Cable Cover Guide. Color List... W White B Black P Premium Wood (stainable Floor Trim only) shape & size (wxh) colors available

Similar documents
Trunking Guide. Colour List... W White M Magnolia B Black. shape & size (wxh) colours available

Innovative Cable Management. Supplied by

Prestige 2Com Technical

150mm to 200mm. With box in comp 2 2 = 1535mm² total area 2 = 691mm² 45% space factor. C. & C. Marshall Ltd.

rondo exangle drywall finishing sections

Tools and Tips: ( 1 )

Cablelink Plus Flush Technical

Pinnacle Technical. Bench and Shelf Trunking. cable management perimeter and distribution. Features.

TOOLS REQUIRED: HARDWARE INCLUDED: 13MM FLAT WRENCH FOR LEVELING THE STRUCTURE RATCHET WITH 5MM HEX BIT FOR CORNER SCREWS ON TOP TRAVERSE BEAMS

CABLE COVER ORGANIZER KIT USER GUIDE AND INSTALLATION INSTRUCTIONS

Risk Assessment & Safe Working Practice

DLP-S Trunking LIMOGES Cedex. Phone : Fax :

INSTALLATION AND CARE INSTRUCTIONS

PRESTIGE 3D COMPACT RANGE INTRODUCTION PERIMETER AND DISTRIBUTION FEATURES & BENEFITS CABLE MANAGEMENT

installation instructions WC Frame 1180mm with Dual Flush Cistern

Wall Panel Installation Instructions

6MM ALLEN KEY FOR ROOF CLIPS PHILLIPS HEAD BIT FOR SCREWS FOR DOOR FRAME SPIRIT/LASER LEVEL TO LEVEL THE UNIT

Dubnium 11 Installation Instructions & Parts List

Jabiru Installation instructions

The easy way to an affordable kitchen

Pre-Paint>Fuselage>Empennage>Fit elevator. Objectives of this task: Materials required: Prepare the horizontal stabiliser and the elevator

Easyfix. Easyglaze. Superglaze. Filmglaze

installation instructions

Assembly Instructions

Bathroom Installation Manual

GENERAL CATALOGUE. Connectivity for workplaces

Radon 07 Installation Instructions & Parts List

Curium 19H Installation Instructions & Parts List

Powerlink Plus Technical

INSTALLATION AND CARE INSTRUCTIONS

multipanel Installation (panels) CONTENTS

TOYOTA CAMRY LIP SPOILER Preparation

Storing, Handling, and Cleaning dekō Markerboards Storing Markerboards. Handling. Cleaning

Installation And Care Instructions. Vertical Honeycomb Shades

13MM FLAT WRENCH FOR LEVELING THE GLIDES OF STRUCTURE 6MM ALLEN KEY FOR ROOF CLIPS PHILLIPS HEAD BIT FOR SCREWS FOR DOOR FRAME

GENUINE PARTS INSTALLATION INSTRUCTIONS

IMPORTANT INSTALLATION GUIDE VALENCIA ANGLE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION

Please read these instructions before use and keep for future reference

Tech Sheet. T4 Interior conversion kit how to - fitting instructions. 1. Rear seat belts. 2.

EMAC 001 ACCESS PANEL

Installation Guide for PermaSnap Plus Coping

Curium 19.4H Installation Instructions & Parts List

Prepare Base Assembly. (If pump is pre-assembled on base, go to step#8.)

Vertical Honeycomb Shades

Products. Scotia. Standard Universal Door Bar. Deluxe Universal Door Bar. Aluminium Universal Door Bar. The edge. Stick-on Edge Trim

4 Position the Suntile to the x tile s position and mark the felt around the square box flange. Then remove the Suntile

Leafy Greens Spinner Construction Manual

INSTALLATION INSTRUCTIONS

(2) 25mm x 20mm x 5mm Adhesive Backed Foam Pads. 100mm x 50mm x 1.0mm Adhesive Backed Foam. (2) Spacer Plates. Passenger/Right Side Frame Mounting

3. Be careful not to cut off all of the adjustment screws. It may be better to take a little off of each end rather than all off one side.

Installation guide. ROCKFON VertiQ. ROCKFON System T, ROCKFON System HAT. Impact-resistant and high impact-resistant acoustic wall panel solutions

PVC Composite Railing & Stair Kit

NX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP

General catalogue Export SMOUTS ARCHITECTEN

STYLE BAR & TONNEAU COVER INSTALLATION

Bathroom Installation Guide

WET AREA PANELLING. Designer Walls. Fast

Xenon 05 Installation Instructions & Parts List

Siding Systems NOVIKSTONETM DS DRY STACK STONE INSTALLATION GUIDE

Wall Panel Installation

Panel Riser Kit Option 1. Installation Instructions 226BEE 0117CH

POP PLUS / SPIDER SET-UP INSTRUCTIONS

metal sided pot drawer soft close

Transition Range Installation, Care & Adjustment Instructions

Installation Instructions. Oakmont Folding Doors

INSTALLATION GUIDE. 1. Overview. 2. Measuring. 3. Tools & fixings you will need B C. Opening Width. Opening Height

MX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP

Argon 02 Installation Instructions & Parts List

Wet Area Panelling. Linear Series

REHAU PROFILA BENCH TRUNKING INSTALLATION GUIDELINES. Building Solutions Automotive Industry

Gallium 03 Installation Instructions & Parts List

Quantum 2 SQUARE 0808K

STORAGE & SHELVING SYSTEM - INSTALLATION GUIDE

C6 Corvette Rear Spoiler Kit CDC #

Installation Instructions

Installation Guide. brighter. lighter.

Linda Barker Collection Heritage Collection Classic Collection INSTALLATION GUIDE

CLASSIC RANGE PLUS RANGE CREATE RANGE - PHOTO WALL

Cobra X Q Construction Tips Construction: Bel y pan

Installation Instructions Palladium Square Edge Panels

INTRODUCTION Tools Required Laminate Washroom Products... 4 DUCT PANELS Fixing the Frame: Fixing the Shadow Panels...

Exploded View PAGE 2 OF 9

CLASSIC RANGE PLUS RANGE PHOTO WALL. Pre-installation check-list

" BASE CABINET

B A T H R O O M G L A S S

INSTALLATION INSTRUCTIONS. Deluxe Continuous Hinge Inline Door & Panel Shower Enclosure QCI5230

HONDA RIDGELINE (KIT #601) Installation Instructions (to be used in addition to owners manual)

Tools Required. Bench Hardware. Bench Parts. Planter Hardware. Planter Parts. BENCH/PLANTER INSTALLATION GUIDELINES for

FRAMED PANEL / DOOR / PANEL CONTINUOUS HINGE SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

STAKS. Crossover Casegoods ASSEMBLY INSTRUCTIONS

LF Series Assembly Instructions

Raised Floor system LIMOGES Cedex. Phone : Fax :

SZD-10 bis CZAPLA ASSEMBLY MANUAL IN PICTURES

Closet System Installation Manual

Norwich Technical. Trunking PERIMETER AND DISTRIBUTION. Description CABLE MANAGEMENT. Colour: White only. Material: PVCu. mkelectric.co.

Single Sided Height Adjustable Benching

Tools and Tips: ( 1 )

Project: Client: Part #: NEON -P FLT HB 24VDC WHT lc con cab. Date: Qty:

IMPORTANT READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION

FlowBar Architectural Linear Diffusers F L- 1 0 / F L-15 / FL-2 0 F L- 2 5 / F L-30 I NSTA LL AT IO N & OPER AT I ON M AN UA L

Transcription:

Cable Cover Guide Color List... W White B Black P Premium Wood (stainable Floor Trim only) illustrations not to scale Maxi TV Drop Mini Micro Floor Trim shape & size (wxh) colors available 2⅜ x 13/16 2 x 1 13/16 x ⅝ ⅝ x 5/16 ⅞ x ⅞ W W B W W W P Trunking Lengths 5 Length 6½ Length Clip Over Accessories Flat Bend use internal bend Internal Bend External Bend Equal Tee Door Top Bend Inlet/Outlet Coupler (floor trim only) Smooth Fit Accessories Flat Bend use internal bend Internal Bend External Bend Equal Tee Cable Outlet use equal tee Cable Inlet Reducing Tee (to Mini) Coupler End Cap End Cap Left (Floor Trim only) End Cap Right (Floor Trim only) Pattress Adaptor Circular Adaptor Other Accessories Ratchet Cutting Tool Clip Over Accessories Smooth Fit Accessories

How Clip-Over Accessories Work All Clip-Over accessories have grip tabs. The grip tab simply clips over the top of the length The grip tab fits neatly into the gap provided by the self-adhesive foam tape ½ Round Clip Over Accessories (Mini only) Internal Bend External Bend Flat Bend Equal Tee Door Top Bend ½ Round Smooth Fit Accessories Internal Bend External Bend Flat Bend Equal Tee Coupler End Cap Circular Adaptor Patress Adaptor Cable Inlet/Outlet Reducing Tee ¼ Round Clip Over Accessories Internal Bend External Bend Cable Inlet/Outlet ¼ Round Smooth Fit Accessories Internal Bend External Bend Cable Inlet Cable Outlet Connector End Cap

5 /16 ⅝ Micro Cable Cover PVC base & lid Elastomer hinge Available Colours UV stabilised Operating temperature ½ round design External Dimensions Popular usages Tape Weight Packaging Capacity Accessories Available Light weight, easy to handle & cut Self-extinguishing Can be drilled Effectively bonds base & lid Lid cannot detach Low-maintenance Keeps cables in place during installation Impact absorbing Can be opened & closed thousands of times White Will not discolour or turn brittle in sunlight Stable between -30 C upto +60 C No sharp edges Enables subtle aesthetics Blends above skirting The smallest profile ⅝ x 5 /16 (w x h) aka Micro To contain wires e.g. low-voltage, telephone cables, speaker wires, alarm cables Foam backed Effective on clean dry surfaces Caution, can spoil surfaces on removal Scuff using gentle abrasive such as sandpaper, so paint keys for best results 1.54 lbs per ft Each length supplied with removable film cover It is recommended to leave 45% of internal capacity for air circulation Yes (Smooth-Fit style)

⅝ 1 3 /16 Mini Cable Cover PVC base & lid Elastomer hinge Available Colours UV stabilised Operating temperature ½ round design External Dimensions Popular usages Tape Weight Packaging Capacity Accessories Available Light weight, easy to handle & cut Self-extinguishing Can be drilled Effectively bonds base & lid Lid cannot detach Low-maintenance Keeps cables in place during installation Impact absorbing Can be opened & closed thousands of times White Will not discolour or turn brittle in sunlight Stable between -30 C upto +60 C No sharp edges Enables subtle aesthetics Blends above skirting 1 3 /16 x ⅝ (w x h) aka Mini For satellite, aerial & broadband cables; for surface switch and socket installations Cable drops, above skirting tops and across ceilings; for lighting and smoke alarm installations Foam backed Effective on clean dry surfaces Caution, can spoil surfaces on removal Scuff using gentle abrasive such as sandpaper, so paint keys for best results 0.33 lbs per ft Each length supplied with removable film cover It is recommended to leave 45% of internal capacity for air circulation Yes, Smooth-Fit or Clip-Over options

1 2 8 TV Cable Cover PVC base & lid Elastomer hinge Available Colours UV stabilised Operating temperature ½ round design External Dimensions Popular usages Tape Weight Packaging Capacity Accessories Available Light weight, easy to handle & cut Self-extinguishing Can be drilled Effectively bonds base & lid Lid cannot detach Low-maintenance Keeps cables in place during installation Impact absorbing Can be opened & closed thousands of times White Black Will not discolour or turn brittle in sunlight Stable between -30 C upto +60 C No sharp edges Enables subtle aesthetics 2 x 1 (w x h) aka TV Drop Hide cables from wall-mounted TVs; Hide cables on underside of desktops and up desk legs Foam backed Effective on clean dry surfaces Caution, can spoil surfaces on removal Scuff using gentle abrasive such as sandpaper, so paint keys for best results 0.6 lbs per ft Each length supplied with removable film cover It is recommended to leave 45% of internal capacity for air circulation Can contain up to 6+ popular TV cables Yes (Smooth-Fit style)

1 3 /16 2⅜ 8 Maxi Cable Cover PVC base & lid Elastomer hinge Available Colours UV stabilised Operating temperature ½ round design External Dimensions Popular usages Tape Weight Packaging Capacity Accessories Available Light weight, easy to handle & cut Self-extinguishing Can be drilled Effectively bonds base & lid Lid cannot detach Low-maintenance Keeps cables in place during installation Impact absorbing Can be opened & closed thousands of times White Will not discolour or turn brittle in sunlight Stable between -30 C upto +60 C No sharp edges Enables subtle aesthetics 2⅜ x 1 3 /16 (w x h) aka Maxi - our largest profile! Hide cables from wide screen wall-mounted TVs Foam backed Effective on clean dry surfaces Caution, can spoil surfaces on removal Scuff using gentle abrasive such as sandpaper, so paint keys for best results 0.85 lbs per ft Each length supplied with removable film cover It is recommended to leave 45% of internal capacity for air circulation Can contain up to 8+ popular TV cables Yes (Smooth-Fit style)

⅞ ⅞ Stainable ¼-Round Floor Trim PVC base & lid Elastomer hinge Available Colours UV stabilised Operating temperature ¼ round design Light weight, easy to handle & cut Self-extinguishing Can be drilled Effectively bonds base & lid Lid cannot detach Low-maintenance Keeps cables in place during installation Impact absorbing Can be opened & closed thousands of times White Stainable External Dimensions ⅞ x ⅞ (w x h) Popular usages Tape Weight Packaging Capacity Accessories Available Will not discolour or turn brittle in sunlight Stable between -30 C upto +60 C No sharp edges Enables subtle aesthetics For horizontal (& vertical) 90 degree intersections Covers expansions gaps around floor edges Indoors as Floor Trim; for Worktops; Corner drops Foam backed Effective on clean dry surfaces Caution, can spoil surfaces on removal Scuff using gentle abrasive such as sandpaper, so paint keys for best results 0.33 lbs per ft Each length supplied with removable film cover It is recommended to leave 45% of internal capacity for air circulation Yes, including Clip-Over bends & Inlet/Outlet Connector

Clip-Over Accessories for ½ Circle Cable Cover Rear Grip Tabs Abs material Popular usage Easy-to-install Hold Accessory in gap between flat surface and D-Line length, as made possible by depth of rear foam-tape Robust material Scuff using gentle abrasive such as fine sandpaper, so paint keys for best results Available for Mini (1 3 /16 x ⅝ ) Clip-Over style can forgive poor cuts at length ends, and imprecise measuring so saving installation time Accessory Name Description Weight Internal Bend Join lengths around 90 degree inside corners 0.14oz (Mini 1 3 /16 x ⅝ profile only) External Bend Join lengths around 90 degree outside corners (Mini 1 3 /16 x ⅝ profile only) 0.1oz Flat Bend Use between 2 lengths that change direction by 90 degrees on flat surfaces (Mini 1 3 /16 x ⅝ profile only) 0.1oz Equal Tee Use to clip over 3 lengths of same profile (Mini 1 3 /16 x ⅝ profile only) 0.1oz Door Top Bend Use to clip over interface of vertical and horizontal lengths (Mini 1 3 /16 x ⅝ profile only) 0.14oz

Accessory Name Description Weight Internal Bend Join lengths on flat surfaces 0.1oz External Bend Neatly finish open ends 0.1oz

Smooth-Fit Accessories for ½ Circle Cable Cover Internal shoulders Abs material Enables smooth appearance along installation Creates secure fitment - will not drop off Enable smooth flush alignment between lengths for perfect finish Robust material Can be modified for fitment on uneven surfaces Scuff using gentle abrasive such as fine sandpaper, so paint keys for best results Accessory Name Description Size Weight Internal Bend Join lengths around 90 degree inside corners Micro - ⅝ x 5 /16 TV Drop - 2 x1 Maxi - 2⅜ x 1 3 /16 0.04oz 0.24oz 0.70oz External Bend Join lengths around 90 degree outside corners Micro - ⅝ x 5 /16 TV Drop - 2 x1 Maxi - 2⅜ x 1 3 /16 0.04oz 0.50oz 0.50oz Flat Bend Use between 2 lengths that change direction by 90 degrees on flat surfaces Requires care in measuring gap required for each Accessory, then cut straight length(s) end so Accessory fits neatly between lengths Micro - ⅝ x 5 /16 TV Drop - 2 x1 Maxi - 2⅜ x 1 3 /16 0.04oz 0.50oz 0.77oz Equal Tee Join 3 lengths of same profile Micro - ⅝ x 5 /16 TV Drop - 2 x1 Maxi - 2⅜ x 1 3 /16 0.04oz 0.14oz 0.60oz 0.81oz Connector Join 2 lengths of same profile on flat surface Micro - ⅝ x 5 /16 TV Drop - 2 x1 Maxi - 2⅜ x 1 3 /16 0.04oz 0.50oz 0.77oz End Cap Neatly finish open ends Micro - ⅝ x 5 /16 TV Drop - 2 x1 Maxi - 2⅜ x 1 3 /16 0.04oz 0.50oz 0.77oz

Accessory Name Description Size Weight Circular Adaptor Connect Mini D-Line to flat edge surface boxes with 20mm diameter 3 circular knock-outs 0.17oz Patress Adaptor Connect Mini D-Line(interfaces with 30x15mm only) to round Surface Boxes Cable Inlet/Outlet Takes cables in or out of a Mini installation. Use between lengths on straight runs Installation Tips Plan your cable path. Check that you have all parts required. Next consider the space that will be required for any accessories needed - Smooth-Fit ccessories give a smooth flush-alignment for perfect finish, but require precise measurements and straight cuts. Use the accessory part as a template; pencil mark the surface at the shoulder points of the accessory. These pencil marks indicate the point that the D-Line length needs to measure up to. example... Measure length(s). Pencil mark where cut is required. Use a mitre block and junior hacksaw to cut at the outer edge of the pencil mark. Remove the protective film cover. Peel & stick.. Make sure the surface is clean & dry. Alternatively lengths can be drilled and screw fixed. For easier installation we recommend that horizontal runs are fixed with the click lock at the top and the hinge at the base. Take care when positioning lengths, as a strong bond will be created with the surface. Installing cables & accessories Lay wires into lengths, place the required accessory over the wires, then close the lid ensuring it snaps shut. The lengths hold the accessories in position. Internal Bend External Bend Flat Bend lengths need to touch Equal Tee Cable Inlet/Outlet Connector End Cap It may be necessary to shape some accessories to allow for imperfections on walls. After Care D-Line can accept gloss or emulsion paints... For best results use fine sandpaper to key the surface prior to painting. Important: It is recommended you leave 45%+ of internal capacity for air circulation.

Clip-Over Accessories for ¼ Circle Floor Trim Rear Grip Tabs Abs material Easy-to-install Hold Accessory in gap between flat surface and D-Line length as made possible by depth of rear foam-tape Robust material Can be modified for fitment on uneven surfaces Scuff using gentle abrasive such as fine sandpaper, so paint keys for best results Clip-Over style can forgive poor cuts at length ends, and imprecise measuring so saving installation time Accessory Name Description Weight Internal Bend Join lengths around 90 degree inside corners External Bend Join lengths around 90 degree outside corners Cable Inlet/Outlet Use to provide cable entry/exit point between 2 lengths Connector Joins 2 lengths on flat surfaces End Cap Neatly finish open ends Simply push in. (note: left & right versions apply)

Smooth-Fit Accessories for ¼ Circle Floor Trim Internal shoulders Abs material Enables smooth appearance along installation Creates secure fitment - will not drop off Enable smooth flush alignment between lengths for perfect finish Robust material Can be modified for fitment on uneven surfaces Scuff using gentle abrasive such as fine sandpaper, so paint keys for best results Accessory Name Description Weight Internal Bend Join lengths around 90 degree inside corners External Bend Join lengths around 90 degree outside corners Cable Inlet Use to provide cable entry point between 2 lengths Cable Outlet Use to provide cable exit point between 2 lengths Connector Joins 2 lengths on flat surfaces End Cap Neatly finish open ends Simply push in. (note: left & right versions apply)

Installation Tips Plan your cable path. Check that you have all parts required. Next consider the space that will be required for any accessories needed - Smooth-Fit accessories give a smooth flush-alignment for perfect finish, but require precise measurements and straight cuts. Use the accessory part as a template; pencil mark the surface at the shoulder points of the accessory. These pencil marks indicate the point that the D-Line length needs to measure up to. example... Cutting & Installing Lengths Measure length(s). Pencil mark where cut is required. Use a mitre block and junior hacksaw to cut at the outer edge of the pencil mark. Remove the protective film cover. To peel & stick... Make sure the surface is clean & dry. For easier installation we recommend that horizontal runs are fixed with the click lock at the top and the hinge at the base. Take care when positioning lengths, as a strong bond will be created with the surface. Installing cables & accessories Lay wires into lengths, place the required accessory over the wires, then close the lid ensuring it snaps shut. The lengths hold the accessories in position. Internal Bend External Bend Cable Inlet/Outlet lengths need to touch Connector End Cap After Care D-Line can accept gloss or emulsion paints... For best results use fine sandpaper to key the surface prior to painting. It may be necessary to shape some accessories to allow for imperfections on walls. Important: If using D-Line for 240v mains cables it is recommended you leave 45%+ of internal capacity for air circulation.