Lightning Performance of Transmission Lines with Tall Sections

Similar documents
Lightning performance of a HV/MV substation

Improving the Performance of the Lumped Parameters transmission Line Model by Using Analog Low-Pass Filters

Parameters Affecting the Back Flashover across the Overhead Transmission Line Insulator Caused by Lightning

Analysis of lightning performance of 132KV transmission line by application of surge arresters

Analysis of MOV Surge Arrester Models by using Alternative Transient Program ATP/EMTP

Simplified Approach to Calculate the Back Flashover Voltage of Shielded H.V. Transmission Line Towers

Modeling insulation in high-voltage substations

A SIMPLIFIED LIGHTNING MODEL FOR METAL OXIDE SURGE ARRESTER. K. P. Mardira and T. K. Saha s: and

Comparison of metal oxide surge arrester models in overvoltage studies

ABSTRACTS of SESSION 6

Lightning Flashover Rate of an Overhead Transmission Line Protected by Surge Arresters

Influence Of Lightning Strike Location On The Induced Voltage On a Nearby Overhead Line

Lightning Protection of Distribution Substations by Using Metal Oxide Gapless Surge Arresters Connected in Parallel

Simulation of Lightning Transients on 110 kv overhead-cable transmission line using ATP-EMTP

Lightning overvoltage and protection of power substations

Neutral Reactor Optimization in order to Reduce Arc Extinction Time during Three-Phase Tripping

Simulation and Analysis of Lightning on 345-kV Arrester Platform Ground-Leading Line Models

Accuracy of Lightning Surge Analysis of Tower Surge Response

2000 Mathematics Subject Classification: 68Uxx/Subject Classification for Computer Science. 281, 242.2

When surge arres t ers are installed close to a power transformer, overvoltage TRANSFORMER IN GRID ABSTRACT KEYWORDS

INSTALLATION OF LSA ON A 400 KV DOUBLE-CIRCUIT LINE IN RUSSIA

Maximum Lightning Overvoltage along a Cable due to Shielding Failure

Electric Stresses on Surge Arrester Insulation under Standard and

The relationship between operating maintenance and lightning overvoltage in distribution networks based on PSCAD/EMTDC

High Voltage Induced By Transmission Lines Due To Lightning Case Study

Lightning current waves measured at short instrumented towers: The influence of sensor position

ARTICLE IN PRESS. Lightning effects in the vicinity of elevated structures. F.H. Silveira, S. Visacro

ABSTRACT 1 INTRODUCTION

New Modeling of Metal Oxide Surge Arresters

The Use of a Special Grounding Arrangement to Improve the Lightning Performance of Transmission Line

PREVENTING FLASHOVER NEAR A SUBSTATION BY INSTALLING LINE SURGE ARRESTERS

Session Four: Practical Insulation Co-ordination for Lightning Induced Overvoltages

X International Symposium on Lightning Protection

Lightning Overvoltage Performance of 110 kv Air-Insulated Substation

Lightning transient analysis in wind turbine blades

Relevant Factors to a Statistical Analysis of Overvoltages - Application to Three-Phase Reclosing of Compensated Transmission Lines

Transmission Line Transient Overvoltages (Travelling Waves on Power Systems)

MODIFICATION OF THE ARRESTER ARRANGEMENT WHEN CONVERTING THE METHOD OF NEUTRAL TREATMENT

Modeling of overhead transmission lines with line surge arresters for lightning overvoltages. Poland

SURGES TRANSFERRED TO THE LOW-VOLTAGE NETWORK VIA TRANSFORMER THE INFLUENCE OF THE LOAD CONNECTED TO THE SECONDARY

Protection Scheme for Single-Phase Fault along a Half Wavelength Transmission Trunk Using Conventional Relay

Mitigation of Back-Flashovers for 110-kV Lines at Multi-Circuit Overhead Line Towers

EVALUATION OF LIGHTNING-INDUCED VOLTAGES ON LOW-VOLTAGE DISTRIBUTION NETWORKS

EMC Philosophy applied to Design the Grounding Systems for Gas Insulation Switchgear (GIS) Indoor Substation

Lightning Current Observation on UHVAC Transmission Lines by Improved Magnetic Steel Rod Method

RESULTS OF EXPERIMENTAL HIGH CURRENT IMPULSE 4/10 s OF METAL OXIDE VARISTORS ZINC IN THE HIGH VOLTAGE 220KV SURGE ARRESTER

TRIGGERED by energy transition towards sustainability,

Cable Protection against Earth Potential Rise due to Lightning on a Nearby Tall Object

Fast Front Transients in Transformer Connected to Gas Insulated Substations: (White+Black) Box Models and TDSF Monitoring

IEEE Power Engineering Society 2001 Winter Meeting Columbus, OH. Panel Session. Data for Modeling System Transients

Computation of Lightning Impulse Backflashover Outages Rates on High Voltage Transmission Lines

Simulation of Short Circuit and Lightning Transients on 110 kv Overhead and Cable Transmission Lines Using ATP-EMTP

High-frequency Transformer Modeling for Transient Overvoltage Studies

ATP SIMULATION OF FARADAY CAGE FOR THE ANALYSIS OF LIGHTNING SURGES

Effect of High Frequency Cable Attenuation on Lightning-Induced Overvoltages at Transformers

The impact of distributed generation to the lightning protection of modern distribution lines

MARCEL A. ARAÚJO, ROGÉRIO A. FLAUZINO, OURESTE E. BATISTA, LUCAS A. MORAES

Comparison between Different InstallationLocations of Surge Arresters at Transmission Line Using EMTP-RV

Simulation of Transients with a Modal-Domain Based Transmission Line Model Considering Ground as a Dispersive Medium

Lightning current field measurement on a transmission line, comparison with electromagnetic transient calculations

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

SCIENCE & TECHNOLOGY

Effect of Shielded Distribution Cables on Lightning-Induced Overvoltages in a Distribution System

Analysis of Arrester Energy for 132kV Overhead Transmission Line due to Back Flashover and Shielding Failure

Accurate Modeling of Core-Type Distribution Transformers for Electromagnetic Transient Studies

A Study on Lightning Overvoltage Characteristics of Grounding Systems in Underground Distribution Power Cables

TECHNICAL NOTE 2.0. Overvoltages origin and magnitudes Overvoltage protection

Modeling for the Calculation of Overvoltages Stressing the Electronic Equipment of High Voltage Substations due to Lightning

Simulation Study on Transient Performance of Lightning Over-voltage of Transmission Lines

Table 1: Results with standard impluse current 8/20 s applied to check for the residual voltage of V-MOV-ZnO

Lightning Overvoltages on Low Voltage Circuit Caused by Ground Potential Rise

APPLICATION OF LONG FLASHOVER ARRESTERS FOR IMPROVEMENT OF LIGHTNING PROTECTION AND OPERATING VOLTAGE RELIABILITY OF DISTRIBUTION LINES

Investigation of Transmission Line Overvoltages and their Deduction Approach

The Effect of Lightning Parameters on Induced Voltages Caused by Nearby Lightning on Overhead Distribution Conducting Line.

Modeling of substation grounding for fast front overvoltage studies

High voltage engineering

The line-lightning performance and mitigation studies of shielded steelstructure

ACCURATE SIMULATION OF AC INTERFERENCE CAUSED BY ELECTRICAL POWER LINES: A PARAMETRIC ANALYSIS

Protection against unacceptable voltages in railway systems

Lightning Performance Improvement of 115 kv and 24 kv Circuits by External Ground in MEA s Distribution System

Substation Insulation Coordination Study

Measurements for validation of high voltage underground cable modelling

Statistical Lightning Simulations for a HV "Mixed" Overhead-Cable Line: Preliminary Studies

Sensitivity Analysis of Maximum Overvoltage on Cables with Considering Forward and Backward Waves

Prediction of Transient Transfer Functions at Cable-Transformer Interfaces

Electromagnetic Shielding Analysis of Buildings Under Power Lines Hit by Lightning

GIS Disconnector Switching Operation VFTO Study

An Approximate Formula for Estimating the Peak Value of Lightning-Induced Overvoltage Considering the Stratified Conducting Ground

Electric Power Systems Research

IMPROVEMENTS OF THE FACILITIES FOR LIGHTNING RESEARCH AT MORRO DO CACHIMBO STATION

Research on Lightning Over-voltage and Lightning Protection of 500kV. HGIS Substation

Comparison of Two Computational Programs for the Calculation of Lightning-Induced Voltages on Distribution Systems

Including Surge Arresters in the Lightning Performance Analysis of 132kV Transmission Line

7P Series - Surge Protection Device (SPD) Features 7P P P

Tab 8 Surge Arresters

ABSTRACT 1.0 INTRODUCTION LIST OF SYMBOLS

Effect of Surge Arrester on Overhead Transmission Lines as Shield against Over Voltage

POWER SYSTEM TRANSIENTS Solution Techniques for Electromagetic Transients in Power Systems -.Jean Mahseredjian

LIGHTNING OVERVOLTAGES AND THE QUALITY OF SUPPLY: A CASE STUDY OF A SUBSTATION

The Analysis Results of Lightning Overvoltages by EMTP for Lightning Protection Design of 500 kv Substation

Transcription:

Lightning Performance of Transmission Lines with Tall Sections A. J. G. Pinto, E. C. M. Costa, J. H. A. Monteiro, S. Kurokawa, J. Pissolato Abstract An analysis is proposed on the lightning performance of non-homogeneous transmission line sections composed of very-high tower structures. These line sections are 140 to 350 meter high and have been designed for transmission lines in the South America and Asia. The proposed analysis is carried out based on well-established modeling techniques for transmission lines and towers, following the standards established by the CIGRE and IEC to study lightning performance of power transmission systems. Two transmission line sections are considered: a conventional line with 40 meters high and a non-conventional line section composed of towers with more than 220 meters high (based on new transmission line sections in the Amazon region in the Northern Brazil). The lightning performance of both line sections are compared and an alternative lightning protection is proposed using metal oxide surge arresters connected directly at the towers. Keywords: transmission lines; longitudinal impedance; transversal admittance; parameter estimation; modal analysis. T I. INTRODUCTION HIS research proposes a discussion on the transient behavior of transmission lines with non-homogeneous sections composed of tower with 140 up to 350 meters high which have been installed in the South America and Asia to overcome natural and environmental barriers. In 2009, a transmission line with similar structures was proposed for the Tucuruí-Manaus connection across the Amazon forest in the Northern Brazil. The Tucuruí-Manaus line is 1850 km length and has several sections composed of towers with approximately 200 meters high (fig. 1) [1, 2]. Several line sections with tall structures have been constructed into the Amazon forest, across long rivers and floodplain areas, which represent a great challenge regarding the project itself and logistic issues. Nevertheless, several technical issues require an additional attention concerning insulation coordination, variation of the line electrical parameters, grounding and lightning surge protection. This research was supported by Fundação de Amparo à Pesquisa do Estado de São Paulo FAPESP (Procs. 13/00974-5 and 14/00197-1). E. C. M. Costa is with Universidade São Paulo, Escola Politécnica, Depto. de Engenharia de Energia e Automação Elétricas PEA, São Paulo, SP, Brazil, (corresponding author: ecmcosta@live.com). S. Kurokawa is with Univ. Estadual Paulista - Unesp, Faculdade de Engenharia de Ilha Solteira, Depto. de Engenharia Elétrica, SP, Brazil. A. J. G. Pinto and J. Pissolato are with Universidade de Campinas, Faculdade de Engenharia Elétrica, SP, Brazil. J. H. A. Monteiro is with Universidade Federal do Acre, Centro de Ciências Exatas e Tecnológicas, Rio Branco, AC, Brazil. Paper submitted to the International Conference on Power Systems Transients (IPST2015) in Cavtat, Croatia June 15-18, 2015 Fig. 1. Transmission tower with 250 meters height into the Amazon forest. The geometrical characteristics of the towers (height and distance among wires) are intrinsically related to the transversal and longitudinal parameters of the line, which could result in significant variations on the propagation characteristics of the line [3]. Another important characteristic is the lack of a corridor in order to avoid major environmental impacts. Despite several technical issues deserve a special attention; this research analyzes electromagnetic transient behavior and possible vulnerabilities in which the high line sections are subject due to possible failures in the lightning shield (grounding wires) and a possible major incidence of lightning strokes because of the height of the metallic structures. This research evaluates two 440-kV line sections by modeling using the Electromagnetic Transient Program - EMTP [4]. The first system represents a conventional transmission line with towers of approximately 40 meters high. Second line section is composed of towers with 300 meters high, based on technical descriptions provided by an international power company. The two line sections were modeled using an EMTP and based on well-established models described by the CIGRE and the IEEE [5, 6]. Simulations were carried out following the high-voltage and lightning test standards provided by the IEC [7]. Two situations were studied for each line section: with ZnO surge arresters connected directly at the towers (line surge arresters) and without the inclusion of surge arresters. Significant variations on the transient performance of the tall line section were observed and compared to the conventional line with 40-m-high towers. Even including a surge protection composed of 360-kV line surge arresters, the transient voltage peaks on the non-conventional line are much

higher than expected [8]. These results lead to several questions on the reliability of these non-conventional transmission lines, if the tower models available in the technical literature are also suitable to model transmission towers with more than 140 meters high and if a conventional surge protection apparatus (with 360-kV line surge arresters) is also suitable for a 440-kV transmission line supported by tall towers. The objective of this paper is to promote a comprehensive technical discussion on the variations observed in the electrical performance of the tall transmission section, aiming a better understanding of these variations (compared to the conventional 440-kV transmission line) as well as development of alternative surge protection methods and suitable computational models for this emergent power transmission technology. available in the EMTP. It is well-known that an atmospheric impulse is composed of a wide range of frequencies; hence the line modeling should take into account the frequency dependence of the line parameters for the range of frequencies which an atmospheric impulse is composed. Thus, the range considered in the line modeling is up to 1 MHz. The frequency-dependent line parameters are calculated considering an ideal soil resistivity of 1000 Ω.m [8]. The geometrical characteristics of the transmission line sections are indicated in fig. 3 and given in the table 1. II. METHODOLOGY The proposed analyses are based on the accurate modeling of the transmission line sections, towers, atmospheric impulse and line surge arresters. These elements are modeled based on well-established methods available in the technical bibliography [3, 5, 6, 7]. From this methodology, the surge voltage is simulated on the transmission tower where the atmospheric impulse occurs, with and without the presence of line surge arresters connected at the towers in parallel with the insulator chains. Figure 2a shows an asymmetrical transmission line equipped with line surge arresters, highlighted by red circumferences, and in fig. 2b a line surge is shown. Fig. 3. Geometrical representation of the transmission line and tower. TABLE I GEOMETRICAL CHARACTERISTICS OF THE LINE SECTIONS Conventional Non-conventional y 1 27.64 m 280 m y 3 24.04 m 255 m x 23 18.54 m 24.0 m y PR 36.0 m 300 m x PR 15.02 m 12.0 m (a) Fig. 2. Line surge arresters installed in a conventional asymmetrical tower (a) and a line ZnO surge arrester described in details (b). In fig. 2a, the line surge arresters are connected in parallel with the line insulators. The superior terminal is connected to the phase whereas the inferior terminal is wired to the metallic structure of the tower. Figure 2b shows in details a line surge arrester with an anti-corona ring at the superior terminal. A. Transmission line modeling (b) The conventional and non-conventional line sections are modeled using a frequency-dependent transmission line model The bundled conductors of both line sections have a similar structure. They are composed of four Grosbeak conductors spaced 0.4 m from each other. The shield wires are EHWS-3/8 and implicitly included in the line modeling [9]. Another important technical description is the distance between two consecutive towers, which is 500 m for the conventional representation and 2 km for the line sections using the tall towers (non-conventional) [8]. The frequency-domain behavior of the electrical parameters of the non-conventional line section, described in table I, are analyzed as a function of the soil resistivity in reference [3] and [8]. B. Transmission line modeling In computational models to study lightning performance of transmission lines, the shield wires should be included as well as towers and eventual nonlinear corona effect. Furthermore, the necessary computational model should differ in comparison with models applied for evaluation of

electromagnetic transient resulted from switching operations in the systems [10]-[12]. The proposed phases and shield wires are modeled as frequency-dependent line sections using the mentioned computational line model. On the other hand, the metallic structure of the towers is modeled by horizontal and transversal transmission line sections, as described in reference [5]. The horizontal sections of the towers are modeled as horizontal transmission line where the parameters are obtained from standard line formulas. The vertical sections are also calculated using a specific formulation derived from the standard line formulas. The mutual coupling between any two parallel vertical transmission line sections is also taken into account [5]. The transmission tower in fig. 3 is represented using transmission line segments as follows in fig. 4. Fig. 4. Transmission tower modeled by line segments. Based on the proposed tower modeling, the electromagnetic transient of each section can be expressed by the well-known Transmission Line Telegrapher's Equations [12]: v( x, t) i( x, t) R( x) i( x, t) L( x) x t (1) i( x, t) v( x, t) Cx ( ) x t (2) The terms L(x), R(x) and C(x) are per unit-length inductance, resistance and capacitance, respectively. The equations (1) and (2) do not take into account the frequency variations of the line parameters. However, since the skin depth is very small at high frequencies, the approach presented in [12] provides accurate results for fast and impulsive transients. Equations (1) and (2) were originally obtained for an infinite long line which means that end effects are neglected. Thus, for the case of the shortest truss segments this may not hold. Nevertheless, for the travel and the rise times of the waveforms involved in lightning, tower arms behave as long wires antennas. In this case, reflection analysis can be performed considering only the transmission line behavior [6]. In reference [12], an interesting analysis is presented comparing the modeling of tall towers using transmission line and antenna theories. The same reference assumes that the principal propagation mode is transverse electromagnetic (TEM) and the voltage difference can be obtained between any pair of points in the same transversal plane. Although the TEM representation is an approximation, it provides a practical method using the well-established transmission line theory to model transmission towers. Furthermore, the frequency- and time-domains analyses prior discussed in reference [12], in which tower modeling using line and antenna theories were compared, proves that the transmission line representation is accurate enough to model towers to study impulses with time to maximum up to 1 µs (typical of subsequent return strokes). Thus, assuming an atmospheric impulse with a front-wave time of 2.6 µs, the tall tower modeling using transmission line theory shows to be physically consistent. C. Atmospheric impulse The atmospheric impulse is modeled as a double exponential current wave, characterized by a front time of 2.6 µs and a tail time of 65 µs. Usually, in agreement with the International Electrotechnical Commission (IEC), a normalized atmospheric impulse is represented by a 8/20 µs current wave [7]. However, a front-wave rise of 20 ka/µs (di/dt) given by a 2.6/65 µs current wave has been widely used to simulate atmospheric surges on transmission towers [3]. Furthermore, this wave shape represents a more conservative situation because of the steeper front time, greater front-wave rise and a longer tail time if compared to the IEC-normalized atmospheric impulse [7]. The current source representing the atmospheric impulse is applied at the top of a tower in the middle of the line length. The transient voltage is measured on this same tower. D. Surge arrester modeling The first step to model surge arresters for a power transmission system is to calculate the nominal voltage of the arresters. This technical characteristic is obtained as a function of the maximum system voltage and based on the temporary overvoltage (TOV) capability at 60 Hz for 1 and 10 seconds. For both 440-kV systems compared in this research, the maximum operation voltage is 462 kv and the TOV capabilities for 1 and 10 seconds are 1.4 p.u. and 1.25 p.u., respectively [13]. Based on these technical characteristics and according with the information available in a given manufacturer database, 360-kV ZnO surge arresters are usually installed for nominal 440-kV systems with the given maximum voltage operation and TOV. The tower surge arresters used for the conventional and the non-conventional lines are the same, since the nominal voltages of both systems are the same. The line surge arresters are modeled in the time domain following the well-established IEEE reference model (fig. 5), which is approached in several researches and technical references in power system lightning protection [2, 9, 10].

Fig. 5. IEEE reference model for metal-oxide surge arresters. The value of the elements L 0, R 0, L 1, R 1 and C are calculated based on the number of varistor columns and the physical height of the surge arrester. The magnitude of the residual voltage from an atmospheric impulse (20 ka 8/20 µs current wave) and from a switching operation (2 ka 30/80 µs current wave) are necessary to calculate the nonlinear resistances A 0 and A 1. The residual voltages of the 360-kV surge arrester used in the current analysis are 856 kv for atmospheric impulse and 712 kv for switching operation. The L, R and C elements of the electric circuit in fig. 3 are obtained based on the database provided by the manufacturer. More details on modeling of surge arresters are given step-by-step in reference [6]. The voltage profiles described in fig. 6 show an adequate performance for a conventional 440-kV transmission system equipped with 360-kV line surge arresters connected directly at the towers. Curve 2 shows that the voltage surge is maintained far below the maximum operation voltage of 462 kv. Otherwise, without the protection apparatus using line surge arresters, the voltage peak is approximately 700 kv (curve 1). The same simulation is carried out considering the geometrical and physical characteristics of the transmission line section composed of towers with 300 meters high, as described in table I. A 2.6/65 µs current wave is applied at the top of the metallic structure of a tower located at the middle of an infinite line section. The transient voltages on the tall tower, with and without the insertion of line surge arresters, are shown in fig. 7. III. ELECTROMAGNETIC TRANSIENTS AND SIMULATIONS A conventional and a non-conventional infinite line segment are considered according with the given descriptions of the line, towers, wires and distance of two consecutive towers. The surge impedance of the towers and the current surge representing an atmospheric impulse are also previously described. Based on these technical descriptions, the timedomain simulations are carried out from an atmospheric impulse applied on a steel tower located at the middle of the line segments. A critical and more conservative situation is simulated, considering a total failure in the insulation coordination of the power transmission system (backflashover). The transient overvoltages on the tower struck by the atmospheric impulse are evaluated for the two line sections, with and without the presence of line surge arresters. Figure 6 shows the transient voltages on the conventional tower struck by the atmospheric impulse, without (curve 1) and with line surge arresters at the three phases (curve 2). Fig. 6. Transient voltages on the conventional tower without surge arresters (1) and with line surge arresters (2). Fig. 7. Transient voltages on the non-conventional tower without surge arresters (1) and with line surge arresters (2). For the non-conventional line section in fig. 7, the voltage peak without line surge arresters is more than 1500 kv (curve 1), two times higher than the voltage peak observed in the conventional system in fig. 5. Curve 2 shows that the 360-kV ZnO arresters are not able to maintain the system voltage below the maximum operational voltage of 462 kv, taking into account that both transmission lines are characterized by the same nominal voltage. IV. DISCUSSION AND CONCLUSIONS The two line sections compared in this research are based on existing systems or transmission lines under construction, as discussed in this paper and other technical literatures. Both systems have the same operational voltage of 440 kv and different geometrical and physical characteristics. However, the lightning performance and the transient behavior of the two line sections showed significant differences. Possible causes and technical characteristics can be listed as follows: i. Previous researches have described variations in the transversal and longitudinal parameters of the conventional and non-conventional line sections evaluated in this research. Most of these variations were observed at high frequencies which mean a direct influence on the lightning performance observed for the non-conventional system. ii. The distance of two consecutive towers of the nonconventional line section is approximately four times longer than the same distance for the conventional line. This characteristic results in a minor flow of shunt current

through the towers to the ground along the line. Each tower is grounded at the base, thus the surge current has a better surge current flow to the ground with a greater number of towers per length. The quantity of tower per length in the conventional line is greater than for the nonconventional one, consequently the conventional line section has a better flow of the surge current through the tower to the ground. By contrast, the line sections with tower higher than 200 meters have a minor number of tower per length which represents less flow of the surge current wave to the ground and thus greater surge voltage values at the tall towers. iii. Variations on the surge inductances of the conventional and non-conventional towers could result the major transient voltage observed on the 300-m-high tower. iv. The proposed tower modeling by line segments could not be suitable for the non-conventional towers because of the high height. The tower modeling using line segments is suitable for conventional towers because they can be represented by a set of short line segments, as discussed in the paper. Otherwise, the tall towers are modeled by several short and also long segments, which could not represent an accurate approach for the non-conventional towers. v. An evaluation is necessary on the discharge channel of the atmospheric impulse. The significant difference in the line height of conventional and non-conventional towers may result variations on the magnitude and wave shape of the atmospheric impulse, resulting variations in the transient behavior of the towers. V. REFERENCES [1] G. N. D. Boile and R. L. Nascimento. "Linhão Tucuruí - 1800 km de integração regional", Revista T & D Amazônia, vol. 8, n. 18, pp.58-62, 2010 (Portuguese). [2] W. M. Frota. "Melhorias estruturais de suprimento para os sistemas elétricos isolados de Manaus e Macapá, Revista T & D Amazônia, vol. 3, n. 6, pp.23-29, 2005 (Portuguese). [3] A. J. G. Pinto, E. C. M. Costa, S. Kurokawa, J. H. A. Monteiro, J. L. Franco, J. Pissolato. Analysis of the electrical characteristics and surge protection of EHV transmission lines supported by tall towers, Int. Journal of Electrical Power & Energy Systems, vol. 57, pp. 358-365, 2014. [4] H. W. Dommel. EMTP theory book. University of British Columbia: Vancouver, 1986. [5] Cigré Working Group 01 (Lightning) of Study Committee 33 (Overvoltages and insulation coordination): Guide to procedures for estimating the lightning performance of transmission lines, 1991 [6] C. A. Christodoulou, L. Ekonomou, G. P. Fotis, P. Karampelas, I. A. Stathopulos. "Parameters' optimisation for surge arrester circuit models". IET Science, Meas. & Technol., vol. 4, n. 2, pp. 86-92, 2010 [7] IEC 60060-1. High-voltage test techniques - Part 1: general definitions and test requirements, 2nd ed., 2009-2010 [8] S. Kurokawa, E. C. M Costa, A. J. G. Pinto, J. Pissolato. Analysis of electric characteristics of high-elevation stretches of the Tucuruí- Macapá-Manaus connection, Journal of Control, Automation and Electrical Systems, vol. 24, pp. 714-724, 2013 [9] S. Kurokawa, J. Pissolato, M. C. Tavares, C. M. Portela. Behavior of overhead transmission line parameters on the presence of ground wires, IEEE Trans. Power Delivery, vol. 20, n. 2, pp. 1669-1676, 2005. [10] W. A. Chisholm, Y. L. Chow, K. D. Srivastava. "Lightning surge response of transmission towers". IEEE Trans. on Power App. and Systems, vol. 102, n. 9, pp. 3232-3242, 1983. [11] J. A. Gutiérrez, P. Moreno, J. L. Naredo, J. L. Bermúdez, C. A. Nucci, F. Rachidi. "Nonuniform transmission tower model for lightning transient studies". IEEE Trans. on Power Delivery, vol. 19, n. 2, pp. 490-496, 2004. [12] L. Grcev, F. Rachidi. "On tower impedances for transient analysis". IEEE Trans. on Power Delivery, vol. 19, n. 3, pp. 1238-1244, 2004. [13] IEC 60099-4. Surge arresters - Part 4: metal-oxide surge arresters without gaps for a.c. systems, 2nd ed., 2004-2005.