pacific build supply ltd

Similar documents
NATURA PRO Product Information Leaflet 1

March High performance building boards

9.0 PS Pacbld Sidings

INTERNAL LININGS INSTALLATION GUIDE

Ulltraclad Aluminium Cladding. Contents. 1.0 General Information Design Information Installation Information 7. 4.

The Passive Fire Protection Handbook

Installation Manual for Thermo Panel

Fir and pine wood (52 %) Portland cement (38 %) made by firing limestone and clay Water (9 %) Wood mineralisation substances (1 %)

The Passive Fire Protection Handbook

The Passive Fire Protection Handbook

PAREFEU PANEL Environmentally Sustainable Product with High Fire Rating

WET AREA PANELLING. Designer Walls. Fast

DYNEX SOFFIT SYSTEM. Product. Scope. Building Regulations. Appraisal No. 908 [2016] Appraisal No. 908 (2016) BRANZ Appraisals

Wet Area Panelling. Linear Series

Processing and design Solid Textile Board

4256HM JAMES HARDIE MONOLITHIC CLADDING

JAMES HARDIE RIGID AIR BARRIERS

CEILINGS INSTALLATION GUIDE

Installation Manual for M4-Exterior Sheathing

SlipGrip Data Sheet & Installation Guide

Installation Guide. PineRidge Lining INTERIORS

Installation Guide. Versilux Lining INTERIORS

GREEN WORLD LUMBER GENUINE MAHOGANY DECKING INSTALLATION GUIDE

Rev. 05/16 01 ACRYLIC INSTALLATION GUIDE

Cabonyx Installation Manual

Technical Documentation

INSTALLATION INSTRUCTIONS MILLENNIUM DECKING Before Installing Millennium Decking, please read these instructions in their entirety.

DECKING INSTALLATION GUIDE

MANUFACTURE GUIDELINES

Installation Guide. Pionite Decorative Surfaces One Pionite Road, Auburn, Maine PIONITE ( )

MAGNUM BOARD INTERIOR INSTALLATION GUIDELINES

GOLDENEDGE MDF PANELBRACE WALL BRACING SYSTEMS. Product. Scope. Building Regulations. Appraisal No. 779 [2018] Logo

September 10, 2009 Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

Axent FASCIA. Installation Manual AUGUST 2014 I NEW ZEALAND

Linda Barker Collection Heritage Collection Classic Collection INSTALLATION GUIDE

Inteplast Trim Free Foam

SHIPLOCK CLADDING PRODUCT GUIDE INSTALLATION TECHNICAL SPECIFICATIONS CARE & MAINTENANCE

KEITH PANEL SYSTEMS FUNDERMAX- MAX EXTERIOR EXPOSED FASTENER PRESSURE EQUALIZED WALL SYSTEM

BARRELL VAULT BATTENLESS

Cembrit Patina. Cembrit Cover. Cembrit Solid. Cembrit Transparent

INSTALLATION MANUAL STORAGE

Ignitability Index Spread of Flame Index Heat Evolved Index Smoke Developed Index. Range 0-20 Range 0-10 Range 0-10 Range

How to: Line a masonry fireplace with PROMAFOUR

INSTALLATION MANUAL AUSTRALIA FEBRUARY 2005

VERSAROC CEMENT BONDED PARTICLE BOARD ROOF SHEATHING VERSAROC CEMENT BONDED PARTICLE BOARD ROOF SHEATHING

Timber Appeal. With Fibre Cement Durability

IFRC SHELTER TOOL KIT

NULINE PLUS WEATHERBOARD DIRECT FIXED CLADDING SYSTEM. Product. Scope. Appraisal No. 640 [2015]

KuraStone TM Installation Guide

I N S TA L L AT I O N & M A I N T E N A N C E G U I D E

FRAMED PANEL / DOOR / PANEL CONTINUOUS HINGE SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

PolyCarb has good resistance to many chemicals. Some chemicals may harm the PolyCarb sheets. Contact us when in doubt about any chemical.

Particleboard. The tradesman s essential guide

INSTALLATION INSTRUCTIONS FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE QCI5233

DIY CHILD S STOOL. Instructions

Flexible Diamond Disc

Contents. Installation Guide. Dynex Soffit Installation Guide V03 March The Smart Choice in Soffit

Masking: Each mirrored sheet is well protected by a durable paint backing and

Installation Instructions

Side Light Frame Pack Assembly Instructions

Installation Instructions for. Before You Begin TOOLS REQUIRED

CLASSIC RANGE PLUS RANGE PHOTO WALL. Pre-installation check-list

Ask your DIY store or carpenter to cut the required boards to size. Instructions. 1. Cut out the opening for the bottles

UNIT 11: PAINTING, STAINING, AND FINISHING

Side Light Frame Pack Assembly Instructions

BBS Rusticated & Splaycut Cavity System

Working with Wood and Wood Materials

DURACRYL WALL INDEX INTRODUCTION. TOOLS AND MATERIALS REQUIRED. FLAT SHOWER WALL SIDE CONTOUR SHOWER WALL CORNER CONTOUR SHOWER WALL FLAT BATH WALL

COMPOSITE SIDING INSTALLATION GUIDE

VIEWpanel Technical Manual

Product Overview. Electric Pneumatic Hydraulic. Concrete and Masonry Dust Collection Systems Hot Work Zone Tools

NewTech - CleverDeck Composite Decking Installation Guidelines

MAXISHINGLE LAP SIDING INSTALLATION GUIDE

UCO Vistabord Fixing Manual

STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS

Robert Bosch GmbH. Lounge light fixture

SIMPLY DIFFERENT! VISCOM SIGN the lightweight foam board

Flexicryl Splashback Installation Guide Easy DIY Add a Pop of Colour!

Deluxe Continuous Hinge Framed Door & Inline Panel with Return Panel Shower Enclosure

WITH HEAT - NATURALLY

Perfect sawing. The complete FEIN program for sawing: Jigsaws P Hacksaws P With the FEIN sabre saw through thick and thin with ease.

L u m b e r M e l a m i n e H a r d w o o d P l y w o o d A r c h i t e c t u r a l P a n e l s C o l o r e d C a u l k P a r t i c l e B o a r d E

INSTALLATION GUIDE DUOFUSE SLAT WALL SYSTEM

Barrel Vault Counter Batten and Batten

The cost effective wood panel choice. Applications

Resysta 6 and 4 Flat Board Siding System Assembly Installation Guidelines

Craftform. The tradesman s essential guide

Residential Treated Wood Use Category Guide

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement

Installation Guide. Shingles. Classical. Shingles. Warning. Storage. Cutting Shingles. Touch-Up. Eastern White Cedar

Salter Industries Spiral Stair

PANELTEK ENGINEERED SIDING/PANELLING INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Durabrac Gable Bracket Installation Guide

Aluminum Clad Wood Window Field Mulling and Stacking Instructions

Endura-Stone Installation Instructions

COFFEE TABLE WITH RECESSED TRAY

KEITH PANEL SYSTEMS FUNDERMAX- MAX EXTERIOR CONCEALED FASTENERS PRESSURE EQUALIZED WALL SYSTEM

EZYSTONE WORKSURFACES

A. All trim that has been damages, broken, or missing shall be repaired or replaced with material of the same size, shape, and type.

Transcription:

Product Information ETERPAN is a medium density fibre cement sheet that is used for external cladding, plastered finish, base for stone and brick slips, rigid air barrier, weatherboards, soffits, louvres, decks, internal linings, ceilings, flooring, tile and slate underlay. 1. Product composition ETERPAN sheets consist of the following: Portland cement Mineral fillers Organic reinforcing fibres Functional additives 2. Production method ETERPAN sheets are manufactured on a FLOW-ON machine and are autoclaved at high temperature and pressure. ETERPAN is produced by Etex Group, the most global manufacturer of fibre cement with production facilities in 40 different countries. The FLOW-ON production process is different from the more traditional Hatschek process as it produces fibre cement in a more monolithic core and has superior water, frost and delamination resistance. There are 3 distinctive ETERPAN products available - Eterpan REFINED with a sanded surface - Eterpan BASE with an unsanded surface - Eterpan Siding, the weatherboard range produced with ETERPAN technology 3. Dimensions and tolerances Standard thickness: 4.5, 6.0, 7.5, 9.0, 12.0, 15.0, 20.0 mm ETERPAN BASE 4.5 mm (for Rigid Air Barrier, plastered finish) PBS0209/1 2400 x 1200 mm No X X PBS0210 2700 x 1200 mm No X X PBS0211 3000 x 1200 mm No X X ETERPAN SEALED for use as Rigid Air Barrier PBS0209/1S 2400 x 1200 mm No X X PBS0210/S 2700 x 1200 mm No X X PBS0211/S 3000 x 1200 mm No X X

ETERPAN BASE 4.5 mm (for soffits) PBS0203 2400 x 300 mm Yes X X PBS0205 2400 x 450 mm Yes X X PBS0206 2400 x 600 mm Yes X X PBS0207 2400 x 750 mm Yes X X PBS0204 2400 x 900 mm Yes X X PBS0209 2400 x 1200 mm Yes X X ETERPAN BASE 6.0 mm (for Rigid Air Barrier, Wall and floor underlay for tiling, plastered finish over 10 m high) PBS0217 1800 x 900 mm YES X X PBS0218 1800 x 1200 mm YES X X PBS0220 2400 x 1200 mm YES X X PBS0221 2700 x 1200 mm YES X X PBS0222 3000 x 1200 mm YES X X ETERPAN SEALED for use as Rigid Air Barrier PBS0220/S 2400 x 1200 mm YES X X PBS0221/S 2700 x 1200 mm YES X X PBS0222/S 3000 x 1200 mm YES X X ETERPAN REFINED 6.0 mm (for internal linings, soffits, ceilings) PBS0225 2400 x 1200 mm YES X X PBS0226 2700 x 1200 mm YES X X PBS0227 3000 x 1200 mm YES X X PBS0220/1 2400 x 1200 mm YES X X ETERPAN BASE 7.5 mm (for Rigid Air Barrier) is not a standard stock product. ETERPAN REFINED 7.5 mm (for soffits, fencing, ceilings) Code Trimmed Grooved Unsanded Sanded Square Tapered PBS0235 2400 x 1200 mm YES X X PBS0236 2700 x 1200 mm YES X X PBS0237 3000 x 1200 mm YES X X PBS0270 2400 x 1200 mm YES YES X X ETERPAN BASE 9.0 mm (for plastered finish, base for stone slips, fencing, underlay wall tiling) PBS0240 2400 x 1200 mm YES X X PBS0241 2700 x 1200 mm YES X X PBS0242 3000 x 1200 mm YES X X ETERPAN SEALED for use as Rigid Air Barrier PBS0240/S 2400 x 1200 mm YES X X PBS0241/S 2700 x 1200 mm YES X X PBS0242/S 3000 x 1200 mm YES X X PBS0245 2400 x 1200 mm YES X X PBS0246 2700 x 1200 mm YES X X PBS0247 3000 x 1200 mm YES X X

ETERPAN REFINED 9.0 mm (for cladding negative detail, soffits, internal linings, ceilings, fencing) PBS0240/1 2400 x 1190 mm YES X X PBS0241/1 2700 x 1190 mm YES X X PBS0242/1 3000 x 1190 mm YES X X PBS0245/1 2400 x 1200 mm YES X X PBS0246/1 2700 x 1200 mm YES X X PBS0247/1 3000 x 1200 mm YES X X ETERPAN BASE 12.0 mm (for handrails) PBS0250 2400 x 1200 mm Yes X X PBS0252 2700 x 1200 mm Yes X X ETERPAN REFINED 15.0 mm (for trims, handrails) PBS0257 3000 x 1200 mm Yes X X ETERPAN BASE 20.0 mm (for decks) PBS0260 2400 x 1200 mm Yes X X ETERPAN SIDING150 and SIDING180 - thickness 15.0 mm PBS0606 3000 x 150mm Yes X X PBS0600 3000 x 180 mm Yes X X ETERPAN SIDING CEDAR thickness 7.5 mm PBS0391 3000 x 190 mm Yes X X ETERPAN SIDING SMOOTH thickness 7.5 mm PBS0437 3000 x 190 mm Yes X X Tolerances Thickness Length and width Untrimmed + /- 0.5 mm + /- 5.0 mm After cutting + /- 0.5 mm + /- 1.5 mm Squareness 3.0 mm / m 1.0 mm / m

4. Weight (average values, including average moisture content) Thickness Weight 4.5 mm 6.5 kg/m 2 6 mm 8.6 kg/m 2 7.5 mm 10.8 kg/m 2 9 mm 13.0 kg/m 2 12 mm 17.3 kg/m 2 15 mm 21.6 kg/m 2 20 mm 28.8 kg/m 2 Eterpan Siding Thickness Weight Siding 150 15.0 mm 9.1 kg/piece Siding 180 15.0 mm 10.9 kg/piece Cedar 7.5 mm 5.8 kg/piece Cedar Smooth 7.5 mm 5.8 kg/piece 5. Colours ETERPAN comes in a light beige colour. No other colours are available. 6. Testing and technical properties (average values) Eterpan sheets are classified Type A under the requirements of AS 2908.2-1992 Cellulose Cement Products, Part 2 Flat sheets. Eterpan has been tested by BRANZ and reported in MTR 1083 to AS 2908.2 which defines standards of performance for flat sheets of cellulose-cement products. The results are summarised as follows:- (i) (ii) (iii) (iv) (v) Determination of Flexural Strength Modulus of Rupture: results gave Eterpan a category 2 for a type A board (external use) in AS 2908.2, section 6. Determination of Water tightness: requirements for a type A (external) sheet in AS 2908.2 met (i.e no water droplets on the reverse side of the sheet were evident). Determination of Resistance to Hot Water Soaking: after hot water soaking the test samples did not show any visible cracks, structural alteration, or delamination as required in AS 2908.2 for type A (external sheets). The 95% confidence limit of the ratio of mean hot water MOR to mean control MOR was above 0.8 as also required. Determination of Resistance to Heat/Rain: after heat/rain exposure, the test samples did not show any visible cracks, structural alteration, or delamination as required in AS 2908.2 for type A (external sheets). Determination of Resistance to Freeze/Thaw: after freeze/thaw exposure, the test samples did not show any visible cracks, structural alteration, or delamination as required in AS 2908.2 for type A (external sheets). Code Compliance Eterpan has a BRANZ 50 year durability opinion, ref BDO 98/3 and meets the following performance criteria of the N.Z.B.C. 1. Durability: a. When as a non structural part of the building envelope Eterpan meets the N.Z.B.C durability requirement of 15 years according to clause B2.3.1(b). b. When as a structural part of the building envelope Eterpan meets the N.Z.B.C durability requirement of 50 years according to clause B2.3.1(a), when coated with a water impermeable treatment, maintained over the life of the product. c. Eterpan is producer guaranteed against physical or mechanical deterioration for 50 years.

2. Hazardous Building Materials: Eterpan is a non hazardous product according to N.Z.B.C Performance F2. Density : > 1200 kg/m³ Bending strength (24h immersed in water) // : 12.0 N/mm² Τ : 9.0 N/mm² Frost resistance : frost resistant Reaction to fire according to ISO 1182 : Non combustible Heat and total heat release rates AS/NZS 3837 : Eterpan has performance level A Smoke development : 0 Ignition : 0 Spread of Flame : 0 Heat Evolved : 0 7. Advantages No flame spread, no fume development, no toxic gasses Resistant to high temperatures Water resistant Truly monolithic core Resistant to fungae, bacteria, insects, vermin, etc. Resistant to many chemicals Environmentally friendly, no harmful gas emissions Frost resistant High dimensional stability Strong and rigid sheet Versatile and easy to install 8. Working guidelines Cutting: Pacific Build Supply Ltd operates a CNC waterjet cutting machine in Auckland that facilitates the cutting of intricate designs with minute tolerances. Please contact Pacific Build Supply Ltd for more information. For on site cutting: With a stationary saw, slow rotation with tungsten carbide-tipped blade or fast rotation with a fluted diamond cutting blade. With a hand circular saw (with rail), slow rotation with tungsten carbide-tipped blade or fast rotation with a fluted diamond cutting blade. With a jigsaw with tungsten carbide-tipped tooth cutting blade Conventional woodworking equipment can be used but in general wear faster and have lower quality edges. Edge finish: Use a fine emery cloth or sanding block to be sealed as part of the specified architectural finish. No other requirements for edge sealing. Drilling: For holes: carbide tipped twist drill with a 60 nose angle For round apertures: cup drill or circular cutter, carbide-tipped The sheet should be supported around the hole to be drilled (e.g. by a wooden surface). Cutting and drilling must take place in a dry environment. All residual dust must be removed immediately from the sheet with a dry towel to avoid permanent stains.

Fixing: The method and choice of the fixings (e.g. stainless steel, aluminium ) is dependent on the application and the environment. 1) Structural adhesive (concealed fixing): ETERPAN can be fixed with a structural adhesive. The back of the sheet must be sanded (sand paper P80) and sealed at the area where the adhesive is applied. The only adhesive to be used is specified by Pacific Build Supply Ltd in accordance with the Pacific Build Supply Ltd application guidelines. Further information is available from Pacific Build Supply Ltd. 2) Screwing: Use screws as specified by Pacific Build Supply Ltd. On XpressClad aluminium rails the screws are 19 mm long stainless steel self-tapping countersunk screws or 25 mm long stainless steel self tapping screws in combination with 10g stainless steel cup washers. To fix Eterpan on VentClad timber battens use 63 mm long stainless steel countersunk screws (for flushed finish) or 70 mm long stainless steel with sq drive head and stainless steel cup washers for featured fixings. Sheets need to be predrilled with the appropriate diameter. Respect the fixing patterns as specified by Pacific Build Supply Ltd. Min distance to the edge of the sheet is 15 mm and 100 and 50 mm to the edges at the corner of the sheets. 3) Nailing: In some applications, it is possible to nail Eterpan sheets. Specifications of the nails as well as fixing patterns depend on the application and can be found on the Pacific Build Supply website or by contacting Pacific Build Supply Ltd directly. Min distance to the edge of the sheet is 15 mm and 100 and 50 mm to the edges at the corner of the sheets. Caulking: Only use products recommended by Pacific Build Supply Ltd. Non-neutral silicones or thiokols can result in staining. Health and safety aspects: While the sheets are being processed, dust will be released which may irritate airways and eyes. It is recommended that a minimum P2 dust mask and safety goggles be worn. Appropriate dust extraction or proper ventilation should be used depending on the room in which the work is being carried out or the equipment being used. Long-term exposure to dust may be harmful to health. 9. Handling The sheets are packed on pallets. They must be kept dry during transport. The sheets must be horizontally stacked on a flat surface. The sheets must always be sufficiently supported so that they do not sag. The sheets must be stored in a dry ventilated space. If the sheets are stored outside, they must always be protected against rain by a tarpaulin or plastic sheet. If the sheets do become wet in the packing, all packaging must be removed and the sheets must be wiped dry and placed in a way that they can dry completely. A sheet must always be lifted from a stack by two people and then be carried on edge. 10. Guarantee The guarantee and the guarantee conditions are available on request from Pacific Build Supply Ltd,