Description, operating instructions and hardware specification of the HL Transverse balance measurement module (TBMM).

Similar documents
Requirements and Test Methods for Very-High-Bit-Rate Digital Subscriber Line (VDSL) Terminal Equipment

Part VI: Requirements for Integrated Services Digital Network Terminal Equipment

Part VI: Requirements for ISDN Terminal Equipment

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

CHAPTER 4 MEASUREMENT OF NOISE SOURCE IMPEDANCE

FREQUENCY AGILE FM MODULATOR INSTRUCTION BOOK IB

Specification for Conducted Emission Test

MAINTENANCE MANUAL EUROPEAN LEASE LINE INTERFACE BOARDS 19D904245G1 AND 19D904744G1

1.2 KW, N+1 REDUNDANT, POWER-FACTOR CORRECTED, 12V FRONT END

Calibration Techniques for the Home Lab

Schlöder GmbH - EMC Test and Measurement Systems Model #

DS 6000 Specifications

Multiple Instrument Station Module

High Voltage Differential Probe

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

Magnetic-Field Test System / Low-Frequency Test System for Emission and Immunity Tests / MTS-800

Multi-function Gain-Phase Analyzer (Frequency Response Analyzer) Model 2505

Data Sheet SC5317 & SC5318A. 6 GHz to 26.5 GHz RF Downconverter SignalCore, Inc. All Rights Reserved


UHF Wireless System CONTENTS

ECE3204 D2015 Lab 1. See suggested breadboard configuration on following page!

COUPLING / DECOUPLING NETWORK (CDN) CDN AF TYPE, CDN CAN

9 Specifications. Specifications NOMINAL CHARACTERISTICS

1. An engineer measures the (step response) rise time of an amplifier as. Estimate the 3-dB bandwidth of the amplifier. (2 points)

FIBRE CHANNEL CONSORTIUM

Group: Names: (1) In this step you will examine the effects of AC coupling of an oscilloscope.

Cool Power Technologies

MSO Supplied with a full SDK including example programs Software compatible with Windows XP, Windows Vista and Windows 7 Free Technical Support

Property of Ramsey Electronics, Inc. Do not reproduce or distribute.

Dev Bhoomi Institute Of Technology Department of Electronics and Communication Engineering PRACTICAL INSTRUCTION SHEET

Output Voltage Output Amps Input Range Max. Iin FL Efficiency (Tb=25 C) O/P Set Point

BENCHMARK MEDIA SYSTEMS, INC.

XR FSK Modem Filter FUNCTIONAL BLOCK DIAGRAM GENERAL DESCRIPTION FEATURES ORDERING INFORMATION APPLICATIONS SYSTEM DESCRIPTION

Probing for oscilloscope

SC5307A/SC5308A 100 khz to 6 GHz RF Downconverter. Datasheet SignalCore, Inc.

NI PXIe-5601 Specifications

IEC Electrical fast transient / Burst immunity test

The Practical Limitations of S Parameter Measurements and the Impact on Time- Domain Simulations of High Speed Interconnects

CS114 + CS115 + CS116

WaveStation Function/Arbitrary Waveform Generators

WaveStation Function/Arbitrary Waveform Generators

Emerging Standards for EMC Emissions & Immunity

Trees, vegetation, buildings etc.

Measurement and Analysis for Switchmode Power Design

CPCO Series DC-AC Current Probe, Clamp On, 160mm, ±1000A ±2000A ±4000A ±8000A ±12000A, ±16000A

Technical Datasheet UltraScope USB

(DOSA) VDC, 5.5 A.

SDM3045X Digital Multimeter. DataSheet

Coupling- / Decoupling Network. 150 khz 300 MHz. 150 khz 230 MHz. 10 khz 230 MHz. IEC and CISPR 15 / CISPR 22 IEC

WHALETEQ. ESU Neutral Electrodes Impedance Tester. Model: HFPA150. User Manual

UP1301A-( )( ) SERIES

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

R1TRFTTE. Nemko Canada Inc. 303 River Road Ottawa, Ontario, Canada, K1V 1H2 +1 (613) Sangoma Technologies

PC to Radio Audio and Key-line Interface

i Intelligent Digitize Emulated Achievement Lab

CS101. Conducted Susceptibility CS101. CS101 Maximum Current. CS101 Limits. Basis For CS101 Limits. Comparison To MIL-STD Vdc or Less

2302 Battery Simulator 2306, 2306-PJ Battery/Charger Simulators

PNRRKIT. Portable Networked Re-Radiating Kit Technical Product Data. Features. Description. Utilizes Existing Roof Antenna

Chapter 6 Specifications

TF TF Analyzer 2000 Measurement System

Battery Simulator Battery/Charger Simulators

Data Sheet GTD21148L SERIES 40W. (201) Switching Power Supplies

DC/DC power module 1.8 V / 5A / 9W

TA MHz ±700 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

SPECIFICATION AC/DC ADAPTOR. CUSTOMER SPEC:INPUT: V AC 50/60Hz OUTPUT:24VDC500mA SAMPLE NO: REV.: B ISSUE DATE:

Quad 12-Bit Digital-to-Analog Converter (Serial Interface)

P08050 Testing Strategy Document

SDM3045X Digital Multimeter. DataSheet

Coupling/Decoupling Networks (CDN)


The University of Jordan Mechatronics Engineering Department Electronics Lab.( ) Experiment 1: Lab Equipment Familiarization

PM 6669 High-Precision Frequency Counter Specifications

2520 Pulsed Laser Diode Test System

SPECIFICATION. SilverStone. 300W SFX Switching Power Supply FSP300-60GHS Meet 80 Plus Active PFC Circuit Full Range Input Small Size

PDN Probes. P2100A/P2101A Data Sheet. 1-Port and 2-Port 50 ohm Passive Probes

DECLARATION OF CONFORMITY

The Causes and Impact of EMI in Power Systems; Part 1. Chris Swartz

ITT Technical Institute. ET215 Devices I Chapter 2 Sections

Output Impedance. Duty Cycle Range. Buffer Size Resolution. PROTECTION Input Over Voltage. Output Short Circuit. TRIGGERING Sources.

Model LIA100. Lock-in Amplifier

Testing and Verification Waveforms of a Small DRSSTC. Part 1. Steven Ward. 6/24/2009

Keysight Measuring High Impedance Sources Using the U8903B Audio Analyzer. Application Note

DC/DC power module 3.3V / 4.5A / 14.8W

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

Specification PTC 281: Telecom Requirements for Customer-connected

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

How to Measure LDO PSRR

PXIe Contents. Required Software CALIBRATION PROCEDURE

AC/DC Power Supply Series APPLICATION NOTE

10. High-Boost HAM. Design Guide & Applications Manual. Maxi, Mini, Micro Family DC-DC Converters and Configurable Power Supplies

Analog Arts SF990 SF880 SF830 Product Specifications

AcBel Product Specification

Voltage Sensors URV5-Z

PQube 3 Specifications

khz to 2.9 GHz Spectrum Analyzer

Model 25A Manual. Introduction:

SE014S110 Power Module; dc-dc Converter: 48 Vdc Input, 110 Vdc Output, 14 W

Agilent U1273A/U1273AX Handheld Digital Multimeter. Quick Start Guide

SDI SPECTRADYNAMICS, INC. HIGH PERFORMANCE DISTRIBUTION AMPLIFIER OPERATING MANUAL

High Power Monolithic OPERATIONAL AMPLIFIER

Transcription:

, operating instructions and hardware specification of the HL 8240 - Transverse balance measurement module (TBMM). The increasing use of telecom equipment in ultrafast applications has enhanced the need for obtaining the high-frequency measurement device in a form suitable for transverse balance measurements, controlling via USB port, and easy integrated with existing HL measurement systems like telecom conformance analyzer TCA-8200. From this view point, it is desirable to obtain sine generator providing wide frequency range, set of measurement terminations meeting most of the modern telecom standard requirements, and high-precision balanced measurement attenuators supporting self-calibration and compensation procedures. Transverse balance measurement module HL 8240 is designed for automatic compliance testing of telecom equipment for transverse balance. Figure 1 A general view of the Transverse balance measurement module HL 8240 1

TBMM Block and Connection diagrams TBMM comprises following functional blocks (see Figure 2) USB Controller FTDI USB Controller supporting USB-2 interface which providing high speed controlling by software objects of the TCA unit. For testing purpose TBMM should be connected to the TCA unit via USB interface (see Figure 3). 1-2-3. Signal generator with attenuator and adjustable impedance 100/135 Ohm terminated sine-generator providing frequencies up to 35MHz and output attenuator being adjusted within range 0 15.5 db and increment 0.5 db. Generator s termination should be set providing an impedance matching with connected EUT. 4. Balancing capacitors Capacitive compensation circuit providing separate Tip and Ring capacitance setting within range 6.4 13.22 pf 5. Polarity switch Relay switch providing either normal or reverser line polarity for EUT connection 6. Internal metallic termination Set of precision resistors terminating EUT and being either 100 Ohm or 135 Ohm 7. EUT Connection switch Relay switch connecting the measurement circuit either internal termination (block 6) or EUT. Test signal can be applied to EUT if the switch is set to external state. 8. Longitudinal and 10. Metallic preamplifiers Operational amplifier circuits composing measurement paths and providing wide measurement dynamic range. They are terminated by 50 Ohm unbalanced connectors, there are Long/Met and Metallic measurement output channels respectively. For testing purpose, only Long/Met channel should be connected to the TCA unit (see Figure 3) 9. Measurement switch Relay switch providing either measurement configuration. There are two following configurations: Single channel supporting longitudinal measurements on Long/Met connector Dual channel supporting simultaneous longitudinal and metallic measurements on Long/Met and Metallic connectors respectively This measurement switch simplifies a test procedure and allows using only one measurement connection with the TCA unit (see Figure 3) Insulated GND Insulated ground jack providing direct connection of the EUT measurement ground to the ground point of the balance measurement bridge (see Figure 3) 2

Figure 2. TBMM Block diagram EUT Meas. GND TCA-8200 TIP RING HL8240 Insulated GND T EUT R USB Long/Met 75 Ohm Rx USB Figure 3 TBMM Connection diagram 3

TBMM Calibration and verification procedures All TBMM s software applications are separated by their purpose in two suites: TBMM Calibration suite and TBMM measurements suite. Calibration procedure of longitudinal attenuations is split up into 3 parts for 3 frequency ranges, there are up to 2MHz for reference balance 25dB, 2MHz 12MHz for reference balance 30dB, and 12MHz 35MHz for reference balance 35dB. Above measurement range partition provides maximum measurement precision for compliance testing because of matching with standard requirements. TBMM Calibration suite consists of 3 groups, which include tests used for calibration purposes: Self-verification tests All tests from the group are based on the TCA measurement script and intended for quick performance verification of keying TBMM characteristics at the production stage. a. Max longitudinal relative level b. Generator relative output level vs sent code c. Gradient of output attenuator vs sent code d. TBMM frequency response Calibration adjustment tests All tests from the group are based on the TCA measurement script and intended for adjustment of the internal reference calibration parameters such as metallic and longitudinal attenuations and output levels versus stimulus frequency. a. Metallic attenuation vs frequency b. Longitudinal attenuation vs frequency c. Generator output level vs frequency Calibration verification tests. All tests from the group are based on the TCA measurement script and intended for performing periodic calibration. a. Self-balance adjustment b. Max transverse balance c. Transverse balance deviation Notes: Changing reference calibration data affects test performance. The tests in the Calibration Adjustment group should be performed in the order they are listed. After the Calibration Adjustment tests have been completed, the Calibration Verification tests should be performed. Some tests in the Calibration Verification require use of external test equipment not supplied with the instrument (see #5 in Table 2). The Calibration Adjustment tests are not necessary if the Calibration Verification tests pass For detailed description of the calibration tests see Table 1. Purposes Max longitudinal relative level This self-verification procedure is based on the TCA Script and should be applied in the production stage as a quality control. The procedure compares maximally available output longitudinal level with its limit on the internal balanced reference termination. Measures longitudinal levels, in dbv, versus stimulus frequencies within the range 100k-30MHz and find maximum level which should be less than 55 dbv Production quality inspection fit for purpose. Evaluates of the general suitability of the circuit for balance measurements within high frequency range. 1. Make a maximum unbalance of the measurement circuit 4

Notes Purposes Notes Purposes Notes Purposes Notes 2. Measure longitudinal voltage for the found unbalanced state 3. Compare obtained voltage with respective limits for low and high reference frequencies Measurement limits are dependent on the actual attenuation of TCA AC attenuator 75 Ohm Rx The test is intended for production quality inspection and should be run first of all others. Generator relative output level vs sent code (output level linearity) This self-verification procedure is based on the TCA Script and should be applied in the production stage as a quality control. The procedure compares maximally available output longitudinal level with its limit on the internal balanced reference termination. Measures generator voltage, in dbv, versus output attenuation, in sent digital code, which should be fitted to mask (limits). 1. Measure generator voltage, in dbv, versus output attenuation, in sent digital code 2. Try to fit obtained measured points to defined mask (limits) The test is intended for production quality inspection and should be run before any TBMM s calibrations Gradient of generator output level This self-verification procedure is based on the TCA Script and should be applied in the production stage as a quality control. The procedure measures gradient of the output attenuator within the range of sent controlling code and compares the gradient deviations with the limits Production quality inspection. Testing of TBMM s sine-generator being suitable for adjustment of its output level with defined increment 1. Measure a difference of the output sending levels, in db, between two neighbor codes being sent to TBMM s attenuator 2. Compare obtained level differences with defined limits The test is intended for production quality inspection and should be run before any TBMM s calibrations Metallic attenuation vs freq This calibration procedure is based on the TCA Script and should be performed under TBMM calibration conditions. The procedure calculates metallic attenuation versus stimulus frequency characteristic and compares obtained values with limits for self-checking purpose. To acquire metallic voltage at the EUT measurement point the calibration procedure requires an external measurement device (see#5 in Table 2). Obtaining attenuation factors, in db, versus frequency for TBMM s metallic attenuator 1. Measure narrowband metallic output sending levels within defined stimulus frequency range at TCA s measurement point (75Ohm Rx) and respective metallic levels at the reference termination which shall be measured by external reference device, e.g. digital oscilloscope. Then, calculate attenuation factors versus frequencies and save the data into corresponding TCA calibration table 2. Compare obtained attenuation factors with defined limits The test is intended for calibration adjustment procedure and should be run before calibration of TBMM s longitudinal attenuators Longitudinal attenuation vs freq This calibration procedure is based on the TCA Script and should be performed under TBMM calibration conditions. The procedure calculates longitudinal attenuation versus stimulus frequency characteristic and compares obtained values 5

Purposes Notes Table 1 with limits for self-checking purpose. Obtaining attenuation factors, in db, versus frequency for TBMM s longitudinal attenuator 1. Obtain mathematic dependence between longitudinal and metallic voltage for well-known balance of the reference termination 2. Measure narrowband metallic output sending levels within defined stimulus frequency range at the TCA measurement point (75Ohm Rx) and calculate respective longitudinal levels at the reference termination by using previously estimated dependences. Then, calculate attenuation factors versus frequencies and save the data into corresponding TCA calibration table 3. Compare obtained attenuation factors with defined limits The test is intended for calibration adjustment procedure and should be run after calibration of TBMM s metallic attenuators. Calibration and verification procedures TBMM calibration hardware requirements In order to perform TBMM s calibration and verification procedures the calibration person should use reference terminations (RT) supplied with the measurement module and reference measurement device (RMD), e.g. a selective voltmeter or a digital oscilloscope (see Table 2) not supplied with TBMM. # Model Key specifications 1 Floating termination 100 Ohm HL Part number Resistance: 100 Ohm ± 0.1% Frequency range: 0 40 MHz 2 Unbalanced termination 25dB HL Part number Metallic impedance: 100 Ohm ± 1% Balance: 25 db ± 1 db Frequency range: 10 khz 40 MHz 3 Unbalanced termination 30dB HL Part number Metallic impedance: 100 Ohm ± 1% Balance: 30 db ± 1 db Frequency range: 10 khz 40 MHz 4 Unbalanced termination 35dB HL Part number Metallic impedance: 100 Ohm ± 1% Balance: 35 db ± 1 db Frequency range: 10 khz 40 MHz 5 Selective voltmeter / oscilloscope Active Differential Probe 6 Active differential probe LeCroy Model: AP 033 Table 2 LeCroy Model: LC584AL Model: AP033 1 GHz, 4 channels, High impedance; Selective measuring in 10 khz 40 MHz frequency range with 100 Hz window 500 MHz Bandwith 2 pf/side Input C Autobalance Feature Hardware requirements on the reference terminations and measurement devices being applied for calibration/verification purpose 6

TBMM Compliance testing Compliance Transverse Balance tests are located in TMBB 30M section of the Generic suite. All these tests are based on the respective Generic test and intended for compliance testing in accordance with respective standard. Limits of the measured values are set according to the ANSI/TIA-968-B standard. User suggested to create a User suite based on that test group and, if necessary, modifies test limits according to the tested standard. Tests existed in the group are: a. Transverse balance (100 Ohm; 50 khz - 12 MHz) purposed to verify the transverse balance of the EUT in the frequency range 50 khz - 12 MHz (Metallic termination Zm=100 Ohm, Longitudinal termination Zl=90 Ohm) b. Transverse balance (135 Ohm; 50 khz - 12 MHz) purposed to verify the transverse balance of the EUT in the frequency range 50 khz - 12 MHz (Metallic termination Zm=135 Ohm, Longitudinal termination Zl=90 Ohm) c. Transverse balance (100 Ohm; 50 khz - 30 MHz) purposed to verify the transverse balance of the EUT in the frequency range 50 khz - 30 MHz (Metallic termination Zm=100 Ohm, Longitudinal termination Zl=90 Ohm) d. Transverse balance (100 Ohm; 50 khz - 12 MHz) purposed to verify the transverse balance of the EUT in the frequency range 50 khz - 12 MHz (Metallic termination Zm=100 Ohm, Longitudinal termination Zl=90 Ohm) 7

HL 8240 hardware specification Transverse balance general parameters Test setup: According to: 5.3.2.2 TIA-968-B Fig.42 (FCC Part 68), CS-03 Part VIII clause 3.4, fig. 3.4(a) Frequency range: 50 khz 30 MHz Max measured Transverse balance: - 55 db in range 0.05 MHz 1.544 MHz; - 50 db in range 1.544 MHz 12 MHz; - 45 db in range 12 MHz 30 MHz Measurement uncertainty: Expanded uncertainty, k=2 (95% confidence): - Balance (6-25 db) @ 50 khz 12 MHz ±0.08 db; - Balance (6-25 db) @ 12 MHz 30 MHz ±0.13 db; - Balance (25-35 db) @ 50 khz 12 MHz ±0.11 db; - Balance (25-35 db) @ 12 MHz 30 MHz ±0.15 db; - Balance (35-45 db) @ 50 khz 12 MHz ±0.15 db; - Balance (35-45 db) @ 12 MHz 30 MHz ±0.75 db; - Balance (45-55 db) @ 50 khz 12 MHz ±0.45 db; - Balance (45-55 db) @ 12 MHz 30 MHz ±1.25 db; Metallic voltage (V M ): 0.2V - 0.75 V Reference metallic impedance 100Ω and 135Ω (include generator s impedance (Z M ): Reference longitudinal termination 90Ω (Z L ): Polarity: Normal (+) and Reverse ( ) Tracking Generator Frequency range: 12 khz to 35 MHz Frequency tuning resolution: 0.1 Hz Metallic voltage (V M ): 0.2V - 0.75 V, programmable Output: Balanced and floating Output GND connector: Floating Output protection: none Attenuator range: 0 15.5 db Attenuator resolution: 0.5 db steps Waveform: Sine from 10-Bit DAC DAC clock rate: 125MHz Amp. accuracy: 0.5 db Freq. accuracy: 0.001% 8

Longitudinal Voltage measurements Max. AC Voltage measured: Output port impedance: Min. Longitudinal Voltage measured: Metallic Voltage measurements Max. AC Voltage measured: Output port impedance: 0.1 V @ 12 khz to 30 MHz 50Ω (Balanced and floating) Limit: -80 dbv (BW=100Hz) @ (12 khz to 100 khz) Limit: -70 dbv (BW=1kHz) @ (100 khz to 2 MHz) Limit: -60 dbv (BW=1kHz) @ (2 MHz to 12 MHz) Limit: -50 dbv (BW=10kHz) @ (12 MHz to 30 MHz) 0.8 V @ 12 khz to 30 MHz 50Ω (Balanced and floating) USB interface Input: Type: Driver Support: Isolated from all exits excepting a power supply input USB 2.0 Full Speed (12 Mbits / Second) compatible Windows 98, 98SE, ME, 2000, Server 2003, XP, Windows Vista / Longhorn, Windows XP 64-bit Fixed voltage 5 VDC power supply Output voltage: + 5 VDC fixed 1A, floating Output Ripple, Noise: 50 mv p-p in 0 20 MHz Load regulation: ±5% Features: Double Insulated, Class B EMI, Low Leakage Current Safety Approvals: cul/ul, CE, TUV, C-Tick, SAA AC Input Voltage Rating: 100 to 240VAC AC Input Voltage Range: 90 to 264VAC AC Input Current: 0.25A (RMS) max. @ 120VAC 0.125A (RMS) max. @ 240VAC Leakage Current: 0.25mA max. @ 254VAC Input Power Saving: 0.5W maximum at no load Hold-up Time: 10mS min. @ 120VAC and max. load Circuit Protection: > 120%, auto restart Over-voltage Protection: > 120%, Zener Clamp Temperature Operation: 0 to +40 C Temperature Non-operation: -25 to +85 C Humidity Operation: 10 to 90% Emissions: FCC Class B EN55022 Class B Dielectric Withstand (Hi-pot) Test: Primary to Secondary: 3000VAC AC Input Clips (sold separately): US: RPA, Europe: RPE, UK: RPK, Australia: RPS Note: HL 8240 requires both 5 VDC of external power supply and from USB connector. 9