Electrical Specifications

Similar documents
Electrical Specifications

POWER. NLP40 Series. Single, Dual and Triple Output. Data Sheet

Electrical Specifications

NLP40 SERIES 50 Watt Open Frame Power Supply Measures: 4.25 x 2.50 x 1.15

Electrical Specifications. Adjustment range Main output ± 5% Total regulation (line and load) ± 2.0% ± 5.0% Turn-on 120 Vac Input 2.0 s max.

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26

1 V/ms V typ. Track input voltage: Pin 8 (See Note 6, page 3) ± 0.3 Vin

PTH03060Y & PTH05060Y PTH12060Y. Vin increasing Vin decreasing PTH05060Y PTH12060Y PTH12060Y

PTH03010Y & PTH05010Y PTH12010Y. Vin increasing Vin decreasing PTH05010Y PTH12010Y PTH12010Y

Electrical Specifications

Electrical Specifications

POWER. CPS250-M Series. 250 Watt AC-DC Power Supplies. Data Sheet. Total Power: 250 Watts Input Voltage: V # of Outputs: Single

POWER. CPS250-M Series. 250 Watt AC-DC Power Supplies. Data Sheet. Total Power: 250 Watts Input Voltage: V # of Outputs: Single

Electrical Specifications

General. Environmental. EMC & Safety

These medical power supplies are ideal for, monitoring, home health equipment as well as surgical devices.

150 Watt Industrial (WLT)

Electrical Specifications

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

Electrical Specifications

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

Electrical Specifications Input

EIGHTH-BRICK SERIES. Single Output Value Products. Special Features

QUARTER-BRICK QUARTER-BRICK SERIES. Single Output Ultra Products. Special Features

C B. Models. Models 2MOPP

LDO03C SERIES. Single Output. LDO03C Series 3 A DC-DC C Class Non-Isolated DC/DC Converter [ 2 YEAR WARRANTY ]

EIGHTH-BRICK SERIES. 24 V Input, Single Output. Special Features

Electrical Specifications

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

POWER DS Watts Distributed Power System. Data Sheet

These medical power supplies are ideal for monitoring, home health equipment as well as surgical devices.

Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

MAD40 MULTI -OUTPUT SERIES OPP SCP OVP. 2 X 3.5 Inch AC-DC POWER SUPPLIES. UNIVERSAL INPUT RANGE UP TO 40Watts PART NUMBER STRUCTURE LOW CROSS REG.

VP ELECTRONIQUE MASSY - Tel:

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

420 W High Line Output Power. Rugged Industrial Construction. -40 C to +70 C Operation. 5 V Standby. Screw Terminals. SEMI F47 Compliant

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

Electrical Specifications. Input Current 115 VAC: 1.2 A max. 230 VAC: 0.65 A max.

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

5 x 3 x 0.75 Inches form factor. 275 Watts with Forced Air Cooling. Efficiencies up to 92% Standby Power < 0.5 W

ABC Series power supplies are ideal for telecom, datacom, industrial equipment and other applications.

ABC Series power supplies are ideal for telecom, datacom, industrial equipment and other applications.

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

Compliance. Safety Approvals USA Canada Europe. Isolation: General. Dimensions. AC Input CN1 Output CN2 Optional CN3. Weight

EXQ125 48V SERIES. Single Output. Special Features

ECC100 Series. -40 ºC to +75 ºC Operation. 100 W - Baseplate Cooled. High Efficiency Resonant Topology. Screw Terminals Available.

POWER CSV1300BP Watts Distributed Power System. Electrical Specifications. Data Sheet

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max.

CCH400 & CCH600 Series

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1. Automation Datacom IPC. Industry Measurement Telecom

Power Supplies. Certifications and Compliances Recognized Component, ITE - UL Certified, ITE - CSA C22.2 CSA

CLP0112 Open Frame Power Supply Vac input; 12Vdc output; 150W Output Power

LB115S 115W Single Output

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

Electrical Specifications. Input range Vac (Operating) 115/230 Vac (Nominal) TERMINAL BLOCK Frequency Hz, Nominal 50/60

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

VOF XX - XXX - X

POWER CSV900BP. 900 Watts Distributed Power System. Electrical Specifications. Data Sheet

QUARTER-BRICK SERIES. Dual Output Value Products. Special Features

Metal Case Power Supplies

POWER CSV2000BP Watts Distributed Power System. Electrical Specifications. Data Sheet

ECP225-A Series. 225 Watts. AC-DC Power Supplies. Models & Ratings

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 115VAC to 78% at 90VAC)

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

Output Voltage* (nom.)(adjustable)

General. Environmental. EMC & Safety

TB65 65W Single Output Test and Measurement/Industrial Series

POWER DS1100PED Watts Distributed Power System. Electrical Specifications. Data Sheet

POWER DS3000PE High Line: 3000 W Low Line: 1350 W. Electrical Specifications. Data Sheet

XSOLO ULTRA-COMPACT, HIGH-EFFICIENCY 500 W AND 1000 W SINGLE OUTPUT POWER SUPPLIES

AC-DC ITE & Medical Switching Power Supply

The MBC550 range is ideally suited to a wide variety of medical applications, and also where airflow is limited or not available.

Electrical Specifications. > 0.9 beginning at 20% load. ITHD 10% Leakage current. Ordering Information

Watts HCP Series

Output Voltage (Vfan) Convection-cooled (6,7) Forced-cooled (8) & Current

Output Power Output Voltage (3) Output Current Total Regulation (2) Efficiency (5) Model Number (1,6) 8 W 3.3 VDC 2.50 A 7% 68% AEL15US03 (4) 12 W

SF60/61P & SFU60/61P Series

LFWLP W 12V 15.00A 25.00A 92%

PDAM500 Series 500W Power Supply

PM24S/DR24S series 60W Single Output DC/DC Converter

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

POWER CSU550AP. 550 Watts Distributed Power System. Electrical Specifications. Data Sheet

POWER DS750PED. 750 Watts Distributed Power System. Electrical Specifications. Data Sheet

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

M A D 65 U S 12 B - PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

For more information, please visit the product page. output. output current max (A)

MI2000ERW. Series. Miniature 1 x 1 20W, Ultra-Wide 2:1 Input DC/DC Con vert ers. Key Features:

CLP0224 Open Frame Power Supply Vac input; 24Vdc output; 200W Output Power

Output Voltage (Vfan) & Current

Series AM20EW-Z 20 Watt DC-DC Converter

POWER DS250SPE. 250 Watts Distributed Power System. Electrical Specifications. Data Sheet

Output Full Load

Transcription:

Single & Quad output 1 of 5 Total Power: 80-110 W Input Voltage: 85-264 Vac 120-370 Vdc # of Outputs: Single, quad Special Features 7.0 x 4.25 x 1.8 inch package Overvoltage and short circuit protection 110 W with 20 CFM Adjustable outputs EN55022, EN55011 conducted emissions level B UL, VDE and CSA safety approvals CE mark Available RoHS compliant 2 year warranty Safety VDE0805/EN60950/ IEC950/IEC1010 File No. 10401-3336-0213 Licence No. 4001467 7 UL1950 File No. E132002 CSA C22.2 No. 950 File No. LR41062C Electrical Specifications Output Voltage adjustability: +5.1 V o/p on multi s 5.1 V single output 12 V single output 15 V single output 24 V single output All specifications are typical at nominal input, full load at 25 C unless otherwise stated 3.0% 3.0% 12-14 V 15-18 V 24-30 V Line regulation: LL to HL, FL ±0.1% max. All outputs on all units Overshoot/undershoot: At turn-on 0% Temperature coefficient: All outputs ±0.02%/ C Overvoltage protection: Multi o/p 5.1 V only 5.1 V single output 12 V single output 15 V single output 24 V single output 6.25 V ± 0.75 V 6.25 V ± 0.75 V 15.75 V ± 1.0 V 22 V ± 1.5 V 33 V ± 2.5 V Output power limit: Primary power limited Pin max. 160 W Pout min. 110 W Minimum output current: (See Note 13) 0 A Short circuit protection: Input Input voltage range: Input frequency range: Burst mode operation Input surge current: 230 Vac 35 A Safety ground leakage current: 110 Vac, 50 Hz 230 Vac, 50 Hz 85-264 Vac 120-370 Vdc 47-440 Hz 0.2 ma, max. 0.4 ma, max.

2 of 5 EMC Characteristics Conducted emissions: EN55022, FCC part 15 Level B Radiated emissions: EN55022, FCC part 15 Level A ESD air: EN61000-4-2, level 3 Perf. criteria 1 ESD contact: EN61000-4-2, level 4 Perf. criteria 1 Surge: EN61000-4-3, level 3 Perf. criteria 1 Fast transients: EN61000-4-4, level 3 Perf. criteria 1 Radiated immunity: EN61000-4-5, level 3 Perf. criteria 2 Conducted immunity: EN61000-4-6, level 3 Perf. criteria 1 General Specifications Hold-up time: Efficiency: Isolation voltage: Approvals and standards: (see note 12) Weight: 110 Vac @ 80 W 110 Vac @ 110 W 230 Vac @ 80 W 230 Vac @ 100 W Multiple outputs +5.1 V single 12 V and 15 V singles 24 V single Input/output Input/chassis 35 ms 17 ms 140 ms 100 ms 70% typical 70% typical 72% typical 75% typical 3000 Vac 1500 Vac VDE0805, EN60950, IEC950, IEC1010, UL1950, CSA C22.2 No. 950 Singles Multiple outputs 550 g (19.4 oz) 600 g (21.2 oz) MTBF (@25 ºC): MIL-HDBK-217E 125,000 hours min. Environmental Specifications Thermal performance: Operating ambient 0 C to +70 C (See notes 9, 10) Non-operating -40 C to +85 C 0 C to 50 C convection cooled 80 W +50 C to +70 C, convection cooled Derate 2 W/ C 0 C to +50 C, 20 CFM forced air 110 W +50 C to +70 C, 20CFM forced air Derate 2.75 W/ C Peak, 0 C to +50 C, max. 60 seconds 110W Relative humidity: Non-condensing 5 to 95% RH Altitude: Operating 10,000 feet max. Vibration: (See Note 11) Non-operating 40,000 feet max. 5-500 Hz 2.4 G rms peak

3 of 5 Ordering Information Output Voltage Max (1) Output Currents Peak (2) Fan (3) Ripple (4) Total (13, 15, F) Model Numbers Regulation (5) +5.1 V 8 A 20 A 10 A 50 mv ± 2.0% NFS110-7601PJ (14) +12 V 4.5 A 9 A 5 A 120 mv ± 3.0% 12 V 0.5 A 1.5 A 1 A 120 mv ± 3.0% 5 V 0.5 A 1.5 A 1 A 50 mv ± 3.0% +5.1 V (I A ) 8 A 20 A 10 A 50 mv ± 2.0% (6, 14) NFS110-7602PJ +24 V (I B ) (6) 3.5 A 4.5 A 4.5 A 240 mv +10/ 5.0% +12 V 4.5 A 9 A 5 A 120 mv ± 3.0% 12 V 0.5 A 1.5 A 1 A 120 mv ± 3.0% +5.1 V 8 A 20 A 10 A 50 mv ± 2.0% NFS110-7604PJ (14) 15 V 4 A 7.5 A 5 A 150 mv ± 4.0% -15 V 0.5 A 1.5 A 1 A 150 mv ± 3.0% -5 V 0.5 A 1.5 A 1 A 50 mv ± 3.0% 12 V 7 A 9 A 9 A 120 mv ± 2.0% NFS110-7612J (7,8) 15 V 5 A 7.3 A 7.3 A 150 mv ± 2.0% NFS110-7615J (7,8) 24 V 3.5 A 4.5 A 4.5 A 240 mv ± 2.0% NFS110-7624J (7,8) Notes 1 Convection cooled, 80 W maximum. 2 Peak outputs lasting less than 60 seconds with duty cycle less than 10%. Total peak power must not exceed 110 W. 3 Forced air, 20 CFM at 1 atmosphere, 110 W maximum. 4 Figure is peak-to-peak. Output ripple is measured across a 50 MHz bandwidth using a 12 inch twisted pair terminated with a 47 µf capacitor. 5 Total regulation is defined as the static output regulation at 25 C, including initial tolerance, line voltage within stated limits and output voltages adjusted to their factory settings. 6 To achieve stated regulation on the 24 V output on the NFS110-7602PJ, the following load condition must be true: I A / I B 5, where: I A = +5.1 V output current, and I B = +24 V output current The +24 V output will maintain ±5.0% regulation under the following additional condition: I A 5 A. 7 Single output models have floating outputs which may be referenced as either positive or negative. Higher voltage supplies may be adjusted over a wide output voltage range, as long as the total output power does not exceed 80 Watts (natural convection) or 110 Watts (forced air). 8 Power fail detect not available on single output models. 9 Derating curve is application specific for ambient temperatures >50 C, for optimum reliability no part of the heatsink should exceed 90 ºC and no semiconductor case temperature should exceed 100 ºC. 10 Caution: Allow a minimum of 1 second after disconnecting the power when making thermal measurements. 11 Three orthogonal axes, random vibration, 10 minute test for each axis. 12 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 13 Recommend a minimum load of 11 W to achieve the design MTBF. See the derating curve on page 4. 14 Power failure detec is optional by including the suffix P to the model number. 15 The J suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. 16 NOTICE: Some models do not support all options. Please contact your local Emerson Network Power representative or use the on-line model number search tool at http://www.powerconversion.com to find a suitable alternative. Transient Response NFS110-7601PJ +5.1 V (7.5 A to 10 A) +12 V (2.5 A to 5 A) -12 V (0.5 A to 1 A) -5 V (0.5 A to 1 A) NFS110-7602PJ +5.1 V (7.5 A to 10 A) +24 V (1.5 A to 3 A) +12 V (2.5 A to 5 A) -12 V (0.5 A to 1 A) NFS110-7604PJ +5.1 V (7.5 A to 10 A) +15 V (2.5 A to 5 A) -15 V (0.5 A to 1 A) -5 V (0.5 A to 1 A) 300 mv peak, 1 ms recovery NFS110-7605J +5.1 V (10 A to 20 A) 250 mv peak, 1 ms recovery NFS110-7612J: +12 V (4.5 A to 9 A) 360 mv peak, 1 ms recovery NFS110-7615J +15 V (3.65 A to 7.3 A) 450 mv peak, 1 ms recovery NFS110-7624J +24 V (2.25 A to 4.5 A) 720 mv peak, 1 ms recovery

AC (J1) mating connector Molex 09-50-3051 or Molex 09-91-0500 mating connector with 2478 or equivalent crimp terminals. DC (J2) mating connector Molex 09-50-3131 or Molex 09-91-1300 mating connector with 2478 or equivalent crimp terminals. AC INPUT 5V OUTPUT PFD SIGNAL OPTIONAL POWER FAIL DETECT TIMING DIAGRAM 4.75V LOW 0-0.4 MAX T1 0.475 (12.07) HIGH T2 4.75V 3.5V MIN T3 Power fail detect signal (Note 8) 50ms T1 200ms T2 will vary with line and load T3 3ms Pout: 110W PFD output is an open collector which will sink 40mA in the low state. 4 of 5 1.80 (45.72) MAX 1.00 0.005 (25.4) 110W DERATING CURVE (See Notes 9, 10) Output Power (Watts) 0.050 0.020 (1.27) 3.35 0.015 (85.09) 1.55 0.005 (39.37) 6-32 UNC (4PL) 80W 20 CFM FORCED AIR COOLING Voltage Adjust PIN 1 4.250 0.020 (107.95) Optional Power Fail Detect Circuit (Key = Pin 2) J2 NATURAL CONVECTION COOLING 55W 40W 3.750 0.005 (95.25) C6 T1 T1 Pin 1 L1 F1 J1 PIN 1 0.156 DIA. HOLE (4PL) 11W 0W 11W MINIMUM LOAD REQUIRED AT 230VAC 0C 10C 20C 30C 40C 50C 60C 70C 0.250 (6.35) 0.250 (6.35) 6.50 0.005 (165.1) 7.00 0.020 (177.8) ALL DIMENSIONS IN INCHES (mm) 5A, 250 VAC Mechanical Notes: A Metallic or non-metallic stand-offs (maximum diameter 5.4mm) can be used in all four mounting holes without effecting safety approval. B The ground pad of the mounting hole near J1, allows system grounding through a metal stand-off to the system chassis. C The heat sink is grounded, and allows system grounding by mechanical connection to the system chassis. D The supply must be mechanically supported using the PCB mounting holes and may be additionally supported by the heatsink mounting holes. E It is always advisable to attach the power supply heat sink to another thermal dissipator (such as a chassis or finned heatsink etc). The resulting decrease in heat sink mounted component temperatures will improve power supply lifetime. F A standard L-bracket and cover is available for mounting which contains all screws, connectors and necessary mounting hardware. The kit is available, order part number NFS110CJ. Pin Connections J1-7601PJ -7602 P -7604PJ Singles Pin 1 AC Ground AC Ground AC Ground AC Ground Pin 2 AC Neutral AC Neutral AC Neutral AC Neutral Pin 3 AC Line AC Line AC Line AC Line J2 Pin 1 +5.1 V +5.1 V +5.1 V V out Pin 2 +5.1 V +5.1 V +5.1 V V out Pin 3 +5.1 V +5.1 V +5.1 V V out Pin 4 Return Return Return Return Pin 5 Return Return Return Return Pin 6 Return Return Return Return Pin 7 Return Return Return Return Pin 8 +12 V +12 V +15 V V out Pin 9 +12 V +12 V +15 V V out Pin 10 PFD PFD PFD N/C Pin 11-12 V -12 V -15 V N/C Pin 12 Removed for Key Pin 13-5 V +24 V -5 V N/C N/C = no connection

Americas 5 of 5 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: www.powerconversion.com techsupport.embeddedpower @emerson.com While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower.com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. 2009 Emerson Electric Co.