X-ray detectors in healthcare and their applications

Similar documents
10/26/2015. Study Harder

10/3/2012. Study Harder

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Setting up digital imaging department!

Radiology Physics Lectures: Digital Radiography. Digital Radiography. D. J. Hall, Ph.D. x20893

Current technology in digital image production (CR/DR and other modalities) Jaroonroj Wongnil 25 Mar 2016

Chromatic X-Ray imaging with a fine pitch CdTe sensor coupled to a large area photon counting pixel ASIC

The Medipix3 Prototype, a Pixel Readout Chip Working in Single Photon Counting Mode with Improved Spectrometric Performance

X-Ray Medical Imaging and Pixel detectors

DALLA LUCE VISIBILE AI RAGGI X: NUOVI RIVELATORI DI IMMAGINI PER RAGGI X A DISCRIMINAZIONE IN ENERGIA ED APPLICAZIONI

NOT FOR DISTRIBUTION JINST_128P_1010 v2

Unit thickness. Unit area. σ = NΔX = ΔI / I 0

GE Healthcare. Senographe 2000D Full-field digital mammography system

COMPUTED TOMOGRAPHY 1

SECTION I - CHAPTER 1 DIGITAL RADIOGRAPHY: AN OVERVIEW OF THE TEXT. Exam Content Specifications 8/22/2012 RADT 3463 COMPUTERIZED IMAGING

Amorphous Selenium Direct Radiography for Industrial Imaging

Do you have any other questions? Please call us at (Toll Free) or , or

Basis of Computed Radiography & PACS

PIXSCAN CT scanner for Small Animal Imaging Based on hybrid pixel detectors

Real Time Linear Array Imaging. Brian Caccamise

Marten Bosma 1, Alex Fauler 2, Michael Fiederle 2 en Jan Visser Nikhef, Amsterdam, The Netherlands 2. FMF, Freiburg, Germany

Breast Tomosynthesis. Bob Liu, Ph.D. Department of Radiology Massachusetts General Hospital And Harvard Medical School

Mammography Solution. AMULET Innovality. The new leader in the AMULET series. Tomosynthesis, 3D mammography and biopsy are all available.

Color X-ray photon counting image sensor

Mammography: Physics of Imaging

Photon Counting and Energy Discriminating X-Ray Detectors - Benefits and Applications

Charged Coupled Device (CCD) S.Vidhya

Advances in Computed Tomography and Digital Mammography Ruvin Deych and Sorin Marcovici Analogic Corporation Peabody, MA 01960, USA

10/15/2012 SECTION III - CHAPTER 6 DIGITAL FLUOROSCOPY RADT 3463 COMPUTERIZED IMAGING

Acceptance Testing of a Digital Breast Tomosynthesis Unit

PIXSCAN CT-scanner for Small Animal Imaging Based on hybrid pixel detectors

High Energy Digital Radiography & 3D-CT for Industrial Systems

Electronic Instrumentation for Radiation Detection Systems

SmartRAD. Advanced Digital Radiography System

I. PERFORMANCE OF X-RAY PRODUCTION COMPONENTS FLUOROSCOPIC ACCEPTANCE TESTING: TEST PROCEDURES & PERFORMANCE CRITERIA

Single Photon X-Ray Imaging with Si- and CdTe-Sensors

Advances in High Energy X-ray Digital Detector Arrays

Strip Detectors. Principal: Silicon strip detector. Ingrid--MariaGregor,SemiconductorsasParticleDetectors. metallization (Al) p +--strips

DIGITAL IMAGE PROCESSING IN X-RAY IMAGING

Designing an MR compatible Time of Flight PET Detector Floris Jansen, PhD, Chief Engineer GE Healthcare

Small Animal Radiographic Techniques and Positioning COPYRIGHTED MATERIAL

Detector technology in simultaneous spectral imaging

Muon detection in security applications and monolithic active pixel sensors

LARGE FORMATTED AND HIGH RESOLUTION CMOS FLAT PANEL SENSORS FOR X-RAY

PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY

2D, 3D CT Intervention, and CT Fluoroscopy

BASICS OF FLUOROSCOPY

Predicted image quality of a CMOS APS X-ray detector across a range of mammographic beam qualities

Fundamentals of CMOS Image Sensors

Digital Image Management: the Basics

CR Basics and FAQ. Overview. Historical Perspective

Hardware for High Energy Applications 30 October 2009

STATUS AND PROSPECTS OF DIGITAL DETECTOR TECHNOLOGY FOR CR AND DR Ulrich Neitzel Philips Medical Systems, Röntgenstrasse 24, D Hamburg, Germany

Digital Industrial Radiography

X-ray light valve (XLV): a novel detectors technology for digital mammography*

Modeling detector performance in digital mammography using the linear cascaded systems approach

New spectral benefi ts, proven low dose

Pixel hybrid photon detectors

Seminar 8. Radiology S8 1

VOLUMETRIC computed tomography (CT) based on flatpanel

Fluoroscopy - Chapter 9

Flat Panel Detectors in Industrial Radiography

Detectors that cover a dynamic range of more than 1 million in several dimensions

Radiographic sensitivity improved by optimized high resolution X -ray detector design.

Applications of a Pixellated Detection System to Digital Mammography

Philips XPER FD10C R7.0.4

Quality Control of Full Field Digital Mammography Units

Tomographic 3D-Radiometry for the Visualisation and Measurement of the Defects of Girth Seams

Some Essential Physics of Flat-Panel Detectors

AN ABSTRACT OF THE THESIS OF. W. Scott Helms for the degree of Master of Science in Radiation Health Physics

Multi-Access Biplane Lab

Digital Detector Array Image Quality for Various GOS Scintillators

Estimation of signal transfer property for wireless digital detector in different measurement schemes

Simulation of High Resistivity (CMOS) Pixels

Gamma Spectrometer Initial Project Proposal

Research Support. Dual-Source CT: What is it and How Do I Test it? Cynthia H. McCollough, Ph.D.

Features and Weaknesses of Phantoms for CR/DR System Testing

HISTORY. CT Physics with an Emphasis on Application in Thoracic and Cardiac Imaging SUNDAY. Shawn D. Teague, MD

siemens.com/luminos-fusion Luminos Fusion The 2-in-1 system that fits your needs and fits your budget

Recent Development and Study of Silicon Solid State Photomultiplier (MRS Avalanche Photodetector)

Semiconductor Detector Systems

Performance and care. all in one

SYLLABUS. 1. Identification of Subject:

Basis of Computed Radiography & PACS

Shad-o-Box HS Product Family

SYLLABUS. TITLE: Equipment Operation I. DEPARTMENT: Radiologic Technology

Digital Imaging Considerations Computed Radiography

Based on lectures by Bernhard Brandl

Image sensor combining the best of different worlds

MICOD CHARGE SENSITIVE AMPLIFIER CSA-250

Performance evaluation of a photon counting detector for high energy NDT applications

Acquisition, Processing and Display

Detectors for microscopy - CCDs, APDs and PMTs. Antonia Göhler. Nov 2014

Silicon sensors for radiant signals. D.Sc. Mikko A. Juntunen

DEVELOPMENT OF A FLAT PANEL DETECTOR WITH AVALANCHE GAIN FOR INTERVENTIONAL RADIOLOGY MATTHEW M. WRONSKI

Overview 256 channel Silicon Photomultiplier large area using matrix readout system The SensL Matrix detector () is the largest area, highest channel

A Comprehensive Review of Image Production

Lecture 2. Part 2 (Semiconductor detectors =sensors + electronics) Segmented detectors with pn-junction. Strip/pixel detectors

Software and Hardware in CCTA. Elly Castellano PhD

Highly Miniaturised Radiation Monitor (HMRM) Status Report. Yulia Bogdanova, Nicola Guerrini, Ben Marsh, Simon Woodward, Rain Irshad

Transcription:

X-ray detectors in healthcare and their applications Pixel 2012, Inawashiro September 4th, 2012 Martin Spahn, PhD

Clinical applications of X-ray imaging Current X-ray detector technology (case study radiography and angiography) Drivers shaping X-ray imaging An outlook to the possible future of X-ray detectors: Opportunities and challenges Summary

Clinical applications of X-ray imaging Current X-ray detector technology (case study radiography and angiography) Drivers shaping X-ray imaging An outlook to the possible future of X-ray detectors: Opportunities and challenges Summary

X-ray imaging is more than 100 years old

and has become an indispensible tool for a broad spectrum of clinical imaging applications

The geometry of X-ray acquisition systems is common to different medical imaging modalities Patient X-ray source X-ray image(s) (represent the absorption distribution) X-ray detector

Multi-slice CT (computed tomography) uses a fan-beam geometry with multiple image acquisitions during the rotation Patient X-ray source Gantry X-ray detector

Multi-slice CT (computed tomography) uses a fan-beam geometry with multiple image acquisitions during the rotation Patient Line integrals for each projection

Coronary CTA: In-stent restenosis evaluation Results may depend on specific product configuration

Screening & diagnostic mammography: High conspicuity of a tumor-suspicious lesion Depiction of small structures, such as microcalcifications Clear visualization even in dense glandular tissue With courtesy of Prof. Dr. Uhlenbrock & Partner, Dortmund, Germany Results may depend on specific product configuration

Card-angiography: Visualization of stenosis in left coronary artery Results may depend on specific product configuration

Card-angiography: Visualization of stents Visualization of fully depleted stent Visualization of stent struts 3 mm Results may depend on specific product configuration

Rotational angiography allows generation of volumetric data and CT-like images Rotational Angiography

Rotational angiography allows generation of volumetric data and CT-like images Rotational Angiography Display in the room Reconstruction and visualization on the workstation Image transfer

Neuroradiology: Rotational angiography requires low contrast resolution and high dynamic range syngo DynaCT subdural hematoma Conventional CT Results may depend on specific product configuration

Neuroradiology: Good spatial and temporal resolution for dynamic flow evaluation (iflow) Results may depend on specific product configuration

Clinical applications of X-ray imaging Current X-ray detector technology (case study radiography and angiography) Drivers shaping X-ray imaging An outlook to the possible future of X-ray detectors: Opportunities and challenges Summary

Most flat detectors are based on indirect conversion via a scintillator and an active pixel matrix of a-si photodiodes

What are the advantages of the CsI scintillators and amorphous silicon active matrix photodiode arrays? Scintillators based on CsI:Tl Good absorption properties due to high atomic numbers (55 and 53 for Cs and I, respectively) Needle-structure allows good light collection (high MTF) Photodiode arrays based on amorphous Silicon (a-si) LCD technology for consumer market (TVs, monitors) has made the technology available Semi-conductor properties (photodiodes, TFTs) Plasma-deposition process allows large area detectors (40x40 cm 2 ) with several million pixels Radiation hardness

Image acquisition process: The a-si PIN photodiode readout is destructive

Readout process for active pixel matrix Line select Line select Line driver Line select Line select ADC Column decode

Flat detectors based on CsI/a-Si have replaced image intensifiers and analog film Image intensifier camera system Analog film Flat detectors

How did the introduction of flat panel detector technology impact radiology and cardiology? Radiography/mammography in the radiology department: Higher DQE improved X-ray dose efficiency Loss of film is no longer an issue Acquisition medium (detector) and display medium (monitor) are separated allowing independent optimization and image processing Real-time access of physician to image data via PACS Patient data and procedure preparation via HIS/RIS Productivity increase due to workflow improvements Computer-aided detection (CAD) in mammography Angiography in the radiology/cardiology department: Improved angulations due to compact build Improved 3D-imaging (14/16 bit, no image distortions) Litte or no susceptibility to magnetic and electromagnetic fields

Different clinical applications generate different requirements for the respective X-ray detectors* Multi-Slice CT General X-ray Angiography Mammography Detector area 10 x 100 43 x 43 20 x 20 24 x 30 [cm 2 ] (segmented) 30 x 40 Pixel size 1000 150 200 150-200 85 [ m] (and binning) Pixel matrix (typ.) 100 x 1000 3000 x 3000 2000 x 2000 3000 x 4000 Frame rate 5000 1 1 60 1 [1/s] (single) (depends on appl. DSA, fluoro, 3D) (single or tomosynthesis) Max. photon energy 80 140 40 150 40 125 23 35 [kev] Max. photon flux ~ 10 9 ~ 10 8 ~ 10 8 ~ 10 7 [1/mm 2. s] Current technology Gd 2 O 2 S CsI CsI a-se/electr. & TFT (a-si) PD array (Si) PD/TFT (a-si) PD/TFT (a-si) CsI & PD/TFT (a-si) * Values are typical. They may differ in particular implementations

Clinical applications of X-ray imaging Current X-ray detector technology (case study radiography and angiography) Drivers shaping X-ray imaging An outlook to the possible future of X-ray detectors: Opportunities and challenges Summary

Healthcare systems are influenced by global trends Change of demographic structure Increased access to healthcare Trend towards outcome-oriented reimbursement Need for higher efficiency

Medical imaging will have to adapt to changes in the healthcare environment Increased dose awareness Trend towards comodity (cost) Medical Imaging Additional value for the clinician Image fusion Trend towards minimally invasive procedures

Diagnostic/therapeutic X-ray systems and in turn X-ray sensors will have to support the healthcare trends Performance Dose efficiency New applications Device integration Cost Mainstream technologies

Clinical applications of X-ray imaging Current X-ray detector technology (case study radiography and angiography) Drivers shaping X-ray imaging An outlook to the possible future of X-ray detectors: Opportunities and challenges Summary

What detector technologies are on the horizon for future X-ray imaging? Integrating detectors based on amorphous silicon Image quality improvements Cost reduction

Flat detectors based on CsI / a-si: Evolution in performance improvements and cost reduction Flat Detector Main components Performance Parameter Scintillator DQE(f) detective quantum efficiency MTF(f) modulation transfer function Sensor plate (asi) Optimization Optimization DQE(f) MTF(f) Electronic noise Image lag Readout speed Readout Chip Electronic noise Readout speed Optimization Electronics, Mechanics, FW, Data interface Bit depth Readout speed

What detector technologies are on the horizon for future X-ray imaging? Integrating detectors based on amorphous silicon Image quality improvements Cost reduction Integrating detectors based on CMOS Image quality and performance improvements Higher integration

Flat detector technology: Integrating detectors with CMOS readout X-rays X-rays Scintillator (X-ray to optical photons) Optical coupling Scintillator (X-ray to optical photons) Optical coupling amorphous silicon active matrix CMOS

CMOS enables on-pixel amplification a-si:h (amorphous Silicon) CMOS Amplifier PD PD TFT Switch

Multi-transistor designs on pixel allow enhancement of features and enable new functions On-pixel amplification Fast readout Non-destructive readout Global shutter Small structures Improved low dose imaging Lag-free imaging High frame rates High fill factors Improved bi-plane imaging (X-ray scatter) Image quality improvement CMOS a-si (status quo) Dose

What detector technologies are on the horizon for future X-ray imaging? Integrating detectors based on amorphous silicon Image quality improvements Cost reduction Integrating detectors based on CMOS Image quality and performance improvements Counting detectors based on complex ASICs? Dose reduction New applications

Counting detectors based on CdTe / ASIC Detector schematics Common cathode X-rays HV Semiconductor (direct converter) ASIC Peripheral electronics Pixel anode TSV Substrate

Counting detectors based on CdTe / ASICs Opportunities: Changing X-ray imaging Lower dose: Improved DQE (detective quantum efficiency) SNR 2 out ( f ) = DQE ( f ). SNR 2 in ( f ) Quantum-noise-limited imaging (no electronic noise) Improved contrast (CNR): proportional to dose Low energies contribute more (equal weighting of spectrum) Weighting of energy bins in case of energy discriminating counting detectors New imaging applications: Material discrimination techniques ( color imaging ) Material-selective imaging (K-edge imaging)

Schematic structure of counting pixel C fb Discriminator Detector Input Preamp V thres Counter

Schematic structure of counting pixel with energy discriminating capability (color imaging) Discriminators Readout logic C fb V thr 1 Counter 1 Preamp V thr 2 V thr 3 Counter 2 Counter 3 Output Detector input V thr 4 Counter 4

Technological challenges of counting X-ray detectors Detector material: K-escape and charge sharing Material inhomogeneity (inclusions, charge collection inefficiency, ) Temporal drifts (trap filling, polarization, ) Hybridization: Reliable bump-bonding Mechanical stress (thermal issues) ASIC: Pile-up at high X-ray fluxes Complex pixel structure (pulse shaper, amplifier, comparator, counter, readout logic) Power consumption TSV technology if 4-side buttable detector modules are required

Example of a counting ASIC pixel layout The Medipix3 Chip Source: Rafael Ballabriga New Charge Summing for Medipix3 Workshop on Spectral Xray Imaging, CERN, Geneva 2011 The Medipix Collaboration, Dr. Michael Campbell, spokesperson

Hybrid prototype CT scanner with integrating and counting detectors has been built by Siemens The Hybrid Prototype CT Scanner Gantry from a clinical scanner with two X-ray systems: A: conventional detector B: counting prototype Focus-detector distance 1.1m Bore diameter 78cm Gantry rotation time 1.0s / rot. Peak X-ray flux 2.5x10 8 /(s. mm²) 80kVp up to 555mA 100kVp up to 250mA 120kVp up to 150mA 140kVp up to 100mA A B Please note: This device is an inhouse prototype scanner for research purposes, not intended for patient examinations! Source: S. Kappler et al., Siemens Healthcare, SPIE Medical Imaging 2012

Clinical applications of X-ray imaging Current X-ray detector technology (case study radiography and angiography) Drivers shaping X-ray imaging An outlook to the possible future of X-ray detectors: Opportunities and challenges Summary

Summary Healthcare systems are adapting to global trends such as demographic changes, outcome orientation of clinical processes and the need for highly efficient procedures Changes in the healthcare systems influence the development of detector technology such as performance, dose efficiency and cost Current mainstream technologies are based on integrating detectors deploying a-si active matrices (radiography, angiography, mammography) or photo-diode arrays (CT) New technologies (CMOS, photon counting) are on the horizon or subject of R&D

X-ray technology has come a long way...... and there is still much ahead 1895 2012 Thank you

On account of certain regional limitations of sales rights and service availability, we can not guarantee that all products included in this information are available through the Siemens sales organization worldwide. Availability and packaging may vary by country and are subject to change without prior notice. Some/All of the features and products described herein may not be available in the United States or other countries. Caution: Federal law restricts this device to sale by or on the order of a physician. All rights reserved. Copyright 08.2012 Siemens AG