CS-DS-01-KSV CS DISCLAIMER CS-PJ-01-KSV KS42SL EXPANDED PANEL JOINT CS-PJ-02-KSV KS42SL ENGAGED PANEL JOINT CS-PJ-03-KSV KS45SL EXPANDED PANEL JOINT CS-PJ-04-KSV KS45 FLAT ENGAGED PANEL JOINT CS-PJ-05-KSV KS45 FLAT EXPANDED PANEL JOINT CS-PJ-06-KSV KS45SL ENGAGED PANEL JOINT CS-PJ-07-KSV INTERMEDIATE SUPPORT CS-PJ-08-KSV INTERMEDIATE SUPPORT - SLIP CONNECTION CS-PJ-09-KSV LINER PANEL TO CONCRETE WITH SUPPORT CS-PJ-10-KSV LINER PANEL TO CONCRETE CS-BS-01-KSV BASE DETAIL - INSULATED SLAB HEAVY GAUGE ANGLE CS-BS-02-KSV BASE DETAIL - INSULATED SLAB LIGHT GAUGE Z CS-BS-03-KSV BASE DETAIL - PARTITION W/ FLOOR INSULATION CS-BS-04-KSV BASE DETAIL - INSULATED/NON-INSULATED CS-BS-05-KSV BASE DETAIL - PART. W/ CURBS INSULATED CS-BS-06-KSV BASE DETAIL - PART. NON-INSULATED CS-BS-07-KSV BASE DETAIL - LINER PANEL CS-BS-08-KSV BASE DETAIL - PART. W/ CURBS NON-INSULATED CS-BS-09-KSV BASE DETAIL - PART. W/ CURBS (ALTERNATE) CS-BS-10-KSV PARTITION BASE ON TOP OF CURB CS-OC-01-KSV OUTSIDE CORNER - FLUSH TRIM CS-OC-02-KSV OUTSIDE CORNER AT PARTITION CS-OC-03-KSV OUTSIDE CORNER LINER PANEL AT CONC WALL INDEX SHEET
CS-IC-01-KSV CS-IC-02-KSV CS-FO-01-KSV CS-FO-02-KSV CS-ST-01-KSV CS-RK-01-KSV CS-RK-02-KSV CS-EV-01-KSV CS-CE-01-KSV CS-CE-02-KSV CS-CE-03-KSV CS-CE-04-KSV CS-CE-05-KSV CS-CE-06-KSV CS-CE-07-KSV CS-CE-08-KSV CS-CE-09-KSV CS-CE-10-KSV CS-TL-01-KSV CS-TL-02-KSV CS-TL-03-KSV CS-TL-04-KSV INSIDE CORNER - FLUSH TRIM PARTITION TO EXTERIOR WALL HEADER CONDITION JAMB CONDITION STACK JOINT RAKE RAKE W/ MEMBRANE ROOF LOW EAVE INTERIOR WALL TO CEILING INTERIOR WALL TO CEILING - 'T' SECTION CEILING CHANNEL CEILING TEE CEILING TEE ASSEMBLY CEILING CHANNEL ASSEMBLY CEILING TO WALL - LONGITUDINAL CEILING TO WALL - TRANSVERSE PARTITION TO ROOF PARTITION TO ROOF WITH BLOCKING TRIM END LAP TRIM LAP WITH HEM TRIM END LAP WITH LAP STRIP TRIM LAP AT FRAMED OPENING INDEX SHEET
DISCLAIMERS: THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES. REFRIGERATION EQUIPMENT IN COMBINATION WITH THE TEMPERATURE DIFFERENTIAL BETWEEN BUILDING EXTERIOR AND INTERIOR CAN CREATE NEGATIVE AIR PRESSURE WITHIN THE BUILDING (WARM AIR FROM OUTSIDE THE BUILDING IS DRAWN INTO THE BUILDING THROUGH AIR LEAKS IN THE BUILDING ENVELOPE). AS A RESULT, VAPOR SEALS ARE OF PRIMARY CONCERN TO PROPER COLD STORAGE PERFORMANCE. IN GENERAL, COLD STORAGE FACILITIES REQUIRE THE PRIMARY VAPOR BARRIER TO BE ON THE EXTERIOR (I.E. ), RATHER THAN INTERIOR SIDE OF THE PANEL. PROJECTS LOCATED IN AREAS SUBJECT TO EXTREME COLD AND/OR HIGH SNOW LOADS MAY REQUIRE MODIFICATIONS TO THESE DETAILS - CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT RECOMMENDATIONS. ALL STRUCTURAL SUPPORTS ARE NOT BY KINGSPAN AND ARE SHOWN FOR CLARIFICATION AND ILLUSTRATION PURPOSES ONLY. CONTACT KINGSPAN TECHNICAL SERVICES FOR MAXIMUM ALLOWABLE PANEL SPANS AND FASTENING PATTERNS. ALL SEALANTS TO BE COMPATIBLE WITH VAPOR BARRIERS AS SHOWN COLD STORAGE DISCLAIMER
INTERIOR FACE SHADOWLINE KS42SL 2" - 6" EXTERIOR FACE SHADOWLINE 42" COVERAGE (36", 30", & 24" OPTIONAL) HORIZONTAL SUPPORT MALE LEG FEMALE POCKET 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) CONTINUOUS BUTYL SEALANT (AT "WARM" SIDE JOINT) WALL PANEL INSTALLATION DIRECTION NOTE: FILL FEMALE POCKET(S) 3/4 FULL WITH SEALANT TO PROVIDE PROPER AIR/WATER SEAL KS42SL EXPANDED JOINT
HORIZONTAL SUPPORT MALE JOINT FEMALE JOINT PANEL MODULE 1 8 " 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) CONTINUOUS (AT JOINT) WALL PANEL INSTALLATION DIRECTION KS42SL ENGAGED JOINT
INTERIOR FACE SHADOWLINE KS45SL 2"-6" EXTERIOR FACE SHADOWLINE 45.378" COVERAGE MALE LEG OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) FEMALE POCKET CONTINUOUS BUTYL SEALANT (AT "WARM" SIDE JOINT) WALL PANEL INSTALLATION DIRECTION NOTE: FILL FEMALE POCKET(S) 3/4 FULL WITH SEALANT TO PROVIDE PROPER AIR/WATER SEAL KS45SL EXPANDED JOINT
OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) CONTINUOUS BUTYL SEALANT (AT JOINT) WALL PANEL INSTALLATION DIRECTION KS45SL ENGAGED JOINT
INTERIOR FACE SHADOWLINE KS45 FLAT 2"-6" EXTERIOR FACE FLAT 45.378" COVERAGE MALE LEG OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) FEMALE POCKET CONTINUOUS BUTYL SEALANT (AT "WARM" SIDE JOINT) WALL PANEL INSTALLATION DIRECTION NOTE: FILL FEMALE POCKET(S) 3/4 FULL WITH SEALANT TO PROVIDE PROPER AIR/WATER SEAL KS45 FLAT EXPANDED JOINT
OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) CONTINUOUS BUTYL SEALANT (AT JOINT) WALL PANEL INSTALLATION DIRECTION KS45 FLAT ENGAGED JOINT
OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) INTERIOR OF BUILDING EXTERIOR OF BUILDING CONTINUOUS AT PANEL JOINT 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN 2 1 4 " 1" 3 4 " 2 1 4 " 3 4 " 5 16 " Ø 5 16 " Ø STANDARD: 12 GA. STAINLESS STEEL TWO-HOLE HIDDEN FASTENER CLIP OPTIONAL: 12 GA. STAINLESS STEEL ONE-HOLE HIDDEN FASTENER CLIP NOTE: CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT RECOMMENDATIONS INTERMEDIATE SUPPORT
12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) WARM SIDE LOW PROFILE BOLT W/ WASHER AND LOCK NUT OFFSET BEAM CLIP 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) WARM SIDE LOW PROFILE BOLT W/ WASHER AND LOCK NUT OFFSET BEAM CLIP NOTE: BEAM CLIP TO ALLOW STRUCTURAL STEEL TO DEFLECT W/O PUTTING VERTICAL LOAD INTO WALL PANEL. CONTACT KINGSPAN TECHNICAL SERVICES FOR ADDITIONAL INFO INTERMEDIATE SUPPORT - SLIP CONNECTION
INTERIOR OF BUILDING CONTINUOUS AT PANEL JOINT SHIM AS NECESSARY 1 4 " - 14 HEX HEAD FASTENERS CONCRETE/MASONRY WALL 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) HAT CHANNEL & FASTENING OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) 2 1 4 " 1" 3 4 " 2 1 4 " 3 4 " 5 16 " Ø 5 16 " Ø STANDARD: 12 GA. STAINLESS STEEL TWO-HOLE HIDDEN FASTENER CLIP OPTIONAL: 12 GA. STAINLESS STEEL ONE-HOLE HIDDEN FASTENER CLIP NOTE: CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT RECOMMENDATIONS LINER PANEL TO CONCRETE WITH SUPPORT
INTERIOR OF BUILDING CONTINUOUS AT PANEL JOINT FASTENERS TO MASONRY CONCRETE/MASONRY WALL 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SLIP SHEET TO PROTECT PANELS OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) 2 1 4 " 1" 3 4 " 2 1 4 " 3 4 " 5 16 " Ø 5 16 " Ø STANDARD: 12 GA. STAINLESS STEEL TWO-HOLE HIDDEN FASTENER CLIP OPTIONAL: 12 GA. STAINLESS STEEL ONE-HOLE HIDDEN FASTENER CLIP NOTE: CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT RECOMMENDATIONS LINER PANEL TO CONCRETE
SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN ) SLIP SHEET TO PROTECT PANELS F.I.P INSULATION FIELD CUT THERMAL BREAK 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN "Z" TRIM 2 BEADS OF ON EACH SIDE "Z" TRIM CONCRETE CURB LAP TRIM MIN. 3" TRIM LAP SET PANEL IN CONT. HEAVY BEAD W/ MARRIAGE BEAD TO EXT. PANEL JOINT CONCRETE SLAB BASE TRIM POP RIVETS CONTINUOUS "Z" TRIM SET IN (SEE LAP TRIM ABOVE FOR "Z" TRIM) HEAVY GA. BASE ANGLE CONTINUOUS HEAVY BEAD OF FLOOR INSULATION SUB SLAB FASTENER TO CONCRETE VAPOR BARRIER NOTES: 1) BASE ANGLE MUST BE FASTENED SECURELY TO SLAB TO RESIST LATERAL LOAD APPLIED BY PANEL 2) BASE ANGLE GAUGE TO BE DETERMINED BY PROJECT ENGINEER OF RECORD 3) FLOOR INSULATION REQUIRED FOR FREEZER APPLICATIONS BASE DETAIL - INSULATED SLAB HEAVY GAUGE ANGLE
SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN ) SLIP SHEET TO PROTECT PANELS LAP TRIM 2 BEADS OF ON EACH SIDE F.I.P INSULATION FIELD CUT THERMAL BREAK "Z" ANGLE LAP TRIM 3" END LAP 3" END LAP 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN SET PANEL IN CONT. HEAVY BEAD W/ MARRIAGE BEAD TO EXT. PANEL JOINT BASE TRIM CONCRETE CURB CONCRETE SLAB POP RIVETS "Z" SHAPED BASE ANGLE FLOOR INSULATION SUB SLAB CONTINUOUS HEAVY BEAD OF FASTENER TO CONCRETE VAPOR BARRIER SEE LAP TRIM ABOVE FOR "Z" BASE ANGLE NOTES: 1) BASE ANGLE MUST BE FASTENED SECURELY TO SLAB TO RESIST LATERAL LOAD APPLIED BY PANEL 2) Z SHAPED BASE ANGLE GAUGE TO BE DETERMINED BY PROJECT ENGINEER OF RECORD 3) FLOOR INSULATION REQUIRED FOR FREEZER APPLICATIONS BASE DETAIL - INSULATED SLAB LIGHT GAUGE Z
OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN ) MIN. 16 GA. GALVANIZED BASE ANGLE CONTINUOUS AT PANEL JOINT CONTINUOUS WITH MARRIAGE BEAD TO SEALANT AT PANEL JOINT MIN. 16 GA. GALVANIZED BASE ANGLE FASTENER TO CONCRETE CONCRETE SLAB FASTENER TO CONCRETE (OPTIONAL) FLOOR INSULATION VAPOR BARRIER BASE DETAIL - PARTITION W/ FLOOR INSULATION
CONTINUOUS AT PANEL JOINT SLIP SHEET TO PROTECT PANELS OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN ) CONCRETE CURB CONCRETE CURB F.I.P INSULATION CONCRETE SLAB FIELD CUT THERMAL BREAK FINISH FLOOR SET PANEL IN CONT. HEAVY BEAD W/ MARRIAGE BEAD TO EXT. PANEL JOINT STAGGERED FLOOR INSULATION BASE CHANNEL SUB SLAB CONTINUOUS HEAVY BEAD OF FASTENER TO CONCRETE VAPOR BARRIER NOTES: 1) BASE CHANNEL MUST BE FASTENED SECURELY TO SLAB 2) ANGLE IRON MAY BE USED IN LIEU OF CHANNEL BASE DETAIL - INSULATED/ NON-INSULATED FLOOR
OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN) 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN SLIP SHEET TO PROTECT PANELS CONTINUOUS AT PANEL JOINT 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER ABUSE CURB (NOT BY KINGSPAN - CAN BE POURED AFTER PANEL INSTALLATION) FLOOR INSULATION MIN. 16 GA. GALVANIZED BASE ANGLE FASTENER TO CONCRETE SEALANT MARRIAGE BEAD TO VERTICAL PANEL JOINT VAPOR BARRIER BASE DETAIL - PARTITION W/ CURBS INSULATED FLOOR
CONTINUOUS AT PANEL JOINT OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN) MIN. 16 GA. GALVANIZED BASE ANGLE SEALANT MARRIAGE BEAD TO VERTICAL PANEL JOINT (OPTIONAL) FASTENER TO CONCRETE BASE DETAIL - PARTITION NON-INSULATED FLOOR
BASE TRIM OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN - SEE SCHEDULE) CONTINUOUS AT PANEL JOINT 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER MIN. 16 GA. GALVANIZED BASE ANGLE EXISTING EXTERIOR WALL (OPTIONAL) SEALANT MARRIAGE BEAD TO VERTICAL PANEL JOINT FASTENER TO CONCRETE BASE DETAIL - LINER PANEL
CONTINUOUS AT PANEL JOINT SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN) OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) VAPOR BARRIER ABUSE CURB (NOT BY KINGSPAN - CAN BE POURED AFTER PANEL INSTALLATION) W/ MARRIAGE BEAD SLIP SHEET TO PROTECT PANELS MIN. 16 GA. GALVANIZED BASE CHANNEL FASTENER TO CONCRETE BASE DETAIL - PARTITION W/ CURBS (NON-INSULATED FLOOR)
OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN - SEE SCHEDULE) 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN SLIP SHEET TO PROTECT PANELS CONTINUOUS AT PANEL JOINT 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER ABUSE CURB (NOT BY KINGSPAN - CAN BE POURED AFTER PANEL INSTALLATION) VAPOR BARRIER MIN. 16 GA. GALVANIZED BASE ANGLE FASTENER TO CONCRETE SEALANT MARRIAGE BEAD TO VERTICAL PANEL JOINT BASE DETAIL - PARTITION W/ CURBS (ALTERNATE)
CONTINUOUS AT PANEL JOINT OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) MIN. 16 GA. GALVANIZED BASE CHANNEL SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN) FASTENER TO CONC. CONTINUOUS AT PANEL JOINT SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN) MIN. 16 GA. GALVANIZED BASE ANGLE OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) MIN. 16 GA. GALVANIZED BASE ANGLE FASTENER TO CONC. PARTITION BASE ON TOP OF CURB
WILL VARY WITH FIELD CONDITION WILL VARY WITH FIELD CONDITION FIELD CUT MIN. 1 4" GAP FOR F.I.P. INSTALLATION FIELD CUT THERMAL BREAK F.I.P. INSULATION OUTSIDE CORNER TRIM SELF-ADHERING VAPOR BARRIER (AT - NOT BY KINGSPAN) 1 4 " - 14 "LOW PROFILE" THROUGH FASTENER INSIDE CORNER TRIM POP RIVETS HORIZONTAL SUPPORT OUTSIDE CORNER - FLUSH TRIM
WILL VARY WITH FIELD CONDITION WILL VARY WITH FIELD CONDITION FIELD CUT MIN. 1 4" GAP FOR F.I.P. INSTALLATION FIELD CUT THERMAL BREAK F.I.P. INSULATION OUTSIDE CORNER TRIM SELF-ADHERING VAPOR BARRIER (AT - NOT BY KINGSPAN) INSIDE CORNER TRIM OUTSIDE CORNER AT PARTITION
FASTENER TO CONCRETE OUTSIDE CORNER TRIM (PRE-INSTALL) TRANS FLASHING SELF-ADHERING VAPOR BARRIER (AT - NOT BY KINGSPAN) FIELD CUT THERMAL BREAK F.I.P. INSULATION INSIDE CORNER TRIM OUTSIDE CORNER LINER PANEL AT CONC WALL
WILL VARY WITH FIELD CONDITION WILL VARY WITH FIELD CONDITION FIELD CUT OUTSIDE CORNER TRIM FIELD CUT THERMAL BREAK F.I.P. INSULATION MIN. 1 4" GAP FOR F.I.P. INSTALLATION HORIZONTAL SUPPORT POP RIVETS SELF-ADHERING VAPOR BARRIER INSIDE CORNER TRIM 1 4 " - 14 "LOW PROFILE" THROUGH FASTENER INSIDE CORNER - FLUSH TRIM
INTERIOR EXTERIOR FIELD CUT THERMAL BREAK SELF-ADHERING VAPOR BARRIER INSIDE CORNER TRIM INTERIOR PARTITION F.I.P. INSULATION EXPANSION FASTENER (TO BE LOCATED ON OPPOSITE SIDE OF THERMAL CUT FROM PANEL'S LEADING EDGE) OPTIONAL BUTYL AT WASH DOWN INSIDE CORNER TRIM STRUCTURAL SUPPORT INTERIOR NOTES: 1) ADDITIONAL FASTENERS MAY BE REQUIRED ON EITHER SIDE OF THE FIELD CUT THERMAL BREAK BASED UPON ACTUAL DESIGN LOADS AND THERMAL REQUIREMENTS FIELD FILL WITH INSULATION INSULATE SUPPORTING STEEL ON OF PARTITION (APPROX. 4'-0") FIELD NOTCH PANELS AT GIRT LOCATIONS GIRT CAP TRIM PARTITION TO EXTERIOR WALL
OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) CONTINUOUS AT PANEL JOINT SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN ) FREEZER DOOR CASING, FASTENERS, SEALANT, & REQUIRED SUPPORT SELF ADHERING VAPOR BARRIER (OPTIONAL - NOT BY KINGSPAN) CONTINUOUS WITH MARRIAGE BEAD TO SEALANT AT PANEL JOINT HEADER CONDITION
SEALANT (OPTIONAL - NOT BY KINGSPAN) (INSTALL AFTER TEMP. PULL DOWN ) SELF ADHERING VAPOR BARRIER (OPTIONAL - NOT BY KINGSPAN) FREEZER DOOR CASING, FASTENERS, SEALANT, & REQUIRED SUPPORT CONTINUOUS JAMB CONDITION
FIELD ROUT PANELS FOR WOOD SPLINE BASE TRIM WITH POP RIVETS (PRE-INSTALL WEEP HOLES) CONTINUOUS BUTYL SEALANT FIR SPLINE STACK JOINT TRIM WITH POP RIVETS SET FIR SPLINE IN BUTYL SEALANT CONTINUOUS BUTYL SEALANT MARRIED TO SEALANT IN PANEL JOINT CONTINUOUS AT PANEL JOINT HORIZONTAL SUPPORT 14 GA. GALVANIZED HIDDEN CLIP (1 PER PANEL, PER GIRT) NOTES: 1) SEE DETAIL CS-TL-01-KSV AND CS-TL-02-KSV FOR PROPER TRIM LAP DETAILS 2) CONTACT KINGSPAN TECHNICAL SERVICES FOR PROPER PANEL FASTENING REQUIREMENTS STACK JOINT
GALVANIZED CAP FLASHING ROOF MEMBRANE SYSTEM ATTACHMENT ROOF MEMBRANE BOARD INSULATION AND ROOF UNDERLAYMENT ROOF MEMBRANE SYSTEM ATTACHMENT SEALANT MARRIAGE BEAD TO VERTICAL PANEL JOINT RAKE TRIM, FASTENERS, SEALANT AND WEATHER TIGHTNESS FIELD CUT THERMAL BREAK SHEETING OR RAKE ANGLE REQUIRED F.I.P. INSULATION OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN CONTINUOUS AT PANEL JOINT RAKE
GALVANIZED CAP FLASHING ROOF MEMBRANE ROOF MEMBRANE SYSTEM ATTACHMENT CONT. HEAVY BEAD BUTYL SEALANT W/ MARRIAGE BEAD TO EXT. PANEL JOINT INSULATION AND ROOF UNDERLAYMENT FASTENER RAKE TRIM, FASTENERS, SEALANT AND WEATHER TIGHTNESS SEALANT TO MEMBRANE FIELD CUT THERMAL BREAK F.I.P. INSULATION SHEETING OR RAKE ANGLE REQUIRED 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) RAKE W/ MEMBRANE ROOF
F.I.P. INSULATION GALVANIZED CAP FLASHING ROOF MEMBRANE ROOF MEMBRANE SYSTEM ATTACHMENT CONT. HEAVY BEAD BUTYL SEALANT W/ MARRIAGE BEAD TO EXT. PANEL JOINT INSULATION AND ROOF UNDERLAYMENT FASTENER RAKE TRIM, FASTENERS, SEALANT AND WEATHER TIGHTNESS SEALANT TO MEMBRANE FIELD CUT THERMAL BREAK EAVE STRUT OPTIONAL BUTYL (RECOMMENDED FOR WASHDOWN APPLICATIONS) 1 4 " - 14 HEX HEAD FASTENERS WITHOUT WASHER 12 GA. STAINLESS STEEL HIDDEN FASTENER CLIP (1 PER PANEL, PER SUPPORT) SET CLIP IN CONTINUOUS AT PANEL JOINT LOW EAVE
SEE CS-CE-04-KSV FOR ADDITIONAL INFO FIELD CUT THERMAL BREAK ATTIC ABOVE CEILING MUST BE VENTILATED F.I.P. INSULATION OUTSIDE CORNER TRIM CEILING SELF ADHERING VAPOR BARRIER WALL INSIDE CORNER TRIM CONTINUOUS AT PANEL JOINT INTERIOR WALL TO CEILING
#10 X 1 3 8" FASTENER AT EVERY PANEL JOINT BOTH SIDES OF PANEL AA CROSS SECTION (SECTION VIEW ) FIELD CUT THERMAL BREAK CEILING SUPPORT ANGLE EXPANSION FASTENER COMPRESSIBLE INSULATION A WALL A #10 X 1 3 8" TEK 1 FASTENER AT EVERY PANEL JOINT (SEE DETAIL ABOVE) WALL TO CEILING INTERSECTION
ATTIC ABOVE CEILING MUST BE VENTILATED INSULATE HANGER RODS AS REQUIRED (NOT BY KINGSPAN) 3 8 " GALVANIZED HANGER ALL-THREAD ROD (ROD SPACING TO BE DETERMINED) TRANSITION FLASHING HEX NUT AND LOCK WASHER 4" X 4" X 14 GA. PLATE WASHER* SELF ADHERING VAPOR BARRIER INTERIOR FACE OF PANEL CEILING CEILING FILL 1 2" GAP BETWEEN PANEL WITH F.I.P. INSULATION HEX NUT AND LOCK WASHER EXTERIOR SIDE OF PANEL MUST BE ON BOTTOM OF CEILING. PANEL CUTLIST MUST MATCH THIS ORIENTATION 1 1 2" X 6" X 14 GA. GALVANIZED CEILING CHANNEL (WHITE POWDER COAT - OPTIONAL) (CAP TRIM - OPTIONAL) #8 GA. SPLAY BRACE WIRE IN FOUR DIRECTIONS 3 8 " ALL-THREAD HANGER ROD FOUR TIGHT TURNS IN 1 1 2" SEISMIC BRACE PLATE * CONTACT KINGSPAN TECHNICAL SERVICES FOR SEISMIC BRACE PLATE QUANTITY AND LOCATION SEISMIC BRACE PLATE CEILING CHANNEL
ATTIC ABOVE CEILING MUST BE VENTILATED 3 8 " GALVANIZED HANGER ALL-THREAD ROD (SPACED NO GREATER THAN 6'-0" O.C.) TRANSITION FLASHING INSULATE HANGER RODS AS REQUIRED (NOT BY KINGSPAN) HEX NUT AND LOCK WASHER 4" X 4" X 14 GA. PLATE WASHER* SELF-ADHERING VAPOR BARRIER INTERIOR FACE OF PANEL CEILING CEILING EXTERIOR SIDE OF PANEL MUST BE ON BOTTOM OF CEILING. PANEL CUTLIST MUST MATCH THIS ORIENTATION 4" X 3" X 3 16" EXTRUDED ALUMINUM CEILING TEE (WHITE POWDER COAT FINISH) FILL 1 2" GAP BETWEEN PANEL WITH F.I.P. INSULATION 3 8 "Ø EYE COUPLER NUT 3 8 "Ø x 1 1 2" BOLT WITH (3) 3 8 " WASHERS AND (1) LOCK-NUT PER BOLT #8 GA. SPLAY BRACE WIRE IN FOUR DIRECTIONS 3 8 " ALL-THREAD HANGER ROD FOUR TIGHT TURNS IN 1 1 2" SEISMIC BRACE PLATE * CONTACT KINGSPAN TECHNICAL SERVICES FOR SEISMIC BRACE PLATE QUANTITY AND LOCATION SEISMIC BRACE PLATE CEILING TEE
SEISMIC BRACE PLATE (IF REQUIRED) TO BE LOCATED AT EVERY THIRD ROD LOCATION IN LIEU OF PLATE WASHER (SEE DETAIL CS-CE-04-KSV). CONTACT KINGSPAN TECHNICAL SERVICES FOR VERIFICATION. OUTSIDE CORNER TRIM WITH @ 12" OC. (SEALANT OR VAPOR SEAL TAPE AS REQUIRED) SEE DETAIL CS-CE-01-KSV FOR ADD'L INFO. PROJECT ENGINEER OF RECORD MUST VERIFY ROOF IS CAPABLE OF SUPPORTING CEILING SYSTEM LOADS AS WELL AS PROPER CEILING TO ROOF CONNECTION DETAILS LOCATE FIRST HANGER ROD AT LESS THAN 24" FROM FACE OF PANEL ERECTOR MAY PRE-ASSEMBLE HARDWARE ON 3 8" HANGAR RODS- WIRE TIES HOLD WASHERS ABOVE WORKING POINT CEILING TEE HEX NUT ROUND WSHR SPLICE PLATE 4" X 4" X 14 GA. PLATE WASHER WIRE TIE INTERIOR FACE OF PANEL CEILING TEE CEILING TEE SPLICE PLATE W/ (4) 3 8" X 1 1 2" BOLTS, NUTS, AND WASHERS EXTERIOR SIDE OF PANEL MUST BE ON BOTTOM OF CEILING. PANEL CUTLIST MUST MATCH THIS ORIENTATION CEILING TEE ASSEMBLY
PROJECT ENGINEER OF RECORD MUST VERIFY ROOF IS CAPABLE OF SUPPORTING CEILING SYSTEM LOADS AS WELL AS PROPER CEILING TO ROOF CONNECTION DETAILS FIELD NOTCH END OF CHANNEL TO REST ON TOP OF WALL PANEL NUT ROUND WSHR ERECTOR MAY PRE-ASSEMBLE HARDWARE ON 3/8" HANGER RODS- WIRE TIES HOLD WASHERS ABOVE WORKING POINT 4" X 4" X 14 GA. PLATE WASHER WIRE TIE 2'-0" MAX. INTERIOR FACE OF PANEL SPLICE PLATE CEILING CHANNEL 9/16" DIA. HOLES PRE-PUNCHED FOR 3/8" OR ALL-THREAD ROD AT 5'-0" O/C (DO NOT SPACE ALL-THREAD RODS FURTHER THAN 60" APART. THE SPAN FROM WALL TO FIRST ROD, SHALL BE NO GREATER THAN 24".) EXTERIOR SIDE OF PANEL MUST BE ON BOTTOM OF CEILING. PANEL CUTLIST MUST MATCH THIS ORIENTATION CEILING CHANNEL ASSEMBLY
ATTIC ABOVE CEILING MUST BE VENTILATED INSIDE CORNER TRIM FIELD CUT THERMAL BREAK F.I.P. INSULATION EXPANSION FASTENER CEILING CONTINUOUS BUTYL SEALANT AT "WARM" SIDE PANEL JOINT SUPPORT ANGLE NOTE: CONTACT KINGSPAN TECHNICAL SERVICES FOR ENGINEERING ASSISTANCE CEILING TO WALL - LONGITUDINAL
ATTIC ABOVE CEILING MUST BE VENTILATED 3 8 " GALVANIZED HANGER ALL-THREAD ROD (ROD SPACING TO BE DETERMINED) INSIDE CORNER TRIM 1 4 " MAX DISTANCE BETWEEN PANEL EDGE AND THREAD ROD FIELD CUT THERMAL BREAK F.I.P. INSULATION EXPANSION FASTENER CEILING CONTINUOUS BUTYL SEALANT AT "WARM" SIDE PANEL JOINT 16 GA. SUPPORT ANGLE HEX NUT AND LOCK WASHER NOTE: CONTACT KINGSPAN TECHNICAL SERVICES FOR ENGINEERING ASSISTANCE CEILING TO WALL - TRANSVERSE
A EXPANSION FASTENERS AS REQUIRED COMPRESSIBLE INSULATION SUPPORT ANGLE (SET IN ) #10 X 1 3 8" TEK 1 FASTENER AT EVERY PANEL JOINT A PARTITION TO ROOF (PERPENDICULAR TO PURLIN) FIELD FILL WITH INSULATION FIELD NOTCH PANELS AT PURLIN LOCATIONS KINGSPAN TO SUPPLY FLAT-STOCK SHEETING TO BE FIELD FORMED FOR PANEL CLOSURES COMPRESSIBLE INSULATION PURLIN AA CROSS SECTION (SECTION VIEW -- TYPICAL AT EACH PURLIN) PARTITION TO ROOF
FILL VOIDS WITH FOAM BLOCK, SET IN FIELD CUT PANELS AS REQUIRED 1/4"-14 STITCH TEKS AT EACH PURLIN PURLIN CLOSURE TRIM TO BE FIELD CUT TO FIT AT PURLIN FLANGES. USE SILICONE TO SEAL ALL EDGES WHEN COMPLETE. 1/4"-14 STITCH TEKS AT EACH PURLIN SUPPORT ANGLE (SET IN ) ATTACH PURLIN CLOSURES W/ POP RIVETS COMPRESSIBLE INSULATION PARTITION TO ROOF (WITH FOAM BLOCKING) (PERPENDICULAR TO PURLIN) #10 X 1 3 8" TEK 1 FASTENER AT EVERY PANEL JOINT FIELD CUT CONTINUOUS THERMAL BREAK (FREEZER ONLY) COMPRESSIBLE INSULATION EXPANSION FASTENERS AS REQUIRED SUPPORT ANGLE SET IN PARTITION TO ROOF (PARALLEL TO PURLIN) #10 X 1 3 8" TEK 1 FASTENER AT EVERY PANEL JOINT PARTITION TO ROOF WITH BLOCKING
(2) BEADS MIN. 3" TRIM LAP MIN. 3" TRIM LAP TRIM END LAP
FIELD NOTCH HEM(S) AS REQUIRED MIN. 3" TRIM LAP (2) BEADS MIN. 3" TRIM LAP TRIM LAP WITH HEM
(2) BEADS 8" LONG LAP STRIP NOM. 1 4 " GAP TRIM END LAP WITH LAP STRIP
NOTE: DETAIL SHOWN IS FOR GENERAL USE ONLY (NOT FOR COOLER/FREEZER APPLICATIONS). SEALANT END DAM 2 INTERIOR HEAD TRIM WITH TABS BENT DOWN FIELD NOTCH AND OVERLAP TRIMS, POP RIVET AND SEAL AS NECESSARY FIELD MITER AND OVERLAP TRIMS, POP RIVET AS NECESSARY INTERIOR CAP TRIM AT HEAD EXPOSED SEALANT EXTERIOR CAP TRIM AT HEAD 5 EXTERIOR HEAD TRIM W/ FIELD DRILL 3 8" Ø WEEP HOLES INTERIOR JAMB TRIM 1 SILL TRIM WITH TABS BENT UP 6 3 EXTERIOR CAP TRIM AT JAMB FIELD CUT/NOTCH CAP TRIM AT CORNERS TO ALLOW FOR LAP 4 EXTERIOR JAMB TRIM FIELD CUT/NOTCH CAP TRIM AT CORNERS TO ALLOW FOR LAP EXTERIOR CAP TRIM AT SILL FIELD MITER AND OVERLAP TRIMS, POP RIVET AND SEAL AS NECESSARY TRIM INSTALLATION SEQUENCE: 1 INTERIOR JAMB TRIM 2 INTERIOR HEAD TRIM WITH TABS DOWN 3 SILL TRIM WITH TABS UP 4 EXTERIOR JAMB TRIM 5 EXTERIOR HEAD TRIM 6 EXTERIOR SEALANTS AS REQUIRED TRIM LAP AT FRAMED OPENING