Wiring Diagrams. Part F, Section 1. This section covers the following unit congifurations. F3EN [3V - A - AAAX] V Issued 5/00

Similar documents
Wiring Diagrams. Part B, Section 3. This section covers the following unit configurations V Issued 7/01 B3EN-05-[3V-A-AAAX]-4

Schematics. Part B, Section 4

Schematics. Part B, Section 4. This section covers the following unit congifurations. Model 3830 Voltage 1, 2 Pump AC Gear (K or L)

Schematics. Part B, Section 4. This section covers the following unit congifurations. Model 3100, 3400 Voltage 1 Pump Piston (E or G)

Schematics. Part B, Section 4. This section covers the following unit congifurations. Model 3500 Voltage 1 Pump Piston (E, F or G) 6-Port (B or C)

Schematics. Part B, Section 4. This section covers the following unit congifurations. Model 3100, 3400 Voltage 1, 2 Pump Piston (E or G)

Schematics. Part B, Section 4. This section covers the following unit congifurations. Model 3500 Voltage 1, 2 Pump Piston (E, F or G) 6-Port (B or C)

Schematics. Part B, Section 4. This section covers the following unit congifurations. Model 3100 and 3400 Voltage 1, 2 Pump Piston (E or G)

Installation of Fillmaster DuraBlue Melters. System on. Introduction. Instruction Sheet P/N B

Operation. Section 4. Additional Information. Operation 4-1

400/480 Volt ProBlue Adhesive Melters

P/N B ProBlue and DuraBlue Thermostat Service Kit - P/N

Technical Data for 3400 Melters

AWUF Series. Wall-Mount Air Handler 1½ to 3 Tons. Contents. Product Features

ProHelp Systems MIU 10X/98 WIRING / INSTALLATION INSTRUCTIONS

Inscription Area/Color Labeling Accessories W H Order No. Price Packing Illustration Description mm mm 1 Pkg. 1 Pkg.

Installation Manual February Model 752E Phase Selector Model 754E Phase Selector Model 760E Card Rack Model 759 Auxiliary Interface Panel

2016 Edition V3.0 LED DRIVER PRODUCT CATALOGUE

POINTAX 6000L2 Point Recorder

Instruction Sheet P/N _06 5/2014

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

Earth Leakage Monitoring System IsoBase IsoHub IsoOut

Brief description of KR 15 controllers

Optional end of travel limit switches for user setting of minimum and maximum pressure values.

Optional end of travel limit switches for user setting of minimum and maximum pressure values.

Series 7 Power Controllers

C E R A M I C S. Mo t i f

Microprocessor Control Board Set Up Procedures (OR PLC)

Model 2400 Explosion-Proof M/P Converters -- LOCK IN LAST POSITION --

Blue Point Engineering

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES

LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual. IM-LZSA500-3 January 2008 Revision H

INSTALLATION AND OPERATING INSTRUCTIONS

SC30-SM2 Series Signal Conditioners

Current Loop Interface Module M-2025C

Photoelectrics Amplifier, µ-processor Controlled Type PAM, 2-10 Inputs/2-10 Transistor Outputs

Effective october 14, 2014

John Deere. MODEL: 116 & 116H Lawn Tractors JD-P-PC1871

REIMESCH KOMMUNIKATIONSSYSTEME GMBH ALPIN HF / 50MHz Linear Amplifier - USER MANUAL. v1.1

Level Limit Switch nivotester FTL 325 P

Flickerless / Dim Power supply

Flickerless / Dim Power supply

ROCKER SWITCHES B 1 SERIES 3A SPECIFICATIONS AGENCY APPROVALS

SIEMENS ENERGY & AUTOMATION INC DISTRIBUTION PRODUCTS DIV

Mark Scheme (Results) January 2011

Glim Cube iguzzini. design Piero Castiglioni SPECIFIC LIGHTING EFFECT LUMINAIRES. Easy maintenance (lamps have longer life)

GB/GW GB/GW GB/GW GB/GW

USER MANUAL LDY CW Diode Driver Power Supplies

THT TYPE. Interface unit with built-in DO module FEATURES

RODIX INCORPORATED rd Ave., ROCKFORD IL TOLL FREE (800) , FAX (815)

C0330, C0530, C0630, C0830, C1030 Service Parts

M1014 7" x 12" Metal Cutting Bandsaw PARTS -38-

A.O. SMITH WATER PRODUCTS COMPANY 5621 W. 115TH STREET ALSIP, ILLINOIS Phone: Fax:

WC 1 WELD SEQUENCE CONTROLLER. Operation / Installation Manual Manual Part Number: C8M5002 Date: July 9, 2002 Revised: July 24, 2003

12 30 ripple included external fuse 3,0 A Current consumption A 1,0 2,6 depending from solenoid current. V ma. V ma. Output current A 1,0-1,6-2,6

Bloodhound Working Dog (16/pp) quiltartdesigns.blogspot.com

Instructions MODIFICATION KIT MODEL SBM - 1O2-1 INTRODUCTION PARTS LIST FOR THE

BECAUSE MOTOR & GENERATOR FAILURE IS NOT AN OPTION USCG

Flickerless / Dim Power supply

PAM & SAM System User s Manual

Impulse system MPT 700. Manual Edition GB

USER MANUAL XLB-650 Short Arc Xenon Lamp Ballast

Outdoor. PISE-A150D (Pb-Free) 150W Output Power with DALI. Features. Critical Specifications. Input Specifications. Output Specifications IP66

Programmable AC Power Source Model 9801

FEATURES DESCRIPTION THE OEM ADVANTAGE

DIGITAL FEEDER CONTROL

RTD-Style Special e.dot Hot Melt Hoses

2010 Irrigation Products Illustrated Parts Breakout

SERVO CONTROLLER. Sdtork Introduce Digital Servo Controller with several Features for all type of Valve Automation.

Experiment No. 6 Output Characteristic of Transistor

Bill Kneller 20 January 2008 Rev. 12 Dec 2012 TackTick T111 Dual Digital Display (Mast Bracket)

Owner s Manual S10 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL

PACSystems* RX3i and Series 90-30

Section M. GS CONSOLIDATED ELECTRONICS and GS NEXGEN ELECTRONICS

DX450 Red-D-Arc PARTS LIST FOR RETURN TO MAIN INDEX

Integrated servo motor

Current Loop Interface Module M 2025D

DMX Digital-Servo Board

NX series Constant and variable torque Variable Speed Drives for induction motors

NOTE: The relay coil is polarity sensitive

LBI-38392C IC DATA MAINTENANCE MANUAL LOGIC BOARD U707 OCTAL DATA LATCH 19D902172G1 & G2 TABLE OF CONTENTS

Field Network SRT Series

Standard Configuration

PKG-341-MLA-CBL System Diagram and Specifications

8WD4 Signaling Columns

Cybex Arc Trainer 630A Owner s Manual. Main Assembly

M AUTOMATIC MATTRESS PACKING MACHINE

Design Characteristics. FlexDrive II. Series

Red: PAINTED ITEMS Blue: KITS IPDA2

C E R A M I C S. Motif

AAA Balanced / Unbalanced Line Audio Interface Amplifiers. User Manual. I.R.T. Communications Pty Ltd

WEBS-MT/R Tower Installation Instructions

USER MANUAL XLB-2500 Short Arc Xenon Lamp Ballast

Features. Introduction. Applications. Ordering Information

ADTECH Solar inverter

- Wiring Brochure Universal Reset Module 423e

Fan and Pump AC Inverter

RODIX INCORPORATED rd Ave., ROCKFORD IL TOLL FREE (800) , FAX (815)

Outdoor 25 W Dimmable SL-L KR

SIGMA TEK, INC. 1U /-003 COMM / NAV / DME / ATC RADIO CONTROL PANEL INSTALLATION MANUAL. Publication No. 86M072

Transcription:

Part F, Section Wiring Diagrams This section covers the following unit congifurations. Model All Voltage All Pump All Manifold All Control All E 000 Nordson Corporation -000V Issued /00 FEN - 0 - [V - A - AAAX] -

F-0 Wiring Diagrams FEN - 0 - [V - A - AAAX] - -000V Issued /00 E 000 Nordson Corporation

Wiring Diagrams F- Section F Wiring Diagrams. Introduction The wiring diagrams contained in this section are based on the voltage code of your unit. Refer to the following table to determine the voltage code of your unit; then refer to the appropriate wiring diagram in this section. Unit Voltage Code Table F - Unit Voltage Codes and Applicable Wiring Diagrams Specification Type of service you can connect to the unit: (See Note A) 00--0 Vac or AC 0 or /PE AC 00--0V Part of this section to refer to: 00--0 Vac (two wire service without a neutral) Voltage Code and Wiring Diagram 00--0 Vac (three wire service without a neutral) /N/PE AC 00/0V 0 Vac (two wire service, including a neutral) Voltage Code and Wiring Diagram 00/0 Vac (four wire service, including a neutral) AC 00V 00 Vac (three wire service without a neutral) Voltage Code Wiring Diagram AC 0 V 0 Vac (three wire service without a neutral) Voltage Code Wiring Diagram NOTE A: This specification is printed in the VOLTS (ac) portion of the identification plate on your unit.. Use of Wiring Diagrams Each wiring diagram is contained on two facing pages. Sometimes a wire shown on one page is connected to terminals or components shown on the facing page. In these cases, the connecting wiring is labeled on each page with the same letters. For example, if you want to trace a wire or harness labeled BL on the left page, look for a wire or harness labeled BL on the right page. Each wiring diagram shows all of the options or special features the unit can be equipped with. Options and special features are indicated by dotted lines. To determine the features and options of your unit, refer to Explanation of Configuration Code at the end of the Description section. E 000 Nordson Corporation -000V Issued /00 FEN - 0 - [V - A - AAAX] -

F- Wiring Diagrams. Voltage Code a nd Wiring Diagram This wiring diagram applies to voltage code and units only. Refer to Table F - to determine the voltage code of your unit. ON/OFF I/O BK SIGNALS BM BL J F PL TB0 & TB0 XS XS INDICATOR XP DISPLAY I/O BOARD PC ENGINE X TB XP K PL J XP RS/RS COMMUNICATIONS F0 XPA XP XP F F F F F F F F F F T TBB TBC T KEYPAD XP XP L L L N X XP XP BOARD DIGITAL PROCESSOR BOARD TB J NOTE: FOR AC GEAR PUMP UNITS JUMPER IS USED ON J XP WARNING GND (PE) METAL GND FRAME FAULT XP NOT READY XP0 XP 0 0 0 X X J J BXP NO CONNECTION XS XS XPB 0 0 0 CG CE TSTAT BC XPA 0 0 0 CI CH PNEUMATIC VALVE (NOT USED WITH AC GEAR PUMP OPTION) TANK OVERTEMP THERMOSTAT 0 0 0 0 TANK/RES HC GUN HC GUN HC GUN HC HG HG HG GUN HG TANK/RES G FRAME G REAR G FRONT G TOP COVER G EXPANSION SE PLATE G HG, HG, GRID G, AC G, G HOPPER COVER G0 PARTS IN DOTTED LINES ARE OPTIONAL GND (PE) 0A Fig. F - Wiring Diagram for Voltage Code and Units ( of ) FEN - 0 - [V - A - AAAX] - -000V Issued /00 E 000 Nordson Corporation

Wiring Diagrams F- XC & XC CONNECTIONS 00-0 V PHASE XC XC 00-0 V PHASE XC XC AC OVERTEMPERATURE THERMOSTAT M G XC BK TRIGGER IN ENABLE IN BL OR XSB BM OR XSB XP 0 V PHASE XP L F L F L F N XP XC XP XC CONTACTOR BOARD BC GROUND STACK LIST XC SOURCE WIRE LOCATION FRAME REAR H/G H/G TANK/RES FRONT TOP COVER EXP. SEPLATE H/G H/G G G HG HG G G G G JC XC 00 V/0 V PHASE A A D D A B B D HG C HG H/G HG H/G HG GRID G B G G A BRACKET HOPPER COVER G0 B XP XC GUN VALVE K XSA,B,C XSA,B,C,D XSA,B XSA JC XP PATTERN DRIVER BOARD C GUN VALVE JUMPER WHEN GRID NOT PRESENT CC B C LEVEL C LEVEL D LEVEL LEVEL C LEVEL D XSC OR BM A XSC OR BL TO AC BOARD XSM F / HOSE/GUN BOARD XSH XSH F ON/OFF LED F F F F K + -- XSM C RUN START SWITCH (SSW) CSTART XH XH 0 XH 0 X & X CONNECTIONS 00-0 V PHASE K CI CH XSGR X X X XSM AC RUN/START (00/0 V UNITS) PARTSINDOTTEDLINESAREOPTIONAL Fig. F - Wiring Diagram for Voltage Code and Units ( of ) K DETAIL A CE 00 V/0 V PHASE BXP XGR XSGR GRID BOARD C RUN AC START SWITCH CSTART HC HC 00-0 V PHASE X X X K M YELLOW BLUE RED 0 V PHASE CHOKE CG CC S RUN/START (00--0 V UNITS) SEE DETAIL A FOR 00/0 V UNITS GUN HG GUN GRID TSTAT G HG G HG, HG G, G, G 0A E 000 Nordson Corporation -000V Issued /00 FEN - 0 - [V - A - AAAX] -

F- Wiring Diagrams. Voltage Code Wiring Diagram This wiring diagram applies to voltage code units only. Refer to Table F - to determine the voltage code of your unit. I/O BK SIGNALS PL DISPLAY PL TB0 & TB0 I/O BOARD J XP PC ENGINE XP XP XPA XP XP KEYPAD XP BOARD XP DIGITAL PROCESSOR XP NO CONNECTION BXP BE XP 0 0 0 0 0 0 0 0 0 Y X 0 0 HC HC GUN HG GUN HG RS/RS COMMUNICATIONS XP HC ON/OFF J F INDICATOR X TB K F0 F F F F F F F F F F T TBB TBC T XP L L L N X BOARD BB BB TB WARNING FAULT NOT READY GND (PE) METAL GND FRAME X X J XS XS J TSTAT BC PNEUMATIC VALVE TANK OVERTEMP THERMOSTAT 0 0 HC GUN HG GUN HG FRAME G REAR G FRONT G TOP COVER G EXPANSION SE PLATE G PARTS IN DOTTED LINES ARE OPTIONAL G GND 0A Fig. F - Wiring Diagram for Voltage Code Units ( of ) FEN - 0 - [V - A - AAAX] - -000V Issued /00 E 000 Nordson Corporation

Wiring Diagrams F- L L L N GROUND STACK LIST SOURCE WIRE LOCATION FRAME REAR H/G H/G TANK FRONT TOP COVER EXP. SEPLATE H/G H/G H/G H/G 00:0 TRANSFORMER COM 0 V 00 V SURGE GUARD Z F F F G G HG HG G G G G XC HG HG CONTACTOR BOARD HG HG A D D A B B D C C C D Z SURGE GUARD XC BC BB BB JC C COM COM 0V 00V D B K XSA,B,C XSA,B,C,D XSA,B XSA A JC LEVEL LEVEL LEVEL LEVEL LEVEL 00:0 TRANSFORMER SE XSH XSH / HOSE/GUN BOARD F F F F BXP BE XT AC_ TH TH 00 V TANK BOARD BK TRIGGER IN ENABLE IN XSB XSB XH XH X Y A B C D 0 XH 0 XP XP XP XP 00 V TANK HC HC GUN HG GUN GUN GUN XP HG G,HC,HC XP PATTERN DRIVER BOARD PARTS IN DOTTED LINES ARE OPTIONAL 0A Fig. F - Wiring Diagram for Voltage Code Units ( of ) E 000 Nordson Corporation -000V Issued /00 FEN - 0 - [V - A - AAAX] -

F- Wiring Diagrams. Voltage Code Wiring Diagram This wiring diagram applies to voltage code units only. Refer to Table F - to determine the voltage code of your unit. I/O BK SIGNALS PL DISPLAY PL TB0 & TB0 I/O BOARD J XP PC ENGINE XP XP XPA XP XP KEYPAD XP BOARD DIGITAL PROCESSOR XP0 XP XP XP S XP 0 0 0 XPB 0 0 0 Y X R 0 0 HC HC GUN HG GUN HG RS/RS COMMUNICATIONS XP HC BM BL ON/OFF XS XS J F0 F X TB K F F F F F F F F F F T TBB TBC T A B XP X BOARD TB WARNING FAULT NOT READY X X J XS XS J TSTAT AA PNEUMATIC VALVE TANK OVERTEMP THERMOSTAT 0 0 HC GUN HG GUN HG FRAME G REAR G FRONT G TOP COVER G EXPANSION SE PLATE G HOPPER COVER G0 TANK G HOSE/GUN HG HOSE/GUN HG GND 0A Fig. F - Wiring Diagram for Voltage Code Units ( of ) FEN - 0 - [V - A - AAAX] - -000V Issued /00 E 000 Nordson Corporation

Wiring Diagrams F- 0 Vac -- Vdc SSRELAY CM CL INCOMING 0 Vac GROUND STACK LIST SOURCE WIRE LOCATION FRAME REAR H/G H/G TANK FRONT TOP COVER EXP. SEPLATE H/G H/G H/G H/G EXP. XFMR BRACKET 0 Vac DISTRIBUTION BOARD TB F L TBC F L TBB L T PE METAL END--FRAME G G HG HG G G G G HG HG HG HG T F XD J A A A D D A B B B C C C D A J AA S R L L L L 0 0 0 COM XFMR 0/0 0 COM F K T T T T C A XD CHASSIS 0 Vac TANK XDA D B XDB A XD LEVEL LEVEL LEVEL LEVEL + XD X Y A B C D INPUT OUTPUT G CL CM BK TRIGGER IN ENABLE IN BL BM HG G,HC,HC XP XP XH 0 XP F XSH F GUN XP XH F HC XSH F HG / HOSE/GUN BOARD XH 0 GUN GUN GUN XP XP PATTERN DRIVER BOARD HC Fig. F - Wiring Diagram for Voltage Code Units ( of ) 0A E 000 Nordson Corporation -000V Issued /00 FEN - 0 - [V - A - AAAX] -

F- Wiring Diagrams FEN - 0 - [V - A - AAAX] - -000V Issued /00 E 000 Nordson Corporation