Goyen 2000 Flue Gas Analyzer Two Sensors (O 2, CO) CO Sensor (0-8000 ppm) 300mm Probe (800 o C max) with 3m Dual Hose, longer & high temp. probes optional External Water Trap with Filter Cartridge Rechargeable battery pack with 110VAC charger plug, other voltages/plugs Internal Memory (250 tests) Built-In Printer with Non-Thermal Paper PC Software Package for Data Storage and Configuration Protective Rubber Holster with Magnetic Support Hard Plastic ABS Carrying Case Spare Consumable Parts (5 Filter Cartridges, 5 Paper Rolls, 1 Printer Ribbon)
Goyen 4000 Kit #1 Flue Gas Analyzer Three Sensors (O 2, CO, NO/NOx) CO Sensor (0-8000 ppm) with dilution pump for autoranging to 100,000 ppm, Low CO optional 300mm Probe (800 o C max) with 3m Dual Hose, longer & high temp. probes optional External Water Trap with Filter Cartridge Rechargeable battery pack with 110VAC charger plug, other voltages/plugs Internal Memory (250 tests) Built-In Printer with Non-Thermal Paper PC Software Package for Data Storage and Configuration Protective Rubber Holster with Magnetic Support Hard Plastic ABS Carrying Case Spare Consumable Parts (5 Filter Cartridges, 5 Paper Rolls, 1 Printer Ribbon)
Goyen 4000 Kit #2 Flue Gas Analyzer Four Sensors (O 2, CO, NO/NOx, NO 2 or SO 2 ) CO Sensor (0-8000 ppm) with dilution pump for autoranging to 100,000 ppm, Low CO optional NO 2 Sensor (0-1000 ppm) or SO 2 Sensor (0-4000 ppm) 300mm Probe (800 o C max) with 3m Dual Hose, longer & high temp. probes optional External Water Trap with Filter Cartridge Rechargeable battery pack with 110VAC charger plug, other voltages/plugs Internal Memory (250 tests) Built-In Printer with Non-Thermal Paper PC Software Package for Data Storage and Configuration Protective Rubber Holster with Magnetic Support Hard Plastic ABS Carrying Case Spare Consumable Parts (5 Filter Cartridges, 5 Paper Rolls, 1 Printer Ribbon)
Goyen 6000 Kit #1 Flue Gas Analyzer Five Sensors (O 2, CO, NO, NO 2, SO 2 ) CO Sensor (0-8000 ppm) with dilution pump for auto-ranging to 100,000 ppm, Low CO optional NO 2 Sensor (0-1000 ppm), Low NO 2 optional SO 2 Sensor (0-4000 ppm) 300mm Probe (800 o C max) with 3m Dual Hose, longer & high temp. probes optional Built-In Cooler with Automatic Condensate Removal Internal Memory (1000 tests) Remote Control Unit includes Built-In Printer with Non-Thermal Paper Spare Consumable Parts (5 Line Filters, 5 Water Condenser Filters, 2 Interference Filters, 5 Paper Rolls, 1 Printer Ribbon)
Goyen 6000 Kit #2 Flue Gas Analyzer Six Sensors (O 2, CO, NO, NO 2, SO 2, H 2 S or CxHy) CO Sensor (0-8000 ppm) with dilution pump for auto-ranging to 100,000 ppm, Low CO optional NO 2 Sensor (0-1000 ppm), Low NO 2 optional SO 2 Sensor (0-4000 ppm) H 2 S Sensor (0-1000 ppm) or CxHy Sensor (0-5%) 300mm Probe (800 o C max) with 3m Dual Hose, longer & high temp. probes optional Built-In Cooler with Automatic Condensate Removal Internal Memory (1000 tests) Remote Control Unit includes Built-In Printer with Non-Thermal Paper Spare Consumable Parts (5 Line Filters, 5 Water Condenser Filters, 2 Interference Filters, 5 Paper Rolls, 1 Printer Ribbon)
Goyen 8000 Wireless Kit #1 Flue Gas Analyzer Five Sensors (O 2, Low CO, Low NO, Low NO 2, SO 2 ) Low CO Sensor (0-500 ppm with 0.1 ppm resolution) Low NO Sensor (0-500 ppm with 0.1 ppm resolution) Low NO 2 Sensor (0-500 ppm with 0.1 ppm resolution) SO 2 Sensor (0-4000 ppm) Upgradeable to optional additional H 2 S, CO 2, and CxHy Sensors 300mm Probe (800 o C max) with 3m Dual Hose, longer & high temp. probes optional Heated Line optional Built-In Peltier Chiller with Automatic Condensate Removal Internal Memory (9000 tests) Remote Control Unit with Bluetooth Wireless Communications includes Built-In Printer with Non-Thermal Paper Spare Consumable Parts (5 Line Filters, 2 Interference Filters, 5 Paper Rolls, 1 Printer Ribbon)
Goyen 8000 Wireless Kit #2 Flue Gas Analyzer Eight Sensors (O 2, CO, NO, NO 2, SO 2, H 2 S, CO 2, CxHy) CO Sensor (0-8000 ppm) with dilution pump for auto-ranging to 100,000 ppm, Low CO optional NO 2 Sensor (0-1000 ppm), Low NO 2 optional SO 2 Sensor (0-4000 ppm) H 2 S Sensor (0-1000 ppm) CO 2 Sensor NDIR (0-40%) CxHy Sensor NDIR (0-50,000 ppm) 300mm Probe (800 o C max) with 3m Dual Hose, longer & high temp. probes optional Heated Line optional Built-In Peltier Chiller with Automatic Condensate Removal Internal Memory (9000 tests) Remote Control Unit with Bluetooth Wireless Communications includes Built-In Printer with Non-Thermal Paper Spare Consumable Parts (5 Line Filters, 2 Interference Filters, 5 Paper Rolls, 1 Printer Ribbon)
Goyen 8000LBH Wireless Flue Gas Analyzer & True Mass Emissions Monitor Four Sensors (O 2, CO, NO, NO 2 ) CO Sensor (0-8000 ppm) with dilution pump for auto-ranging to 100,000 ppm, Low CO optional NO 2 Sensor (0-1000 ppm), Low NO 2 optional Upgradeable to nine total sensors Special 750mm Probe (800 o C max) with 3m Dual Hose combined with Pitot Tube to allow for simultaneous measurement of gas concentrations, temperature, and velocity Calculates Mass Emissions (kg/hr or lbs/hr) for gases measured Heated Line optional Built-In Peltier Chiller with Automatic Condensate Removal Internal Memory (9000 tests) Remote Control Unit with Bluetooth Wireless Communications includes Built-In Printer with Non-Thermal Paper Spare Consumable Parts (5 Line Filters, 2 Interference Filters, 5 Paper Rolls, 1 Printer Ribbon)
Heated Line for Goyen 8000 The heated line includes the following: Heated Probe Handle with Pneumatic Connector 750mm Probe Tip, 800 o C max, with Thermocouple Heated Hose, 2m long Other lengths of probe tips and heated hose are Spare Consumable Parts (5 Heated Probe Filters) Compatible with Goyen 8000 Gas Analyzers Replaces 300mm non-heated probe shown in Goyen 8000 Kits Heated Line for Goyen 8000LBH The heated line includes the following: Heated Probe Handle with Pneumatic Connector Compatible with Goyen 8000LBH Special 750mm probe tip Heated Hose, 2m long Other lengths of heated hose are Spare Consumable Parts (5 Heated Probe Filters) Compatible with Goyen 8000LBH Gas Analyzers