Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations

Similar documents
Surgical data reveals that Q-Factor is important for good surgical outcome

10/25/2017. Financial Disclosures. Do your patients complain of? Are you frustrated by remake after remake? What is wavefront error (WFE)?

Author Contact Information: Erik Gross VISX Incorporated 3400 Central Expressway Santa Clara, CA, 95051

Customized Correction of Wavefront Aberrations in Abnormal Human Eyes by Using a Phase Plate and a Customized Contact Lens

What s New in Ocular Biomechanics?

Normal Wavefront Error as a Function of Age and Pupil Size

Clinical Update for Presbyopic Lens Options

The Aberration Structure of the Keratoconic Eye

Principles and clinical applications of ray-tracing aberrometry (Part II)

In this issue of the Journal, Oliver and colleagues

Assessing Visual Quality With the Point Spread Function Using the NIDEK OPD-Scan II

What is Wavefront Aberration? Custom Contact Lenses For Vision Improvement Are They Feasible In A Disposable World?

Visual Outcomes of Two Aspheric PCIOLs: Tecnis Z9000 versus Akreos AO

Aberrations Before and After Implantation of an Aspheric IOL

Trust your eyes. Presbyopic treatment methods on the cornea. PresbyMAX Decision criteria and patient s acceptance

Special Publication: Ophthalmochirurgie Supplement 2/2009 (Original printed issue available in the German language)

Visual outcomes and higherorder aberrations of wavefront vs. combined wavefront aspheric myopic LASIK

Dr. Magda Rau Eye Clinic Cham, Germany

Refractive Power / Corneal Analyzer. OPD-Scan III

NOW. Approved for NTIOL classification from CMS Available in Quar ter Diopter Powers. Accommodating. Aberration Free. Aspheric.

Improving Lifestyle Vision. with Small Aperture Optics

Wave Front Topography. ReSeeVit Evolution Topography Module for Modi Topographer

Quality of Vision With Multifocal Progressive Diffractive Lens: Two-Year Follow-up

Comparison of higher order aberrations with spherical and aspheric IOLs compared to normal phakic eyes

Corneal laser surgery is currently shifting its

Causes of refractive error post premium IOL s 3/17/2015. Instruction course: Refining the Refractive Error After Premium IOL s.

Q-value Adjusted Ablation PRK PRK. Allegretto Randomized control trial : .(Corneal asphericity) (PRK) Photo refractive keratectomy

OPTI-201/202 Geometrical and Instrumental Optics Copyright 2018 John E. Greivenkamp. Section 16. The Eye

Aberration Interaction In Wavefront Guided Custom Ablation

Explanation of Aberration and Wavefront

Maximum Light Transmission. Pupil-independent Light Distribution. 3.75D Near Addition Improved Intermediate Vision

Treatment of Presbyopia during Crystalline Lens Surgery A Review

4th International Congress of Wavefront Sensing and Aberration-free Refractive Correction ADAPTIVE OPTICS FOR VISION: THE EYE S ADAPTATION TO ITS

Multifocal Progressive Diffractive Lens to Improve Light Distribuition and Avoid Light Loss: Two Years Clinical Results

Section 22. The Eye The Eye. Ciliary Muscle. Sclera. Zonules. Macula And Fovea. Iris. Retina. Pupil. Optical Axis.

Customized intraocular lenses

Optical Path Difference Scanning System OPD-Scan II ARK-10000

Transferring wavefront measurements to ablation profiles. Michael Mrochen PhD Swiss Federal Institut of Technology, Zurich IROC Zurich

Headline. Pseudophakic Implants, Aspherical Optics, Quality of Vision for Cataract Patients Subline. Damien Gatinel, MD, PhD

Refractive Surgery: Vance Thompson, MD, FACS Refractive Surgeon. Oculeve Wavetec Zeiss Mynosys LRG Equinox Precision Lens ORA Amaken EXCELLens

Unique Aberration-Free IOL: A Vision that Patients

The Aberration-Free IOL:

Optical Characteristics of Next Generation Dual Optic IOL

Retrospective analysis of changes in the anterior corneal surface after Q value guided LASIK and LASEK in high myopic astigmatism for 3 years

EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION. (43) Date of publication: Bulletin 2010/16

Ron Liu OPTI521-Introductory Optomechanical Engineering December 7, 2009

Clinical Evaluation 3-month Follow-up Report

Optical Connection, Inc. and Ophthonix, Inc.

Optical aberrations and the eye Part 3

Wavefront Aberrations in Eyes With Acrysof Monofocal Intraocular Lenses

Design of a Test Bench for Intraocular Lens Optical Characterization

The Impact of New Generation Aspherical Soft Contact Lenses on Quality of Vision: A Comparison with Spherical Contact Lenses and Spectacle Correction

Roadmap to presbyopic success

Although, during the last decade, peripheral optics research

Schwind Amaris 1050 Smart Pulse Technology

ATLAS Corneal Topography System

Aberrations and Visual Performance: Part I: How aberrations affect vision

NON-LINEAR ASPHERIC ABLATION PROFILE FOR PRESBYOPIC CORNEAL TREATMENT USING THE MEL80/90 AND CRS MASTER PRESBYOND MODULE

Crystalens AO: Accommodating, Aberration-Free, Aspheric Y. Ralph Chu, MD Chu Vision Institute Bloomington, MN

Soft CL Multifocals Design and Fitting. Soft Multifocal Lens Designs. Issues Surrounding Multifocals. Blur Interpretation. Simultaneous Vision Designs

The Eye as an Optical Instrument Pablo Artal

FITTING GUIDE PRACTITIONER S ROSE K2 KC ROSE K2 NC ROSE K2 IC ROSE K2 PG NIPPLE CONE IRREGULAR CORNEA POST GRAFT

*Simulated vision. **Individual results may vary and are not guaranteed. Visual Performance When It s Needed Most

Corneal and total optical aberrations in a unilateral aphakic patient

Update on Aspheric IOL Technology

Choices and Vision. Jeffrey Koziol M.D. Thursday, December 6, 12

Calculated impact of higher-order monochromatic aberrations on retinal image quality in a population of human eyes: erratum

Construction of special eye models for investigation of chromatic and higher-order aberrations of eyes

CLINICAL SCIENCES. Corneal Optical Aberrations and Retinal Image Quality in Patients in Whom Monofocal Intraocular Lenses Were Implanted

DesiGneD and ManUFaCTUreD in italy The sharpest vision.

Monochromatic Aberrations and Emmetropization

Choices and Vision. Jeffrey Koziol M.D. Friday, December 7, 12

Optical Zone Diameters for Photorefractive Corneal Surgery

WaveMaster IOL. Fast and accurate intraocular lens tester

Designing multifocal corneal models to correct presbyopia by laser ablation

Effect of rotation and translation on the expected benefit of an ideal method to correct the eye s higher-order aberrations

The influence of the aspheric profiles for transition zone on optical performance of human eye after conventional ablation

Posterior corneal aberrations and their compensation effects on anterior corneal. aberrations in keratoconic eyes. Minghan Chen and Geunyoung Yoon

This is the author s version of a work that was submitted/accepted for publication in the following source:

KERATOCONUS. In the most advances cases, the corneal deformation can be easy observed fig. 1. Fig. 1

ORIGINAL ARTICLE. Optical Quality of the Eye with the Artisan Phakic Lens for the Correction of High Myopia

Development of a Calibration Standard for Spherical Aberration

Mechanism of compensation of aberrations in the human eye

Is Aberration-Free Correction the Best Goal

Centre Hospitalier Universitaire et Psychiatrique de Mons-Borinage. B-Flex Multifocal. Dr Emmanuel Van Acker Belgium

Effects of Pupil Center Shift on Ocular Aberrations

THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening

NIDEK ADVANCED VISION EXCIMER LASER SYSTEM

Long-term quality of vision is what every patient expects

Although the presence of optical imperfections

The pupil of the eye is a critical limiting factor in the optics

TRANSLATIONAL SCIENCE. Effect of Crystalline Lens Aberrations on Adaptive Optics Simulation of Intraocular Lenses

PATIENT SELECTION THE RIGHT PATIENT UNDERPROMISE AND OVERDELIVER THE PERFECT SPECTACLE FREE TREATMENT. Desires Less Dependence on glasses

Abetter understanding of the distribution of aberrations in

WaveMaster IOL. Fast and Accurate Intraocular Lens Tester

Vision Shaping Treatment

Effects of intraocular lenses with different diopters on chromatic aberrations in human eye models

A Computational Model for Predicting Visual Acuity from Wavefront Aberration Measurements

(495) (495)

Subjective Image Quality Metrics from The Wave Aberration

Transcription:

Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations Seema Somani PhD, Ashley Tuan OD, PhD, and Dimitri Chernyak PhD VISX Incorporated, 3400 Central Express Way, Santa Clara, CA 95051, USA Email: seemas@visx.com; ashleyt@visx.com; dimitric@visx.com Phone: (408) 773-7353 Fax: (408) 773-7253

Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations ABSTRACT Purpose The optical quality of retinal images is dependent on the refracting elements of the eye 1 including the nominally aspheric cornea and crystalline lens. This paper presents a retrospective theoretical analysis of the impact of corneal asphericity on the quality of retinal images. Clinical data are from the VISX, Incorporated CustomVue IDE. Method Topography, contrast sensitivity, and visual acuity data were collected from 278 myopic eyes before and after wavefront-guided laser surgery. The measured corneal surface of each eye was fitted to a conic, and a Q-value was computed for a 5.5 mm pupil. A model eye was employed to simulate various amounts of optical asphericity. Results Preoperatively, most corneas exhibited negative conic shape constants. Postoperatively, corneas were about equally divided between positive and negative conics. There was no statistically significant correlation between the shape of the cornea and the subjects perceptions of image quality including contrast sensitivity (CSF) and visual acuity (VA). Simulations showed that the corneal Q-value could vary from more to less prolate depending upon the shape of the internal surface. Conclusion Following wavefront-guided LASIK, CSF is usually good and is not dependent upon the corneal conic shape. Better visual outcomes are more likely with a customized shape than a standard best conic shape.

INTRODUCTION Most of the refractive interfaces of a human eye are aspheric. Geometry and changes in the refractive index determine the optical aberrations contributed by each aspheric surface. The quality of retinal images depends on the combined optical effects of all these elements. The individual aberrations of an optical element of a human eye are partially compensated by other elements. By this compensatory effect, overall aberration of the eye becomes smaller and results in better image quality. Artal et al. 1,2 published a study showing that higher order aberrations, in particular spherical aberration, of the cornea and crystalline lens are usually of opposite signs, which explains the compensatory effect. Because the most substantial change in the refractive index occurs at the cornea, the geometry of that structure greatly impacts retinal image quality. The corneal surface is often modeled as conic or bi-conic. 3 A conic surface is characterized by the radius of curvature at the apex and a conic constant. A prolate (tip-of-the-egg) surface has a positive conic constant. An oblate (flat-sideof-the-egg) surface has a negative conic constant. Modeling the cornea as a conic is a simplification. A general aspheric shape would be more accurate. An even closer representation of the cornea can be achieved with a numerical surface map. Refractive surgery changes the optical power of the eye by modifying the corneal surface. The cornea is made steeper for hyperopic corrections and flatter for myopic corrections, altering the curvature of the corneal surface, and thus its asphericity. The conventional LASIK procedure is designed to correct only the low order optical aberrations of defocus and astigmatism. However following conventional LASIK procedures, many eyes have experienced increases in spherical aberration. This unexpected and undesirable phenomenon has provoked a great deal of interest and investigation. Because most natural corneas are

prolate, it has been suggested that the post-surgical increase in spherical aberration arises from changing the prolate shape, and that good quality vision can best be achieved with a theoretically optimal conic shape. 4 This thesis is at odds with the thesis that the best vision can be created by customized wavefrontguided treatments, which correct defocus and higher order aberrations of the whole eye on an individual basis. The purpose of this study was to quantify the relevance of the corneal conic constant to quality of vision. The study was approached from two different perspectives: 1) an analysis of data from pre- and post- LASIK eyes, all of which had received wavefront-guided treatments; and 2) through optical simulations. The correlation between the objectively measured corneal conic constant and subjectively measured image quality in pre- and post-surgical eyes was analyzed based on data from a multi-center clinical study of wavefront-guided LASIK surgeries for the correction of myopia. Corneal surfaces were measured by topography, and the quality of retinal images was assessed with contrast sensitivity and visual acuity measurements. The optical simulations were conducted in an attempt to identify a theoretically preferred conic corneal shape that would provide good images for the range of optical aberrations naturally present in the internal optics of the human eye. METHODS A retrospective analysis was done of data from a multi-center study in which wavefront-guided LASIK surgeries were performed using the STAR S4 Excimer Laser System (VISX, Incorporated, Santa Clara, CA). Wavefront measurements were performed using the WaveScan Wavefront system (VISX, Incorporated, Santa Clara, CA), which is based on the Shack-Hartmann wavefront sensor.

Study Patients One hundred forty-two females and 136 males participated in the study. Two hundred seventy-eight eyes with myopic astigmatism underwent wavefrontguided LASIK procedures. Cohort Description (n = 278 eyes) Average (±SD) age 34.97 (±7.83) Baseline manifest refraction -3.56 (±1.35) DS -0.71 (±0.71) DC BCVA -0.10 (±0.05) logmar All procedures conformed to the Declaration of Helsinki for research involving human subjects. Ethics committee approval was obtained, and all participants in the study signed an informed consent form. Measurements Eleven surgeons participated in the study. Subjects were recruited from five different surgical centers across the United States. The subjects who wore contact lenses were asked to discontinue contact lens use three weeks before surgery. Comprehensive evaluations of vision and ocular health were done before surgery and at each post-surgical follow-up visit. Corneal topographies were taken at each visit using a Zeiss -Humphrey Topography unit (Zeiss Meditech, Dublin, California). Visual acuity data and subjective manifest refractions were collected using the ETDRS chart (Vector Vision, Dayton, Ohio). Contrast sensitivity data were collected using the contrast sensitivity chart from Vector Vision. Retro-illumination of both charts was 85 cd/m 2. Spatial frequencies of 3,

6, 12, and 18 cpd were tested with 15 steps (0.12-0.15 logcs per step) at each frequency. Contrast sensitivity under mesopic conditions was tested at 3 cd/m 2 with patients wearing a neutral density filter. The glare source was generated by attaching two 50-watt halogen flood lights to each side of the chart to simulate oncoming headlights. Topography Analysis Corneal topography data were analyzed using MATLAB (The MathWorks Inc, Natick, MA) software. Pupil size was 5.5 mm for all the eyes. The conic shape constant (Q) value was derived by fitting the data from each eye to a conic surface using a least square approach. Optical Simulation A model eye (Figure 1) with clinically relevant parameters was used in optical simulations performed in ZEMAX -EE software (ZEMAX Development Corporation, San Diego, CA). 5,6 ZEMAX performed ray tracing through the model eye using three wavelengths, 0.45, 0.55, and 0.65 microns. Images, MTF and other relevant optical matrixes were calculated by weighting the monochromatic response of each of the three wavelengths by 0.1, 0.65, and 0.25, respectively. The weighting factors were set according to the human color response. The modeled surfaces were radially symmetrical conics or aspheric surfaces with even-power radial terms. Because modeling the lens with a graded index profile does not result in significantly different optical performance, and its index profile is not accurately known, the refractive index was assumed to be constant across the lens. 5,6 The crystalline lens and posterior cornea were modeled as conic surfaces. In simulations, their conic shape constants were changed, and

the conic shape of the anterior corneal surface was optimized for each set of parameters. Figure 1: The model eye used in simulations RESULTS Analysis of preoperative topography showed that most eyes had a negative conic constant (prolate shape). Very few eyes had a conic constant between 0 and +0.25 (oblate shape). Post-operative topography data showed that 6 months after the surgery the eyes were almost equally divided between positive and negative conic constants. Contrast Sensitivity and Q-Value Figure 2 shows a plot of Q-value vs. contrast sensitivity measured 6 months after surgery at a spatial frequency of 12 cpd. These data reveal an almost equal spread of negative and positive Q-values. The correlation coefficients between contrast sensitivity and Q-values were calculated for eyes pre-surgery and 6 months post surgery. Contrast sensitivity data included in this analysis was collected under three different illumination conditions (photopic, mesopic and mesopic with glare) and at four ( 3, 6, 12, and 18cpd) different spatial frequencies. As shown in Table 1, all of these correlation coefficients are insignificant. These data imply that in both pre-operative and post-operative eyes there is no correlation between contrast sensitivity and Q-value.

Table 1: Correlation coefficient between Q-factor and contrast sensitivities pre-op post-op r 2 photopic mesopic mesopicglare disability glare photopic mesopic mesopicglare disability glare 3 cpd 0.01 0.00 0.00 0.00 0.01 0.00 0.00 0.00 6 cpd 0.00 0.00 0.00 0.00 0.00 0.01 0.00 0.00 12 cpd 0.00 0.00 0.01 0.00 0.01 0.00 0.00 0.00 18 cpd 0.00 0.01 0.00 0.00 0.00 0.00 0.01 0.01 Figure 2: Six-month post-op data do not show any correlation between contrast sensitivity and Q- factor. As shown in Table 1, all the correlation coefficients are statistically insignificant. Visual Acuity and Q-Value Best corrected visual acuity (BCVA) and Q-values of the eyes before surgery is plotted in Figure 3A. Uncorrected visual acuity (UCVA) and BCVA at 6 months after surgery are plotted in Figures 3B and 3C, respectively. Distribution of pre-operative eyes and post-operative eyes between negative and positive Q- values is very similar for different visual acuity levels. The ratio of prolate to oblate eyes is very different before and after surgery. However, before and after surgery the ratio of prolate to oblate eyes in each different acuity category is similar to the respective ratio of total eyes. These data imply that BCVA is not dependent on Q-values either before or after surgery. Figure 3A: Best corrected visual acuity at pre-op vs. Q; Figure 3B: Uncorrected visual acuity at 6months post-op vs. Q and Figure 3C: Best corrected visual acuity at 6 months post-op vs. Q. Visual acuity does not correlate with Q-values in pre-op or 6-month post-op data.

Simulation Results Figure 4 shows that corneal Q-factor varies significantly depending on the spherical aberration of the internal optics, suggesting that the optimal corneal shape is determined by the total aberrations of the internal optics, and therefore there is no single or narrow range of preferred conic shapes that would provide good images for all eyes. An additional check was made by introducing asymmetric aberrations into the internal optics of the model eye. When coma was introduced to the model eye by tipping the crystalline lens, the resulting image could not be corrected by optimizing the conic shape of the cornea (Figure 5). Figure 4: Corneal Q-value vs. asphericity of the internal optics of the model eye. In the simulation the internal optics were changed, and the corneal Q-value was computed to optimize the retinal image. Depending upon the asphericity, (or effective Q of the internal optics) the cornea had to be more or less of the prolate type to achieve good retinal images. Figure 5: A This example of the PSF of the model eye with coma illustrates the fact that coma-like aberrations cannot be corrected by the conic shape or a radially symmetrical aspheric corneal surface. Coma was introduced by tipping the crystalline lens and then optimizing the conic shape parameter of the cornea. The effect of coma is still present in the PSF. B PSF without the tip in the lens. Furthermore, if other higher order aberrations were assigned to the internal optics, the optimal corneal shape would have to be one that compensated all the higher order aberrations of the internal optics. The resulting corneal surface would be more complicated than a conic surface or a radially symmetric aspheric surface

DISCUSSION Data from a clinical study of 278 eyes revealed no statistically significant correlation between the conic constant of the cornea and contrast sensitivity or visual acuity. Most of the eyes had negative Q-values or prolate shape before the surgery. Post operatively, eyes were equally distributed between positive and negative values. Before and after the surgery the contrast sensitivity distribution of eyes that had positive Q-values was similar to that of the eyes with negative Q- values, i.e., no relationship was observed between contrast sensitivity and Q- values. Similarly, the visual acuity distribution of eyes of pre-op and post-op was similar for eyes with positive and negative Q-values. Simulations showed that the conic shape of the cornea cannot correct asymmetric aberrations. Variation of internal optics naturally present in the population is too great for conic shaped corneas with a narrow range of conic constants to provide optimal vision for all eyes. In general, good retinal images are achieved when defocus is corrected and the higher order aberrations are optimally corrected with a customized corneal shape. The ablation algorithms for this generation of wavefront-guided surgeries are mathematically more advanced than in the early days of refractive surgery. However, to harness the benefits of customization, a high degree of accuracy and precision in ablating the desired shape on the cornea is needed. Accuracy is compromised by system errors; e.g., registration errors, eye movements, and disparity between the assumed shape and the shape created by the laser. By taking these errors into account, more accurate ablations can be made, and the true potential of customization can be realized. The target shape of the ablation remains an open question. Should all monochromatic higher order aberrations be completely removed, or will some preferred amount of higher order aberrations

provide better visual satisfaction? The question of the optimal target correction is a complex one ocular aberrations may change over the short term as well as over the long term; they change as the pupil changes size with lighting and accommodation; and they change with age. What is the best balance? All of these unanswered questions are currently under investigation. References 1. Artal P, Guirao A. Contribution of cornea and the lens to the aberrations of the human eye. Opt Lett 1998;23:1713-1715. 2. Artal P, Guirao A, Berrio E, Williams D. Compensation of corneal aberrations by the internal optics in the human eye. Journal of Vision 2001; 1:1-8. 3. Schwiegerling J, Snyder R. Custom photorefractive keratectomy ablations for the correction of spherical and cylindrical refractive error and higherorder aberration. J Opt Soc Am A 1998; 15: 2572-2579. 4. Holladay J, Janes J. Topographic changes in corneal asphericity and effective optical zone after laser in situ keratomileusis. J Cataract Refract Surg 2002; 28:942-947. 5. Liou HL, Brennan NA. Anatomically accurate, finite model eye for optical modeling. J. Opt. Soc Am A 1997;14:1684-1695. 6. Sanz IE, Navarro R. Off axis aberrations of a wide-angle schematic eye model. J Opt Soc Am A 1999; 16:1881-1891.

Figures Figure 1 Figure 1: The model eye used in simulations

Figure 2 Mesopic Contrast Sensitivity (12c/d) and Corneal Shape 6 months post-op 1.0 0.5 Q 0.0-0.5 R 2 = 0.0032-1.0 0.0 0.5 1.0 1.5 2.0 2.5 logcs (12 c/d) Figure 2: Six-month post-op data do not show any correlation between contrast sensitivity and Q- factor. As shown in Table 1, all the correlation coefficients are statistically insignificant.

Figure 3 A 100 Best Corrected Visual Acuity and Corneal Shape pre-op # of patients 80 60 40 20 0 20/12 20/16 20/20 20/25 BCVA Q<-0.25 Q= 0.01 to -0.25 Q= 0 to 0.25 Q>0.25 B Uncorrected Visual Acuity and Corneal Shape 6M post-op 40 # of patients 30 20 10 0 20/10 20/12 20/16 20/20 20/25 20/32 20/40 UCVA Q<-0.25 Q= 0.01 to -0.25 Q= 0 to 0.25 Q>0.25 C 40 Best Corrected Visual Acuity and Corneal Shape 6M post-op # of patients 30 20 10 0 20/10 20/12 20/16 20/20 20/25 20/32 20/40 BCVA Q<-0.25 Q= 0.01 to -0.25 Q= 0 to 0.25 Q>0.25 Figure 3A: Best corrected visual acuity at pre-op vs. Q; Figure 3B: Uncorrected visual acuity at 6months post-op vs. Q and Figure 3C: Best corrected visual acuity at 6 months post-op vs. Q. Visual acuity does not correlate with Q-values in pre-op or 6-month post-op data.

Figure 4 Q value for cornea vs asphericity in internal optics 0-0.1 Q value for cornea -0.2-0.3-0.4-0.5-0.6-0.7 0 2 4 6 8 10 Different cases of simulation with internal optics generating increasingly more negative spherical aberration Figure 4: Corneal Q-value vs. asphericity of the internal optics of the model eye. In the simulation the internal optics were changed, and the corneal Q-value was computed to optimize the retinal image. Depending upon the asphericity, (or effective Q of the internal optics) the cornea had to be more or less of the prolate type to achieve good retinal images.

Figure 5 A B Figure 5: A This example of the PSF of the model eye with coma illustrates the fact that coma-like aberrations cannot be corrected by the conic shape or a radially symmetrical aspheric corneal surface. Coma was introduced by tipping the crystalline lens and then optimizing the conic shape parameter of the cornea. The effect of coma is still present in the PSF. B PSF without the tip in the lens.