Brief description. Type overview

Similar documents
Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Functional data Factory settings Variable Settings

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data. Safety notes. T3-LR24A-SR en v Subject to changes 1 / 2

Power consumption In operation At rest For wire sizing. 1.5 W at nominal torque 0.4 W 4 VA Connection Cable 1 m, 3 x 0.75 mm 2

Technical data. Parameterisable damper actuator in the

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data. Safety notes. Power consumption In operation At rest For wire sizing

11 VA Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque (nominal torque) Motor Spring return

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

Technical data sheet. Technical data. Safety notes

Technical data. T2-SM230ASR en v Subject to changes / 3. Electrical data Nominal voltage AC

Overview of types. Technical data

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A)

AC/DC 24 V, 50/60 Hz. Functional data Variable Settings. DC V, max. 0.5 ma. End point DC V... 4 ma ma Non-variable

Power consumption In operation At rest For wire sizing

Technical data. Safety notes

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation Vmax low-n: Vmax for low-noise operation

Power consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O

Power consumption In operation At rest For wire sizing

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Brief description. VAV-Compact MP en-gb Changes reserved 1. Application. Pressure measurement. Actuator

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Installation of VAV-Compact Retrofit with ZDMS-..

Overview of types. Technical data. T5-NRDVX24-SR-T-.. en v Subject to changes 1 / 3

Technical data. Safety notes. T5-HT24-SR-T en v Subject to changes 1 / 3

Image. Installation VAV-Universal Retrofit-Set. General Information. Safety notes

VAV solutions for comfort applications

Type overview. Technical data

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Power consumption Operation At rest Wire sizing

Adaptive control system for duct and room pressure applications. Table of Contents

Rp [ ] [ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

VAV-Compact. Contents. Modbus General Notes 2 Modbus Register Overview 3 Modbus Register Description 4

..-MF /..-MP /..-MFT(2) /..-MOD /..LON..-MF /..-MP /..-MFT(2) /..-MOD /..LON

DN [ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Air Water Actuators xm(c)24a-mod xr24a-mod xv(k)24a-mod xf24a-mod xrf24a-mod

Specification GRUNER YSP 227C

1. Function. Universal dimming actuator REG-K/2x230/ 300 W. Universal dimming actuator REG-K/230/ 500 W. Universal dimming actuator REG-K/230/ 1000 W

kvs theor.: Theoretical kvs value for pressure drop calculation Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Introduction to MP-Bus Technology

VAV solution for controlled apartment ventilations

kvs theor.: Theoretical kvs value for pressure drop calculation Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical manual GS 4x.00 knx application description air quality sensor

Air damper actuators. OpenAir GDB..1E. Electronic motor driven actuators for open-close, three-position and modulating control

Configured air damper actuators 6FU11xx-xDxxx-xxxx

Air damper actuators. OpenAir GSD...1A. Electric motor-driven rotary actuators for open-close, three-position and modulating control

NRT 105: Electronic fan-coil controller, equiflex

Rotary actuators for ball valves

Belimo Gateway MP to BACnet MS/TP - UK24BAC

PRODUCT MANUAL. ABB i-bus KNX VC/S 4.x.1 Valve Drive Controller

CR24-.. Single room controllers

7.2 DV1311.L08 and DV1311.L12

Brief description. VAV-Compact LON en-gb Changes reserved 1. Application. Pressure measurement

KNX Room temperature controller

Room Temperature Controllers. for heating and cooling systems

Rotary actuators for ball valves

GM24-MFT US. Proportional damper actuator, non-spring return, Multi-Function Technology

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Room Temperature Controllers. for heating and cooling systems

Intelligent Installation Systems. ABB i-bus KNX Room Thermostat Fan Coil with Display 6138/11-xx-500 Product Manual

AC 01.2 HART Technical data Actuator controls

TA-Slider 160 KNX Protocol Implementation

Volumetric flow controller

Thorsten Reibel, Training & Qualification Global Application and Solution Team

AC 01.2 Modbus TCP/IP

Extension for ground plate Z-SMA. Shaft extension AV8-25. Reversible spindle clamp K-SA. Damper crank arm KH8. Extension from SM.. or AM.. to SM..A..

Fan Coil Actuator FCA 2

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Rotary actuators for ball valves

Instruction manual. art Installation manual

Spring Return DuraDrive Proportional Actuator

Product Manual. ABB i-bus EIB / KNX. Universal Interface US/U Intelligent Installation Systems

Use of the application program. Contents. instabus EIB Application program description. September S2 Room temperature controller

Room Temperature Controllers. for heating and cooling systems

VP60. 5/3 Way proportional directional control valves Nominal diameter 8 direct operated sliding valves with µp-driven position control

EY-EM 527: Remote I/O module, ecolink527

The universal input/output device is a DIN rail mounted device. It is connected to the EIB via a bus connecting terminal.

Rotary actuators for ball valves

Wireless Room Thermostat Installation and Operation Y6630D1007

02/11/2015

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

02/11/2015

ABB i-bus KNX Valve Drive Actuator VAA/S x Product Manual

ASV115CF132: Standard VAV compact controller

Transcription:

echnical data sheet VAV-Compact KNX A pressure sensor, digital VAV controller and damper actuator all in one, providing a VAV-Compact solution with a communications capability for pressureindependent VAV systems in the comfort zone Control function: VAV Communication via KNX (S-Mode) Conversion of sensor signals Diagnostic socket for operating devices LMV-D3-KNX NMV-D3-KNX Brief description Application Mode of operation Converter for sensors Adjustable-parameter actuators Pressure measurement Actuator VAV variable volumetric flow Operating and service devices Assembly and connection OEM factory settings he digital VAV-Compact has PI control characteristics and is used for pressure-independent control of VAV units in the comfort zone. he VAV-Compact is equipped with an integrated interface for KNX (S-Mode). he VAV controller can be connected with all KNX devices that have corresponding data points available. Connection option for a sensor (active sensor or switching contact). In this way, the analogue sensor signal can be easily digitised and passed along to KNX. he factory settings cover the most common applications. As desired, individual parameters can be adapted for specific systems or servicing with a service tool (e.g. ZH EU) or the ES planning and commissioning tool. Maintenance-free dynamic pressure valve sensor, tested in versatile applications, enables use ranging from office, hospital room mountain hotel to cruise ship. wo versions are available, depending on the size of the VAV unit: 5 or 10 Nm. he VAV-Compact is supplied with its modulating setpoint by a room temperature controller via KNX. his facilitates demand-related, power-saving ventilation in individual rooms or zones of air conditioning systems. he operating range ( min and max ) can be set with the PC-ool, the ZH EU (locally) or via KNX. Belimo PC-ool or service tool ZH EU, pluggable on the VAV-Compact. he VAV-Compact device, which is assembled on the unit by the OEM, is connected using the prefabricated connecting cable. he VAV-Compact is mounted on the VAV unit by the unit manufacturer, who adjusts and tests it according to the application. he VAV-Compact is sold exclusively via the OEM channel for this reason. ype overview ype orque Power consumption For wire sizing Weight LMV-D3-KNX 5 Nm 2 W 4 VA (max. 5 A @ 5 ms) Approx. 500 g NMV-D3-KNX 10 Nm 3 W 5 VA (max. 5 A @ 5 ms) Approx. 700 g www.belimo.com VAV-Compact KNX en-gb 2015-02-20 Subject to changes 1 / 8

echnical Data Supply Nominal voltage Operating range Differential pressure sensor Overload capability Installation position Fluid medium Materials in contact with medium Measuring air conditions Application Operating volumetric flow nom max min Data for KNX Medium Number of nodes Operating mode Voltage consumption of KNX-Bus Planning and commissioning tool Operation and servicing Push-button LED display AC 24V, 50/60 Hz / DC 24V AC 19.2...28.8 V / DC 21.6...28.8 V 0...600 Pa ±3000 Pa Any, no reset necessary Supply and exhaust air in the comfort zone and in applications with sensor-compatible media Glass, epoxy resin, PA, PE 0... +50 C / 5... 95% rh, non-condensing SUP/EXH units VAV, integrated in KNX networks OEM-specific nominal volumetric flow setting, suitable for the VAV unit 20...100% of nom 0...100% of nom KNX P max. 64 per line segment, reduce number of nodes with connection cable with short lines S-Mode max. 5 ma ES4 or higher Pluggable / PC-ool (V3.9 or higher) Adaptation / programming 24V supply Status Actuator Brushless, non-blocking actuator with power-save mode Direction of rotation ccw / cw Angle of rotation 95, adjustable mechanical or electronic limiting Adaptation Capture of setting range and resolution to control range Gear disengagement Push-button self-resetting without functional impairment Position Indication Mechanical with pointer Sound power level max. 35 db(a) @ 90 s Spindle holder Spindle clamp, axis round 10... 20 mm / axis square 8... 16 mm Form fit in various versions, e.g. 8 x 8 mm Connection Cable, 6 x 0.75 mm 2 Safety Protection class III Safety extra-low voltage Degree of protection IP54 EMC CE according to 2004/108/EU Mode of operation ype 1 (as per EN 60730-1) Rated impulse voltage 0.5 kv (acc. to EN 60730-1) Control pollution degree 2 (in acc. with EN 60730-1) Ambient temperature 0...+50 C Non-operating temperature 20...+80 C Ambient humidity range 5... 95% rh, non-condensing (in accordance with EN 60730-1) Maintenance Maintenance-free Safety notes! he device must not be used outside the specified field of application, especially not in aircraft or in any other airborne means of transport. It may only be installed by suitably trained personnel. Legal regulations and regulations issued by authorities must be observed during installation. he device may only be opened at the manufacturer's site. It does not contain any parts that can be replaced or repaired by the user. he cable must not be removed from the device. When calculating the torque required, the specifications supplied by the damper manufacturers (cross-section, construction, place of installation), and the ventilation conditions must be observed. he device contains electrical and electronic components and is not allowed to be disposed of as household refuse. All locally valid regulations and requirements must be observed. 2 / 8 VAV-Compact KNX en-gb 2015-02-20 Subject to changes www.belimo.com

KNX Group Objects Name ype Flags Data point type Values range C R W U ID DP_Name Format Unit Setpoint I C W 5.001 _Scaling 1 Byte % [0...100] Override control I C W 20.* _Enum 1 Byte 0 = no override 1 = Open 2 = Closed 3 = Min 4 = Mid 5 = Max Reset I C W 1.015 _Reset 1 Bit 0 = no action 1 = reset Adaptation I C W 1.017 _rigger 1 Bit 0 = no action 1 = adapt estrun I C W 1.017 _rigger 1 Bit 0 = no action 1 = estrun Min I/O C R W 5.001 _Scaling 1 Byte % [0...100] Max I/O C R W 5.001 _Scaling 1 Byte % [0...100] Relative position O C R 5.001 _Scaling 1 Byte % [0...100] Absolute position O C R 8.011 7.011 _Rotation_Angle _Length_mm 2 Byte mm [32,768...32,768] [0...65,535] Relative volumetric flow O C R 5.001 _Scaling 1 Byte % [0...100] Absolute volumetric flow O C R 14.077 _Value_Volume_Flux 1 Byte m 3 /s Resolution: 1 m 3 /s Nominal volumetric flow O C R 14.077 _Value_Volume_Flux 4 Byte m 3 /s Resolution: 1 m 3 /s Fault state O C R 1.002 _Bool 1 Bit 0 = no fault 1 = fault Overridden O C R 1.002 _Bool 1 Bit 0 = not active 1 = active Gear disengaged O C R 1.002 _Bool 1 Bit 0 = engaged 1 = disengaged Service information O C R 22.* _Bitset16 2 Byte Bit 0 (1) Bit 1 (2) Bit 2 (4) Bit 3 (8) Sensor value Relative humidity Air quality Voltage mv Voltage scaled Voltage scaled % Switch O C R 9.007 9.008 9.020 7.* 5.001 1.001 _Value_Humidity _Value_AirQuality _Value_Voltage _Scaling _Switch 2 Byte 2 Byte 2 Byte 2 Byte 1 Byte % rh ppm mv % Bit 4 (16) Bit 5 (32) Bit 6 (64) Bit 7 (128) Bit 8 (256) Bit 9 (512) [0...670,760] [0...670,760] Excessive utilisation Mechanical travel increased Mechanical overload (Not used) (Not used) (Not used) (Not used) (Not used) [670,760...670,760] [0...65,535] [0...100] 0/1 Internal activity Bus watchdog triggered www.belimo.com VAV-Compact KNX en-gb 2015-02-20 Subject to changes 3 / 8

KNX Group Objects (Continued) Setpoint Override control Reset Adaptation estrun Min Max Specification of set volume or actuator position in % between the parameterised Min and Max limits. he operating mode is set by the manufacturer of the volumetric flow unit. Overriding the setpoint with defined override states. As data point type, 1 Byte (unsigned) is recommended (DP 20.*) Resetting the stored service messages (see KNX group object Service information). Perform the adaptation. he first-time adaptation is performed by the manufacturer of the volumetric flow unit. An active adaptation is signaled in Bit 8 of Service information. Performance of a testrun that checks the entire operating range. An active testrun is signaled in Bit 8 of Service information. After completion, detected faults (mechanical overload, mechanical travel increased) are signaled in Service Information. Minimum Limit (volumetric flow or position) in % of the nominal volumetric flow V nom Caution: Changing the setting may result in malfunctions. Maximum Limit (volumetric flow or position) in % of the nominal volumetric flow V nom Caution: Changing the setting may result in malfunctions. Relative position Current actuator position in % Absolute position Relative volumetric flow Absolute position/stroke he data point type is to be selected depending on the type of movement: [ ] DP 8.011 [mm] DP 7.011 Relative volumetric flow in % of the nominal volumetric flow V nom Absolute volumetric flow Absolute volumetric flow in m 3 /s Nominal volumetric flow Nominal volumetric flow in m 3 /s he nominal volumetric flow is determined by the manufacturer of the volumetric flow unit. Fault state Overridden Gear disengaged Service information Sensor value Collective fault based on Bit 0 Bit 7 of Service information Signaling of an active override control (OPEN/CLOSED) he device can be commanded via the KNX group object Override control or via the forced switching at the input Y/3. Only the override controls OPEN and CLOSED are signaled. Signaling an active gear disengagement Detailed information regarding device status As data point type, Bitset 16-Bit is recommended (DP 22.*) Status information Bit 0: Motor operation in relation to operating period too high Bit 1: Mechanical travel increased, e.g. defined end position exceeded Bit 2: Mechanical overload, i.e. defined end position not reached Bit 3 7: not used with this device type Bit 8: Internal activity (Synchronisation, Adaptation, estrun, ) Bit 9: Bus watchdog triggered Bit 0 Bit 7 are stored by the device and can be reset with the KNX group object Reset. As an alternative, they can be read as collective fault state. he representation of the sensor value is dependent on the parameterization. See section "KNX parameters Sensor" 4 / 8 VAV-Compact KNX en-gb 2015-02-20 Subject to changes www.belimo.com

KNX parameters Common Altitude [m] he specification of the system altitude increases the precision of the volumetric flow control. Values range: 0 3000 m Factory setting: 500 m Setpoint at bus failure Bus timeout [min] Increment for value update [%] Repetition time [s] A setpoint can be defined for cases of communication interruption. Values range: Factory setting: None (last setpoint) Open Closed Mid None (last setpoint) he monitoring of the communication takes place for the KNX group objects Setpoint and Override control. If none of the objects is written within the parameterised monitoring time, the bus fail position is set and signaled in the Service information (Bit 9). Monitoring time for the detection of a communication interruption. Values range: 1 120 min Factory setting: Actual values (position, volumetric flow) are transferred at the time of a value change insofar as these change by the parameterised difference value. If the relative value changes by the difference value, not only the relative actual value but also the absolute actual value are transferred. Values range: 0 100% Factory setting: 5% he transfer is deactivated with 0% in the event of a value change. Repetition time for all position, volume and sensor actual values. Status objects are not transferred except with a change. Values range: Factory setting: 0 3600 s 0 = no periodic transmission KNX parameters Sensor Sensor type he input Y/3 can be used to connect a sensor. he sensor value is digitised and made available as KNX communication object. Values range: Factory setting: No sensor Active sensor (0 32 V) Switch (0 / 1) Humidity sensor (0-10 V corresponds to 0 100%) Air quality sensor CO2 (0-10 V corresponds to 0 2000 ppm) No sensor A switching to Y/3 is treated as local override in the absence of sensor parameterization. Increment for sensor value update Output (for sensor type "Active sensor") Polarity (for sensor type "Switch") he sensor value is transferred at the time of a value change insofar as this changes by the parameterised difference value. Values range: 0 65,535 Factory setting: 1 he transfer is deactivated with 0 in the event of a value change. Without value change, the sensor value is sent because of the repetition time. Only for "Active sensor" sensor type Values range: Sensor value mv (DP 9.020) Sensor value scaled (DP 7.xxx) Sensor value scaled % (DP 5.001) Factory setting: For "Sensor value mv", the measured voltage is made available without processing. In the case of the scaled sensor values, a linear transformation can be defined with two points. he polarity can be defined for the sensor type "Switch". Values range: Normal Inverted Factory setting: www.belimo.com VAV-Compact KNX en-gb 2015-02-20 Subject to changes 5 / 8

Work procedures Product database he product database for the import in ES4 or higher is available at the Belimo website www.belimo.eu (Download Center) Setting physical address Firmware upgrade Resetting to KNX factory settings he programming of the physical address takes place by ES and the programming button on the device. If the programming button is not accessible or accessible only with difficulty, then the address can be set using a point-to-point connection: "Overwrite Individual Address: 15.15.255" As a third possibility, the physical address can be programmed on the basis of the KNX series number (e.g. with Moov n Group). he KNX series number is placed on the device in two versions. One sticker can be removed for adhesion on the commissioning journal, for example. he KNX firmware of the device is updated automatically with the programming of the application program insofar as the product database has a more recent version. he first programming procedure takes somewhat longer in such cases (>1 min). If necessary, the device can be reset manually to the KNX factory settings (physical address, group address, KNX parameters). For the reset, the programming button on the device must be pressed down for at least 5 s during start-up. ool connection Settings and diagnostics he settings and diagnostics of the connected VAV-Compact controller can be checked and adjusted easily and rapidly with the Belimo PC-ool or with the ZH EU service tool. On-board service connection he service connection integrated in the VAV-Compact enables a rapid connection of the operating device used. + AC 24 V DC 24 V 1 2 3 5 6 7 MP USB i esc OK BELIMO PC-ool USB + MF D+ D 6 / 8 VAV-Compact KNX en-gb 2015-02-20 Subject to changes www.belimo.com

Electrical installation Wiring diagrams Note Connection via safety isolating transformer.! Connection without sensor + KNX Note Signal assignment KNX: D+ = KNX+ (pink red) D = KNX (grey black) he connection to the KNX line should take place via WAGO connecting clamp 222/221. 1 2 3 5 6 7 MF D + D Connection with switching contact, e.g. p-monitor + KNX p Requirements for switching contact: he switching contact must be able to accurately switch a current of 16 ma at 24 V. 1 2 3 5 6 7 MF D + D Connection with active sensor, e.g. 0... 10V @ 0... 50 C + KNX Possible input voltage range: 0...32 V (resolution 30 mv) 1 2 3 5 6 7 MF D + D VAV controller with local override control (analogue override) + KNX Note If no sensor is integrated, then connection 3 (Y) is available for the protective circuit of a local override control. Options: CLOSED, max, OPEN Note: Functions only with AC 24V supply. OPEN max CLOSED Bus mode 1 2 3 5 6 7 MF D + D www.belimo.com VAV-Compact KNX en-gb 2015-02-20 Subject to changes 7 / 8

Operating controls and indicators 1 Push-button and LED display green Off: On: Press button: No power supply or fault Operation riggering the angle of rotation adaptation 3 Adaption 1 Power 2 Status 2 Push-button and LED display yellow Off: On: Flashing: Press button: he actuator is ready Adaptation or synchronising process active or actuator in programming mode (KNX) Connection test (KNX) active in operation (>1 s): Switch the programming mode On and Off (KNX) when starting (>5 s): Reset to factory setting (KNX) 4 3 Gear disengagement button Press button: Release button: Gear disengaged, motor stops, manual override possible Gear engaged, synchronisation starts, followed by standard operation 4 Service plug For connecting parameterising and service tools Dimensions [mm] Dimensional drawings LMV-D3-KNX 116 66 61 22 116 41 Dimensional drawings NMV-D3-KNX 124 80 62 25 121 41 8 / 8 VAV-Compact KNX en-gb 2015-02-20 Subject to changes www.belimo.com