OPERATOR ADAPTER ECHV

Similar documents
OPERATOR ADAPTER SQDV

OPERATOR ADAPTER A21ABVA

OPERATOR ADAPTER APCABVA

OPERATOR ADAPTER A21SDA

OPERATOR ADAPTER A21WHA

4832A Installation Sheet Part List

Oxford Stalls Installation Instructions

F l a t S c r e e n A R M S I n s t a l l a t i o n

PRE-ENGINEERED HORSE STALL SYSTEMS SDFD SLIDING DOOR c/w FOLD-DOWN GRILL. & Assembly. Installation Instructions

INSTRUCTIONS TS93 GSR PT RIGHT HAND ACTIVE LEFT HAND INACTIVE RIGHT HAND INACTIVE LEFT HAND ACTIVE

DEPTH-KIT-785 Seat Depth Extension

PRO / PL SHOE REPLACEMENT & CONVERSION INSTRUCTIONS

CATALOG OF REPLACEMENT PARTS

TOOLS REQUIRED FOR ASSEMBLY. Rubber Mallet or Plastic Tip Hammer PARTS REQUIRED FOR ASSEMBLY OF SINGLE ENTRY STARTER.

EZ-Lock Assembly Manual

TIRE RACK INSTALLATION INSTRUCTIONS Dodge Sprinter

40670 Transit Connect/NV200/City Express/ProMaster City Partition

Parts Catalog. S-Series Slicer Manual Frozen Option S13. Model:

Assembly Instructions 10 X 10 Aluminum Frame Building

AndyMark DART 12.

D3976 RECESSED EXIT INSTALLATION INSTRUCTIONS

WPS crew Doors Installation instructions

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

Introduction. Rocky Mountain Westy Swing Away Carrier Kit Installation Instructions

RH-412 STEEL DOORS INSTALLATION INSTRUCTIONS

Hopper and Drive Components

33/3527A. Devices covered by these instructions: 33/3527A-F (Fire) Surface Vertical Rod Exit Device

Storage Cabinets 9000 Series Assembly Instructions

INSTALLATION INSTRUCTIONS RH 412 STEEL DOORS

INSTALLATION GUIDE FTX FLOOR Ford Transit ( 148" Extended Wheelbase )

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

INSTALLATION INSTRUCTIONS HEAVY DUTY TILT WALL MOUNT Model: PPH-2000

FLOE DOCK FURNITURE WARNING ASSEMBLY INSTRUCTIONS

Hopper and Drive Components

INSTALLATION GUIDE Locker With Top Shelf Transit Low Roof & Nissan NV Low Roof ( Aluminum )

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

INSTALLATION INSTRUCTIONS

Parts Catalog. S-Series Slicer Smart Manual SG13. Model:

APS Small Seeds Box Assembly Instructions

Speaker Mount Center Channel Speaker Adapter (PAC-301)

INSTALLATION INSTRUCTIONS, AND PARTS LIST

PPM-5710 JK HEAVY DUTY SKID PLATE ASSEMBLY Version 2.0

Calf-Tel Pen System Assembly Instructions

3/8-16 x 3/4 cap screw. 3/8-16 hex nut for above screws. 1/4-20 x 3/4 socket cap screw. 3/16 short arm hex key (not to scale)

P.O. Box 8400 Green Bay, WI (920)

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

RBP-1215B-RX DODGE RAM QUAD CAB RX3

Assembly Instructions 10 X 10 Aluminum Roof Support

Workbench Instructions for Assembly

Bulkhead Model Number and

INSTALLATION GUIDE N5-DS48-4

GF 12II. Parts Manual MODEL: Aug 2001 P/N Rev B A10605

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

KU-BAND FEED INSTALLATION OMT INTERFACE

Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

Warnings. Description. Prior to Installation Tools Needed

CATALOG OF REPLACEMENT PARTS

Tire Chain Kit. Replacing Shear Pins. Weight Kits. Drift Cutter

33/35A Series. Devices covered by these instructions: Rim Exit Device. CD33/35A Rim Exit Device EL33/35A Rim Exit Device SS33/35A Rim Exit Device

Toyota 4 Runner and Lexus GX Skid Plate installation instructions.

4832L Installation Sheet Part List

Power Break II Circuit Breakers

COMPONENTS AND BOX CONTENTS

Installation Guide 40670

Honda. Pioneer 1000 & U.H.M.W. Skid Plate / Under Armor package. Installation guide

Installing the CACS Ceiling with Aisle Ducts

Dublin Stalls Installation Instructions

Closet Carousel Installation Instructions. Models TKA 5 Through TKA 14 Equipped with Footswitch Controls

Installation Instructions

PRE-ENGINEERED HORSE STALL SYSTEMS 4884 HSD STANDARD SLIDING DOOR. & Assembly. Installation Instructions

INSTALLATION INSTRUCTIONS FOR PLASCORE NARROW STILE DOORS

55000/55010 Installation Instructions

Installation Instructions

SS1062, SS10621 & SS10621E Free Standing PWC & Fishing Boat Hoist SS1062 SS10621 SS10621E

SM-RAZOR-F-M/L/XL. Strong Low Profile Fixed Mount for Ultra-Thin Flat-Panel TVs INSTALLATION MANUAL

98/9927. Devices covered by these instructions: Surface Vertical Rod Exit Device

Pro-Lock Retrofit Instruction Manual

This Folding Shelf Kit will work in conjunction with our Swing Away Carrier Kit allowing you add additional exterior storage space to your Vanagon.

Track Rack. * Track Racks are not lockable

TITAN2-EDGE Public Access Computer Station Dual Track

CAPX Installation Print 4/10/ CAB ASSEMBLY Part Pos Description Quantity Foot Notes CAB SECTION PLATE, MO

Installation Instructions

Medium HoneyBadger Chase Rack Installation Instructions

96 (Standard Length)

351 DOOR CLOSER WITH DOUBLE LEVER ARM (OP) INSTALLATION INSTRUCTIONS

OFS ED-6C Instruction Sheet LIGHTGUIDE CROSS-CONNECT Comcode: LGX DISTRIBUTING FRAME INSTALLATION

4099T Parts List. Front Bow Assy. (1) Rear Bow Assy. (1) Long Mounting Rail (2) Short Mounting Rail (2)

MSP-DCCPGSU Large Screen Static Display Mount

INSTALLATION INSTRUCTIONS

FRAME BRACKET. Doing Our Best to Provide You the Best. Ford F250, F350 & F parts list. Page 1. 2/17 HJ32002,Rev 2.

MSP-DCCPGTU Large Screen Tilt Display Mount

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

Eaton Data Center Racks

Diva Acoustical Ceiling

Installation Instructions - Model V4JSD 1

WORKSURFACE ASSEMBLY

INSTRUCTION, BMRA COUPLING BOLT FIELD KIT

TIP FOR GETTING STARTED

INSTALLATION INSTRUCTIONS AND PARTS LIST MODEL , O-MEGA II 6 OVAL STEPS

CheckMate Lawn Striping Kit Installation Guide: CC600

Transcription:

OPERATOR ADAPTER ECHV Installation Instructions for Eaton Cutler-Hammer C361 and C371 Variable Depth Operating Mechanisms (For parts list, see Page 2) Rev. A 2014 Pentair Equipment Protection PH 763 422 2211 pentairprotect.com P/N 89114655 89115496

Parts List Operator Adapter, Catalog Number ECHV, for Eaton Cutler-Hammer C361, C371 Disconnects Item No. Description Part No. Qty. 1 MOUNTING PLATE, C-H C361 AND C371 26385001 1 2 GASKET, PLATE 89109613 1 3 SCREW, 1/4-20X1/2 PAN HEAD 99401031 4 4 SLIDE ARM 26250001 1 5 SHOULDER COLLAR 26149001 1 6 SCREW, 1/4-20X7/8 HEX HEAD 99401030 1 7 LOCKWASHER, 1/4 SPRING 99401318 1 8 WASHER, FLAT 22101003 2 9 LOCKWASHER, 1/4 INTERNAL TEETH 99401300 2 10 NUT, 1/4-20 HEX 99401406 2 11 DOOR CATCH 23101002 1 12 SCREW, 10-32X3/8 PAN HEAD 99401007 2 13 LOCKWASHER, #10 INTERNAL TEETH 99401307 2 14 NYLON WASHER 26132003 4 15 INSTALLATION INSTRUCTIONS 89114655 1-2 - 2014 Pentair Equipment Protection PH 763 422 2211 pentairprotect.com 89115496

INTRODUCTION This installation instruction is for Eaton Cutler-Hammer C361, C371 (variable depth) mechanisms. These mechanisms are for disconnect switches and circuit breakers mounted in Hoffman two-door floor-mounted, Bulletin A21 enclosures with the disconnect on the right flange. INSTALLATION STEPS Step 1 Install mounting plate (item1) and plate gasket (item 2) on the inside of the enclosure, behind the rectangular opening provided. Gasket side with PSA should be attached to the adapter plate. Secure in place with four screws (item 3) and four nylon washers (item 14). Step 2 Discard the Cutler Hammer spring bracket which is normally installed inside the enclosure flange, behind the C H handle mechanism. Step 3 Assemble the Cutler Hammer handle mechanism to the mounting plate which was installed in the enclosure in step 1. Omit cap screw and lockwasher which fits into bottom hole of the handle mechanism. Step 4 Install the slide arm (item 4) over the defeater part of the handle assembly (on C H handle mechanism) with notch toward door opening, as shown. Place the smaller diameter end of the shoulder collar (item 5) through the oval slot in the slide arm. Install long cap screw (item 6) with lockwasher (item 7) through shoulder collar into the bottom mounting hole of the C H handle mechanism and tighten. The slide arm and defeater should move up and down smoothly. Install door hasp (C H part) per Cutler Hammer instructions. Step 5 Attach the bottom of the slide arm (item 4) to the offset arm of the lock release mechanism. Use two flat washers (item 8), two lockwashers (item 9), and two hex nuts (item 10). Do not tighten until parts are adjusted (see step 6B) Step 6 The handle safety lock release mechanism is adjustable in two places. (A) Check the adjustment of the factory installed roller bracket. The door latch should hit against the latch stop portion of the roller bracket when the door is closed and latched. Adjust up or down if necessary. The attached mechanism will then provide the necessary up down motion required to operate the release mechanism in the C H handle mechanism. (B) Adjust the length of the slide arm assembly. With proper adjustment of the slide arm, the safety lock(on Cutler Hammer handle mechanism) should release just before the master door is fully latched. Lengthen slide arm if safety lock releases too soon. Shorten slide arm if safety lock releases too late. Step 7 Attach the door catch (item 11), provided by Hoffman, to the tapped spacer on the door using the bottom set of mounting holes. Use two screws (item 12) and lockwashers (item 13). The door catch prevents the door from being opened when the handle mechanism is in the ON position. Step 8 Drill and tap holes in panel per Eaton Cutler-Hammer instructions. See Eaton Cutler Hammer instructions for locating extra holes for fuse clips. Step 9 Mount switch or circuit breaker using Eaton Cutler-Hammer instructions and parts. C-H connecting rod must be cut off per Eaton Cutler- Hammer instructions. 89115496 2014 Pentair Equipment Protection PH 763 422 2211 pentairprotect.com - 3 -

For Floor-Mounted, Two-Door Enclosures with Disconnect on Right Flange - 4-2014 Pentair Equipment Protection PH 763 422 2211 pentairprotect.com 89115496

INTRODUCTION This installation instruction is for Eaton Cutler Hammer C361, C371 (variable depth) mechanisms. These mechanisms are for disconnect switches and circuit breakers mounted in Hoffman one through six door, free standing Bulletin A28M1, A34Y and A4L3D enclosures with the disconnect on the right flange. INSTALLATION STEPS Step 1 Install Mounting plate (item 1) and plate gasket (item 2) on the inside of the enclosure, behind the rectangular opening provided. Gasket side with PSA should be attached to the adapter plate. Secure in place with four screws (item 3) and four nylon washers (item14). Step 2 Discard the Cutler Hammer spring bracket which is normally installed inside the enclosure flange behind the C H handle mechanism. Step 3 Assemble the Cutler Hammer handle mechanism to the mounting plate which was installed in the enclosure in step 1. Omit cap screw and lockwasher which fits into bottom hole of the handle mechanism. Step 4 Install the slide arm (item 4) over the defeater part of the handle assembly (on C H handle mechanism) with notch toward door opening, as shown. Place the smaller diameter end of the shoulder collar (item 5) through the oval slot in the slide arm. Install long cap screw (item 6) with lockwasher (item 7) through shoulder collar into the bottom mounting hole of the C H handle mechanism and tighten. The slide arm and defeater should move up and down smoothly. Install door hasp (C H part) per Cutler Hammer instructions. Step 5 Attach the bottom of the slide arm (item 4) to the offset arm of the lock release mechanism. Use two flat washers (item 8), two lockwashers (item 9), and two hex nuts (item 10). Do not tighten until parts are adjusted. (see step 6B) Step 6 The handle safety lock release mechanism is adjustable in two places. (A) Check the adjustment of the factory installed roller bracket. The door latch should hit against the latch stop portion of the roller bracket when the door is closed and latched. Adjust up or down if necessary. The attached mechanism will then provide the necessary up down motion required to operate the release mechanism. (B) Adjust the length of the slide arm assembly. With proper adjustment of the slide arm, the safety lock (on Cutler Hammer handle mechanism) should release just before the master door is fully latched. Lengthen slide arm if safety lock releases too soon. Shorten slide arm if safety lock releases too late. Step 7 Attach the door catch (item 11), provided by Hoffman, to the tapped spacer on the door using the bottom set of mounting holes. Use two screws (item 12) and lockwashers (item 13). The door catch prevents the door from being opened when the handle mechanism is in the ON position. Step 8 Drill and tap holes in panel per Eaton Cutler Hammer instructions. See Eaton Cutler-Hammer instructions for locating extra holes for fuse clips. Step 9 Mount switch or circuit breaker using Eaton Cutler Hammer instructions and parts. Eaton Cutler Hammer connecting rod assembly must be cut off per Cutler Hammer instructions. 89115496 2014 Pentair Equipment Protection PH 763 422 2211 pentairprotect.com - 5 -

For One Through Six Door Free-Standing Enclosures with Disconnect on Right Flange - 6-2014 Pentair Equipment Protection PH 763 422 2211 pentairprotect.com 89115496

INTRODUCTION This installation instruction is for Eaton Cutler Hammer C361, C371 (variable depth) mechanisms. These mechanisms are for disconnect switches and circuit breakers mounted in Hoffman two door, floor mounted Bulletin A21 enclosures with the disconnect on the centerpost. INSTALLATION STEPS Step 1 Install Mounting plate (item 1) and plate gasket (item 2) on the inside of the enclosure, behind the rectangular opening provided in the centerpost. Gasket side with PSA should be attached to the adapter plate. Secure in place with four screws (item 3) and four nylon washers (item 14). Step 2 Discard the Cutler Hammer spring bracket which is normally installed inside the enclosure flange behind the C H handle mechanism. Step 3 Assemble the Cutler Hammer handle mechanism to the mounting plate which was installed in the enclosure in step 1. Omit cap screw and lockwasher which fits into bottom hole of operating handle. Step 4 Cut 2 1/2 off bottom end of slide arm (item 4). (bottom end has rectangular holes only) Step 5 Install the slide arm (item 4) over the defeater part of the handle assembly (on C H handle mechanism) with notch toward door opening, as shown. Place the smaller diameter end of the shoulder collar (item 5) through the oval slot in the slide arm. Install long cap screw (item 6) with lockwasher (item 7) through shoulder collar into the bottom mounting hole of the C H handle mechanism and tighten. The slide arm and defeater should move up and down smoothly. Install door hasp (C H part) per Cutler Hammer instructions. Step 6 Attach the bottom of the slide arm (item 4) to the offset arm of the lock release mechanism. Use two flat washers (item 8), two lockwashers (item 9), and two hex nuts (item 10). Do not tighten until parts are adjusted. Step 7 Adjust the length of the slide arm assembly. With proper adjustment of the slide arm, the safety lock (on Cutler Hammer handle mechanism) should release just before the master door is fully latched. Lengthen slide arm if safety lock releases too soon. Shorten slide arm if safety lock releases too late. Step 8 Attach the door catch (item 11), provided by Hoffman, to the tapped spacer on the door using the bottom set of mounting holes. Use two screws (item 12) and lockwashers (item 13). The door catch prevents the door from being opened when the handle mechanism is in the ON position. Step 9 Drill and tap holes in panel per Eaton Cutler-Hammer instructions. See Eaton Cutler Hammer instructions for locating extra holes for fuse clips. Step 10 Mount switch or circuit breaker using Eaton Cutler Hammer instructions and parts. Eaton Cutler Hammer connecting rod assembly must be cut off per Cutler Hammer instructions. * NOTE: Optional channel support kit, Eaton Cutler Hammer C371 CS6, is recommended when installing 600 AMP. circuit breakers in 72 1/8 high enclosures. 89115496 2014 Pentair Equipment Protection PH 763 422 2211 pentairprotect.com - 7 -

For Floor-Mounted, Two Door Enclosures with Disconnect on Centerpost - 8-2014 Pentair Equipment Protection PH 763 422 2211 pentairprotect.com 89115496