*Corresponding author.

Similar documents
Jian-Wei Liu, Jing Zheng, Jin-Long Wang, Jie Xu, Hui-Hui Li, Shu-Hong Yu*

Directional Growth of Ultra-long CsPbBr 3 Perovskite. Nanowires for High Performance Photodetectors

Supplementary Information for

Synthesis of Silver Nanowires with Reduced Diameters Using Benzoin-Derived Radicals to Make Transparent Conductors with High Transparency and Low Haze

Supplementary Materials for

Chemistry 524--"Hour Exam"--Keiderling Mar. 19, pm SES

Electrical and Optical Tunability in All-Inorganic Halide. Perovskite Alloy Nanowires

High Performance Thin Film Optical Coatings Technical Reference Document 09/13. Coatings Capabilities. Heat Control - Hot Mirror Filters

Development and Applications of a Sample Compartment FTIR Microscope

Electronic Supplementary Information

Characterisation of Photovoltaic Materials and Cells

z t h l g 2009 John Wiley & Sons, Inc. Published 2009 by John Wiley & Sons, Inc.

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Supplementary Materials for

Structural, optical, and electrical properties of phasecontrolled cesium lead iodide nanowires

Supporting Information. Epitaxially Aligned Cuprous Oxide Nanowires for All-Oxide, Single-Wire Solar Cells

Ultrafast Surface-Enhanced Raman Probing of the Role of Hot Electrons in Plasmon-Driven Chemistry. Supporting Information

High Power and Energy Femtosecond Lasers

Appreciating the very little things: Status and future prospects of TEM at NUANCE

Femtosecond to millisecond transient absorption spectroscopy: two lasers one experiment

PGx11 series. Transform Limited Broadly Tunable Picosecond OPA APPLICATIONS. Available models

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Electrical Engineering and Computer Science

Indiana University JEM-3200FS

Nanotechnology in Consumer Products

Integrated into Nanowire Waveguides

Introduction of New Products

Characterisation of Photovoltaic Materials and Cells

SUPPLEMENTARY INFORMATION

Quantum Dots. a) To whom correspondence should be addressed. E mail:

Visibility of Detail

Femtosecond laser microfabrication in. Prof. Dr. Cleber R. Mendonca

AP Chemistry Cell Phone Spectroscopy Lab Adopted from Alexander Scheeline Department of Chemistry University of Illinois at Urbana-Champaign

plasmonic nanoblock pair

High-Power Femtosecond Lasers

Fast Raman Spectral Imaging Using Chirped Femtosecond Lasers

Department of Chemistry, Wuhan University, Wuhan , China

SUPPLEMENTARY INFORMATION

GaAs polytype quantum dots

Chemical Imaging. Whiskbroom Imaging. Staring Imaging. Pushbroom Imaging. Whiskbroom. Staring. Pushbroom

S200 Course LECTURE 1 TEM

Beams and Scanning Probe Microscopy

Progress in ultrafast Cr:ZnSe Lasers. Evgueni Slobodtchikov, Peter Moulton

Supplementary Figure S1 X-ray diffraction pattern of the Ag nanowires shown in Fig. 1a dispersed in their original solution. The wavelength of the

Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region

High Energy Non - Collinear OPA

QUANTUM DOT SENSITIZED ZNO NANOWIRE-P3HT HYBRID PHOTOVOLTAICS NICHOLAS ANDREW HARRIS PATRICK KUNG, COMMITTEE CHAIR SEONGSIN KIM DAVID NIKLES A THESIS

Scanning electron microscope

High-Resolution Bubble Printing of Quantum Dots

Experimental Physics. Experiment C & D: Pulsed Laser & Dye Laser. Course: FY12. Project: The Pulsed Laser. Done by: Wael Al-Assadi & Irvin Mangwiza

Supporting Information. Single-Nanowire Electrochemical Probe Detection for Internally Optimized Mechanism of

Solar Cells, Modules, Arrays, and Characterization

Chapter 1. Basic Electron Optics (Lecture 2)

Low Voltage Electron Microscope

Ppm detection of alcohol vapors via metal organic framework functionalized surface plasmon resonance sensors

The equipment used share any common features regardless of the! being measured. Electronic detection was not always available.

Spotlight 150 and 200 FT-IR Microscopy Systems

SUPPORTING INFORMATION

Supplementary Information. Phase-selective cation-exchange chemistry in sulfide nanowire systems

Supplementary Information

Add CLUE to your SEM. High-efficiency CL signal-collection. Designed for your SEM and application. Maintains original SEM functionality

Chemistry Instrumental Analysis Lecture 10. Chem 4631

Material analysis by infrared mapping: A case study using a multilayer

combustion diagnostics

Measuring Kinetics of Luminescence with TDS 744 oscilloscope

ABSTRACT 1. INTRODUCTION

Lecture 19 Optical Characterization 1

Magnesium and Magnesium-Silicide coated Silicon Nanowire composite Anodes for. Lithium-ion Batteries

Quantifying the energy of Terahertz fields using Electro-Optical Sampling. Tom George. LCLS, Science Undergraduate Laboratory Internship Program

Infrared wire grid polarizers: metrology, modeling, and laser damage threshold

Spectral phase shaping for high resolution CARS spectroscopy around 3000 cm 1

Explain what is meant by a photon and state one of its main properties [2]

Fingerprinting the oxidation state of U(IV) by

Nd:YSO resonator array Transmission spectrum (a. u.) Supplementary Figure 1. An array of nano-beam resonators fabricated in Nd:YSO.

Supporting Information

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

Absentee layer. A layer of dielectric material, transparent in the transmission region of

Supporting Information. Absorption of Light in a Single-Nanowire Silicon Solar

Scanning electron microscope

Human Retina. Sharp Spot: Fovea Blind Spot: Optic Nerve

Lecture 04: Solar Imaging Instruments

On-line spectrometer for FEL radiation at

Spectrophotometer. An instrument used to make absorbance, transmittance or emission measurements is known as a spectrophotometer :

Nano-structured superconducting single-photon detector

FTIR microscopy and imaging for failure analysis in electronics manufacturing

Thermochromic Solid-State Emission of Dipyridyl Sulfoxide Cu(I) Complexes

Nanoscale Systems for Opto-Electronics

Observational Astronomy

R. J. Jones Optical Sciences OPTI 511L Fall 2017

taccor Optional features Overview Turn-key GHz femtosecond laser

Visible light emission and metal-semiconductor transition in single walled carbon nanotube composites T. Pradeep Department of Chemistry and

Lecture 18: Photodetectors

Observing Microorganisms through a Microscope LIGHT MICROSCOPY: This type of microscope uses visible light to observe specimens. Compound Light Micros

Multi-Wavelength, µm Tunable, Tandem OPO

Joliot Type Spectrometer. photosynthesis system JTS-10. A LED pump-probe spectrometer

Horiba LabRAM ARAMIS Raman Spectrometer Revision /28/2016 Page 1 of 11. Horiba Jobin-Yvon LabRAM Aramis - Raman Spectrometer

Presented by Jerry Hubbell Lake of the Woods Observatory (MPC I24) President, Rappahannock Astronomy Club

Instructions for the Experiment

Simultaneous measurement of two different-color ultrashort pulses on a single shot

Terahertz spectroscopy measurements

M. N. Trainer and P. J. Freud. Application Note. SL-AN-05 Revision D. Provided By: Microtrac, Inc. Particle Size Measuring Instrumentation

Transcription:

Supporting Information for: Ligand-Free, Quantum-Confined Cs 2 SnI 6 Perovskite Nanocrystals Dmitriy S. Dolzhnikov, Chen Wang, Yadong Xu, Mercouri G. Kanatzidis, and Emily A. Weiss * Department of Chemistry, Northwestern University, 2145 Sheridan Rd., Evanston, IL 60208-3113 Argonne-Northwestern Solar Energy Research Center, 2145 Sheridan Rd., M490, Evanston, IL 60208 *Corresponding author. e-mail: e-weiss@northwestern.edu METHODS Diffuse Reflectance Measurements. Optical diffuse reflectance measurements were performed on films of Cs2SnI6 NCs drop-casted on glass substrates at room temperature using a Shimadzu UV-3600 PC spectrometer operating in the 200 2500 nm region. The reflectance versus wavelength data were used to estimate the band gap of the material by converting reflectance to absorption data using the Kubelka Munk equation: α/s = (1-R) 2 /2R, where R is the reflectance and α and S are the absorption and scattering coefficients, respectively. Transient Absorption Spectroscopy. Details of the TA setup are reported in previous work. 1 Briefly, TA measurements were carried out with a commercial system (Ultrafast Systems LLC, Helios) powered by an 800 nm, 2.5 mj, 100 pulse train generated from a Ti:sapphire amplifier (Spectra-Physics, Solstice). The 800 nm beam was split into pump and probe arms. The pump beam was directed through an optical parametric amplifier (Light Conversion, TOPAS-C) with sum-frequency generation kit to produce pump pulses at wavelengths of 470 nm. A small portion of the amplifier output was directed through a 3 mm sapphire window to generate the white light continuum probe in the visible. The residual 800 nm fundamental in the probe arm was blocked with two KG3 color glass filter (Thorlabs, FGS900). The pump and the probe were focused onto the surface of the drop-cast NC films, which were contained in a 2-mm quartz cuvette. The instrument response function (IRF) of the TA setup was determined as 250 fs by measuring the full-width-at-half-maximum of the optical Kerr effect response of CCl4 in the same quartz cuvette. Kinetic traces were fit by convoluting this IRF with three exponential decay terms. Particle Imaging. All TEM images were acquired on samples drop-cast on a 400 mesh carbonon-copper TEM grid (Ted Pella). We drop-cast aliquots of the Cs2SnI6 NCs in toluene onto the S1

TEM grids supported on vacuum filtration paper. Particles were imaged using a JEOL JEM-2100 FasTEM and Hitachi HD-2300 Dual EDS Cryo STEM. The JEOL is equipped with high brightness Schottky FEG emitter operated at 200kV and a Gatan GIF camera. Hitachi is equipped with high brightness FEG operated at 80, 120 and 200 kv. Scanning electron microscopy (SEM) imaging was performed using cold source Field Emission SEM Hitachi SU8030 equipped with an electron beam accelerated at 500 V 30 kv. The films were deposited on glass and sputtered with a palladium/gold mixture before imaging. X-ray Diffraction Measurements. The XRD measurements were carried out on a RigakuMini-Flex600 X-ray diffractometer (CuKα radiation, λ = 1.5406 Å) operating at 40 kv and 15 ma. The films were prepared by drop-casting suspension of Cs2SnI6 NCs in toluene onto glass substrates that were cleaned with acetone and toluene before deposition. Photoluminescence Measurements. Photoluminescence measurements were carried out using a Witec alpha300 confocal imaging system at 532 nm. The films were prepared with a procedure identical to that for the XRD measurements. Infrared Spectroscopy Measurements. The Nexus 870 spectrometer is equipped with a tabletop optics module (TOM) that is used for Polarization Modulation Infrared Reflection Absorption Spectroscopy. It has an extended spectral range from 25,000 cm -1 to 400 cm -1 with a resolution of 0.125 cm -1. The attenuated total reflection (ATR) capability of a Thermo Nicolet FTIR system was used for the measurements on the films drop-casted on glass substrates S2

Figure S1. A) XRD patterns (black curve) of Cs2SnI6 NCs synthesized at 190 with Rietveld fitting (red curve) and their difference (blue curve). B) XRD patterns of Cs2SnI6 NCs films synthesized at various temperatures. The numbers on the left indicate the weight percentage of the product that is CsI. Figure S2. ATR FT-IR spectra of films of Cs2SnI6 NCs synthesized at 120 (blue curve) and190 (red curve). The background spectrum (black curve) only shows peaks corresponding to CO2 and H2O. S3

Figure S3. STEM images of Cs2SnI6 NCs synthesized at 100 Ԩ(A), 120 Ԩ(C), 150 Ԩ(E), 220 Ԩ(G) and corresponding size histograms (B, D, F, H). S4

Figure S4. A) HRTEM image of a Cs2SnI6 NC and its B) gray scale intensity profile Figure S5. Photographic image of an as-deposited Cs2SnI6 NCs film. S5

Figure S6. SEM images of electrosprayed Cs2SnI6 films prepared by deposition of a solution of SnI4 and CsI in methanol show A) rings forming in the film at the edge of the spray area and B) large vacancies from non-uniform crystal growth. Figure S7. A) Dependence of the average diameter of Cs2SnI6 NCs, calculated with Scherrer equation from powder XRD patterns, on the injection temperature. B) Dependence of the band gap energy, measured by diffuse reflectance, on injection temperature. The error bars in both plots are calculated from 4 separate measurements on separately prepared samples. S6

Figure S8. A) Steady state absorption spectra (acquired in transmission mode) and B) photoluminescence spectra (acquired in reflection mode) of the Cs2SnI6 NC films prepared with different injection temperatures. REFERENCES (1) McArthur, E. A.; Morris-Cohen, A. J.; Knowles, K. E.; Weiss, E. A. Charge Carrier Resolved Relaxation of the First Excitonic State in CdSe Quantum Dots Probed with Near-Infrared Transient Absorption Spectroscopy. J. Phys. Chem. B 2010, 114, 14514-14520. S7