Cryogenic Systems and Receiver Maintenance

Similar documents
Ku-Band Receiver System for SHAO

Diseño del Criostato del Receptor de Banda Ancha

AVN Training HartRAO 2016

A Noise-Temperature Measurement System Using a Cryogenic Attenuator

VGOS MEMO #042 MASSACHUSETTS INSTITUTE OF TECHNOLOGY HAYSTACK OBSERVATORY WESTFORD, MASSACHUSETTS August 22, 2016

Micro-manipulated Cryogenic & Vacuum Probe Systems

suppose we observed a 10 Jy calibrator with CARMA for 1 year, 24 hrs/day how much energy would we collect? S ηa Δν t

NATIONAL RADIO ASTRONOMY OBSERVATORY CHARLOTTESVILLE, VIRGINIA. ELECTRONICS DIVISION INTERNAL REPORT No. 275 CRYOGENIC, HEMT, LOW-NOISE RECEIVERS

5 RECEIVERS TABLE TBD: EVLA RECEIVER FREQUENCY RANGES AND OPERATING TEMPERATURES

A SUBMILLIMETER SIS RECEIVER COOLED BY A COMPACT STIRLING-YT REFRIGERATOR

Detector Systems. Graeme Carrad

ngvla Advanced Cryocoolers For ngvla NATIONAL RADIO ASTRONOMY OBSERVATORY Larry D Addario, Caltech ngvlaworkshop, Socorro, 2017 June 26

A Method for Gain over Temperature Measurements Using Two Hot Noise Sources

Radio Telescope Receivers

Development of a Vibration Measurement Method for Cryocoolers

THE CRYOGENIC SYSTEM OF TESLA

SUPERCONDUCTING NANOTECHNOLOGY

Etude d un récepteur SIS hétérodyne multi-pixels double polarisation à 3mm de longueur d onde pour le télescope de Pico Veleta

Anne-Laure Fontana, Catherine Boucher, Yves Bortolotti, Florence Cope, Bastien Lefranc, Alessandro Navarrini, Doris Maier, Karl-F.

Signal Flow & Radiometer Equation. Aletha de Witt AVN-Newton Fund/DARA 2018 Observational & Technical Training HartRAO

C. Moore and T. Duribr ck SEPTEMBER 1971 NUMBER OF COPIES: 150

TESLA RF POWER COUPLERS DEVELOPMENT AT DESY.

Vibration-Free Pulse Tube Cryocooler System for Gravitational Wave Detectors II - Cooling Performance and Vibration -

Noise Calibration Systems and Accessories DATA SHEET / 4N-062

Improved Power Efficiency for Cryogenics at the Very Large Array

ALMA Interferometer and Band 7 Cartridge

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation. CXE880 Fibre node

Study towards cryogenic Phased Array Radar Systems

HIGH POWER INPUT COUPLERS FOR THE STF BASELINE CAVITY SYSTEM AT KEK

Influence of Temperature Variations on the Stability of a Submm Wave Receiver

System Considerations for Submillimeter Receiver

K band Focal Plane Array: Mechanical and Cryogenic Considerations Steve White,Bob Simon, Mike Stennes February 20, 2008 COLD ELECTRONICS

Physical Properties Measurement System (PPMS): Detailed specifications: Basic unit cryogen- free

Engineering Expertise for Space Communications

A Reduced Uncertainty Method for Gain over Temperature Measurements in an Anechoic Chamber

DESIGN AND CONSTRUCTION OF THE COSMIC MICROWAVE RADIOMETER

ALMA Band-1: Key Components, Cartridge Design, and Test Plan

WATERFLUX 3000 Quick Start

The Sardinia Radio Telescope conversion, distribution, and receiver control system

User Manual CXE Rev.002 Broadband Cable Networks March 3, (10) CXX Series. User Manual. Teleste Corporation CXE880.

The ALMA Front End. Hans Rudolf

WATER METERS M SERIES WATER METERS INSTALLATION, OPERATION AND MAINTENANCE GUIDE METAL M SERIES WATER METER PLASTIC M SERIES WATER METER

Liquid Helium Heat Load Within the Cornell Mark II Cryostat

EVLA Front-End CDR. Plans for S (2-4), X (8-12) & Ku (12-18 GHz) Receiver Bands

Q-SERIES. Optical. QFQR 200A-04 Series Return Path Optical Receiver. Installation & Operation Manual

More Radio Astronomy

EVLA Receivers PDR. (4m, P,) L, S, C BAND RECEIVERS. AuthorDaniel (Mert) Mertely

Receivers for. FFRF Tutorial by Tom Clark, NASA/GSFC & NVI Wettzell, March 19, 2009

ULISS DATA-SHEET. version c FEMTO Engineering, 15B Avenue des Montboucons, Besançon cedex

2 IN 1 18GA. NAILER/STAPLER KIT

RF power tests of LEP2 main couplers on a single cell superconducting cavity

Receiver Design for Passive Millimeter Wave (PMMW) Imaging

DEVELOPMENT OF A BETA 0.12, 88 MHZ, QUARTER WAVE RESONATOR AND ITS CRYOMODULE FOR THE SPIRAL2 PROJECT

NEWTON TRAINING (2018):

Frequency Tuning and RF Systems for the ATLAS Energy Upgrade. Gary P. Zinkann

Instruction Manual. For Type E Plasma Tube Electrodes

LOCALIZED LNA COOLING IN VACUUM

EVLA Front-End CDR. EVLA Ka-Band (26-40 GHz) Receiver

Subharmonic Mixer (SHM) Operational Manual

Phase calibration in prototype VLBI2010 systems

RTD-Style Hot Melt FoamMix Hoses for Bulk Melter Systems

Vibration measurement in the cryogenic interferometric gravitational wave detector (CLIO interferometer)

eye in hell CD 3002 Sensor Manual

A Low Noise GHz Amplifier

The Low-Noise, Integrated Transformer Helium-4 Dipstick Insert

MICROWAVE MICROWAVE TRAINING BENCH COMPONENT SPECIFICATIONS:

VLBI2010 Current status of the TWIN radio telescope project at Wettzell, Germany

RF STATUS OF SUPERCONDUCTING MODULE DEVELOPMENT SUITABLE FOR CW OPERATION: ELBE CRYOSTATS

Development of the accelerometer for cryogenic experiments II

Raytheon Stirling / PulseTube Cryocooler Maturation Programs

WATERFLUX 3000 Quick Start

GA A22776 THE DESIGN AND PERFORMANCE OF WAVEGUIDE TRANSMISSION LINE COMPONENTS FOR PLASMA ELECTRON CYCLOTRON HEATING (ECH) SYSTEMS

LOCALIZED LNA COOLING IN VACUUM

Tests of the Spoke Cavity RF Source and Cryomodules in Uppsala

The TWIN-Radiotelescopes Wettzell;

RECOMMENDATION ITU-R M * TECHNIQUES FOR MEASUREMENT OF UNWANTED EMISSIONS OF RADAR SYSTEMS. (Question ITU-R 202/8)

Energy Efficient Operation of 4 K Pulse Tube Cryocoolers

REVIEW OF HIGH POWER CW COUPLERS FOR SC CAVITIES. S. Belomestnykh

IF/LO Systems for Single Dish Radio Astronomy Centimeter Wave Receivers

12 TON HYDRAULIC SHOP PRESS. Instruction Manual. Please read this instruction manual carefully before use.

M5028 Precision Tuned Magnetron

Water Cooled Absolute Pressure Sensor

Cold-Head Vibrations of a Coaxial Pulse Tube Refrigerator

Cryogenics for Large Accelerators

Rabbit Series Laser Engraving Machine HX3040. User s Manual. 1 Jinan King Rabbit Technology Development Co. Ltd.

Model LS 250 Loop Scanner Operator s Manual. Version

Noise by the Numbers

SAFETY INSTRUCTIONS. WARNINGS Always read tool manual before operating.

Next Generation Space Atomic Clock Space Communications and Navigation (SCaN) Technology

THE C-130 UV HYGROMETER FIELD MANUAL

Submillimeter (continued)

Dinesh Micro Waves & Electronics

RECTANGULAR WAVEGUIDE TERMINATIONS 80 SERIES

SERVICE INSTRUCTIONS Model 9670 Lubricant Pump

MMA Memo 143: Report of the Receiver Committee for the MMA

C-W1650S 16 Ga, 1 Wide Crown Stapler

Microwave Radiometer Linearity Measured by Simple Means

Third Harmonic Superconducting passive cavities in ELETTRA and SLS

caroma marc newson wall basin mixer

NUMBER OF COPIES: 60 Rerun November 1963: 100

Transcription:

Cryogenic Systems and Receiver Maintenance Christian Plötz Email: christian.ploetz@bkg.bund.de Federal Agency for Cartography and Geodesy Geodetic Observatory Wettzell Germany

Objective Provide basic knowledge of a typical Cryogenic system with a low noise receiver used in geodetic VLBI Why a low noise receiver is required Cryogenic system necessary to operate amplifiers in low noise operating region Operation and maintenance of low noise receiver Practical suggestions for maintaining cryogenic low noise receivers 2

Agenda The following topics will be discussed: Why accurate measurements of receiver noise temperatures are important Noise diodes and calibration of the receiver system An overview of the Cryogenic system within the VLBI system Basic maintenance, repair and replacement of Cryogenic parts 3

Introduction Why receiver noise temperatures are important? The incoming signal from the astronomical radio source is much smaller than the noise from: Receiver Background Atmosphere First amplifier element of the receiver signal path contributes the greatest amount of the system noise power 4

Introduction Cascaded amplifiers Signal to noise ratio Friis formula for noise temperature: T E = T 1 + T 2 G 1 + T 3 G 1 G 2 + + T n G 1 G 2 G n 1 5

Introduction Cascaded amplifiers Signal to noise ratio Receiver noise factor is dominated by the first amplifier Usage of HEMT amplifiers HEMT: Hyper Electron Mobility Transistor Very high bandwidth possible 6

Introduction LNA By using cryogenic HEMT LNA s we achieve the lowest receiver noise contribution, e.g. 15 K ( @20Kelvin ) versus 150 K ( @300K ) Extremely low power levels of received signal, a small percentage of the receiver noise contribution The typical LNA used in VLBI and Radio Astronomy usually detects broad band Gaussian noise signals from very distant sources such as quasars 7

VLBI Scheme Analog S-/X-band System Frontend Radio telescope Backend operations room Radio frequency (RF) Intermediate frequency (IF) Base band (BB) Analog domain (-40 dbm) Digital domain (1bit/2bit) Horn / Wave guide x Az/El Cable wrap x VLBI - Formatter Data recorder Pcal- Pulse 1 Mhz/ 30 ps cryogenic S-/Xband first amplifier (@20 Kelvin) LO S: 2020 MHz X: 8080 MHz Cable length Appr. 100 m 16 x (LO-BB) 80-720 MHz 5 MHz LO UTC-Epoche: 1 Pulse/Sec. (from GPS) Pcal- System Phase and noise Calibration system Antenna unit cable -calibration cable 5 MHz and 5 khz 4.995 MHz Cable and Pcal- System 5 MHz 5 MHz Hydrogen -Maser df/f ~ 10-14 Phase calibration and cable - Ground module in operations room ultra-precise referencefrequency LO: local oscillator 8

An overview of the Cryogenic system Basic cryogenic system consists of a helium compressor, interconnecting high-pressure hoses, cold head / refrigerator, vacuum Dewar and related interconnecting cables The compressor compresses the helium gas, extracts the additional heat by compression (heat exchanger) and raises the operating pressure of the helium supply to the refrigerator The helium gas moves from the compressor (high pressure or supply side) through the hoses to the cold head and flows back via the return line to the compressor 9

An overview of the Cryogenic system The cold head extracts the heat from the Dewar cooling the inner parts of the Dewar to 20 Kelvin The standard VLBI Dewar contains the X- and S-band LNA s Helium is circulated through the Dewar via cylindrical displacers The helium returns to the compressor (low pressure or return side) through lines of the same type as the highpressure side 10

Cryogenic System scheme Aeroquip connectors 11

Cryogenic System scheme E.g. Model CTI Brooks 8200: Static pressure 245-250 psig (1690-1725 kpa) within 16 to 38 C) Nominal operating pressure: 270-290 psig (1860-2000kPa) 12

Helium compressor E.g. Model CTI Brooks 8200 ( ) used in Wettzell for the 20 m radio telescope: Air cooled Static pressure 245-250 psig (1690-1725 kpa) within 16 C to 38 C Nominal operating pressure: 270-290 psig (1860 kpa to 2000 kpa) 13

Helium compressor Important for operation and maintenance: Correct Helium pressure range Ambient temperature range Replacement of Adsorber (after 1 year permanent operation) Helium flex lines with areoquip connector in a good and clean condition Cooling fan works and is clean 14

Cryocooler and Dewar In order to reach cryogenic temperatures, a vacuum chamber (DEWAR) containing the receiver is evacuated to a very high vacuum, and a closed cycle refrigerator is used to remove the heat Types of cryostats: Closed cycle: Using cold heads (He gas, 77K and 20K) Open cycle: (Liquid N: 77K, liquid He: 4K) Hybrid: cold head + liquid He filling: 0.35 K with He-3 15

Cryocooler cold head Cold head Gifford McMahon (GM) coolers: Widely used for cryocooling the first LNA stages Temperatur reached < 20K 16

Cryocooler selection Most important: Cooling capacity Thermal conduction and radiation loading at the intermediate and cold stage Convection is negligible if pressure is better than 10-5 mbar Total cooling power Wtot = Wcond + Wrad + Wgas + Wdiss 17

Cryocooler selection Thermal load due to conduction W cond = A l λ T 2 T 1 A : cross section area of the conducting element L : conducting element length λ Thermal conductivity of the material (between T 2 and T 1 ) T 2 : Hot stage temperature T 1 : Cold stage temperature Conclusion: Material with low thermal conductivity, small cross section and long. (e.g. stainless steel) 18

Cryocooler selection Thermal load due to radiation W rad = Fe FF σ A 1 *(T 4 2 T 4 1 ) Fe : Emissity factor FF: Configuration factor (depends on geometry) σ: Boltzman constant T 2 : Hot stage temperature T 1 : Cold stage temperature A 1 : Area of inner surface A 2 : Area of outer surface ε 1, ε 1 : emissivity of the surfaces 19

Cryostat performance Most important considerations of the performance of the refrigerator: Temperature reached and maintained Degree of vacuum achieved Maintainability Refrigerator selection, choice of materials for the vacuum chamber walls and internal components, fabrication techniques, cleaning procedures and evacuation procedures are important considerations affecting reliability 20

Dewar scheme Different elements inside the Dewar: Vacuum window Thermal transition IR filter (blocking thermal radiation from outside) LNA (Low noise amplifier, e.g. for S-Band and X-Band) Directional coupler (for input matching S11) Polarizer Feed horn / Corrugated horn / Waveguides / Hybrids Cables (DC and RF) Housekeeping elements (heaters, vacuum traps, temperature sensors) 21

Example of internal parts of a Dewar Heating resistor 22

Example of 20 m Wettzell S-/X-band Dewar 23

Why receiver noise temperatures are important? Each radio source emits power, which is quantified by the unit of measure Flux Unit (FU) and is described as detected rise in system noise power Measured in units of Jansky [10 26 Watt m 2 Hz ] System temperature (Tsys) is expressed in Kelvin (K) Important for VLBI operation as indication that all is fine Important for analysis (see e.g. gain calibration) 24

Noise diodes and the receiver system Noise diodes provide the standard by which the received flux of an astronomical radio source is compared This calibrated noise power from the Noise diode is added to the system s overall detectable power to allow measurement by substitution of the Antenna and receiver noise to provide the accurate measurement and calibration of system temperatures This is what is generally called noise calibration (caltsys procedure in the NASA Field System) 25

Noise diodes and the receiver system Methods to inject noise to the receiver: Radiated using another feed in the antenna optics Directional coupler: preferred method (just after the feed, before the LNA. Problem: This has losses and increases T rx Two methods for switching the noise diode: Continuously with 80 Hz Switched on and off (e.g. system temperature measurement by the NASA Field System) 26

Techniques used to measure receiver noise temperature There are many methods for measuring receiver noise temperatures. The following technique is both practical and accurate. This is generally called Y factor method. This measurement will use a cold sky (a sky with as few noise sources as possible) and an absorber (such as Eccosorb ). The sky will provide the cold reference ~3K while the absorber acts as a hot termination of ~290K. 27

Techniques used to measure receiver noise temperature The procedure for calibrating the receiver is as follows: Point the receiver feed straight up at the sky (zenith angle) or use an aluminum reflector about 1 meter square at a 45 degree angle to reflect noise from the cold sky into the feed. The angle should be adjusted to give the lowest possible power output from the receiver IF). 28

Cold-sky-ambient aperture load noise measurement system 29

Steps: Cold-sky-ambient aperture load noise measurement system 1. Y (dbm) = P hot (dbm) P cold (dbm) 2. Y = 10 ( Y 10 ) 3. T rx (K) = (Th Y Tc) Y 1 Where T rx is the receiver noise temperature Tc is the temperature in Kelvin of the cold sky, about 10 Kelvin for a clear sky and about 20 Kelvin for an overcast sky 30

Would you like to read more about it? An excellent discussion of Noise Temperature Measurements may be found in the IPN Progress Report 42-154. Authored by C. T. Stelzried, R. C. Clauss and S. M Petty Link: https://ipnpr.jpl.nasa.gov/progress_report/42-154/154g.pdf 31

The importance of Cryogenics in receiver systems Noise contributed by internal noise of the Low Noise - Amplifier (LNA) can be greatly reduced by cooling the LNA to an low physical temperatures. Thermal-Electric cooling can obtain 230 K. To make real gains in performance the use of cryogenic Gifford McMahon cryocooler cycle will lower the operational temperature of the LNA to 20K. The overall effect of the cryogenic cooling is a >10 fold improvement in system temperature and thus system sensitivity. 32

Sources of Cryogenic parts Examples of cryogenic suppliers: http://www.trilliumus.com/cryogenics.html This Company is a supplier of CTI cryocoolers and compressors. http://www.shicryogenics.com This Company is a supplier of cryogenic equipment (e.g. Sumitomo cold head and compressors) 33

Basic maintenance, repair and replacement of Cryogenic parts Refrigerator Replacement If cold head fails or cold head reached operational lifetime (>2 years) the preferred option is to exchange the complete coldhead displacer cylinder or you can dismantle the coldhead displacer from the cylinder: Important! Delicate task. Working with gloves, grease where necessary. You need some experience! When opening the cold head from cylinder there may lead dust be freed up! 1. Attach the charging adaptors to both helium ports. 2. Open both adaptor valves to discharge the pressure from the refrigerator. Remove charging cylinder. 3. Remove the four #10 Hex head screws securing the refrigerator to the cylinder and withdraw the refrigerator, thus removing the displacers from the cylinder. 4. Perform steps 1 through 3 on the replacement unit. 5. Carefully place the second stage seal suppressor over the seal on the replacement unit. 34

Basic maintenance, repair and replacement of Cryogenic parts Refrigerator Replacement 6. Clean the inside of the cylinder in the Dewar with a suitable solvent (petroleum ether is preferred, however, alcohol can be used). Make sure that the cylinder is completely clean and dry before proceeding. 7. Clean the O ring grove on top of the cylinder and install a new O ring coated very lightly with apiezon grease. 8. Carefully insert the displacers into the cylinder until the crosshead mates with the cylinder and bolt in place using a crossed pattern tightening procedure which insures that the bolts are tightened evenly. 9. Perform steps 1 through 6 of the system purging procedure. 35

Refrigerator Purging and Pressurization Procedure Once this procedure is performed the helium gas contained in the compressor, hoses and refrigerator will be of the high purity (better than 99.999%, Helium 5.0) Read your manual of your cold head and compressor! Example procedure: 1. In order to get a successful purge of the system the helium lines must be removed from the refrigerator when the system is as cold as possible. Trapping the contamination in the refrigerator. Disconnect while running the supply line and then immediately the supply line to the compressor. 2. Allow the refrigerator to warm to room temperature before proceeding. 3. Attach purging and charging adaptors to both the supply and return helium lines on the refrigerator. 36

Refrigerator Purging and Pressurization Procedure 4. Attach a regulated supply of ultra pure helium to the charging adaptor on the supply side of the refrigerator and adjust the regulator pressure to 50 PSI. 5. Apply electrical power to the refrigerator by attaching the cable from the compressor and turning on both switches on compressor. 6. Open the valves on both charging adaptors and allow helium to flow through the refrigerator for at least one minute. 7. Close the exhaust valve on the return side of the refrigerator and allow the pressure in the refrigerator to equalize. 8. Close the valve on the supply side of the refrigerator, the supply valve on the helium tank and remove the charging adaptors. 9. Return the normal helium line connections to the refrigerator and begin a normal cool down cycle as the refrigerator is now ready for use. 37

Resulting benefits from this presentation From this presentation you should have a better understanding of the following: Noise temperature and it s relevance to the VLBI receiving system Procedures for calibration of the noise diodes Procedures for the calibration of the receiver The use of cryogenics in the receiver system Procedures for replacing the refrigerator Procedures for purging the pressurizing the refrigerator 38

Important rules Make sure that the Helium gas is of highest necessary purity Observe rigorously the purging procedure for all gas connections and manifolds used when connections are made Keep gas and vacuum fittings clean Dirt (e.g dust, hairs, fibres, other debris) on connectors and vacuum surfaces could cause leaks and malfunction Use dust caps or similar always to protect open connectors and fittings Before assembly inspect visually connectors and fittings Clean connectors and fittings with lint-free material wipes Wear gloves (e.g Nitril gloves) when handling vacuum exposed surfaces and cryogenic components Avoid surface contamination 16.05.2017 39

Important rules Very important: Never break a vacuum isolation of a cold system Always store a Dewar under vacuum condition Vacuum valve of the Dewar should never be touched unless the vacuum pump is connected Start up the vacuum pump before opening the valve If the vacuum is lost by accident connect the vacuum pump as soon as possible and pump the Dewar until the temperature is above 293 Kelvin Do not disturb the installation more than necessary Repeated disconnection and re-connection of gas may lead to gas loss and possible contamination 16.05.2017 40

Thanks for your Attention! Questions? Please email to: christian.ploetz@bkg.bund.de 41