Carbon Dioxide Sensor for the LogIT Microsense system
|
|
- Lynne Boone
- 5 years ago
- Views:
Transcription
1 Carbon Dioxide Sensor for the LogIT Microsense system Overview The Carbon Dioxide sensor is designed to measure the amount of Carbon Dioxide gas present in air. It provides measurements in Parts Per Million (ppm). It uses NDIR (Non Dispersive Infrared Absorbance) to measure the CO 2 molecules present in the air. Ideas for use Environmental monitoring of CO 2 levels. Greenhouse CO 2 monitoring. Plant growth and measurements of optimum growing conditions. Photosynthesis studies. Human breath composition. Office/Classroom/Home environmental studying. Specifications Standard Range: ppm (resolution 1 ppm) Alternative Range (via software): ppm (resolution 1 ppm) Accuracy at 22 O C ppm range: +/- 40ppm + 3% of reading Temperature dependence: 0.2% FS per O C Stability: < 2% of FS over sensor life (>5 years typical) Pressure Dependence: of reading per mm Hg Data reading: Every 2 seconds (depending on logging mode) Operating Conditions: 0 O C to 50 O C (32 O F to 122 O F) 0 to 95% RH, non condensing Storage conditions: -40 O C to 70 O C (-40 O F to 158 O F) External power connector: 2.1 mm DC plug centre negative. External power required: 9V DC 45mA Average, 150mA Max Battery requirement: 2 x Alkaline or rechargeable AA type Care This sensor is not waterproof. Do not use the sensor in excessive damp conditions or extremes of temperature as permanent damage will result. Do not disassemble this sensor, no user serviceable parts inside. Trouble shooting If the sensor reads 13 ppm continuously your batteries need to be replaced or the external power supply needs checking This is a very new sensor and your software and/or LogIT with display may need updating to support it, which is usually available over the internet free of charge. If the sensor is not recognised by your software or LogIT (for example if the datalogger displays???) you probably need a software update. LogIT Lab will also update the LogIT datalogger - if you are using different data logging software you can download an evaluation version of LogIT Lab to update your LogIT(s): Instructions & Resources 1: Visit the LogIT website 2: To upgrade your datalogging software click on the Downloads tab followed by Software Updates. The installation instructions are available from the same page. 3: To upgrade the datalogger, select the logger from the list on the left of the page followed by the Support tab and then select Logger Updates. Follow the on screen instructions. Note: Sensorlink, LogIT SL and LIVE will not need to be upgraded, only the datalogging software they are used with. Note the Carbon Dioxide sensor is not compatible with the CheckIT display for LogIT SL/LIVE. Basic recalibration can be done by the user on sensors manufactured after July see Recalibration on instructions page. The resources shown overleaf are available in PDF form at
2 Carbon Dioxide Sensor for the LogIT Microsense system Instructions & Resources In Use The LogIT CO 2 sensor uses NDIR (Non Dispersive Infrared Absorbance) technology which is generally considered superior in life and performance to electrochemical type measuring. The infrared source takes a considerable amount of power and so in order to enable optimum portable battery operation the sensor incorporates intelligent power management to both conserve power and optimise perfomance. This power management is automatically controlled by the sensor s own microprocessor and will balance data capture with battery conservation to produce accurate and reliable data making best use of battery life. This allows long term portable datalogging in remote places such as greenhouses or environmental monitoring. Preparing for use When first plugged into a LogIT Datalogger the sensor should ideally be left for 10 minutes for the internal sensor to stabilise and give the most accurate readings, although usable readings can be obtained after 2 minutes. Powering the CO 2 sensor from an external power pack If you are using the sensor in a lab or where a mains supply is readily available then it will probably be most convenient to power it from a mains power adapter. The sensor requires 9 volts dc at an average of 45mA with peak at 150mA so that the standard LogIT power pack or many other DC power units may be used (The connector required is a 2.1mm diameter DC power plug with centre pin negative polarity). When powered from an external power pack the sensor reading is updated every 2 seconds and LogIT will always display & record the last reading it receives from the sensor. Powering the CO 2 sensor from internal batteries If you wish to use the sensor in a remote or portable environment you will probably find it appropriate to power it from internal batteries. Fit 2 AA Alkaline or fully charged AA Rechargeable cells into the battery compartment. When powered by batteries internal software uses the following sensor update rates to conserve power (these do not apply when being powered by a mains power pack): Autolog Logging: When the sensor detects the datalogger is in Autolog mode the CO 2 sensor takes readings every 2 seconds for the first two hours and therefter changes to only taking a fresh measurement every 30 minutes to conserve battery life. Note that LogIT will always display and record the last reading taken so that this power saving mode does not interfere with logging and graphs, but you should be aware that after 2 hours it is only taking a fresh reading every 30 minutes. For more frequent logging on battery power use Set Log rate as below. Set Log rate When the CO 2 sensor detects that the datalogger has been set up to a specific log rate, it only powers on and takes a reading when required. Low Battery warning If you see 13 PPM continuously on the datalogger display this indicates that the internal batteries of this sensor need replacing or that an external power adapter plugged into the sensor is not working correctly). Recalibration Your CO2 sensor is supplied precalibrated but accuracy can change over time. On units manufactured after July 2009 you can perform basic recalibration yourself outdoors (which is typically 400ppm). You will need your CO2 sensor with batteries or power pack, a straightened paper clip and a LogIT with built-in display or a computer connected - note this recalibration MUST be done outside where there is ample flow of fresh air. Turn on your logger and plug in the CO2 sensor. While the display counts down from 3 to 1 GENTLY push a paper clip into the small hole on the side of the case. The display should change from displaying PPM to DATA and the value on the screen will now count down from 999 to 0 which will take just over 16 minutes as the sensor warms up, after which automatic calibration will commence and will take about 1 minute. When calibration is over the display should show the CO2 level - if you breath over the grille you will see the readings change. To complete calibration and return the sensor to normal mode displaying PPM, just unplug it from the LogIT and it is ready to use.
3 Photosynthesis and the Plant Subject: Biology Sensor: Carbon Dioxide sensor, Temperature sensor, Light sensor Overview: By mounting the Carbon Dioxide sensor within a small Biosphere a plants ability to absorb CO 2 can be monitored over a short space of time along with the temperature and light indicating the effects these parameters have on the CO 2 levels. Equipment required: LogIT Carbon Dioxide sensor LogIT temperature sensor (ProTemp or HiTemp) LogIT light sensor (LUX, Smarteye or SPX LUX) LogIT Datalogger Sensor extension leads Plastic bag or propagator and some elastic bands Plant Hazards: Place the apparatus in such a way that it will not come into contact with water or be exposed to excessive moisture. Always check your local regulations or the school advisory service such as CLEAPSS or SSERC for guidance on the use of any hazardous material. Suggested Method 1. Attach the CO 2 sensor to the side of the plant pot using an elastic band or similar. ( If using a small propagator as shown in the photo, place the sensor in the bottom) 2. Place the temperature sensor and light sensor in a similar way to the CO 2 sensor. 3. Connect the sensors to the datalogger. 4. Switch on the logger and allow the sensor to stabilise for 10 minutes. 5. Place the whole plant and sensors into a plastic bag sealing the end with another elastic band. 6. Start logging the CO 2 using the logger remotely or connected to a computer. Results: Note: Do not place in direct sunlight as this can kill the plant in such a small propagator. Biology Do the results show that Photosynthesis has taken place? What happens to the concentration of CO 2 when the light increases/decreases? Is this a surprise? Why does this happen? What happens to the temperature? Why does this happen? Going further: Try and get some data from a greenhouse or similar plant propagation. How might you set up an experiment to see how CO 2 levels effect plant growth?
4 The classroom Subject: Biology Sensor: Carbon Dioxide sensor. Overview: By placing the CO 2 sensor in a classroom, the levels of CO 2 can be recorded along with the effects of opening and closing windows and doors. Equipment required: LogIT Carbon Dioxide sensor LogIT datalogger Hazards: Place the apparatus in such a way that it will not come into contact with water or be exposed to excessive moisture. Always check your local regulations or the school advisory service such as CLEAPSS or SSERC for guidance on the use of any hazardous material. Suggested Method 1. Position the CO 2 sensor on a suitable table. 2. Connect the sensor to the LogIT Datalogger. 3. Switch on the logger and allow the sensor to stabilise for 10 minutes. 4. Start logging the CO After a predetermined time eg. near the end of the lesson, stop logging. Results: Note: This procedure can be run for the length of a lesson or during an entire day. It is also good logging practise to add markers when an event occurs such as a window being opened or a door left ajar. You may also like to perform the experiment connected to a computer and the results discussed during the lesson as changes take place. What do the results show? Can you see a pattern? How does opening a window affect the readings? Environment Going further: What other rooms might you consider monitoring? Monitor a sports hall during a sports event. How might the level of CO 2 effect the performance of the players?
5 Human breath Subject: Biology Sensor: Carbon Dioxide sensor Overview: By breathing into a bag, the amount of CO 2 can be recorded before and after exercise to see if more or less CO 2 is expelled. Equipment required: LogIT Carbon Dioxide Sensor (Use software to select ppm range) LogIT datalogger Large plastic bag or similar. Hazards: Ensure any exercise is suitable for the student and the surrounding environment. Always check your local regulations or the school advisory service such as CLEAPSS or SSERC for guidance on the use of any hazardous material. Suggested Method 1. Place the CO 2 sensor into a large plastic bag. 2. Plug the sensor into a LogIT datalogger and connect to a computer (change scale to ppm) 3. Switch on the logger and allow the sensor to stabilise for 10 minutes. 4. Breathe into the bag and allow the value to peak. Record the value. 5. Perform some exercise. 6. Again, breathe into the bag and note the peak value. Note: It is important that when breathing into the bag the breath is not forced out as over range and false readings can be taken. It might be better to simply breathe normally and then placed the bag over the mouth at a suitable out breath. A large bin liner was found to produce good results. You can overlay the two sets of results. Results: Biology What do the results show? Does this confirm your prediction as to what might happen? Why is there a change in the amount of CO 2? What does this suggest is happening in the body during exercise? Going further: Try monitoring different forms of exercise. Does this make a difference to the CO 2 levels? What other sensors might be used in conjunction with the CO 2 to show how the body works during exercise? An example might be a temperature sensor or Heart receiver.
6 Pollution - Road side monitoring Subject: Environmental Sensor: Carbon Dioxide sensor Overview: By mounting the Carbon Dioxide sensor by the side of a road, the CO 2 levels emitted by passing traffic can be directly compared with other roads in different locations. Equipment required: LogIT Carbon Dioxide sensor LogIT datalogger Elastic band Hazards: Students should be supervised at all times when used near roads or by traffic. Do not cause a distraction to any road users. Place the apparatus in such a way that it will not come into contact with water or be exposed to excessive moisture. Always check your local regulations or the school advisory service such as CLEAPSS or SSERC for guidance on the use of any hazardous material. Suggested Method Results: 1. Attach the CO 2 sensor to the logger using the elastic band as shown. (The photo shows a LogIT Voyager datalogger being used). 2. Connect the sensor to the LogIT Datalogger. 3. Switch on the logger and allow the sensor to stabilise for 10 minutes. 4. Start logging the CO After a predetermined time stop logging. Note: For this example, the logger and sensor were held in the hand and was then walked around the town. This enabled a good mix of data from the main street in a small market town. Of course you can also obtain data by staying in one location. What happens to the CO 2 levels? Where is this CO 2 coming from? How might buildings affect the readings? Environment Going further: How might different times of day change the results? How might the height of the sensor effect the results ie. what would the levels of Carbon Dioxide be at the height of an office window?
7 Ideas for other experiments Car journey. By simply monitoring the CO 2 levels in car during a journey, the effects of opening and closing windows or the sun roof can be observed. The results can change quite dramatically. You may like to discuss how stuffy cars can bring on tiredness. Note: In no way should you ever artificially alter the CO 2 levels by sealing vents or other ventilation systems fitted to a car. These are fitted for the very purpose of preventing build up of fumes. The results shown below are from a typical journey from home to work with windows being opened at various times. (The peaks occur just after a window was opened and the troughs just after the window was closed) Journey through a town and country. Try mounting the sensor and logger onto a bike and cycle through a town. Then cycle through the countryside. Any difference in the data obtained?
8 DCP Microdevelopments Ltd Bryon Court Bow Street Great Ellingham Norfolk NR17 1JB Tel: Fax: Waste electrical and electronic products must not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or Retailer for recycling advice. Product number: D Document number: D773180/3 July 2009
Welcome to LogIT Explorer
Welcome to LogIT Explorer LogIT Explorer is designed to enhance and develop science with young students, utilising the latest technology and design to provide the ideal link between real hands-on science
More informationUser Manual and operating guide
User Manual and operating guide Edition 1.0 0416 Welcome to LogIT Observer Service and Support This manual is based on Observer having the following software versions: Observer Firmware version: 1.03 (Update
More informationInfrared Carbon Dioxide Gas Module ( single beam )
Infrared Carbon Dioxide Gas Module ( single beam ) Wuhan Cubic Optoelectronics Co., Ltd Add:Fenghuang No.3 Road, Fenghuang Industrial Park,Eastlake Hi-tech Development Zone Wuhan 430205, China Tel: 86-27-81628831
More informationDiode Laser Systems In Gas Measurement
Dr Roger Riley, Geotech Diode Laser Systems In Gas Measurement The application of laser diodes for improved biogas analysis Figure 2 Tuneable diode laser measurement technique Introduction The online analysis
More informationCONTENTS. Note: If using Alkaline Rechargeable battery place solar panel under light source for 6 hours with rechargeable battery in place to charge.
WS-6020U-IT FAQS The links below will work in most PDF viewers and link to the topic area by clicking the link. We recommend Adobe Reader version 10 or greater available at: http://get.adobe.com/reader
More informationENGLISH S-CO2 AMBIENT AIR SENSOR INSTALLATION AND OPERATING INSTRUCTIONS CO 2. TF5701_B_v1_web
S-CO2 CO 2 AMBIENT AIR SENSOR INSTALLATION AND OPERATING INSTRUCTIONS ENGLISH TF5701_B_v1_web 1 DESCRIPTION This module measures carbon dioxide (CO 2 ) in the range of 0 to 2 000 ppm and is equipped with
More informationTWS 16 HT UHF wireless system. user manual
TWS 16 HT UHF wireless system user manual Musikhaus Thomann e.k. Treppendorf 30 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-66 E-mail: info@thomann.de Internet: www.thomann.de 30.04.2012 Table
More informationIntelligent Infrared CO2 Module (Model: MH-Z19)
Intelligent Infrared CO2 Module (Model: MH-Z19) User s Manual (Version: 1.0) Valid from: 2015.03.03 Zhengzhou Winsen Electronics Technology Co., Ltd ISO9001 certificated company Statement This manual s
More informationPHOTO FRAME STRING LIGHTBOXES
PFL-500CD PHOTO FRAME STRING LIGHTBOXES Candlenut Distressed Wood Frame USER MANUAL NEED HELP? Call our help line 1-866-765-3686 or visit us at: www.polaroidlightboxes.com Polaroid, Polaroid & Pixel, Polaroid
More informationIntelligent Infrared CO2 Module (Model: MH-Z19B)
Intelligent Infrared CO2 Module (Model: MH-Z19B) User s Manual (Version: 1.0) Valid from: 2016.01.21 Zhengzhou Winsen Electronics Technology Co., Ltd ISO9001 certificated company Statement This manual
More informationSubminiature Photoionization VOC Sensor Boris Dolgov, Baseline-MOCON, Inc.
Subminiature Photoionization VOC Sensor Boris Dolgov, Baseline-MOCON, Inc. Lyons, CO 80540, USA (303) 823-6661 boris.dolgov@baseline.cc 1 1. Objective Monitoring of Volatile Organic Compounds (VOCs) is
More informationa Loop System LA240 User manual ACCESS TO SOUND
a Loop System LA240 User manual ACCESS TO SOUND The LA240 Loop System provides a practical solution for hearing aid users to listen more easily to their TV or Audio equipment via the T or Loop program
More informationAlways there to help you. Register your product and get support at AJ3200. Question? Contact Philips.
Always there to help you Register your product and get support at www.philips.com/support Question? Contact Philips AJ3200 User manual Contents 1 Important 2 Safety 2 2 Your clock radio 3 Introduction
More informationAlways there to help you. Register your product and get support at AJ3200. Question? Contact Philips.
Always there to help you Register your product and get support at www.philips.com/support Question? Contact Philips AJ3200 User manual Contents 1 Important 2 2 Your clock radio 2 Introduction 2 What's
More informationS-SERIE INDOOR AIR QUALITY SENSORS OPTIMIZE AIR QUALITY AND ENERGY OF YOUR HVAC INSTALLATIONS WITH THE NEW S-SERIE SENSORS
S-SERIE INDOOR AIR QUALITY SENSORS OPTIMIZE AIR QUALITY AND ENERGY OF YOUR HVAC INSTALLATIONS WITH THE NEW S-SERIE SENSORS 2 AERECO Sensor range INDOOR AIR QUALITY, A QUESTION OF BALANCE Most of the new
More informationIntroduction...1 Overview...2. Beacon Transmitter...7. Beacon Receiver Trouble Shooting...15
MoTeC Lap Beacon Manual Contents Introduction...1 Overview...2 Operation...2 ID Number...3 Lap Beacon Use...4 Split Beacon Use...4 Verifying Operation...5 Beacon Transmitter...7 Position...7 Spacing between
More informationAlways there to help you. Register your product and get support at AJ4300. Question? Contact Philips.
Always there to help you Register your product and get support at www.philips.com/support Question? Contact Philips AJ4300 User manual Contents 1 Important 2 Safety 2 2 Your clock radio 3 Introduction
More informationCarbon Monoxide (CO) and Carbon Dioxide (CO 2 ) Meter With Air Temp/RH Measurements and Dew Point/Wet Bulb calculations
User Manual Carbon Monoxide (CO) and Carbon Dioxide (CO 2 ) Meter With Air Temp/RH Measurements and Dew Point/Wet Bulb calculations Model CO260 Additional User Manual Translations available at www.extech.com
More informationPLA-240. Small Room Loop Amplifier System. USER Manual MAN 211A
PLA-240 Small Room Loop Amplifier System USER Manual MAN 211A Overview Thank you for purchasing the PLA 240 Small Room Loop Amplifier System. The PLA 240 Loop System provides a practical solution for hearing
More informationVoltage sensor (Product No. 3162) Range: ±1 V Resolution: 1 mv. Voltage sensor (Product No. 3161) Range: 0 to 10 V Resolution: 10 mv
(Product No. 3162) Range: ±1 V Resolution: 1 mv (Product No. 3161) Range: 0 to 10 V Resolution: 10 mv (Product No. 3160-12) Range: ±12 V Resolution: 10 mv (Product No. 3160) Range: ±20 V Resolution: 10
More informationM1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL
M1 Series Humidity - Temperature Transmitter INSTRUCTION MANUAL 20031110 -2- CONTENTS Overview... 3 Operation... 4 Power supply... 4 Operating range and limits... 4 Temperature compensation of the humidity
More informationfree solo HT UHF wireless system user manual
free solo HT UHF wireless system user manual Musikhaus Thomann e.k. Treppendorf 30 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 22.01.2013 Table
More information3x Magnification. Digital Zoom to 6x. CAUTION: Do not point Infrared Emitter directly into eye at close range.
MxGenPRO MANUAL-English.qx_MxGenPRO Manual-English 12/16/14 9:24 AM Page 3 Instruction Manual 3x Magnification. Digital Zoom to 6x. CAUTION: Do not point Infrared Emitter directly into eye at close range.
More informationWIRELESS 868 MHz TEMPERATURE STATION Instruction Manual
WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual INTRODUCTION: Congratulations on purchasing this fancy 868MHz Temperature Station which displays the time, indoor temperature and indoor humidity,
More informationfree solo HT UHF wireless system user manual
free solo HT UHF wireless system user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de
More informationAlways there to help you. Register your product and get support at AE2430. User manual
Always there to help you Register your product and get support at www.philips.com/support AE2430 User manual Contents 1 Important 2 Safety 2 Notice 3 2 Your Portable Radio 5 Introduction 5 What s in the
More informationInstructions For Installing A Pig Fence
Instructions For Installing A Pig Fence A Multi-wire Fence on a Single Line of Posts Height: 18 Inches Polywire for seasonally removable fences Aluminum wire for permanent fences These pages provide the
More informationImportant safety instructions
MMR-88 Version 1 Important safety instructions 1. 2. 3. 4. 5. 6. 7. 8. 9. Please read these instructions carefully. Please keep these instructions for future reference. Heed all warnings Follow all instructions
More informationfree solo PT UHF wireless system user manual
free solo PT UHF wireless system user manual Musikhaus Thomann e.k. Treppendorf 30 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 22.01.2013 Table
More informationRoline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL
Roline L1 Series Humidity - Temperature Transmitters INSTRUCTION MANUAL 20030314 CONTENTS Overview... 3 Operation... 5 Power supply... 5 Operating range and limits... 5 Temperature compensation of the
More informationInfrared Carbon Dioxide Sensor Module CM1106-Single Beam
Infrared Carbon Dioxide Sensor Module CM1106-Single Beam Brief introduction Single Beam (Single light source, single wavelength) NDIR CM1106 (Miniature size) can be used to detect CO2 concentration of
More informationInfrared Carbon Dioxide Sensor Module CM1108-Dual Beam
Infrared Carbon Dioxide Sensor Module CM1108-Dual Beam Introduction Dual beam (single light source, dual wavelength) CM1108 CO2 gas sensor module is mainly used to detect CO2 concentration by adopting
More informationUser s Guide. USB Microscope. Version 1.2A
User s Guide USB Microscope Version 1.2A Contents 1. Product Introduction... 2 1.1 Packing Contents:... 2 1.2 Start to use... 2 1.3 Buttons on microscope... 4 1.4 Microscope focus... 5 2. Printed Notice...
More informationCONTENTS. Batteries. Half of all warranty issues can be resolved with fresh batteries of the appropriate voltage. La Crosse Technology, Ltd.
308-1409BT-308-1409WT FAQS The links below will work in most PDF viewers and link to the topic area by clicking the link. We recommend Adobe Reader version 10 or greater available at: http://get.adobe.com/reader
More informationALPHASENSE USER MANUAL. Toxic Sensor Evaluation Board Issue 4
ALPHASENSE USER MANUAL Toxic Sensor Evaluation Board 072-0128 Issue 4 Introduction This Evaluation Board accepts Alphasense A, B and D Series toxic gas sensors. The purposes of this evaluation board is
More informationUser manual. Air humidity and temperature moisture meter humimeter RH2. Version 2.3_en Schaller GmbH 2016
User manual Air humidity and temperature moisture meter humimeter RH2 Version 2.3_en Schaller GmbH 2016 Distributore autorizzato : Geass S.r.l. - Torino - Tel.: +39.011.22.91.578 - mail : info@geass.com
More informationfree solo HT 1.8 GHz UHF wireless system user manual
free solo HT 1.8 GHz UHF wireless system user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Deutschland Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de
More informationTWS 16 BT UHF wireless system. user manual
TWS 16 BT UHF wireless system user manual Musikhaus Thomann e.k. Treppendorf 30 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 email: info@thomann.de Internet: www.thomann.de 09.03.2012 Table
More informationGR FAQS. La Crosse Technology, Ltd. Page 1
308-1410GR FAQS The links below will work in most PDF viewers and link to the topic area by clicking the link. We recommend Adobe Reader version 10 or greater available at: http://get.adobe.com/reader
More informationD3400 digital power amplifier. user manual
D3400 digital power amplifier user manual Musikhaus Thomann e.k. Treppendorf 30 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 email: info@thomann.de Internet: www.thomann.de 18.11.2011 Table
More informationCONTENTS. La Crosse Technology, Ltd. Page 1
WT-5220U-IT FAQS The links below will work in most PDF viewers and link to the topic area by clicking the link. We recommend Adobe Reader version 10 or greater available at: http://get.adobe.com/reader
More informationTechnical data sheet TDS0037
Technical data sheet TDS0037 PREMIER CARBON DIOXIDE SENSOR NON-CERTIFIED VERSION TYPE MSH-P-CO2/NC Patent Numbers Great Britain GB 2 401 432 & GB 2 403 291 Europe EP 1544603 & EP 1818667-Pending France
More informationUser manual. paper moisture meter RH5.1 with sword-sensor
User manual paper moisture meter RH5.1 with sword-sensor version 2.0_en Schaller GmbH 2012 User manual Positioning the instrument Insert the sword-sensor into the stack for only approx. 10 cm, and push
More informationOperating Instructions
FM Transmitter 2 Operating Instructions PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE. Before Use Please read IMPORTANT SAFETY INSTRUCTIONS on pages 10-11
More informationfreeu HT, freeu PT UHF wireless system user manual
freeu HT, freeu PT UHF wireless system user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de
More informationWIRELESS 868 MHz TEMPERATURE STATION Instruction Manual
WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual INTRODUCTION: Congratulations on purchasing this temperature station with wireless 868 MHz transmission of outdoor temperature and display of indoor
More informationRegister your product and get support at AE5430. EN User manual
Register your product and get support at www.philips.com/welcome AE5430 User manual Concents 1 Important 4 Hearing Safety 4 English 2 Your FM/DAB+ radio 5 Introduction 5 What s in the box 5 Overview of
More informationInstallation instructions
Installation instructions T70RX-03AIB, T70RX-03AWB, T70TX-02TTB, T70TX-03STB, T70TX-06TTB LANGUAGE: English (original) IM-T70-RX001-A01-EN CONTENTS Chapter 1: CUSTOMER INFORMATION 3 Chapter 2: PRODUCT
More informationWireless CO 2. + TRH Sensor. Installation Guide. Version 1
Wireless CO 2 + TRH Sensor Installation Guide Version 1 2 CO2 + TRH Sensor Installation Guide Introduction The wireless CO 2 + TRH (Carbon Dioxide + Temperature and Relative Humidity) sensor is a wall
More informationSee Page 8 for Part Numbers
Amplifier P/N 10023056 Amplifier Kit P/N 10024074 Amplifier RI P/N 10051289 Amplifier RI Kit P/N 10051290 ClearCommand Communications System OPERATING AND MAINTENANCE INSTRUCTIONS Voice Amplifier/Radio
More informationHAWK5000 Operators Manual
HAWK5000 Operators Manual Keison Products P.O. Box 2124, Chelmsford CM1 3UP, England Tel: +44 (0) 1245 600560 Fax: +44 (0) 1245 600030 Email: sales@keison.co.uk www.keison.co.uk KANE INTERNATIONAL LIMITED
More informationfree solo PT UHF wireless system user manual
free solo PT UHF wireless system user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de
More informationWall Mounted E-BUS CO 2. Sensor Technical Guide
Wall Mounted E-BUS CO 2 Sensor TABLE OF CONTENTS OVERVIEW... 3 Features... 3 Environmental Requirements... 3 WALL MOUNTED E-BUS CO 2 WIRING TO DDC CONTROLLER... 4 TROUBLESHOOTING... 5 Setting The Sensor
More information11. ONLY USE attachments/accessories specified by the manufacturer.
U H F Table of Contents System Components...1 Functions of the ECDR Receiver...2 HH38 Handheld Transmitter...3 MBP38 Bodypack Transmitter...4 Tips for Improving System Performance...5 Frequency...6 Specifications...7!
More informationWIRELESS MOTION SENSOR USER MANUAL MULTI LANGUAGE START-LINE TRANSMITTER APIR-2150
START-LINE TRANSMITTER APIR-2150 USER MANUAL MULTI LANGUAGE Item 71091 Version 1.0 Visit www.trustsmarthome.com for the latest instructions WIRELESS MOTION SENSOR 1 2 3 4 5 6 7 8 9 10 11 EN APIR-2150 WIRELESS
More informationfree solo PT UHF wireless system user manual
free solo PT UHF wireless system user manual Musikhaus Thomann Treppendorf 30 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 30.06.2015, ID: 296201,
More informationmix 502, mix 802, mix 1202FX mixer user manual
mix 502, mix 802, mix 1202FX mixer user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de
More informationDM 800H Twin Handheld UHF System (863.0Mhz-865.0Mhz)
DM 800H Twin Handheld UHF System (863.0Mhz-865.0Mhz) User Manual Order code: MIC78 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before
More informationV6889 IMPORTANT! KEEP INSTRUCTIONS FOR FUTURE REFERENCE. sher-price.com.au
V6889 IMPORTANT! KEEP INSTRUCTIONS FOR FUTURE REFERENCE. www.fi sher-price.com.au IMPORTANT! DANGER To prevent electric shock, do not immerse in water; wipe clean with damp cloth. WARNING To prevent strangulation
More informationPARTS INCLUDED TOOLS & PARTS NEEDED Do not mount on vibrating surfaces. appro to 2.5 meters 12M
Type: RH60B-LED Ref: 86524 The bulkhead light incorporates a PIR (Passive Infra Red) sensing device which continuously scans a preset operating zone and immediately switches the lamp on when it detects
More informationUSER'S MANUAL UHF BAND
USER'S MANUAL I UHF BAND MICROPHONE SYSTEM I 1440-8120-01 NOTE. HmmHmmmJ i... 1 FCC Statement MICROPHONE SYSTEM Table of Contents 1. Introduction......... 1 2. Safety... 1 3. Environment... 1 4. Wireless
More informationOPUS20 Multiple Functions with Internal Sensors
Measurement OPUS20 Multiple Functions with Internal Sensors Functions THI 8120.00 THIP 8120.10 TCO 8120.20 Power supply battery Power supply USB Power supply LAN (POE) optional optional optional Measured
More informationNU2. Dual UHF Wireless System. Item ref: UK, UK, UK, UK User Manual. Version 1.0
NU2 Dual UHF Wireless System Item ref: 171.974UK, 171.975UK, 171.976UK, 171.977UK User Manual Version 1.0 Caution: Please read this manual carefully before operating Damage caused by misuse is not covered
More informationTWS One Headset UHF wireless system. user manual
TWS One Headset UHF wireless system user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de
More informationGuide. Installation. Wilson Electronics, Inc. Direct Connection High Power iden Amplifi er 800 MHz Band. Contents:
Amplifier Installation Guide Direct Connection High Power iden Amplifi er 800 MHz Band Contents: Guarantee and Warranty 1 Before Getting Started / How it Works 3 Installing a Wilson Outside Antenna - In-Vehicle
More informationInfrared Carbon Dioxide Sensor Module CM1106-Single Beam
Infrared Carbon Dioxide Sensor Module CM1106-Single Beam Brief introduction Single Beam (Single light source, single wavelength) NDIR CM1106 (Miniature size) can be used to detect CO2 concentration of
More informationAlways there to help you. Register your product and get support at AJ3232. Question? Contact Philips.
Always there to help you Register your product and get support at www.philips.com/support Question? Contact Philips AJ3232 User manual Contents 1 Important 2 Safety 2 2 Your clock radio 3 Introduction
More informationIEM 200 R UHF receiver. user manual
IEM 200 R UHF receiver user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 17.11.2015,
More informationUltrasonic Diagnostic Tool. Users Manual. Read this manual thoroughly before use
Ultrasonic Diagnostic Tool Users Manual Read this manual thoroughly before use 2280 PRINCIPLE Moving parts, liquids and gases cause turbulence or friction. This turbulence or friction can then produces
More informationDigital Wireless Weather System
Digital Wireless Weather System Thermometer, Hygrometer and Heat Index with Remote Sensor Leading the Way in Accuracy 1458 Instruction Manual C H CHANNEL Congratulations on your purchase of the Taylor
More informationInstromet Weather Systems Ltd. Climatica Weather Station User Guide
Instromet Weather Systems Ltd Climatica Weather Station User Guide Contents: 1) Introduction 2) Specifications 3) Package Contents 4) Installation 5) Operating instructions 6) Multi Weather display Features
More informationUser s Manual. abc Text & Go Motion VTech Printed in China
User s Manual abc Text & Go Motion 2012 VTech Printed in China 91-001633-007 INTRODUCTION Thank you for purchasing the VTech abc Text & Go Motion. The abc Text & Go Motion combines preschool curriculum
More informationQAC910. Meteo Sensor. Synco living
2 702 Synco living Meteo Sensor QAC910 Wireless sensor for acquiring outside temperature and atmospheric pressure RF communication based on KNX standard (868 MHz, unidirectional) Battery-powered by commercially
More informationPower Supply. Note: you can t charge the standard battery or rechargeable battery via Mains operation. 2
MMR-77 GB Version 1 1 1 2 3 4 5 6 7 8 9 Controls AM/FM band switch Emergency buzzer Dynamo power AM/FM band indicator Tuning LED indicator Charging LED indicator Illumination button Dial scale Dial pointer
More informationPR-D5 中文 GB. Version 1
PR-D5 中文 GB Version 1 1. 2. 3. Important safety instructions Read and understand all safety and operating instructions before the radio is operated. Retain instruction: The safety and operating instructions
More informationDARK ACTIVATED COLOUR CHANGING NIGHT LIGHT KIT
TEACHING RESOURCES SCHEMES OF WORK DEVELOPING A SPECIFICATION COMPONENT FACTSHEETS HOW TO SOLDER GUIDE CREATE SOOTHING LIGHTING EFFECTS WITH THIS DARK ACTIVATED COLOUR CHANGING NIGHT LIGHT KIT Version
More informationINSTRUCTION MANUAL. 150x Power Student Microscope Biological Experiments Gear 1.5V WARNING: WARNING: NOT INCLUDED
6+ AGES INSTRUCTION MANUAL X2 NOT INCLUDED 1.5V Do not mix old and new batteries. Do not mix alkaline, standard (carbon-zinc), or rechargeable (ni-cad, ni-mh, etc.) batteries. 150x Power Student Microscope
More informationtesto Leakage detector for refrigerants Instruction manual
testo 316-3 Leakage detector for refrigerants Instruction manual 2 1 Contents 1 Contents 1 Contents... 3 2 Safety and the environment... 4 2.1. About this document... 4 2.2. Ensure safety... 4 2.3. Protecting
More informationINDEX. Accessories and Components System Unit and Joystick Assembly and Charging the Battery Using with LED System...
USER GUIDE INDEX Accessories and Components... 4 System Unit and Joystick... 6 Assembly and Charging the Battery... 9 Using with LED System... 11 What is Ground Setting and How It Is Done... 14 Ground
More informationRoom air quality sensors
1 961 QPA10 / QPA20 1961P01 1961P02 QPA20 D Room air quality sensors QPA10.. QPA20.. Maintenance-free sensing element (depending on type) based on optical infrared absorption measurement (NDIR 1) ) Or
More informationSeries 1. Remote. Multiple Mode Remote Controlled Electro Stimulation Control Unit. User Manual
Series 1 Remote Multiple Mode Remote Controlled Electro Stimulation Control Unit User Manual Issue 5.0 March 2010 WELCOME 4 2 Key Features 4 WHAT'S IN THE KIT? 5 Contents 5 Quick Guide 5 Before Use 5 USING
More informationTWS 16 PT UHF wireless system. user manual
TWS 16 PT UHF wireless system user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 17.11.2015,
More informationPair of PMR446 Two-Way Personal Radios Model: TP391
Pair of PMR446 Two-Way Personal Radios Model: TP391 USER MANUAL MANUALE D USO MANUEL DE L UTILISATEUR BEDIENUNGSANLEITUNG MANUAL DE USUARIO MANUAL DO USUÁRIO HANDLEIDING BRUKSANVISNING P/N:086L004722-016
More informationGoyen 2000 Flue Gas Analyzer Two Sensors (O 2, CO)
Goyen 2000 Flue Gas Analyzer Two Sensors (O 2, CO) CO Sensor (0-8000 ppm) 300mm Probe (800 o C max) with 3m Dual Hose, longer & high temp. probes optional External Water Trap with Filter Cartridge Rechargeable
More informationIntelligent Infrared Carbon Dioxide Module (Model: MH-Z14)
Intelligent Infrared Carbon Dioxide Module (Model: MH-Z14) User s Manual Zhengzhou Winsen Electronics Technology CO., LTD. Statement The copyright of this manual belongs to Zhengzhou Winsen Electronics
More informationRemote Control Outlets Operating Instructions
Remote Control Outlets Operating Instructions - FOR INDOOR OR OUTDOOR USE - IMPORTANT SAFEGUARDS Signal Word Definitions NOTE: These are general definitions only; all may not pertain to the actual product
More informationLocator Accessories INSTRUCTION MANUAL
Locator Accessories INSTRUCTION MANUAL Signal Clamp Signal Injector General Purpose Sonde 33kHz General Purpose Sonde 8kHz Metal Pipe Sondes 512Hz / 640Hz Duct Sonde 33kHz 20m & 50m Plastic Pipe Tracers
More informationWelcome 1. Precaution
Table of Contents EN Precaution....2 Preparation.. 4 Standard accessories....4 Parts Names & Functions...5 Computer System requirements.... 6 Technical Specifications 7 Install the software.. 7 Start Microscope.8
More informationTWS One Vocal UHF wireless system. user manual
TWS One Vocal UHF wireless system user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de
More informationRegister your product and get support at AE2430. User manual
Register your product and get support at AE2430 EN User manual English 1 Important Safety Important Safety Instructions a b c d e f g h i j k Read these instructions. Keep these instructions. Heed all
More informationR S / R 100ppb 0.1. Fig. 1: R S /R 0 as a function of gas concentration at 50% RH and 25 C.
MiCS-2610 O 3 Sensor This datasheet describes the use of the MiCS-2610 in ozone detection applications. The package and the mode of operation described in this document target the detection of the oxidising
More informationRed/Far-Red Sensor SKR 110. Skye Instruments Ltd., 21 Ddole Enterprise Park, Llandrindod Wells, Powys LD1 6DF UK Tel: +44 (0)
SKR 110 Skye Instruments Ltd., 21 Ddole Enterprise Park, Llandrindod Wells, Powys LD1 6DF UK Tel: +44 (0) 1597 824811 skyemail@skyeinstruments.com www.skyeinstruments.com Iss. 1.1 Skye Instruments Ltd.
More informationBlockMon Block Monitor LongMon Long Monitor
BlockMon Block Monitor LongMon Long Monitor Bypass range 2.2V to 5.0V. Bypass current 0A to 2A (typically 1A). Over-voltage protection up to ±20V. Noise immune opto-isolated. Cell temperature and bypass
More informationOperating Instructions
LR650 Operating Instructions This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment you are connecting this product to. Comply with all
More informationKWM Quartet Wireless microphone system
KWM Quartet Wireless microphone system M A N U A L V E R S I O N 2. 0 2 4-1 1-1 4 Professional UHF wireless system with 4 x USB rechargeable handheld microphones Due to continuous product development,
More informationINSTRUCTION MANUAL INF Fax: (503)
INSTRUCTION MANUAL INF151 1-800-547-5740 Fax: (503) 643-6322 www.ueiautomotive.com email: info@ueitest.com Introduction Congratulations on your purchase of the INF151 infrared thermometer. Like all UEi
More informationInstruction Manual T5140 T5141 T5145 T5240 T5241 T5245. Programmable transmitter of CO2 concentration with 4-20 ma output. with 0-10 V output
www.cometsystem.com Instruction Manual T5140 T5141 T5145 Programmable transmitter of CO2 concentration with 4-20 ma output T5240 T5241 T5245 Programmable transmitter of CO2 concentration with 0-10 V output
More informationOPUS20 LAN-Datalogger Future Inside
OPUS20 LAN-Datalogger Future Inside a pa ssio n fo r pr ecis ion pa ssion po ur la préc is ion pasi sión por la pr ec isió ió n pa ssio ne per la pr ecis isio ione a www.lufft.com Measurement OPUS20 THIP
More informationTemp / RH / CO 2 Hand-Held Meter
Temp / RH / CO 2 Hand-Held Meter PRODUCT MANUAL Item # 3440 CONTENTS Specifications 2 Battery 3 LCD Display 3 Keypad 3 Operation 4 Troubleshooting 7 Warranty 8 CE Declaration of Conformity 8 Thank you
More informationContents. English 1. French 29. Spanish. FEATURES: The Temperature Station
Contents Language Page English 1 French 29 Spanish Topic Page Inventory of Contents 2 Features 3 Setting Up Battery Installation 7 Function keys 9 LCD Screen and Settings 11 Manual Settings 13 Viewing
More information