Experiment 5 The Oscilloscope

Similar documents
The Oscilloscope. Vision is the art of seeing things invisible. J. Swift ( ) OBJECTIVE To learn to operate a digital oscilloscope.

Oscilloscope Measurements

Department of Electrical and Computer Engineering. Laboratory Experiment 1. Function Generator and Oscilloscope

General Construction & Operation of Oscilloscopes

Oscilloscope. 1 Introduction

CHAPTER 6. Motor Driver

Sirindhorn International Institute of Technology Thammasat University at Rangsit

Introduction to oscilloscope. and time dependent circuits

The University of Jordan Mechatronics Engineering Department Electronics Lab.( ) Experiment 1: Lab Equipment Familiarization

Laboratory 3 (drawn from lab text by Alciatore)

Exp. #2-6 : Measurement of the Characteristics of,, and Circuits by Using an Oscilloscope

LAB 7: THE OSCILLOSCOPE

EECE208 INTRO To ELECTRICAL ENG LAB. LAB 2. Instrumentation

Physics 323. Experiment # 1 - Oscilloscope and Breadboard

Cornerstone Electronics Technology and Robotics Week 21 Electricity & Electronics Section 10.5, Oscilloscope

EE 201 Function / Arbitrary Waveform Generator and Oscilloscope Tutorial

THE CATHODE RAY OSCILLOSCOPE

Electric Circuit II Lab Manual Session #1

2 Oscilloscope Familiarization

Using Circuits, Signals and Instruments

Elizabethtown College Department of Physics and Engineering PHY104. Lab # 9- Oscilloscope and RC Circuit

ENGR 210 Lab 6 Use of the Function Generator & Oscilloscope

FYSP1110/K1 (FYSP110/K1) USE OF AN OSCILLOSCOPE

THE XYZs OF USING A SCOPE

EXPERIMENT 1 PRELIMINARY MATERIAL

Name EET 1131 Lab #2 Oscilloscope and Multisim

Exercise 4 - THE OSCILLOSCOPE

ME 365 EXPERIMENT 1 FAMILIARIZATION WITH COMMONLY USED INSTRUMENTATION

ENGR 1110: Introduction to Engineering Lab 7 Pulse Width Modulation (PWM)

Oscilloscope and Function Generators

Laboratory Exercise 6 THE OSCILLOSCOPE

EECE208 INTRO To ELECTRICAL ENG LAB. LAB 2. Instrumentation

EXPERIMENT NUMBER 2 BASIC OSCILLOSCOPE OPERATIONS

Ph 3455 The Franck-Hertz Experiment

Name Date: Course number: MAKE SURE TA & TI STAMPS EVERY PAGE BEFORE YOU START EXPERIMENT 10. Electronic Circuits

POLYTECHNIC UNIVERSITY Electrical Engineering Department. EE SOPHOMORE LABORATORY Experiment 3 The Oscilloscope

Experiment 9 AC Circuits

EC310 Security Exercise 20

PHYSICS 171 UNIVERSITY PHYSICS LAB II. Experiment 4. Alternating Current Measurement

Lab 0: Orientation. 1 Introduction: Oscilloscope. Refer to Appendix E for photos of the apparatus

Performance-based assessments for AC circuit competencies

Notes on Experiment #1

DEPARTMENT OF INFORMATION ENGINEERING. Test No. 1. Introduction to Scope Measurements. 1. Correction. Term Correction. Term...

Laboratory 1 Generating and viewing signals rev. 20e. Oscilloscope Settings

Introduction to Electronic Equipment

BK PRECISION INSTRUCTION MANUAL. MODELS 2120B and 2125A. 30 MHz DUAL-TRACE OSCILLOSCOPES + PRECISION

5: SOUND WAVES IN TUBES AND RESONANCES INTRODUCTION

Test No. 1. Introduction to Scope Measurements. Report History. University of Applied Sciences Hamburg. Last chance!! EEL2 No 1

PHY152 Experiment 4: Oscillations in the RC-Circuits (Measurements with an oscilloscope)

ECE 480: SENIOR DESIGN LABORATORY

AC Circuits. "Look for knowledge not in books but in things themselves." W. Gilbert ( )

EENG-201 Experiment # 4: Function Generator, Oscilloscope

Laboratory 4. Bandwidth, Filters, and Diodes

University of TN Chattanooga Physics1040L 8/29/2012 PHYSICS 1040L LAB LAB 6: USE OF THE OSCILLOSCOPE

Laboratory Equipment Instruction Manual 2011

LABORATORY 4. Palomar College ENGR210 Spring 2017 ASSIGNED: 3/21/17

ECE65 Introduction to the Function Generator and the Oscilloscope Created by: Eldridge Alcantara (Spring 2007)

ECE 53A: Fundamentals of Electrical Engineering I

Test No. 2. Advanced Scope Measurements. History. University of Applied Sciences Hamburg. Last chance!! EEL2 No 2

2 AC and RMS. To pass this lab you must solve tasks 1-2. Tasks 3 and 4 are included in the grading of the course.

Introduction to Basic Laboratory Instruments

Exercise 1: AC Waveform Generator Familiarization

Combinational logic: Breadboard adders

Massachusetts Institute of Technology Department of Electrical Engineering and Computer Science Circuits and Electronics Fall 2004

Experiment # 1 Introduction to Lab Equipment

ECE3204 D2015 Lab 1. See suggested breadboard configuration on following page!

EEE1016 Electronics I

ELECTRONICS LAB. OSCILLOSCOPE

Ahsanullah University of Science and Technology

BEATS AND MODULATION ABSTRACT GENERAL APPLICATIONS BEATS MODULATION TUNING HETRODYNING

EE EXPERIMENT 1 (2 DAYS) BASIC OSCILLOSCOPE OPERATIONS INTRODUCTION DAY 1

LAB I. INTRODUCTION TO LAB EQUIPMENT

TEST INSTRUMENT SAFETY WARNING

DEPARTMENT OF ELECTRICAL ENGINEERING LAB WORK EE301 ELECTRONIC CIRCUITS

2 : AC signals, the signal generator and the Oscilloscope

AE Agricultural Customer Services Play-by-Play Tekscope Manual

Lab 04. Basic Oscilloscope Operation Capacitor Time Constant. 1. The Oscilloscope.

Physics 310 Lab 2 Circuit Transients and Oscilloscopes

Lab #11 Rapid Relaxation Part I... RC and RL Circuits

LLS - Introduction to Equipment

Experiment #2: Introduction to Lab Equipment: Function Generator, Oscilloscope, and Multisim

MODELLING AN EQUATION

Lab E5: Filters and Complex Impedance

Faculty of Engineering, Thammasat University

ELECTRONIC DEVICES AND CIRCUITS. Faculty: 1.Shaik.Jakeer Hussain 2.P.Sandeep patil 3.P.Ramesh Babu

LAB INSTRUMENTATION. RC CIRCUITS.

30 MHz Oscilloscope Scientech 801C

332:223 Principles of Electrical Engineering I Laboratory Experiment #2 Title: Function Generators and Oscilloscopes Suggested Equipment:

electrical noise and interference, environmental changes, instrument resolution, or uncertainties in the measurement process itself.

The oscilloscope is an essential tool if you plan to design or repair electronic equipment. It lets you "see" electrical signals.

Equipment and materials to be checked out from stockroom: ECE 2210 kit, optional, if available. Analog BK precision multimeter or similar.

Introduction to Oscilloscopes Instructor s Guide

Purpose: 1) to investigate the electrical properties of a diode; and 2) to use a diode to construct an AC to DC converter.

Digital Fundamentals 8/25/2016. Summary. Summary. Floyd. Chapter 1. Analog Quantities

B. Equipment. Advanced Lab

Exercise 2: Demodulation (Quadrature Detector)

OSCILLOSCOPES. Oscilloscopes CS-5300 SERIES RS-232C OPTION OPTION CS-5370P/5370/5350 FEATURES OUTLINE. Photo: CS-5370P

UNIVERSITY OF CALIFORNIA, SANTA BARBARA Department of Electrical and Computer Engineering. ECE 2A & 2B Laboratory Equipment Information

PHYS 3152 Methods of Experimental Physics I E2. Diodes and Transistors 1

Lab 1 - Analogue and Digital Signals

Transcription:

Experiment 5 The Oscilloscope Vision is the art of seeing things invisible. J. Swift (1667-1745) OBJECTIVE To learn to operate a cathode ray oscilloscope. THEORY The oscilloscope, or scope for short, is a device for drawing calibrated graphs of voltage vs time very quickly and conveniently. Such an instrument is obviously useful for the design and repair of circuits in which voltages and currents are changing with time. There are also many devices, called transducers, which convert some non-electrical quantity such as pressure, sound, light intensity, or position to a voltage. By using a transducer the scope can make a plot of the changes in almost any measurable quantity. This capability is widely used in science and technology. The heart of the oscilloscope is a cathode ray tube or CRT, of the sort you have already studied. Looking at the face of the instrument, you are viewing the screen that the electron beam strikes. Electronic circuits in the scope apply voltages to one set of deflection plates to sweep the beam across the screen from left to right at a constant rate, thereby providing the time axis. Other circuits amplify or attenuate the input signal as needed, and apply voltages to the other set of deflection plates to move the beam vertically, providing the voltage axis. Controls are provided to select the time and voltage scales needed for any given situation. At the end of each sweep, the beam is shut off and the horizontal deflection voltage is reset so the beam would start at the left edge of the screen again. Since a scope is usually used to plot a rapidly changing quantity, one sweep and therefore one plot may last only a few microseconds. If the phenomenon we are studying can be made repetitive, we can repeat the sweep sequence many times to get a display suitable for a more leisurely examination. A special circuit, called a trigger circuit, examines the incoming voltage signal and starts the sweep at the same point in the repetitive cycle for each new sweep. This results in a visually steady display of the input. Several controls are provided to set the trigger as needed. The scope you will use is a very flexible instrument, typical of those available in a research laboratory. It has two channels, so that two different voltages may be plotted simultaneously for direct comparison, and a variety of triggering options. The front panel, shown in Fig. 5-1, is correspondingly formidable at first glance. Fortunately, the myriad of controls can PHYS 112 Laboratory Manual 24

Fig. 5-1. Oscilloscope front panel with functional blocks marked. be considered in several independent groups, which are marked in the figure. In the remainder of this section we will examine each group in turn, concentrating on the controls we will need in subsequent experiments. The experimental procedure section will then take you through a series of measurements designed to demonstrate the operation of each section. At the left side of the instrument, the CRT screen is divided into a one centimeter grid, ruled on the inside surface of the tube. Each solid line is one division for the horizontal and vertical deflection. The dotted lines are provided for pulse rise-time measurements. Moving across the panel, we come to the power switch and the CRT controls. The trace rotation and probe adjust are used only when repairing the instrument. The intensity control should be set to give a visible trace, but excessive brightness will defocus the spot and may damage the screen. Both the intensity and focus may need to be adjusted when the sweep rate is changed drastically. The beam finder is provided as an aid to setting the scope. When pushed, it reduces the deflection voltages enough that the beam will always appear on the screen. The position controls are then used to center the spot, and you should obtain a display suitable for final adjustments when the beam finder button is released. PHYS 112 Laboratory Manual 25

CH 1 Attenuator Pre- Amp Delay line Amp EXT INPUT COUPLING Trigger system POSITION MODE VOLTS/DIV Sweep generator Amp CRT control BEAM FINDER FOCUS INTENSITY SOURCE INT/EXT LEVEL SLOPE MODE SEC/DIV MODE The vertical system accepts input signals and develops appropriate deflection voltages for the CRT. Because this is a two-channel scope there are two identical sets of vertical controls, one for each trace. The block diagram in Fig. 5-2 shows the flow of signals in one channel. Voltages are applied between the terminals labeled GND (an abbreviation for ground, discussed below) and either CH 1 or CH 2 for the channel desired. The coupling switch allows the input circuit to accept all signals when set at DC, or only the time-varying part when set for AC. The middle position, GND connects the input to ground, so that you can see where the zero-voltage height is on the screen. (Using the GND setting does not connect the input terminal to ground, so your circuit will not be disturbed.) The position control allows you to place the trace on the screen as desired, for example aligning the zero-voltage position with one of the grid lines. The vertical sensitivity control, labeled VOLTS/DIV is used to set the vertical scale factor. For example, when the 50m marking is next to the 1X symbol, the scope is set for a vertical scale of 50 mv per centimeter, and a deflection of 2 cm, equal to 2 large divisions, would indicate an input voltage of 100 mv. This control is normally set to make the vertical part of the signal a convenient size on the screen. The red knob in the center of the control allows you to continuously vary the vertical scale factor, rather than using the fixed settings. This feature is occasionally useful for relative measurements, but for quantitative work you need to know the calibration, and you must use the fixed steps. Turning the red knob fully clockwise sets the control for the fixed steps marked on the main control. POSITION Fig. 5-2. Block diagram of the oscilloscope, showing the control functions The set of controls labeled VERTICAL MODE select several related functions. Starting at the left, you can display the signal from channel 1, channel 2 or from both channels. The switch at the right determines how the display is done when both channels are in use. In CHOP mode the PHYS 112 Laboratory Manual 26

beam is switched back and forth between the channels very rapidly, drawing many short pieces of the voltage-time graph for both channels as the sweep proceeds. In ALT mode, an abbreviation for alternate sweep, the channel 1 signal is displayed for one full sweep, the channel 2 signal is displayed on the next sweep, and so forth. If the sweep time is short, ALT mode appears to display two steady graphs, but if the sweep time is long you will see an irritating flicker as one line and then the other is swept. The CHOP mode is therefore better for slow sweeps because it draws both traces together, although it cannot switch quickly enough to handle very fast signals. As a general rule, use ALT mode unless the display is slow enough to be irritating, and then switch to CHOP. The third setting, ADD, algebraically adds the input of channel 1 and 2. We will not have much use for this feature. The BW LIMIT (bandwidth limit) button allows you to cut off signals with frequencies higher than 10 MHz, so that they do not appear on the display. Most of our signals are at lower frequencies, so leaving this button in will cut out some noise without losing any information. The CH 2 INVERT button inverts the signal from channel two, so that increasing positive voltages are plotted downward, rather than upward. This button should be out for normal operation. The horizontal system controls the time scale of our plots. The main control, labeled SEC/DIV, works much like the vertical sensitivity controls, with a series of fixed settings and a red variable control. Note that the scale is divided into regions for seconds, milliseconds and microseconds per division. When set for 1 ms/division, as in the figure, each one centimeter division on the screen corresponds to one millisecond. The position labeled X-Y disables the timed sweep, and allows you to plot the voltage applied to channel 2 vs the voltage applied to channel 1. The horizontal mode switch and the delay time controls are used only for special tricks, which we will not need. Leave the mode switch at NO DLY for no delay. The position knob works just like its vertical counterpart. The trigger system is used to start successive sweeps at corresponding points on the input waveform on each successive sweep. This operation is indicated schematically in Fig. 5-3. The Fig. 5-3. A continuous input waveform and four successive sweeps on the scope screen. The trigger is set for positive slope with the trigger level at the dashed line. PHYS 112 Laboratory Manual 27

LEVEL knob controls the voltage at which the trigger starts the sweep. The SLOPE button is used to specify whether the signal should have a positive or negative slope at the trigger voltage. The source of the triggering signal is chosen with a set of switches. You may choose to trigger off the signals applied to the vertical channels, off the power lines, or off of a signal applied to the EXT INPUT connector. Internal triggering is most common, and you may choose to use channel 1 or channel 2, independently of which one you are displaying at the time. VERT MODE triggering is odd, in that the trigger is obtained, in ALT sweep, from whichever channel is supposed to start next. This is usually confusing, and we will not use it. Triggering from the power lines is useful if you want to study something that might be synchronized with the AC power. External triggering is useful when your experiment produces a signal that occurs a fixed time before the signal of interest, since you can then see the early parts of your signal easily. The other three buttons set the sweep mode. In SGL SWP, for single sweep, the trace moves across the screen only once, and then waits until the button is pressed again. This is used only for photography. P-P AUTO, for peak-to-peak automatic is the standard mode, since it will almost always produce a usable trace. If the trace is not stable in P-P AUTO you can try NORM, for normal mode. This is useful for slowly varying signals, and for situations where the triggering is tricky, for example because of noise. The LEVEL control must be set carefully to get a trace in NORM mode, so a small light is provided to tell you when the scope has found a satisfactory trigger. If the light is on but you have no trace, something other than triggering is the problem. Other trigger modes are provided for television service work, but we will not use them. The VAR HOLDOFF control is usually left full counterclockwise. Its use will be explained when needed. The oscilloscope provides a means of measuring signals, but it is often necessary to also Fig. 5-4. The front panel of the function generator, with controls marked. PHYS 112 Laboratory Manual 28

apply a signal to a circuit as a stimulus. This is done with an instrument called a function generator, which provides signals of known frequency, waveshape and voltage. The control panel of your function generator is shown in Fig. 5-4. The instrument is turned on with the power switch, item 1 in the figure. The waveform, square, triangle or sine, is selected with the buttons labeled FUNCTION (3). The frequency range is determined by pushbuttons (2), and the exact frequency is then set using the coarse and fine FREQUENCY knobs (12, 11). The output amplitude is determined by the AMPL knob (4). Pulling gently on the AMPL knob decreases the output amplitude by a factor of 10. The knob labeled DUTY (10) changes the shape of the output wave. Leave it in the CAL position. Note that the display shows the output frequency numerically in Hz or khz, according to the indicator (14) and decimal point on the display. One last point needs to be considered before moving on to the experiments. Both the scope and the function generator are connected to the third wire of the electrical wiring system, which is ultimately connected to the earth or "ground". The main purpose of this connection is to minimize the probability of electrical shock, but it has another effect as well. Input signals to the scope, and output signals from the function generator, are always relative to the earth ground. On the scope the earth ground is connected to the terminal marked GND, while on the function generator the black terminal (not shown in Fig. 5-4) is at ground potential. As a practical matter, this means that you must pay attention to the arrangement of your circuits to avoid connecting the signal directly to ground. Proper connections will be indicated in the schematics. Note that this is not a problem with either the DMM or the low voltage power supply, since their terminals are not connected to the earth at all (in the jargon of the trade, they "float"). EXPERIMENTAL PROCEDURE Turn on the scope and allow it to warm up for a minute or so. Meanwhile, set the controls according to Table 5-1. All of the knobs and switches move easily, so if something seems stiff check that you are moving it the right way. These settings should produce two straight lines on the scope screen. Adjust the intensity for a comfortable display, and try the effect of the focus and position controls. Next, slow the sweep to 0.1 sec/div and note the effect of changing the vertical mode from ALT to CHOP. We will usually use the scope to look at rapidly changing voltages, as produced by the function generator, for example. Reset the controls to the "standard" settings. Connect the black terminal on the function generator to GND on the scope and the red terminal to CH 1. Set the function generator for about 500 Hz output with the variable amplitude knob at mid-range. There will be a signal on channel 1 but nothing on channel 2, so switch the VERTICAL MODE to CH 1 only. Try changing the various controls on the function generator and observing the changes in the output. (The scope is difficult, although probably not impossible, to damage electrically so PHYS 112 Laboratory Manual 29

INTENSITY VOLTS/DIV COUPLING VERTICAL MODE BW LIMIT CH 2 INVERT mid-range 5 (both channels) DC (both channels) BOTH, ALT in out HORIZONTAL MODE NO DLY SEC/DIV 1 ms TRIGGER P-P AUTO, INT, CH 1, LEVEL VAR HOLDOFF POSITION mid-range NORM mid-range (all three) Table 5-1. Start-up settings for oscilloscope don't worry about the effects of improper settings.) In this exercise, you are plotting many different signals on the same scales. You can also try plotting the same signal on many different scales by leaving the function generator set, and changing the VOLTS/DIV and SEC/DIV controls on the scope. Play with various combinations until you are confident of the effects of the various controls on the scope and the function generator. Turn on the scope and allow it to warm up for a minute or so. Meanwhile, set the controls according to the list above. All of the knobs and switches move easily, so if something seems stiff check that you are moving it the right way. These settings should produce two straight lines on the scope screen. Adjust the intensity for a comfortable display, and try the effect of the focus and position controls. Next, slow the sweep to 0.1 sec/div and note the effect of changing the vertical mode from ALT to CHOP. We will usually use the scope to look at rapidly changing voltages, as produced by the function generator, for example. Reset the controls to the "standard" settings. Connect the black terminal on the function generator to GND on the scope and the red terminal to CH 1. Set the function generator for about 500 Hz output with the variable amplitude knob at mid-range. There will be a signal on channel 1 but nothing on channel 2, so switch the VERTICAL MODE to CH 1 only. Try changing the various controls on the function generator and observing the changes in the output. (The scope is difficult, although probably not impossible, to damage electrically so don't worry about the effects of improper settings.) In this exercise, you are plotting many different signals on the same scales. You can also try plotting the same signal on many different scales by leaving the function generator set, and changing the VOLTS/DIV and SEC/DIV controls PHYS 112 Laboratory Manual 30

on the scope. Play with various combinations until you are confident of the effects of the various controls on the scope and the function generator. When you can reliably get a useful display, set the function generator for 1 khz sine wave output and adjust the scope so that two or three cycles roughly fill the screen. Now try adjusting the trigger LEVEL and SLOPE controls. Describe the results in your report. For practice, we will measure some characteristics of the function generator. First, you will notice that the sine wave displayed is not exactly a sine wave. Sketch the wave shape, and point out some of the small differences from a true sine wave. Switch the FUNCTION control to look at the triangle and square waves, and sketch them also, noting any deviations from the ideal. As an example of a quantitative measurement, we will determine the rise time of the square wave output. This is defined as the time required for the voltage to change from 10% to 90% of its final value, as shown in Fig. 5-5. By speeding up the sweep enough you should be able to find the 10% and 90% points and read the time between them from the calibrated scales. If the trace is too dim, increase the function generator frequency. Measure the rise time with the BW LIMIT switch both in and out. Can you explain why you get different results? Sketch the oscilloscope trace corresponding to both cases. In the x - y mode, the scope uses one of its input channels, instead of the internal time base generator, to control the horizontal deflection. We will demonstrate this feature by using two function generators to display Lissajous figures, which appear when the inputs are sine waves. The other channel provides vertical deflection, as before, so the scope plots x(t) = A x sin! x t and y(t) = A y sin! y t Connect the output of the first generator to CH 1 (x) and the second to CH 2 (y). Set both generators to produce a sine wave at a few hundred Hz and about 5 V amplitude. Set the scope Overshoot Settling Time 90% 10% Rise Time Ringing 50% Pulse 50% Width Amplitude Fig. 5-5. Definition of rise-time and other parameters for a realistic pulse or square wave. PHYS 112 Laboratory Manual 31

controls as follows: SEC/DIV : x-y CH 1 VOLTS/DIV : 1V TRIG SOURCE : INT, CH 1 CH 2 VOLTS/DIV : 1V Adjust one function generator frequency until the trace is a steady ellipse. Are! x and! y now equal? Try varying the generator frequency to observe other figures, which occur for certain relationships between! x and! y. For a more physical example, consider the circuit of Fig. 5-6. Using the square-wave output of the function generator, the capacitor charges to one polarity, then the source reverses and charges the capacitor to the opposite polarity. The whole cycle repeats at any rate we find useful. The resistor R acts as a transducer, allowing the scope to display a voltage proportional to the current through the capacitor on channel 1. Based on the general properties of RC circuits we expect the current to be large whenever the polarity changes, and to then decay exponentially to zero. Channel 2 will display the driving voltage for comparison with this expectation. Wire the circuit for measuring V R as shown in Fig. 5-6, with R = 1.5 k!. Be careful to connect the grounds as indicated. Set the function generator for a square wave at about 200 Hz. The scope will display V R on channel 1, and V S on channel 2. Set up the scope to trigger on channel 2, and then set the controls so that you can clearly see the current (V R ) and source (V S ) waveforms. You may need to adjust the frequency or amplitude of the function generator output to get a satisfactory display. Ideally, you will be able to see both the decay and the flat area that defines the zero level of current. Sketch the two waveforms, being careful to show the time relation between them. The scope is also useful for studying the behavior of circuits. The circuit shown in Fig. 5 7 is a simplified version of a power supply, a device used to convert alternating current from the power company to direct current to supply an electronic device. The crucial component is a diode, shown with an arrow and bar symbol. Diodes allow current to flow in one direction, but block reverse flow. To demonstrate this phenomenon, wire the circuit of Fig. 5-7, but omit the capacitor for now. Set the function generator for a sine wave at a hundred hertz or so. Use the scope to sketch the voltage across the resistor, being careful to mark the zero level. Are your CH 2 CH 1 red 0.047 µf R black GND Fig. 5-6. Circuit for measuring V R in an RC circuit. PHYS 112 Laboratory Manual 32

CH 2 CH 1 red 0.47 µf 1 k! black GND Fig. 5-7 Model of a power supply circuit. The diode should be one of the devices labeled rectifier diode on the circuit board. observations consistent with the idea that a diode allows current flow in only one direction? What happens if you reverse the diode in the circuit? Now connect the capacitor as shown, set the function generator to a frequency of 50-60 Hz, and sketch the new waveform. Has the addition of the capacitor changed the waveform substantially? Raise the function generator frequency to 5-6 khz and sketch the waveform again, carefully noting the zero-volt level. Can you describe the result as a small variation about a positive value? In a real power supply the resistor would be the load we wish to drive, and the capacitor would be chosen to be large enough to make the variations ( ripple ) as small as needed for the particular application. Finally, if you have time at the end, you can look at musical signals. We have adapters that will let you connect your tape deck or radio to the scope. REPORT The primary purpose of this lab is to prepare you to use a scope efficiently in the remainder of the course, and possibly later in your career. Most of your effort during the lab should go into understanding the instrument. Your report will consist of some sketches, the risetime measurements, and any other observations you care to make. PHYS 112 Laboratory Manual 33