., Camatel S., Abrate S., Gaudino R. 100 Mb/s Ethernet Transmission Over 275 m of Large Core Step Index Polymer Optical Fiber: Results From the POF-ALL European Project. Journal of Lightwave Technology 27(14), 2908-2915, 2009. [8] Okonkwo C. M., Tangdiongga E., Yang H., Visani D., Loquai S., Kruglov R., C. bonnier B., Ouzzif M., Greiss I., Ziemann O., Gaudino R., Koonen A. J. Recent Results from the EU POF-PLUS Project: Multi-Gigabit Transmission Over 1 mm Core Diameter Plastic Optical Fibers Journal of Lightwave Technology 2011; 29(2) 186-193. [9] O. Ciordia, C. Esteban, C. Pardo, R. Pérez de Aranda, Commercial Silicon for Gigabit Communication over SI- POF, Proc. 22 nd POF conference, pp. 109-116 (2013). [10] http://www.kdpof.com/applications/automotive/ [11] R. Klos MOST in future automotive connectivity, MOST cooperation, 28, 2013. [12] L. V. Bartkiv and Y. V. Bobitski, "Design and optimization of concave diffraction grating for WDM multi/demultiplexer," in Laser and Fiber-Optical Networks Modeling (LFNM), 2010 10th International Conference on, 2010, pp. 128-130 [13] P.J. Pinzón, K. Heggarty, C. Vázquez and I. Pérez, Diffraction grating-based Multiplexers for SI-POF networks, Proc. 22 nd POF conference, pp. 36-41 (2013). [14] P.J. Pinzón, C. Vázquez, I. Pérez and P.C. Lallana Design and analysis of a WDM system for Multi-Gbit/s transmission over 50 m of SI-POF Proc. 23 rd POF conference, (2014).