OM 16. Onsite micro-ohmmeter up to 10 A

Similar documents
CP 6632 Handheld process signal calibrator

CALYS 50. Field multifunction calibrator for basic use

CALYS 100. Field precision documenting multifunction calibrator

CALYS 75. Field documenting multifunction calibrator

CALYS 150. Advanced documenting multifunction calibrator thermometer

CALYS Transportable documenting multifunction calibrator with high accuracy 0.01%

CALYS 150. Advanced documenting multifunction calibrator thermometer

FRONTDAQ 20. High speed acquisition module with universal synchronized inputs and embedded webserver software

FD 5 / 10 / 15. Fast acquisition module with universal synchronized inputs and embedded webserver software

on-site tester calibrator CALYS 5

ISOPALM 200. Cable fault locator

CALYS 150. Advanced documenting multifunction calibrator thermometer

DC Resistance Meters 2840 Series

1. OVERVIEW 2. DESCRIPTION 3. RAPID SET-UP GUIDE 4. OPERATION 5. MAINTENANCE 6. SPECIFICATIONS

High-precision portable RESISTANCE METER

3541 RESISTANCE HiTESTER

Hand-held temperature calibrator Model CEP3000

On-site multifunction calibrator

Winding Ohmmeter & Tap Changer Test Set RMO10TW

MIT415 Insulation tester

MIT400 CAT IV Industrial Insulation Testers

MIT400 CAT IV Industrial Insulation Testers

Tap Changer Analyzer & Winding Ohmmeter RMO-TT

Winding Ohmmeter RMO-TW

MIT400 CAT IV Industrial Insulation Testers

RMO-A series Micro Ohmmeters

Winding Ohmmeter RMO-TW

Tap Changer Analyzer & Winding Ohmmeter RMO-TT

Tap Changer Analyzer & Winding Ohmmeter RMO60TT

MIT400/2. CAT IV Insulation testers MIT430/2: CAT IV Insulation testers

high accuracy tester-calibrator PJ 6301

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Battery Analyzers BA6010 Series

Top-Innovator MotorAnalyzer 1. Multi-purpose testers for electric motors and windings. Made in Germany Expect more.

Motor Winding Ohmmeter RMO50M

Tap Changer Analyzer & Winding Ohmmeter RMO-TD Series

Contents. Measurement and checking equipment for transformation centers Micro-ohmmeter MH-10 Page 3. Indirect earth contact simulator TL-5 Page 5

INDEX. Micro-ohmmeter MH-10 Page 3. MI (5, 10, 15, 20 kv) Page 4 Mega-ohmmeter MD (5 kv) Page 4

em4 local - Robust Specific characteristics Part number

MIT400/2 CAT IV Insulation testers

CALYS channels High accuracy calibrator

2304 EN. High-Precision Automatic Inspection and Test Unit for Electrical Resistance Testing RESISTOMAT. Automatic inspection and test unit

High Speed Milliohm Resistance Meter

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

BENNING. CM7 Electrical Tester. Service Information

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

METRATESTER 5+ Tester for DIN VDE /6.15

High Performance Process & Temperature Controllers

High-precision process calibrator Model CED7000

MODEL MCHQ250V12B MCHQ250V24B MCHQ250V54B

Fluke 355 and 353 True-rms 2000 A Clamp Meters Versatile and rugged tools for applications with high currents

Three-Phase Winding Ohmmeter TWA25K

Excellent low-cost Process & Temperature Controllers

SDM3045X Digital Multimeter. DataSheet

RESISTANCE HiTESTER 3541

1587/1577 Insulation Multimeters

HT COMBI419. Innovative meter designed to perform all safety test

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Fluke Fluke-Direct.ca. Three-Phase Power Logger. Technical Data

Top-Innovator MotorAnalyzer 2. Multi-purpose testers for electric motors and windings. Made in Germany Expect more.

DM-III MULTITEST Power Quality Recorder

MIT400 Series CAT IV Insulation Resistance and Continuity Testers

TWA Series Three-Phase Winding Ohmmeters & Tap Changer & Winding Analyzers

Primary-standard resistance thermometry bridge Model CTR9000

Chapter 6 Specifications

MCHQ80VxB series ELECTRICAL SPECIFICATION. 80W LED Switching Power Supply (CV+CC) with 3 in 1 dimming function OUTPUT INPUT

Cooling Fans G-17. Cooling Fans G-17. AC Input/Low-Power Consumption EMU Series. AC Input/Compact Size MU Series

TORKEL 900-series Battery Load Unit

Fluke and

Micro-Ohmmeter Model UM200

DATA SHEET A Multimeter 5.5 Digit Dual Display, Benchtop DMM

DM-45 Digital Multimeter

MIT400 CAT IV Industrial Insulation Testers

Miniature resistance thermometer Model TR33, thread-mounted

Model 1140A Thermocouple Simulator-Calibrator

Room Sensors. for relative humidity and temperature

Room Sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range

SCOPE TRM 25 TRM 25+ Transformer Winding Resistance Meter. The most advanced Transformer Winding Resistance Meter injects up to 25A DC...

Hygro-ThermoTransmitter-compact xxx

02/11/2015

02/11/2015

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

INPUT RESISTANCE OR CLAMP VOLTAGE. 2 Years 23 C ±5 Voltage mv 3 10 nv > 10 G

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

Product Information ECI 1319S EQI 1331S. Absolute Rotary Encoders without Integral Bearing and with DRIVE-CLiQ Interface.

Appendix A: Specifications

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Control module 2 circuits AD290. Installation and Service Manual

Fluke 3540 FC Three-Phase Power Monitor

Lexium integrated drives

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

HP 34401A Specifications 8

SDM3045X Digital Multimeter. DataSheet

Fluke 1623 and GEO Earth Ground Testers. Technical Data. Stakeless testing

Network Analyzer for Low-, Medium- and High-Voltage Networks

Tap Changer Analyzer & Winding Ohmmeter RMO25TD

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

TORKEL 900-series Battery Load Unit

Transcription:

Accuracy: 0.05% Resolution: 0.1 µω Ranges: Selectable from 5 mω up to 2.5 KΩ Auto power-off of current Continuous measurement current for inductive loads Pulse measurement current for non-selfic résistances Automatic compensation of thermal E.M.F. Temperature compensation OM 16 Onsite micro-ohmmeter up to 10 A Designed for field use, OM 16 onsite micro-ohmmeter performs 4-wire measurements of inductive and non-inductive resistances with continuous, pulse or AC measuring current up to 10 A.

Description Designed for field use as well indoor as outdoor, OM 16 onsite micro-ohmmeter performs 4-wire measurements of inductive and non-inductive resistances with continuous, pulse or AC measuring current up to 10 A. Offering a high accuracy of 0.05 % and resolution of 0.1 µω, it works over a large selectable range of resistances from 5 mω up to 2.5 KΩ. All parameters are user-programmable, either directly through the instrument interface or via Log OM software delivered in option: measuring current, range, unit, alarmes, automatic average function, absolute autozero. Before every measurement, EMFs are measured and automatically removed for a greater accuracy of measurements. For non-inductive resistances, a single operator is enough to perform the measurement since it will be automatically triggered once continuity is established between the two points. The user can also set the metal nature or its temperature coefficient, the reference temperature and the ambient temperature. The ambient temperature might be also measured by an external temperature probe. 2 alarm thresholds are programmable and either notified by a signal displayed on the screen, a light or a loud beeper. The large interactive display of OM 16 informs in real time the operator about the type of measurement, range, calculation conditions and threshold values. Battery-powered, OM16 has a high storage capacity of 1,000 measurements to be read directly on the display or via Log OM software or printer available in option. Protection up to 250 V is ensured at every measurement terminal, while any overrange, open circuit or empty battery signal detected is notified by LEDs and messages displayed. Easy-to-use, rugged and protected agains rough environment (IP 53 when opened, IP 64 when closed), OM 16 is widely used indoors and outdoors in many industries: Aerospace Energy field Domestic electrical appliances Cable manufacturing Telecommunication Electronics Automotive industry Railway Key features: Test current: 1 ma to 10 A 4-wire measurement Auto power-off of current Continuous measurement current for inductive loads: Coils, transformers, motor windings, twisted cables Pulse measurement current for non-selfic resistances: Earth bonding, ground 50-52 Avenue Paul Langevin, F-91130 Ris Orangis - Tél. : 01 69 02 88 88 - Fax : 01 69 02 04 38 2

continuity, contact resistances, non-twisted cables Automatic compensation of thermal E.M.F. Temperature compensation Metal temperature compensation 50-52 Avenue Paul Langevin, F-91130 Ris Orangis - Tél. : 01 69 02 88 88 - Fax : 01 69 02 04 38 3

Specifications Resistance measurement Measurement range Resolution Accuracy (1 year) (23 C ±5 C) Measuring current Voltage drop 5 mω 0.1 μω 0.05 % + 0.5 μω 10 A 50 mv 25 mω 1 μω 0.05 % + 3 μω 10 A 250 mv 250 mω 10 μω 0.05 % + 30 μω 10 A 2.5 V 2500 mω 0.1 mω 0.05 % + 0.3 mω 1 A 2.5 V 25 Ω 1 mω 0.05 % + 3 mω 100 ma 2.5 V 250 Ω 10 mω 0.05 % + 30 mω 10 ma 2.5 V 2500 Ω 100 mω 0.05 % + 300 mω 1 ma 2.5 V Automatic or manual selection of measurement range Accuracy given in % of reading + fixed value at 23 C ± 5 C Possible excess over the normal rating: 5 mω range: + 20 % 25 mω range: + 20 % Maximum voltage between the terminals in an open circuit: 7V. Further features Resistance types Measurement current Measurement trigger conditions EMFs Temperature compensation Temperature compensation for measurements at Tref Inductive resistances: Coils, transformers, motor windings... Non-inductive resistances: Earth bonding, coating, contact resistances... DC current from 1 ma to 10 A Continuous ou pulsed Manual or automatic trigger allowing a single operator to be able to perform measurements Automatic compensation of EMF parasites before each measurement for a greater accuracy Choice of metal temperature coefficient Choice of reference temperature and ambient temperature (programmed or measured with integrated sensor) Saisie ou mesurée par Pt100 interne ou externe reliée à l instrument Résolution : 0,1 C 50-52 Avenue Paul Langevin, F-91130 Ris Orangis - Tél. : 01 69 02 88 88 - Fax : 01 69 02 04 38 4

Précision : ± 0,5 C (Tref = Température de reference programmée, à laquelle la mesure est ramenée) Temperature coefficient beyond operating range Alarms Calibration <10% accuracy/ C (from 0 to18 C and from 28 to 50 C) 2 programmable thresholds with visuel and sound signal Digital calibration without internal adjustment General specifications Size Weight Supply Batteries (option) 270 x 250 x 180 mm 4 kg 92 to 256 V (45 to 400 Hz) Type: Ni/Mh 8.5 Ah Charging time: 5 h Battery life: 5,000 measurements at 10 A Communication ports RS 232 Storage capacity 1,000 measurements identified by numbers Memory reading directly on the display, via software or printer Environmental specifications Reference range Operating reference range Limit operating range Storage temperature limits Indice de protection 23 C ± 5 C (45 to 75 % w/o condensing) 0 to 50 C (RH: 20 to 75 % w/o condensing) -10 C to +55 C (RH: 10 to 80 % w/o condensing) -40 C to +60 C IP53 according to EN60529 Safety specifications Protections Electronic protection up to 250 V for voltage wires Fuse protection for current wires Protection against current circuit breaking during inductive resistance measurements Class In accordance with EN 61010-1 Category II, pollution 2 50-52 Avenue Paul Langevin, F-91130 Ris Orangis - Tél. : 01 69 02 88 88 - Fax : 01 69 02 04 38 5

Rated voltage Chocks and vibrations EMC conformity 60 V EN61010-1 Immunity EN 61000-4-2 EN 61000-4-3 EN 61000-4-5 EN 61000-4-6 EN 61000-4-11 EN 61000-4-4 Conducted and radiated emissions: EN 55022, class B EN 61000-3-2 EN 61000-3-3 50-52 Avenue Paul Langevin, F-91130 Ris Orangis - Tél. : 01 69 02 88 88 - Fax : 01 69 02 04 38 6

Models and accessories Instrument: OM16 On-site micro-ohmmeter Clips and probes: Please note that 2 clips are needed per OM 16. AMT005 Long handspike, per unit Needle diameter: 3 mm, length without handle: 83 mm, total length: 215 mm Cable length: 5 m AMT006 Large kelvin clip, per unit Opening diameter: 25 mm, cable length: 5 m AMT013 Triggered handspike, per unit Needle diameter: 3 mm, length without handle 83 mm, total length: 215 mm Cable length: 5 m Triggering cable to be connected by RS 232 to OM 16 AMT011 Small handspike, per unit Needle diameter: 3 mm, total length: 125 mm Cable length: 5 m AMT012 Small kelvin clip, per unit Opening diameter: 12 mm, cable length: 5 m AMT008 AMT014 AMT015 Extension lead, length: 20 m External temperature sensor Extension cable for AMT014, length: 2 m Other accessories: LOG OM Configuration & exploitation software for OM 16 Including RS 232 cable PX 58 CX 85 Printer with batteries, paper width: 58 mm Printer with mains supply, paper width: 85 mm 50-52 Avenue Paul Langevin, F-91130 Ris Orangis - Tél. : 01 69 02 88 88 - Fax : 01 69 02 04 38 7

Powered by TCPDF (www.tcpdf.org) OM 16 Certification: QMA11EN COFRAC certificate of calibration Packing information: Shipping size Weight 320 x 300 x 220 mm 5 Kg 50-52 Avenue Paul Langevin, F-91130 Ris Orangis - Tél. : 01 69 02 88 88 - Fax : 01 69 02 04 38 8