PD 3 Dowel Cradle. Load Transfer System Industrial Slab on Ground

Similar documents
Flanged Dowel Box. Load Transfer System INDUSTRIAL SLAB ON GROUND

Diamond Dowel. Load Transfer System INDUSTRIAL SLAB ON GROUND

Hyper ArmourMate. Joint Edge Protection INDUSTRIAL SLAB ON GROUND

Plate 60 ArmourMate. Joint Edge Protection INDUSTRIAL SLAB ON GROUND. Plate 60 AmourMate. Joint Edge Protection

PD 3 POD PRODUCT CATALOGUE. Load Transfer and Floor Joint Systems. New Zealand. July 2016 Issue. DIAMOND DOWEL PD3 DOWEL CRADLE

Slab-on-Ground Industrial, Residential and Pavement Systems PRODUCT CATALOGUE. Australia 2017 Issue.

Double Bar Plate Dowels for Saw-Cut Contraction Joints

TECHNICAL MANUAL. OPTIMAJOINT Free Movement Joint. Free Movement Joint System for Heavy Traffic

Plate Dowels. An Innovation Driven by Industrial Concrete Paving. Introduction

Dowel. Design. Performance-Based World of Concrete Official Show Issue. Lift-truck design changes require a new look at joint durability

A Solution to Cracking and Stresses Caused by Dowels and Tie Bars

PERFORM WITH PRECISION WELDED DOWEL ASSEMBLY LOAD TRANSFER PRODUCTS CONCRETE CONSTRUCTION SOLUTIONS BROCHURE

TECHNICAL MANUAL. TERADOWEL and ULTRADOWEL. Reliable Dowel System for Floor Joints

AMENDMENTS Manual of STANDARD SPECIFICATIONS. Adopted by Standard Specifications Committee. Amendment. No. 6. Published by

R&T UPDATE. An Alternative to Traditional Round Dowel Bars Plate Dowel Innovations Driven by Industrial Concrete Paving

Frequently asked questions about our armoured joint with disruptive face technology.

Installation Guide. Capped Cellular PVC Fencing. Table of Contents. Storage and Handling Tools Needed Fence Layout and Locating Posts

SECTION CONCRETE REINFORCEMENT FOR STEAM UTILITY DISTRIBUTION

Slope Floor. Measurement Methods

1. CONNOLLY KEYJOINT 1. PRODUCT NAME 2. SUPPLIER 3. PRODUCT DESCRIPTION 4. KEY FEATURES 5. FIXING INSTRUCTIONS 6. SPECIFICATIONS 7.

Initiating Cracks in PCC Pavements. Malcolm K. Lim, PE

Session 8: Load Transfer Restoration. (Dowel Bar Retrofit, Cross-Stitching, and Slot Stitching)

MANHOLES PART I: GENERAL. A. Precast Concrete Manholes

Section 914. JOINT AND WATERPROOFING MATERIALS

4.1. Foremen 4.2. Concrete plant manager 4.3. Concrete plant operator 4.4. Personnel performing saw cutting and joint sealing

SHADOWBOX INSTALLATION FOR: Standard 6 H x 8 W Shadowbox Fence 5 x 5 Routed Posts Dog Ear or Straight-Edge Pickets 1.75 x 3.5 Rail

Dowels for the 21st Century

PRIVACY INSTALLATION FOR: Standard 6 H x 8 W Privacy Fence 4 x 4 Post Sleeve & Brackets Dog Ear or Straight-Edge Pickets 1.75 x 3.

CertainTeed INSTALLATION GUIDE SIMTEK FENCE PRODUCTS. Fence Installation Guide 3', 4' & 6' High

KEITH PANEL SYSTEMS FUNDERMAX- MAX EXTERIOR EXPOSED FASTENER PRESSURE EQUALIZED WALL SYSTEM

² TL Beton-StB 07 = German technical conditions for construction materials for concrete road pavements

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 2007 EDITION

Why Do We Saw Equipment Types Matching Equipment to the Project Blade Selection Ensuring Construction Quality When Things Don t Go Right The Sawing

Table 5G-2.01: Transverse Joint Requirements. Transverse Joint Type 6 C 12 7 C 15 8 CD CD CD 1 20

Jointed Precast Concrete Pavement

Design and Construction of Highway Pavement Joint Systems

SECTION PRECAST CONCRETE SECTIONAL MANHOLES

Product Guide Specification

PRECAST CONCRETE STRUCTURES

CONSTRUCTION SPECIFICATION FOR MAINTENANCE HOLE, CATCH BASIN, DITCH INLET, AND VALVE CHAMBER INSTALLATION

IGGA Guide Specification: Dowel Bar Retrofit (DBR) Introduction

CIC 200 PLASTIC SCREW ANCHOR ASSORTMENT WITH PHILLIPS BINDING HEAD METAL SCREWS. 6 x 3/4 P/N x 1 METAL SCREW P/N x 3/4 METAL SCREW

Design of structural connections for precast concrete buildings

HSD-LD-US 06/13 Page 1/5. Components

A. Extent of structural precast concrete work is shown on drawings and in schedules.

A Shell construction

2. Sanding the Modules Sand the entire surface of each cyc module with 60-grit sandpaper. This will provide for better paint adhesion.

C-M TMR Products Index

Storefront Installation Guide

Dowel Bar Alignment and Location for Placement by Mechanical Dowel Bar Insertion

Fast Track Precast Concrete Pavement Rehabilitation Pilot Project

Reinforcing Mesh Product Guide

Edgerail Aluminum Bridge Railing System Specification & Installation Instructions

P r o d u c t D e s c r i p t i o n

Suitable for panels up to 12 tonne. No sharp edges. Lighter than comparable capacity systems. So, why the need for change?

FENCE INSTALLATION GUIDE 8 HIGH WALLS

JVI Vector Connector

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION

GOLDEN RULES FOR EASIFIX INSTALLATION

Glulam Connection Details

Innovative composite dowel for steel concrete composite bridges. Neil Westmacott, Wolfram Schwarz

Installation Guidelines

ACORNWIRE.COM MESH PARTITIONS DIVISION 10 - SPECIALTIES WIRE MESH PARTITION FOLDING GATE

EKSPAN. Standard F Series Bearings. Description. Bearing types F series bearings are available in three forms - Typical 21F details.

PRO CYC PRO CYC, INC. SYSTEM SUPER 1.5 EZ

Reinforcing Mesh Product Guide

SOFRASAR TUNNEL PRODUCTS CONNECTING ALL COMPONENTS

Manholes Table of Contents

PRO CYC PRO CYC, INC. SYSTEM SUPER 3EZ

Schöck dowel Type SLD plus

MH Table of Contents Standard Title/Scope Page Table of Contents SCE Public

GENERAL ISOMETRIC LAYOUT

KEITH PANEL SYSTEMS FUNDERMAX- MAX EXTERIOR CONCEALED FASTENERS PRESSURE EQUALIZED WALL SYSTEM

Segmental ring types provided by F P McCann: Segments in stock are front bolted. Back bolted segments are available to order: Cross joint Corbel Ring

Cablelink Plus Flush Technical

Meva Guided Screens MGS Technical Instruction Manual

SteelChief Installation Instructions for pre-assembled panel form sheds GABLE ROOF

connecting the world PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Installation Instructions. Tools Needed. Tape measure. Level. Shovel or Post hole digger. Concrete. Drill. Stakes. Mallet or hammer.

PINEHAVEN SHEDS Assembly Instructions FOR LEAN-TO SHEDS

WALL TO FABRICATED FLOOR

installation care & maintenance instructions lifecycledecking.com 25-year limited residential warranty 20-year limited commercial warranty

Chapter 17 - Porch Trim

4256HM JAMES HARDIE MONOLITHIC CLADDING

CARES Technical Approval Report TA1-B 5042

PCCP Preservation Steps to Take to Extend Pavement Life and Performance of Your Concrete Pavements

Series 1600 WeatherGuard Dock Enclosure

FENCE INSTALLATION GUIDE 6 HIGH FENCE

2018 Product Catalogue

PERFORM WITH PRECISION

Football Goals 7,32x2,44 m

ATLANTIS RAIL Contact Information

Installation and Assembly: Flat Video Wall Mount For 40" to 65" Flat Panel Displays

182.1 INTRODUCTION SERIES 462 ARCHITECTURAL COMMERCIAL SLIDING WINDOW. Design Features : Australian Registered Design.

SECTION ARCHITECTURAL PRECAST CONCRETE

Experience the Hi-Lite Advantage

Precast Concrete Pavement Background Concepts. Project 1517 FHWA, CTR & TxDOT Gary Graham November 15, 2001

PET*STAR 4 OPERATOR MANUAL

15mm Solid European Droploc Oak Fitting Guide & Warranty Information

2013 Feeney (2/14) # B. Aluminum Railing Systems

Transcription:

PD 3 Dowel Cradle Industrial Slab on Ground Provides the flattest joints Assists in reducing long term maintenance costs Extends the life-cycle of the floor and the asset Engineered to meet Super Flat Floor (SFF) requirements, ACI 360-R10

Product Description The patented PD³ design features a tapered and sleeveless plate dowel that provides the world s best performance in limiting joint deflection to provide superior joint stability. The PD³ Dowel Cradle provides the highest deflection control tolerance in line with ACI Standards recommendations to limit joint spalling, facilitate load transfer and provide the lowest risk of restraint to ensure the best serviceability outcome for the slab design. The use of the PD³ system extends the life-cycle of the floor to provide the highest level of floor efficiency for tenants and the highest return on investment for the asset owner. PD³ Dowel Cradles are designed to provide a total contraction joint system solution by incorporating two systems in the one solution. The tapered PD³ dowels that allow for lateral movement eliminating the need for a plastic dowel sleeve and the wire cage that acts as a chair and spacer to ensure the dowels are aligned and maintained at the correct height and spacing during the pouring of the slab. The elimination of the plastic sleeve from the dowel ensures direct concrete to steel contact which provides the best possible control of load deflection by eliminating the crush factor of the plastic and providing a tighter control tolerance than other sleeved plate dowel systems. Slab Deflection Dowel Plate to Concrete Direct Contact The PD³ Dowel Cradle tapered shape allows for the lateral movement of the dowel without the need for plastic sleeves to create cavities. The absence of a plastic sleeve allows direct contact between the steel plate and the concrete therefore providing minimal chance of deflection, greatly reducing the risk of damage to the joint edges. Sectional View of PD³ Dowel Cradle Deflection <=0.25 to meet ACI 36O-R10 Sectional View of Standard Plate Dowel Cradle Possibility of 3.4 mm deflection Plastic sleeve crushes under load Please Note: These drawings are not to scale but illustrational to highlight potential load deflection. ( 1 ) Features 1. The PD³ Dowel Cradle features a plate dowel with bond breaker allowing concrete to steel contact. 2. The PD³ Dowel Cradle utilises a tapered plate dowel that allows lateral movement without the use of a plastic sleeve. 3. The wire cradle construction ensures the accurate placement and alignment of the plate dowels at the correct centres and height within the slab. Advantages No plastic sleeves required. Direct steel contact allows superior load deflection control. Engineered to meet Super Flat Floor (SFF) requirements, ACI 360-R10. The use of the PD³ Dowel Cradle creates a lateral and longitudinal movement void. Reduces the risk of restraint. Provides fast and accurate horizontal and vertical placement. PD³ Dowel Cradles superior engineered performance controls floor flatness limiting joint spalling. Benefits Concreter Benefits Speed and accuracy of dowel placement. Lowest placement cost. Ensures the flattest floors at the joint. Pour through capability. Greater stakeholder satisfaction. Asset Protection Benefits Reduces the risk of spalling damage to the concrete at the joints. Reduces floor maintenance and downtime costs over the life-cycle of the facility. Reduces wear and tear on tenants materials handling equipment. Engineering Benefits Provides highest performance in controlling joint deflection. Compliance with ACI 360-R10, design recommendations. Delivers flatter joints, FF and FL, ACI 117. Accuracy of dowel placement ensures the most effective load transfer performance. Provides a smoother floor surface at the joints which ensures tenant efficiency. Increases tenant satisfaction and return on investment.

Lateral Movement Of Dowels (Plan View) - How PD³ Dowels provide lateral and longitudinal shrinkage Panels shrink diagonally from corners. If the left side panel shrinks more than the right side panel differential shrinkage needs to be accommodated ACI 360-R10 States (Chapter 6.2 - Load Transfer Mechanisms) Joint and crack stability measurements below 0.25 mm for joints or cracks subjected to lift truck traffic with small hard wheels will have good service life As the panels shrink, a small void is formed in the concrete by the tapered dowel, allowing for differential parallel shrinkage Joint opens up due to slab shrinkage Tapered PD³ Dowel (dowel orientation alternates) Mesh Reinforced Slab Design - Typical Install Slab height Early entry sawcut (¼ slab depth) with non-compressible epoxy joint filler Reinforcing mesh supported by bar chairs (⅓ the slab cover) ½ Slab height (±5%) Material Technical Data COMPONENT DIMENSION (mm) MATERIAL TYPE MATERIAL STANDARDS STEEL GRADE EQUIVALENT YIELD STRESS (MPa) TENSILE STRENGTH (MPa) STANDARDS COMPLIANCE 6 mm Dowel 6 x 300 Cold Drawn Steel Q345 Grade 300 345 550 AS/NZS 3679.1 10 mm Dowel 10 x 300 Cold Drawn Steel Q345 Grade 300 345 550 AS/NZS 3679.1 Wire Cage Hard Drawn Wire AS/NZS 4671 Grade 500L 500 650 AS/NZS 4671 Travel Bars Ø4 Ribbed Wire AS/NZS 4671 Grade 500L 500 625 AS/NZS 4671 Manufacturing Tolerances (Standard Sizes) OVERALL LENGTH ±10 mm OVERALL HEIGHT ±5 mm DOWEL CENTRES ±5 mm ( 2 )

Installation Guide Correct Cradle installation: 1. Saw-cut approximately ¼ of slab depth. 2. Dowel height at ½ slab height. 3. The mesh should be supported by bar chairs to rest approximately ⅓ of the slab height. 4. Bar chairs should keep the mesh parallel at consistent depth. 5. Bar chairs should be as close to the cradle as practical. 6. Mesh should not overhang past the edge line of the cradle. 7. Mesh should not touch the edge of the cradle, allowing concrete flow between the mesh and the cradle. Incorrect Cradle Installation: 1. Mesh is too close to top surface of the slab. 2. Mesh is too close to the line of the saw cut. Saw-cut too shallow to be effective, the crack has not generated from the top of the slab therefore the crack has found its own path to the surface. Saw-cut too deep, the load transfer system has been cut and therefore has rendered it ineffective in controlling deflection. ( 3 )

Installation Process Step 1. installation Tools Required: Mark Out Paint Hammer Wire Cutter Step 3. installation Installation Mark out joint lines on sub-grade with mark out paint to allow straight and accurate placement of PD³ Dowel Cradles. Place cradles along mark out lines with the PD³ dowel centred over joint line. Place cradles end to end ensuring dowel spacing is maintained at correct specified spacing. Cradles can be cut to provide infill lengths. Optional Danley Hold Down Stakes can be used to secure the cradles in position for the pour. Important: Do not run cradles through intersections. See intersection positioning diagrams below for correct layout. Step 2. installation The mesh should be supported by bar chairs to rest approximately ⅓ of the slab height. Make sure mesh is placed back from the joint line (in line with the edge rail of the cradle), do not place directly on the cradles. Pour through concrete, ensuring that both the cradles and the reinforcement are not displaced. Step 4. installation Prior to the pour, cut the 4 mm travel bars (3 cross wires that hold the wire frames together). Failure to do so may lock the joint. Form the joint with a soffcut (¼ slab depth) as soon as the concrete will support the saw and operator. This is usually within 2-4 hours of the last pass of the power trowel. Dowel Application Key Points Dowels are needed to reduce the differential deflection between adjacent panels so that lift truck wheels do not create joint spalling resulting in high maintenance and rectification costs. Joint spalling is the critical failure mode of the joint. Joint systems should be designed for serviceability (rather than ultimate load). Dowel selection should be based on the floor flatness tolerance required. PD³ Dowel Cradle Positioning 3-Way Intersection Detail Control of deflection and cracking without reducing slab strength should be the key design factor. Concrete strength is generally the controlling factor after the deflection control considerations. The dowel systems should never introduce risk of restraint and uncontrolled cracking at any time. 4-Way Intersection Detail Oversized and over strength dowel systems raise the risk of concrete bursting. Dowel systems should maximize the load at the slab edge and minimize the bursting risk past the joint. Danley Systems consider the correct type and amount of doweling required to control deflection for the type and rated capacity of the lift truck to be used. Standard Length Detail ( 4 )

How to write a Specification Product specification for PD³ Dowel Cradle consists of: PRODUCT CODE, Dowel Thickness, Dowel Centres, Slab Height and Finish (Black or Galvanised) e.g: PD306450150B Specification REQUIRED INFORMATION For quoting or manufacturing the following formation is required: Danley Product Code Dowel Thickness Dowel Centres Slab Height Dowel Finish B/Galv. P D 3 0 6 4 5 0 1 5 0 B Plan View Standard cradle length 3000 mm Centres as specified Dowel positions alternate Travel bars to be cut before pouring concrete Section At Contraction Joint Standard dowel length 300 mm Early entry sawcut (¼ slab height) Slab height ½ Slab height Standard dowel options 6 mm or 10 mm ( 5 )

PD³ Dowel Cradles can be easily cut to required lengths or butted together to form large runs and Intersections PD 3 Dowel Cradle Panel Layout Construction Joints ArmourMate or loose dowels (Diamond Dowels) positioned around the perimeter of each concrete pour. Contraction Joints PD³ Dowel Cradles positioned at the soffcut joint lines. Typical 30 x 30 meter slab panel. ( 6 )

Companion Products 1. 1. ArmourMate For edge protection of construction joints, Danley ArmourMate provides a range of solutions to best prevent damage and joint spalling associated with impact from materials handling equipment and other traffic. Joint edge protection systems can be incorporated into Danley full joint solutions with sacrificial formwork and load transfer systems. 2. Diamond Dowel 2. Diamond Dowels are plate dowels suited for construction joints in concrete slabs and pavements. They transfer vertical loads across the joint and minimise differential deflection between adjacent slab panels under load. Easy to install they attach directly to wooden formboard or metal separation plates. They come pre-packaged with all components ready for installation. 3. Crack-A-Joint As an option to saw cutting, place Crack-A-Joint into the wet concrete along the joint line (above the centre of the PD³ Dowel Cradle), to induce a crack for the full depth of the concrete. The Crack-A-Joint is available in standard 3 m lengths formed from galvanised sheet steel to a height of 25 mm. It can be supplied as a plain joint or with a permanent Rip-A-Strip capping in three different colour options (Black, Grey or Sandstone). 3. 4. Ground Crack Inducer An inverted V-shaped PVC extrusion, 3 m long and available in 25 mm and 50 mm heights. It is positioned on the subgrade before the PD³ Dowel Cradles are placed. It produces a weakening in the slab that initiates a crack from the bottom up. Ground Crack Inducer is optional and should only be used when Crack-A-Joint is used, or when saw cuts are to made in the slab on the same day as the slab is poured. 5. Cradle Hold Down Hook 4. A small optional wire hook that allows you to anchor the base of your Cradles into the site sub-base. It prevents the PD³ Dowel Cradles from moving during the pour process. They hook over the bottom wire of the Cradles securing them to the ground. 1300 DANLEY (1300 326 539) www.danley.com.au sales@danley.com.au 5. Other related ITW Construction Systems brands Rev 1 - April 2015 Innovative engineered solutions for the concrete construction industry with specialty in the design of precast and tilt-up. Market leading brands that include Swiftlift TM Concrete Lifting solutions, Reidbar TM Threaded Reinforcing, Nirvana TM Insulated Panel System and a range of Architectural Concrete products. www.reid.com.au www.reids.co.nz Expansion Joint systems for civil and architectural specification that includes Floor, Wall, Roof, Facade, and Seismic engineered solutions for Retail Centres, Multi-level Carparks, Hospitals, Bridges and most other suspended slab environments. www.miska.com.au Manufacturing one of the largest ranges of plastic concrete accessories, bar chairs and spacers, as well as components for formwork and precast. Working closely with end users, Modfix has continued to assist in the development of new, cost effective solutions for the building and construction industries. www.modfix.com.au www.itwcsanz.com info@itwcsanz.com Disclaimer: The information contained in this publication is intended to give a fair description of the products and their capabilities. No responsibility or liability by the manufacturers will be accepted for misuse, misreading or deviation from the recommended guidelines of these products. As new technology is introduced, or industry standards are altered, ITWCS reserves the right to alter the information without notice.