SUPPLEMENTARY INFORMATION

Similar documents
Printed Organic Transistors for Ultraflexible and Stretchable Electronics

Supplementary Figures

Supporting Information

A large-area wireless power transmission sheet using printed organic. transistors and plastic MEMS switches

S.Vidhya by, Published 4 Feb 2014

A transparent, conformable, active multielectrode array using organic electrochemical transistors

Fabrication of a submicron patterned using an electrospun single fiber as mask. Author(s)Ishii, Yuya; Sakai, Heisuke; Murata,

Supplementary Materials for

Optimization of a Love Wave Surface Acoustic Device for Biosensing Application

Electronic supplementary material

SUPPLEMENTARY INFORMATION

Fully printable, strain-engineered electronic wrap for

Context Development Details Anticipated Effects

Semiconductor Physics and Devices

MECHANICAL PROPERTY OF CARBON NANOTUBE YARN REINFORCED EPOXY

Caterpillar Locomotion inspired Valveless Pneumatic Micropump using Single Teardrop-shaped Elastomeric Membrane

Supplementary Information. Highly conductive and flexible color filter electrode using multilayer film

Ubiquitous Displays and Sensors Activating Surfaces with Flexible Electronics. Dean Baker, Director FlexEnable. APAC Innovation Summit 2016, Hong Kong

Soft Electronics Enabled Ergonomic Human-Computer Interaction for Swallowing Training

Flexible glass substrates for roll-to-roll manufacturing

Supporting Information for. Standing Enokitake-Like Nanowire Films for Highly Stretchable Elastronics

Silver Nanowire Transparent Electrodes: Fabrication, Characterization, and Device Integration

Bend Sensor Technology Mechanical Application Design Guide

Integrated Focusing Photoresist Microlenses on AlGaAs Top-Emitting VCSELs

Supplementary materials for Tactile Feedback Display with Spatial and Temporal Resolutions

Supplementary information for Stretchable photonic crystal cavity with

The file. signal, and. the. from

Novel Approach to Make Low Cost, High Density PZT Phased Array and Its Application in Structural Health Monitoring

Piezoelectric Sensors and Actuators

Transparent p-type SnO Nanowires with Unprecedented Hole Mobility among Oxide Semiconductors

ELECTROSPINNING: SHAPE AND ALIGNMENT CONTROL

Photo-patternable and Transparent Films Using Cellulose Nanofibers for Stretchable, Origami Electronics

Bend Sensor Technology Mechanical Application Design Guide Mechanical Application Design Guide

Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea

Power generation with laterally-packaged piezoelectric fine wires

SUPPLEMENTARY INFORMATION

Supplementary Figure S1. Schematic representation of different functionalities that could be

Vertically Aligned BaTiO 3 Nanowire Arrays for Energy Harvesting

Supplementary Figure 1 Schematic illustration of fabrication procedure of MoS2/h- BN/graphene heterostructures. a, c d Supplementary Figure 2

SUPPLEMENTARY INFORMATION

Supplementary Materials for

Electronic Supplementary Information. Self-assembled Gold Nanorime Mesh Conductor for Invisible Stretchable Supercapacitor

Graphene-Based Three Dimensional Capacitive Touch Sensor for Wearable Electronics

Low Temperature Integration of Thin Films and Devices for Flexible and Stretchable Electronics

Development of a conformable electronic skin based on silver nanowires and PDMS

A Laser-Based Thin-Film Growth Monitor

Improving Organic Solar Cells

LIQUID CRYSTAL LENSES FOR CORRECTION OF P ~S~YOP

Supporting Information. Vertical Graphene-Base Hot-Electron Transistor

High-Speed Scalable Silicon-MoS 2 P-N Heterojunction Photodetectors

Measurement of Microscopic Three-dimensional Profiles with High Accuracy and Simple Operation

SUPPLEMENTARY INFORMATION

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

Flexible Glass Applications & Process Scaling

Supplementary Figures

Surface Topography and Alignment Effects in UV-Modified Polyimide Films with Micron Size Patterns

All-Printable Real-time Airframe Monitoring System (ARAMS)

Supplementary Materials for

Development of a Thin Double-sided Sensor Film EXCLEAR for Touch Panels via Silver Halide Photographic Technology

MANUFACTURING TECHNOLOGY

Expanding film and process for high efficiency 5 sides protection and FO-WLP fabrication

DEVICE FOR STRUCTURING OF ELECTROMAGNETIC RADIATION

3D Non-Linear FEA to Determine Burst and Collapse Capacity of Eccentrically Worn Casing

Mass transfer with elastomer stamps for microled displays.

SUPPLEMENTARY INFORMATION

Ultra High Thermal Conductivity Nanowire Filled Polymer Composites And Interfaces

Stretchable and bendable (tactile) sensors Future of interaction symposium 25/02/2016. Steven NAGELS

2007-Novel structures of a MEMS-based pressure sensor

Low-power carbon nanotube-based integrated circuits that can be transferred to biological surfaces

Design & Simulation of Multi Gate Piezoelectric FET Devices for Sensing Applications

Supporting Information. A Tough and High-Performance Transparent Electrode from a. Scalable Transfer-Free Method

Optical Bus for Intra and Inter-chip Optical Interconnects

Underground M3 progress meeting 16 th month --- Strain sensors development IMM Bologna

Supporting Information. for. Visualization of Electrode-Electrolyte Interfaces in LiPF 6 /EC/DEC Electrolyte for Lithium Ion Batteries via In-Situ TEM

p-n Junction Diodes Fabricated Using Poly (3-hexylthiophene-2,5-dyil) Thin Films And Nanofibers

Design, Fabrication, and Validation of an Ultra-Lightweight Membrane Mirror

61.32 C C C

XYZ Stage. Surface Profile Image. Generator. Servo System. Driving Signal. Scanning Data. Contact Signal. Probe. Workpiece.

How an ink jet printer works

Supplementary Materials for

High-speed logic integrated circuits with solutionprocessed self-assembled carbon nanotubes

Glued laminated timber beams repair.

LS-DYNA USED TO ANALYZE THE MANUFACTURING OF THIN WALLED CANS AUTHOR: CORRESPONDENCE: ABSTRACT

OPTI510R: Photonics. Khanh Kieu College of Optical Sciences, University of Arizona Meinel building R.626

Application Bulletin 240

Lecture 20: Optical Tools for MEMS Imaging

High-speed wavefront control using MEMS micromirrors T. G. Bifano and J. B. Stewart, Boston University [ ] Introduction

1 of 7 9/11/2013 8:56 AM

Atomristor: Non-Volatile Resistance Switching in Atomic Sheets of

MANUFACTURING TECHNOLOGY

(1) Brass, an alloy of copper and zinc, consists of 70% by volume of copper and 30% by volume of zinc.

Supplementary Figure 1. Schematic setup for preparation of a splay aligned film. (i)

POLYMER MICROSTRUCTURE WITH TILTED MICROPILLAR ARRAY AND METHOD OF FABRICATING THE SAME

A thin foil optical strain gage based on silicon-on-insulator microresonators

Electronics Materials-Stress caused by thermal mismatch

ASSESSMENT OF COMPOSITES REINFORCED WITH INNOVATIVE 3D WOVEN HOLLOW FABRICS

In 1950, plastic film was relatively

Vertex Detector Mechanics

Dowel connections in laminated strand lumber

Microprobe-enabled Terahertz sensing applications

Transcription:

A transparent bending-insensitive pressure sensor Sungwon Lee 1,2, Amir Reuveny 1,2, Jonathan Reeder 1#, Sunghoon Lee 1,2, Hanbit Jin 1,2, Qihan Liu 5, Tomoyuki Yokota 1,2, Tsuyoshi Sekitani 1,2,3, Takashi Isoyama 4, Yusuke Abe 4, Zhigang Suo 5 and Takao Someya 1,2 * *Correspondence should be sent to Takao Someya (E-mail: someya@ee.t.u-tokyo.ac.jp). Keywords: Pressure sensor, Nano fiber, E-skin, Flexible electronics, Bending insensitivity. NATURE NANOTECHNOLOGY www.nature.com/naturenanotechnology 1

Supplementary Figure 1. Electrospun pressure-sensitive nanofiber. Schematic illustration of the fabrication of a pressure-sensitive nanofiber using the electrospinning process. The prepared solution is composed of elastomer (fluorinated copolymer, vinylidenefluoride-tetrafluoroethylenehexafluoropropylene), CNT, graphene, and 4-methly-2-pentanone. 2 NATURE NANOTECHNOLOGY www.nature.com/naturenanotechnology

Supplementary Figure 2. Electrospun pressure-sensitive nanofiber. HRTEM image showing CNTs well dispersed in elastomer matrix. NATURE NANOTECHNOLOGY www.nature.com/naturenanotechnology 3

Supplementary Figure 3. Influence of fiber-deposition time on transparency and pressure sensitivity. Photograph of electrospun pressure-sensitive nanofiber on glass with different deposition times. The twodimensional areal densities of the fibers are 15, 24, 33, and 48%, respectively. 4 NATURE NANOTECHNOLOGY www.nature.com/naturenanotechnology

Supplementary Figure 4. Areal uniformity of large sensor sheet. a, Electrospun fiber on Au film (9 9 cm; the dashed line represents the measured area) for uniformity tests, and b average pressure response and standard deviation of the nine areas specified. The large-area uniformity of the electrospun fiber mesh was examined by depositing 9 9 cm 2 samples on Au-coated PET films. The top Au electrodes (1 cm 2 ) were deposited on another PET substrate, and pressure was applied at different locations on the large film. NATURE NANOTECHNOLOGY www.nature.com/naturenanotechnology 5

Supplementary Figure 5. Reversibility of nanofiber pressure sensor. Cyclic test of pressure sensor over 1000 cycles at 2 kpa (a, b), 300 Pa (c, d), and 80 Pa (e, f) using the same device. 6 NATURE NANOTECHNOLOGY www.nature.com/naturenanotechnology

Supplementary Figure 6. Response time of nanofiber pressure sensor. Pressure response of sensor with measurement interval of 5 ms. a, Response measured for 3 s by pressing twice with finger. b, Pressure response to first pressing. We expect that the reason for the fast response time after releasing is due to the conduction mechanism. When pressure is applied, the fibers begin to make contact with each other, forming new electrical paths. Then, the fibers are compressed, which increases the conductivity itself. While being releases, concentrated compressive stress immediately repels the fibers from each other, increasing the decrease in the conductivity. NATURE NANOTECHNOLOGY www.nature.com/naturenanotechnology 7

Supplementary Figure 7. Robustness of device under bending. a, Photograph of the device fabricated on 12.5-µm-thick PI substrate with a bending radius of 17 mm (red dashed line represents the device viewed from the side). b, Photograph of the device fabricated on 12.5-µm-thick PI substrate with a bending radius of 180 µm (red dashed line represents the device viewed from the side, scale bar represents 1 mm). c, Device fabricated on 75-µm-thick PI film after bending test. d, Device fabricated on 1.4-µm-thick PET after bending test. The black dashed line represents the fold line during the test. 8 NATURE NANOTECHNOLOGY www.nature.com/naturenanotechnology

Supplementary Figure 8. Pressure-response test in bent state. a, Photograph showing the measurement of the sensor response for a bending radius of 3 mm. b, Photograph of the sensor under a bending radius of 400 µm for the measurement of the pressure response. Bending radii of 80 µm, c (front view), and top view, d (scale bars are 5 mm). NATURE NANOTECHNOLOGY www.nature.com/naturenanotechnology 9

Supplementary Figure 9. Integrated device. a, Schematic illustration of vertical structure of single pressure sensor pixel. b, Micrograph of a single organic transistor (W/L = 100). c, Distribution of 10 10 NATURE NANOTECHNOLOGY www.nature.com/naturenanotechnology

mobility values of transistors in 144 pixels. d, Threshold voltage distribution of active matrix. e, Typical output characteristics of a transistor. f, Photograph of integrated sensor array attached to the surface of a soft balloon. (Scale bar represents 1 cm). The mobility of the transistors in the saturation regime was 0.5 ± 0.07 cm 2 /Vs, the on/off ratio exceeded 10 4, and the threshold voltage was 0.8 ± 0.26 V with a yield of 97.9%. NATURE NANOTECHNOLOGY www.nature.com/naturenanotechnology 11

Supplementary Figure 10. Pressure mapping of integrated device. Photograph showing the slight touching of the center area a, and its pressure distribution data b, Photograph showing pressing of top right side c, and its pressure distribution data d (scale bars represent 1 cm). 12 NATURE NANOTECHNOLOGY www.nature.com/naturenanotechnology

Supplementary Figure 11. Transparent E-skin. a, Photograph of transparent pressure-sensor array and its schematic illustration b. c, Images of sensor attached to arm and plastic model on top of it (scale bar represents 1 cm). d, Pressure distribution data from plastic model. The nanofibrous sensors were fabricated in a transparent 7 7 matrix that has a large area (9 9 cm 2 ) and is both ultra-flexible and lightweight. The size of each cell was 5 5 mm 2, the spacing was 10 mm, and the total thickness was approximately 5 μm. Indium tin oxide (ITO) layers were deposited on the PET layer as transparent electrodes (Supplementary Figs. S8a and S8b). The sensor matrix was placed on a human arm and had good mechanical contact with the skin. A plastic object weighing 7 g was gently placed on the device; then, the resistance of each cell was measured. The pressure was measured only in NATURE NANOTECHNOLOGY www.nature.com/naturenanotechnology 13

the areas making contact. No pressure was measured in the other areas although the device was bent (bending radius of roughly 5 cm) and highly wrinkled, thus demonstrating the feasibility of a highly sensitive, conformable, and bending-insensitive pressure sensor. 14 NATURE NANOTECHNOLOGY www.nature.com/naturenanotechnology

Supplementary Figure 12. Testing interference of electrical signal. a, Photograph of passive matrix sensor array with glass on top (the dashed line is the border of the glass). b, Measured pressure response while applying strong pressure on the glass. The maximum pressure that this device can detect is 3 kpa. The distance between pixels was 1 mm, and the unit is kpa. We evaluated the crosstalk of the nanofiber layer using a 4 4 array of 1-mm 2 pixels with a 2-mm pitch. Strong pressure (>1 MPa) was selectively applied to certain pixels, and the pressure distribution was measured. An extremely small current (<100 pa at an applied voltage of 1 V) was measured at the pixels without pressure, showing that the device detects pressure reliably and accurately with a 1-mm spacing between pixels. NATURE NANOTECHNOLOGY www.nature.com/naturenanotechnology 15

Supplementary Figure 13. Pressure response of sensor with different deposition times. A longer deposition time results in a less sensitive pressure sensor. 16 NATURE NANOTECHNOLOGY www.nature.com/naturenanotechnology

Supplementary Figure 14. Mechanical robustness of a device. a, A photograph of an integrated device that is crumpled (scale bar represents 1 cm). b, Pressure response (transfer curve) of one pixel before and after being crumpled 10 times (black represents before and red represents after). NATURE NANOTECHNOLOGY www.nature.com/naturenanotechnology 17

Supplementary Figure 15. Pressure measurement from artificial blood vessel. a, Photograph of measurement setup. b, Photograph of pressure sensor (sensor size is 2 mm 4 mm, Supplementary 18 NATURE NANOTECHNOLOGY www.nature.com/naturenanotechnology

Movie 4) on artificial blood vessel. Measured resistance of sensor from artificial blood vessel model with c 0, d 80, and e 120 mm Hg. f, Measured current during the repeated pumping of air into the tube at an applied voltage of 1 V. A small pressure sensor was attached to the tube with an outer radius of 1 cm, and was wrapped by a polymer film to detect the expansion of the vessel. For preliminary testing, the model blood vessel was connected to an air-pressure sensor to monitor and control the pressure inside the tube. NATURE NANOTECHNOLOGY www.nature.com/naturenanotechnology 19

Supplementary Figure 16. Experimental setup for measurement of pressure propagation from artificial blood vessel using artificial heart. a, Photograph of measurement setup. b, Circuit diagram for the voltage measurement. Water pressure was applied using a displacement-type artificial heart system. The applied pressure was sufficiently high enough that it saturated the voltage (<10 kω at the sensor, which corresponds to >400 Pa) in this circuit. 20 NATURE NANOTECHNOLOGY www.nature.com/naturenanotechnology

Supplementary Figure 17. Pressure response of sensor without using graphene. Sensitivity of the pressure-sensor device is much lower than that achieved using majority of graphene and small amount of CNTs. NATURE NANOTECHNOLOGY www.nature.com/naturenanotechnology 21

Supplementary Figure 18. Nanofiber feature under strain. Microscope images of a, as spun fiber layer, b, under large shear strain (40 %), and c, tensile strain (30 %) (Scale bars represent 20 µm). The nanofibers change their alignment to reduce the strain due to tensile stress. 22 NATURE NANOTECHNOLOGY www.nature.com/naturenanotechnology

Supplementary Figure 19. Numerical analysis of the bending of a fibrous mesh. a, We study the bending sensitivity of a fibrous sheet. As a qualitative illustration, the fibrous material is represented by a square lattice of ligaments. The fibers are assumed to be bonded and not allowed to slide with respect to each other. The simulation is done using the commercial software ABAQUS, and individual fibers are represented using linear beam elements (B21). The fibers are modeled as a linear elastic material; the thickness-to-length ratio of each ligament is 1:7. The axial strain in the fibers is mapped with color. b, In real device structure, the fibrous sensor layer is sandwiched between two electrodes. When the electrodes are compliant, the sensor layer bends freely. The top electrode is compressed and the NATURE NANOTECHNOLOGY www.nature.com/naturenanotechnology 23

bottom electrode is stretched. When the electrodes are stiff, however, each electrode bends freely but does not stretch or compress, so that the sensor layer is sheared. The shear strain is maximum at the edge of the sandwiched structure and the shear strain is larger if the sandwiched structure is longer. This phenomenon is one of the reasons for which devices with a thinner electrode and sensing layer have less strain, thus diminishing the electrical properties when devices are bent. 24 NATURE NANOTECHNOLOGY www.nature.com/naturenanotechnology

Movie S1. A movie showing the uniformity of a large-area pressure response. The size of the device is 9 cm 9 cm with a pressure-sensitive nanofiber layer deposited uniformly on the bottom Au film. Then, a 1 cm 2 -sized top electrode is pressing a different area. Movie S2. A movie showing the pressure response of the sensor under a completely folded state. The center of the device was folded on thin Cu wire. The bending radius of the sensor was approximately 80 µm. Movie S3. A movie showing the pressure response of an integrated sensor attached to a soft balloon, and showing the distribution of the pressure under complex deformation. Movie S4. A movie showing the pressure response of a sensor attached to a fingertip and pressed by another finger. The bending radius of the finger was approximately 7 mm. NATURE NANOTECHNOLOGY www.nature.com/naturenanotechnology 25