CL55C CLICK ANALYSER The cost competitive, PC-driven, automatic, multi-channel discontinuous interference analyser

Similar documents
DDA55 DISCONTINUOUS DISTURBANCES ANALYSER

ER55 EMI TEST RECEIVER Family of automatic test receivers for measurement of electromagnetic interference from 9kHz to 2.8GHz.

Advanced Test Equipment Rentals ATEC (2832)

FFT 3010 EMI TEST RECEIVER

ER55 EMI TEST RECEIVER Family of automatic test receivers for measurement of electromagnetic interference from 9kHz to 1GHz

INTRODUCTION TO CONDUCTED EMISSION

Conducted emission pre compliance measurements

Keysight Technologies Essential Capabilities of EMI Receivers. Application Note

Conducted emission pre compliance measurements

Essential Capabilities of EMI Receivers. Application Note

PMM 7010 EMI RECEIVERS. The EMI Receiver with built-in LISN

EMC standards. Presented by: Karim Loukil & Kaïs Siala

Specification for Conducted Emission Test

DSI-600 EMI Test & Measurement Receiver

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

Chambers Accessories Equipment 1 Equipment 2 Amplifiers Antennas Emission

TEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD.

Spectrum Analyzers 2680 Series Features & benefits

EMC / FIELD STRENGTH Test receivers. Fast and straightforward: diagnostic and precompliance measurements with the R&S ESRP

Appendix A: Specifications

R3477. Ideal for mobile communication applications including base stations and handsets, from the development stage to production and installation

Federal Communications Commission Office of Engineering and Technology Laboratory Division

A Study of Conducted-Emission Stable Source Applied to the EMC US and EU Standards

DSA700 Series Spectrum Analyzer

3250 Series Spectrum Analyzer

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009

Spectrum Analyzers U3771/3772. Handling frequencies of up to 43 GHz!! Our new microwave spectrum analyzer, ideal for field use, is now available.

Guide on Implementation of Requirements of the Common EPS

EMI T E S T R E P O R T

khz to 2.9 GHz Spectrum Analyzer

Measurement of conducted EMI when using a switching power supply

7. Transmitter Radiated Spurious Emissions and Conducted Spurious Emission

2620 Modular Measurement and Control System

DSA800. No.1 RIGOL TECHNOLOGIES, INC.

Dynamic Sciences International, Inc. Detection with Direction

Ave output power ANT 1(dBm) Ave output power ANT 2 (dbm)

Advanced Test Equipment Rentals ATEC (2832)

Spectrum Analyzer R&S FS300

Nemko-CCL, Inc West Alexander Street Salt Lake City, UT

EMI T E S T R E P O R T

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011

Fast network analyzers also for balanced measurements

EMI Test Receivers ESHS

Two Line V-Network GLN-5040A USER MANUAL GW INSTEK PART NO. 99 Washington Street Melrose, MA Phone Toll Free

AC Wire Carrier Current Devices (Unintentional Radiators)

EMC VERIFICATION SUMMARY Report No.: SZHH

N acquisitions, all channels simultaneously, N is selectable from 4, 16, 64, and 128 Inputs

Vector Network Analyzers ZVB

TT7000R4. DS Instruments. D text. RF Power Meter, Signal Generator, Frequency Counter. -Key Features-

EMC Test Report. Report Number: M030826

V1.3. TBLC08 50mH AC-LISN TBLC08

TEST REPORT. For RFID READER/WRITER. In conformity with. FCC CFR 47 Part15 Subpart C

Trees, vegetation, buildings etc.

Demo / Application Guide for DSA815(-TG) / DSA1000 Series

R&S ZVT Vector Network Analyzer Specifications

ELECTRONICS TESTING CENTER, TAIWAN

Ideal for high dynamic range measurements from compression to noise floor

Willtek. Handheld Spectrum Analyzer

EN V1.1.1 ( )

TEST REPORT FROM RFI GLOBAL SERVICES LTD

EMC Bayswater Pty Ltd. EMC COMPLIANCE REPORT In accordance with: AS/NZS CISPR 15: Indice Ecotech Pty Ltd. 14W LED Downlight

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

Timing Considerations Using FFT-based Measuring Receivers for EMI Compliance Measurements

VCCI TEST REPORT. According to. Class B ITE. Equipment : USB video camera

In late 2011, The International Standards

RF Emissions Test Report To Determine Compliance With: FCC, Part 15 Rules and Regulations

Electromagnetic Compatibility Test Report FCC test results of an automatic dog brush, model EUT: Type 1 AC/DC adaptor: SYS W2E

TEST REPORT... 1 CONTENT...

TETRA Tx Test Solution

MDS-21 Absorbing Clamp, EZ-24 Ferrite Clamp

Chapter 5 Specifications

FCC CLASS B COMPLIANCE REPORT (DoC)

No. 620 HuaYuan Commercial Center, No. 347 XiXiang Road,XiXiang Town, Bao An District, ShenZhen City Tel : Fax:

A Test Lab Techno Corp. Report Number:1410FR27

To «Test_Standards» Test of: Radwin Ltd. Outdoor Subscriber Radio Unit. To: FCC CFR 47 Part 15B; ICES-003 Issue 6: 2016

TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCES EMITTED FROM LIGHTING EQUIPMENT INSTALLED IN TELECOMMUNICATION CENTERS

TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCE EMITTED FROM TELECOMMUNICATIONS EQUIPMENT

CS114 + CS115 + CS116

Standalone High Accuracy Transformer Analysis. Basic 0.02dB with class leading high frequency performance. RS232, USB and LAN as standard

TBM - Tone Burst Measurement (CEA 2010)

Verification Test Report

TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCE EMITTED FROM TELECOMMUNICATIONS EQUIPMENT

EMI -- T E S T R E P O R T

The Value of Pre-Selection in EMC Testing. Scott Niemiec Application Engineer

MultiMaster. Base Station Test Tools. Multi Purpose Base Station Tester. Introduction. Feature

Spectrum Analyzers. 2394A 1 khz to 13.2 GHz Spectrum Analyzer.

SC5407A/SC5408A 100 khz to 6 GHz RF Upconverter. Datasheet. Rev SignalCore, Inc.

VCCI TEST REPORT. According to. V-3/ , TECHNICAL REQUIREMENTS, Class B ITE. Equipment : USB video camera. Model No. : V-U0017 / V-U0021

TEST REPORT. Table of Contents

Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)

RF test report AU01+W02

Return Loss Bridge Basics

Training Course on Conformity and Interoperability, Tunis-Tunisia, from 14 to 18 December EMC standards

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

Agilent ESA-L Series Spectrum Analyzers

Training Course on Conformity and Interoperability, Tunis-Tunisia, from 11 to 15 April EMC standards

SIGNAL GENERATORS. MG3633A 10 khz to 2700 MHz SYNTHESIZED SIGNAL GENERATOR GPIB

IQgig-IF TM Technical Specifications

Spectrum Analyzer RIGOL TECHNOLOGIES,INC.

Transcription:

CL55C CLICK ANALYSER The cost competitive, PC-driven, automatic, multi-channel discontinuous interference analyser According to CISPR 14-1, Designed in compliance with CISPR 16-1, Advanced software for totally automatic operation, Multi-window realtime display of, Time-domain display, Built-in impulse generator

CL55C is the cost competitive, PC-driven, automatic, multichannel discontinuous interference analyser CL55C is not just a GO/NO-GO tester. It is a sophisticated analyser fully supporting a thorough investigation on the when, where and why a click occurs. CL55C so provide a very substantial contribution to problem-solving requirements in a critical domain of equipment compliance. OVERVIEW CISPR 14-1 describe limits for phenomena related to unwanted radio emissions from household appliances and portable tools, including the discontinuous disturbances on the mains cord, the so-called "clicks". DEFINITIONS A discontinuous disturbance, commonly called "click", is defined as a disturbance exceeding the limit of continuous emission for no longer than 200ms, and that is separated from a subsequent disturbance by at least 200ms. All automatic, programmedcontrolled machines, electrically operated and thermal appliances, and common domestic and light-industry equipment, generate discontinuous disturbances along the power supply cabling. The effects of such disturbances vary with repetition rate and amplitude: the higher the amplitude of the disturbance, the lower should be its frequency of occurrence. APPLICABLE STANDARDS For clicks - that is for interference emissions that exceed the recognized steady-state limits but for a very limited time - CISPR14-1 has been and is used as the basic standard for short-term emissions as well as a product standard. It is a quoted as a basic reference in the generic standards IEC 61000-6-3 for residential and light industrial limits and IEC 61000-6-4 for industrial environments. Likewise it is referenced in product standard EN55103 for professional audio/video equipment. Such requirement is a timeconsuming test, that may take several hours per each phase of the EUT (Equipment Under Test). Thanks to the independence and simultaneous operation of its channels, the AFJ CL55C greatly reduces the test time required. CISPR COMPLIANCE CL55C is a four, parallel channel, fixed frequency (150KHz, 500KHz, 1.4MHz, 30MHz) RF receiver, with each channel provided with peak and quasi-peak detectors. Q-P detectors, fully comply with CISPR16-1. The way the Q-P detectors are designed, enables to automatically perform tests in full compliance with the requirements of EN55014-1, where requesting to test using an oscilloscope (time-domain operation). For the purpose of functional selfassessment, the analyser has a builtin impulse generator, that can produce the entire set of single and multiple disturbance pulses, in the various timing and shift configurations, as required by CISPR 16-1. Powerful and user-friendly control software enables it to perform all tests, standard and customized, in a very easy and fully automatic way. Option CL55/VCCI, makes the click analyser fully compliance with VCCI Emission Japanese standard, by through 500kHz / 550kHz selectable frequencies.

An host PC is connected to AFJ CL55C via highspeed parallel port, enabling the analyzer to be used for automatic test set up and running, and for consistent report generation. The PC totally controls the analyzer through a friendly application S/W, running under the WINDOWS 95/98/2000/NT. The S/W enables the operator to set all parameters, setting up the analyzer according to CISPR 14-1 requirements, or any other specific needs. The CL55C main characteristic, is its ability to sample, in parallel, the peak and quasi-peak levels of the four channels, to recognize and count all clicks (short, long, continuous noise and switching operations), and store all numeric and graphic data, like waveforms, in the PC hard disk. The PC-based operation of the analyzer, means practically unlimited memory capabilities, and the ability to generate assisted, or fully-automatic test reports. CL55C is not just a GO/NO- All information collected by the AFJ CL55C during the test, are displayed in real time on the PC screen, divided into a number of windows corresponding to the number of internal RF channels. Finally, the real superiority of the analyser, resides in the built-in power meters, enabling the continuous monitoring of EUT current consumption: in fact, steep variations in this current are often related with disturbances (click) because of the very large bandwidth, that includes all frequencies able to generate a click. GO tester, but a sophisticated analyser fully supporting a thorough investigation on the when, where and why a click occurs, so providing a very substantial contribution to problem-solving requirements in a critical domain of equipment compliance.

Built-in impulse generator For the purpose of functional selfassessment, the analyser has a built-in impulse generator, that can produce the entire set of single and multiple disturbance pulses, in the various timing and shift configurations, as required by Clause 14, Tables 14, 15 and 16 of CISPR 16-1. A powerful, and userfriendly control software, enables to perform all tests, standard and customised, in a very easy and fully automatic way. CL55C / IF CL55C/IF is the discontinuous disturbances analyser, which is intended to be used tuned to the IF output frequency of any EMI receiver provided with Quasi Peak detector. CL55 software allows the user to control the CL55/IF operations, giving the possibility to store, analyse and report all the measurements. CL55C/IF still remain a true analyser system..

ANALYSE Fast overview clicks analysis. Disturbance class selection (short clicks, long clicks, continuous), is available through the green, yellow, red boxes on the right side of the panel. Any mix of the desired selection, is allowed. The timescale can be adapted to the display requirements, through the Scale menu window. ZOOM ANALYSE, shows: - Click Peak level curve - Click Quasi Peak level curve - Limit level - EUT Current X and Y-axes shall be adjusted through appropriate commands on the right-low side. LEVEL ANALYSE, shows EUT switching operations, supply current and click events level.

END OF TEST By the time limit in minutes: TIME LIMIT (min) If the continuous disturbances exceed a set time value: TIME LIMIT FOR CONTINUOUS INTERFERENCE TIME (ms) If a set maximum number of clicks are reached: Total Click number. HARDWARE SETTINGS: For each of the four channels, the IF threshold level, in dbµv, that must be exceeded to detect a signal. SELF CALIBRATION Routine INTERNAL ATTENUATION Level can be set for each channel REMOTE: select the appropriate LISN EXTERNAL ATTENUATION & OFFSET MODE SETTINGS: allows the programming of the Analyser according to one of the two operating modes: Click Sense, defines a mode where the Analyser counts clicks only, and not the switching operations Click Sense + SW Operation defines a mode where the Analyser counts both clicks, and switching operations. CISPR MODE, the most widely used mode: Analyser acquires and recognises the disturbances only when both the Peak (IF) and Quasi Peak detectors exceed the set threshold. In case the CISPR mode is non-selected, any IF signal that is measured exceeding the set threshold by the Peak detector is recorded. This function, may be very useful during the debugging stage of a device, since allows to understand how a click may turn into a continuous disturbance, or how it may affect the Presence of another click. CISPR 14-1 2000 Or CISPR 14 1997 SWITCHING OPERATION SETTINGS The Current (A) parameter, allows setting the minimum value of the DUT current change, suitable for the detection of a switch. The Filter Time Const. (s) allows setting the filter time constant; in order to avoid that unwanted switching operations are detected.

In connection with such an outstanding graphic capability, a complete reporting environment is made available, allowing text files generation as well as bitmap images. In the time-domain graph, the level of the click is readily appreciated: if just above the limit, it s likely to be easily removed. When the disturbance level is very high, the corrective procedure should trade between reducing total click count working on low- level clicks, or exploiting the relative influence of each click on the overall disturbance spectrum, to bring the EUT within limits. In this respect, the functionalities supported by CL55C are of highest effectiveness. Once all appropriate actions have been taken, the EUT will be tested again, results will be compared and a consistent test report will be edited. MEASUREMENT SEQUENCE USING CL55C 1. Perform the test on the EUT according to applicable standards (CISPR 14-1) SECOND PASS PREVIEW AFJ CL55C usage, greatly reduce the measurement time thanks to unique internal SW function, called Second Pass preview. Let s assume that the first test has been finished with the following results (steps a f): First Run a. Determine N by clicks or by switching operation number; b. Runs for 120mins or until 40 clicks (or 40 switching) have been registered; c. Calculates click rate N from Number of clicks/time in minutes; d. Registers where N>30; e. Registers where all clicks 20ms and 90% 10ms (Instantaneous Switching); f. Registers where N 5; g. Calculates Lq from 20log30/N + L; Second Run h. Runs test again, using the click rate information; i. Applies L or Lq as necessary; j. Applies Upper Quartile Method where appropriate or L=Lq+44dB; k. Give Pass/Fail Information; l. Generates Test Report including table of each click measured, timing information and amplitude information, limits, etc. 2. If the EUT test fails, open the analyse window and, 3. Examine each click event together with the EUT cycle description. 150kHz channel shows 10 clicks, of which 7 are lower than 10ms (instantaneous), and 3 are longer than 10ms. Channel demands the calculation of a new limit, Lq (step g). 500kHz channel shows 7 clicks, plus a 220ms continuous disturbance. Channel, according to EN55014 Par. 4.2.3.2, shall consider the whole endurance of all such disturbance as a single click, since lower than 600ms. 1.4MHz channel shows 5 instantaneous clicks, (<10ms). N value must be taken into account, to ascertain we have to calculate a new limit. 30MHz channel, shows no clicks, and therefore fully complies with Standard.

To automatically obtain final result without Second test running, select the Click Rate box in the 2 nd Pass Preview: the N-rate according to Par. 7.4.2.2 of EN55014 is calculated, per each channel. SW controls the previously stored Quasi-Peak levels, comparing them versus the new limits, and providing a report on how many of the old clicks are overriding the new limits, thus yielding an immediate and automatic PASS-FAIL output (steps g l). It shall be possible avoid the second run test, saving 50% of measurement time. How to avoid the second run test, saving up 50% of measurement time! SECOND PASS PREVIEW The preview result for the DUT second test is: 150kHz channel: New limit set at 81.6dBµV, allowed click number: 2. Pass. 500kHz channel: After converting the continuous disturbance <600ms (note below), N has been recalculated, and therefore the new limit is set at 73.6dBµV. allowed click number: 2. Pass. 1.4 MHz channel: Exempt from limits, since subject to instantaneous disturbance, and N<5. 30 MHz channel: No clicks

No. of Receivers Four Internal Receiver Tuned Frequencies 150kHz, 500kHz, 1.4MHz, 30MHz Frequency Error <10x10-6 Pulse Reponse Peak and Quasi-Peak conforming to CISPR 16-1 Impulse Generator Built-in, CISPR 16-1 compliant RF Input BNC Female 50 ohm VSWR Input 0dB Att.: With Att.: Max Input Built-in Attenuator Sensitivity Intermediate Frequency RF Shielding Noise Floor Measuring Error Test Time Limit Display Measure Level Image Freq. Rejection Information Displayed for each channel Displayed Level Displayed Events PC requirements Interface Power Supply, Consumption Operating Temperature, Storage Temperature Dimension (HxWxD, mm), Weight <1,5:1 <1,2:1 127dBµV manual 0 65dB (5dB/Step) 25dBµV 455 khz 3V/m <25dBµV ± 1.5dBmax 999 minutes 0 to 120dBµV 85dB Typ. 0 120dBµV No. of clicks: short, long Discontinuous interference Elapsed test time No. of switching operations Continuous Disturbance Time Time Domain Test Report Graphic Editor IBM PC High speed parallel port 110/230V, 50/60Hz, 50VA 0 45 C, -20 70 C 136x450x436, 15 Kg ORDERING INFORMATION AFJ International Via Alessandro Algardi 13 20148 Milano Phone: +39 02 89 15 91 40 Fax: +39 02 89 15 92 26 sales@afj.it www.afj.it Version 08 October 2008. Subject to change without notice.