RESIDENTIAL SOLAR ROOF TOP EXPEDITED PERMITTING GUIDELINE. 10 KW OR LESS

Similar documents
SOLAR PV MICROINVERTER/ACM STANDARD PLAN - COMPREHENSIVE Microinverter and ACM Systems for One- and Two- Family Dwellings

PLOT PLAN INSTRUCTIONS ROOF MOUNT SOLAR AN ACCURATE PLOT PLAN IS NECESSARY TO PROCESS YOUR PERMIT

Basic Information Required for Photovoltaic Plan Check Submittal *Informational Purposes Only*

PV System Structural Criteria

Structural Criteria for Residential Flush-Mounted Solar Arrays

Structural Criteria for Residential Rooftop Solar Energy Installations

Structural Criteria for Residential Rooftop Solar Energy Installations

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Basic Information Required for Photovoltaic Plan Check Submittal *Informational Purposes Only* 2013 CEC

Supplemental Calculation Sheets for Inverter #2

Planning and Building Services Solar PV Standard Plan Simplified Central/String Inverter Systems (One- and Two-Family Dwellings)

Single-Family Dwelling Submittal Requirements

Calculating AC Line Voltage Rise for IQ-Series Micros with Q Cable

Electrical requirements for plans on all new homes, additions, remodels & Service upgrades

2014 NEC Changes Part 1

Calculating AC Line Voltage Drop for S230 Microinverters with Engage Cables

SECTION PANELBOARDS

Chapter 1. Applied Grounding and Bonding. Applied Grounding and Bonding 9/18/2011. Introduction. Introduction. Paul Dobrowsky Member NEC Panel 5

CP /240-MC4 User Manual

UNITY/I TM. Installation Manual. UT3K, UT4K, UT5K and UT8K. Single-Phase Uninterruptible Power Systems

DP&L s Technical Requirements for Interconnection and Parallel Operation of Distributed Generation

Calculating AC Line Voltage Drop for M215 Microinverters with Engage Cables

Photovoltaic System Commissioning and Testing A Guide for PV System Technicians and Engineers

City of Thousand Oaks

Signs, Canopies & Awnings City of Oshkosh Department of Community Development

2. Determine the number of Modules/Microinverters required. (1134 modules is 2 less than 250 KW but works well with max comm.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Tel: Fax:

Residential Room Additions

PLANNED SIGN PROGRAM CHECKLIST

Advanced Pulse WattNode - Option PV (Photovoltaic)

Installation/User Manual

APS M1P Single-phase Micro-inverter Installation and User Manual

UFGS (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

A/C Change-Out Permit Guidelines - Residential

JEFFERSON LAB TECHNICAL ENGINEERING & DEVELOPMENT FACILITY (TEDF ONE) Newport News, Virginia

SECTION CABLE TRAYS

City of Lompoc Building & Safety Services Section 100 Civic Center Plaza Lompoc, CA Phone: Fax:

Clark County Fire Prevention Las Vegas Nevada

Commercial Infill Project Guide

Residential Construction Checklist Single and Two Family Construction

Niguel Shores Community Association Architectural Committee (AC) EXTERIOR MODIFICATION SUBMITTAL (EMS) FINAL APPLICATION

APS M1P Single-phase Micro-inverter Installation and User Manual

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JAN01

Installation requirements

Site Plan Review Application. Interest in the Property (e.g. fee simple, land option, etc.)

Capstone Turbine Corporation Nordhoff Street Chatsworth CA USA Phone: (818) Fax: (818) Web:

SUBMITTAL REQUIREMENTS FOR COMMERCIAL BUILDING PROJECTS

E N G I N E E R I N G M A N U A L

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

3 Basic Code Enforcement, Part 3

Section L5: PRE-ENERGIZATION TEST PROCEDURES FOR LOAD-ONLY ENTITIES AND TRANSMISSION-ONLY ENTITIES

AWNING SYSTEM INSTALLATION INSTRUCTIONS ALL VERTICAL WALLS

ADMINISTRATIVE DESIGN REVIEW Information

CITY OF MERCER ISLAND DEVELOPMENT SERVICES GROUP 9611 SE 36 th Street, Mercer Island, WA (206)

Certificate of Appropriateness (CoA) Checklist

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JUN15

Building Standards Department. Markham eplan Submission Standards For Building Permits, Sign Permits and Zoning Preliminary Review

SECTION III SUBMITTALS AND APPROVALS

FSEC APPROVAL # XL15-NT

PEAK VIEW RANCH HOMEOWNERS ASSOCIATION Architectural & Design Review Request Form

PV Activity 3 PV Loads

Checklist for Minor Plan Modification

DEVELOPMENT REVIEW COMMENTS LAND DISTURBANCE PERMIT (LDP) CLEARING CLEARING & GRUBBING GRADING. Date Reviewed by. Project Name

TOWN OF AMHERST PLANNING DEPARTMENT MINOR SITE PLAN AND MINOR ADJUSTMENT REVIEW AND APPROVAL PROCEDURE

Customer Requirements RF Antenna Installations

EE Grid-Tied PV Systems. Y. Baghzouz Spring 2011

Remotes Case 2&3 Form REINDEER Cases 2&3 -Connection Impact Assessment (CIA) Application

REPORT HOLDER: ISAIAH INDUSTRIES, INC. EVALUATION SUBJECT:

NOTE: This paper relates to a closed book exam & therefore candidates should attempt this exam paper with no study-notes or text books.

Embedded Generation Connection Application Form

GCG ASSOCIATES, INC. February 8, Mr. Nathaniel Strosberg, Town Planner 101 Main Street Town of Ashland Ashland, MA 01721

MISSISSIPPI STATE UNIVERSITY Office of Planning Design and Construction Administration

System Components and Accessories

DEPARTMENT OF COMMUNITY DEVELOPMENT SITE PLAN INFORMATION

ADDENDUM NO. 2 PROJECT: COURTLAND PUMP STATION CONTRACT: IFB NO COM.00030

SAFETY AND HEALTH STANDARD ELECTRICAL GROUNDING Effective Date: 07/17/10 Standard: Document Number: KUCSH0039 Rev: 4

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SPECIAL SPECIFICATION LIGHTNING PROTECTION SYSTEM

A. Action Submittals: Written and graphic information that requires Architect's responsive action.

.2 Accompany all submissions with a transmittal letter, in duplicate, containing:.4 Specification Section number for each submittal

Embedded Generation Connection Application Form

PLANNING DEPARTMENT SUBMITTAL REQUIREMENTS FOR CONDITIONAL USE PERMITS CLASS 4 DEVELOPMENT REVIEW PROCESS. A. Written Material

White Lake Township Building Dept Highland Rd. (248) White Lake, MI Fax (248)

COMMERCIAL / INDUSTRIAL APPLICATION FOR PLAN EXAMINATION AND BUILDING PERMIT

SECTION SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES

PVCHECK Rel /01/13

DC Current Transducers

Issued: September 2, 2014 Effective: October 3, 2014 WN U-60 Attachment C to Schedule 152, Page 1 PUGET SOUND ENERGY

Section 16621A - AUTOMATIC TRANSFER SWITCH. Part 1 General

B. Manufacturers: Square-D, G.E. or Westinghosue.

DOCUMENT SUBMITTAL REQUIREMENTS FOR AN ALTERATION OR ADDITION TO AN EXISTING SINGLE-FAMILY DWELLING OR MULTI-FAMILY DWELLING

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

Section. DEVELOPMENT STANDARDS City of Ellensburg ILLUMINATION STANDARDS

Address: South Elgin, IL Phone: ( ) - Fax: ( ) - Cell: ( ) - Contractor Type: Phone: ( ) - Fax: ( ) - Cell: ( ) - Contact Type:

Certificate of Compliance

BUILDING PLANS. BUILDING INSPECTIONS DEPARTMENT

ELECTRIAL AND SIGNING MATERIALS STANDARDS VOLUME 3

2015 NFPA 70E. SESHA 2015 ARIZONA MINI CONFERENCE December 10, 2015 Intel Corporation

WILTON MANORS, Island City 2020 WILTON DRIVE, WILTON MANORS, FLORIDA 33305

Transcription:

RESIDENTIAL SOLAR ROOF TOP EXPEDITED PERMITTING GUIDELINE. 10 KW OR LESS INFORMATION GUIDELINE 24A May 2015 CITY OF ESCONDIDO BUILDING DIVISION 201 N. BROADWAY, ESCONDIDO, CA 92025 (760) 839-4647 Plan Submittal Documents Complete the attached permit application form and attached solar eligibility checklist. Complete a standard electrical plan or provide an electrical single line drawing. The completed checklist, electrical plan and specification sheets will allow for an expedited plan review. Two complete sets of plans consisting of the Plot Plan, Roof plan with Array and equipment location, Array support and bonding, equipment manufacturer specification sheets and listing approvals and design drawings. Basic Plan Check information Provide a roof plan showing the PV module layout, and the following fire safety items: approximate location of roof access points, location of State Fire Marshal code-complaint fire access pathways, PV system fire classification and the location of all required placards and markings. Show the location of all electrical disconnects and electrical panels and equipment. Provide at least two copies of the manufacturer s information for cells, modules, inverters, optimizers, monitoring meters and module support systems. Include all information such as UL listing components or a nationally recognized testing agency for specific associated devices. Specify the module bonding device and listing approval. Verify compatibility of the device with the modules and module support system. Include an equipment ground sized per NEC Table 250-122 and a minimum # 8 grounding electrode conductor from the grounding electrode to the array. Plan review Permit applications must be submitted to the Building Department in person. Permit applications utilizing the Eligibility Checklist will have their permit expedited. Plan review fees are due at the time of plan submittal. Attach the Checklist 24B and Guideline 24A to the plans and equipment specifications. Fees Plan review fee $86.00 Building Fee $86.00 Guideline #24 (01-14).doc Page 1 of 3

Electrical Fee $40.00 (without panel upgrade) Inspections Once permits have been issued and the system has been installed, it must be inspected before final approval is granted. On-site inspection can be scheduled by calling 760-839-4646. Inspection request received by 7am the day of the requested inspection will normally receive inspection the same day. Permit holders must be prepared to show conformance with all technical requirements in the field at the time of inspection. Approved plans and inspection card must be on site for the inspector. An OSHA approved ladder must be provided for access to the roof. The inspector will verify that the installation is in conformance with the applicable codes and approved plans. See the following checklist for common points of inspection that the applicant should be prepared to show compliance: Number of PV modules and model number match plans and specification sheets. Array conductors and components are installed and supported per current code. PV array is properly grounded as demonstrated on the plans. Electrical boxes are accessible and connections are suitable for the environment. Array is fastened, sealed and supported according to the plans and details. Conductors and conduit size and ratings match the approved plans. All appropriate placards are installed and displayed. Equipment ratings and listings match the approved plans. The main electrical service is properly connected to the grounding electrode. Inverter has a rating as high as max voltage on PV power source sign. DC-side overcurrent circuit protection devices are DC rated at least as high as max voltage on sign. Switches and OCPD s are installed according to the manufacturer s specifications. Sum of the OCPD s and the inverter OCPD is rated for not more than 120%of the bus bar rating of the main service. When applying the 120% PV OCPD rule, the main electrical panel is not a center fed panel. Required placards for main electrical panels that are de-rated when applying the 120% PV OCPD rule. Guideline #24 (01-14).doc Page 2 of 3

Guideline #24 (01-14).doc Page 3 of 3

Filename: Directory: Template: Guideline #24 (01-14).doc C:\Users\rseraile\Desktop C:\Users\rseraile\AppData\Roaming\Microsoft\Templates\Normal. dotm Title: Subject: Author: Janet O. Snider Keywords: Comments: Creation Date: 2/3/2015 2:50:00 PM Change Number: 33 Last Saved On: 5/5/2015 7:26:00 AM Last Saved By: Employee Total Editing Time: 205 Minutes Last Printed On: 5/12/2015 12:52:00 PM As of Last Complete Printing Number of Pages: 3 Number of Words: 626 (approx.) Number of Characters: 3,570 (approx.)

ELIGIBILTY CHECKLIST FOR EXPEDITED RESIDENTIAL SOLAR PHOTOVOLTAIC PERMITTING INFORMATION GUIDELINE 24B May 2015 CITY OF ESCONDIDO BUILDING DIVISION 201 N. BROADWAY, ESCONDIDO, CA 92025 (760) 839-4647 Complete this Eligibility Checklist, the permit application and standard electrical plan or provided an electrical single line drawing along with the manufacturer s specification sheets and the project will qualify for an expedited plan review. See Information Guideline # 24A for plan review and inspection requirements. ADDRESS: PERMIT NUMBER GENERAL REQUIREMENTS A. System size is 10 kw rating or less. Y N B. The solar array is roof mounted on a one or two family dwelling. Y N C. The solar panel/array will not exceed the maximum legal building height. Y N D. Solar system is utility interactive and without storage batteries. Y N E. Permit application is complete and attached. Y N ELECTRICAL REQUIREMENTS A. No more than 4 module strings are connected to the system. Y N B. No more than 2 inverters or micro inverters are utilized in the system. Y N C. The PV system is interconnected to a single-phase AC service panel of nominal 120/220 Vac with bus bar rating of 225 amps or less. Y N D. The PV system is connected to the load side of the utility distribution equipment. Y N E. A Solar PV Standard Plan or electrical single line drawing and supporting documentation is completed and attached Y N F. A minimum # 8 grounding electrode conductor from the grounding to the array and an equipment ground sized per NEC Table 250.122. Y N G. A listed module bonding device or a device compatible with the modules and module support system is installed. Y N H. A grounding electrode exist or 2 additional electrodes a minimum of 6 apart. Y N I. The electrical panel has not been de-rated. Y N Guideline #24 (01-14).doc Page 1 of 2

STRUCTURAL REQUIREMENTS A. Complete structural calculations and details are attached. (If required) Y N B. Is the roof a single roof without reroof overlay? Y N C. Does the roof structure appear structural sound, without signs of alteration or deterioration or sagging? Y N D. Modules do not overhang any roof edge. Y N E. A roof plan and anchor layout is attached. Y N FIRE SAFETY REQUIREMENTS A. Clear access pathways provided Y N B. Verification of fire classification for the solar modules and support system is provided. Y N C. All required markings, labels and placards are provided. Y N D. Solar system is utility interactive and without storage batteries. Y N E. A diagram of the roof layout of all panels, modules, access pathways and locations of the electrical disconnecting means and all associated equipment is shown. Y N Notes: 1. These criteria are intended for expedited solar permitting process. 2. If any items are checked NO, revise the design to fit within the Eligibility Checklist, otherwise permit application may go through the standard process. Guideline #24 (01-14).doc Page 2 of 2

Filename: Directory: Template: Guideline #24B.docx C:\Users\rseraile\Desktop C:\Users\rseraile\AppData\Roaming\Microsoft\Templates\Normal. dotm Title: Subject: Author: Diana Lecca Keywords: Comments: Creation Date: 5/4/2015 2:04:00 PM Change Number: 4 Last Saved On: 5/6/2015 10:04:00 AM Last Saved By: Employee Total Editing Time: 0 Minutes Last Printed On: 5/12/2015 12:53:00 PM As of Last Complete Printing Number of Pages: 2 Number of Words: 459 (approx.) Number of Characters: 2,619 (approx.)