PROVEN DEPENDABLE SUSTAINABLE

Similar documents
DMI FR1511 PANEL (JC) - J CLOSURE DMI WALL PANEL SOFFIT TO WALL PANEL PROVEN DEPENDABLE SUSTAINABLE METAL ENVELOPE SYSTEMS SINCE 1988

MAXIMUM PANEL ATTACHMENT FASTENER SPACING IS 24" O.C. ALL FASTENERS TO PENETRATE WOOD 3/4" MIN. AND METAL FRAMING 1/2" MIN.

900 SERIES WALL PANELS

DW VERTICAL INSTALLATION

WESTERN WAVE Panel. Vertical Installation and Technical Information

SEAL PLATE SP4413 VERTICAL SP4414 1"[25] VERT. PANEL JTS. 1/2"[13] INTERM. SPLICES DESIGN LOADS AND SLAB EDGE DISTANCES. 1 2 NOM.

400 SERIES VERTICAL INSTALLATION

DW HORIZONTAL INSTALLATION


TABLE OF CONTENTS A-1

WESTERN WAVE Panel. Horizontal Installation and Technical Information

STEVE ENNIS ARCHITECT 1108 EAST JACKSON STREET MEDFORD, OREGON 97504

APRON FLASHING NOTES: SHEET METAL APRON FLASHING WITH HEMMED EDGE RAGGLE SEALANT UNDERLAYMENT TURNED UP WALL

VENTED GABLE DETAIL ROOF PANEL GABLE FLASHING 24" C/C MAX. BUTYL SEALANT TAPE ROOF PURLIN FLASH AB-1, AB-2, AB-3, OR AB-4

REGAL. Installation Manual

Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications.

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg FACADES - BRICK INDEX SHEET

SHEET METAL FLASHING AND TRIM Christ on the Mountain

ProSnap 100 STANDARD DETAILS

VENTED GABLE DETAIL ROOF PANEL GABLE FLASHING 24" C/C MAX. BUTYL SEALANT TAPE ROOF PURLIN FLASH AB-1, AB-2, AB-3, OR AB-4

CERACLAD.

Table of Contents. Notes to Designer/User Map of Typical Roof Conditions Fastener Placement Fastener Selection...

KS42 MF SERIES - HORIZONTAL INSTALLATION

Adorn Mortarless Stone Veneer Installation Natural Concrete Products

FlexLoc. Technical/Installation Information

TABLE OF CONTENTS A-1...TABLE OF CONTENTS A-2...GENERAL NOTES B-1 & B-2...GENERAL INFORMATION

KS SERIES - VERTICAL INSTALLATION

CFDTT-01. Control Joint Study (General)

Tuff-Rib Install Guide

TYPICAL FRAMING AND STITCH FASTENER PATTERNS FOR MAX-RIB PANELS

Features 24 ga steel or 26 ga steel. Colors available on standard or premium and metallic. 16 to 24 o.c. On site factory made.

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.

Table of Contents Light Gauge Metal Roof & Wall Panels

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.

Inspire Slate Starter Piece Hip and Ridge. 13 1/2" Height: 13 ½" Width: 12" Squares/ Pallet. Bundles/ Square

The better way to build TM. Installation Manual ROOF SIPs

CertainTeed. Shake / Slate Installation Guide

MULTI-STORY FIRE STOPPING ASSEMBLY FRAMED OPENING JAMB (LOW CELL) INDEX SHEET

MINI/MAXI-BATTEN. Panel Information. Detail Conditions. Flashing Profiles

Materials. Description Quantity/Size Material Foundation Drainage material. 1.4 cu. yd. Compactible gravel

Installation Instruction 3-D Model 3D 03/01/17. 0 Flush Siding Horizontal System N/C WPS, Inc.

A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

ForceField Air & Water Barrier System. installation instructions

Inspire Aledora Slate Application Guidelines

ICC-ES Evaluation Report Reissued September 1, 2012 This report is subject to renewal September 1, 2013.

METAL ROOFING INSTALLATION GUIDE

900 SERIES PANEL SHEET INDEX STAGGERED ENDLAP STAGGERED MALE LEG AT ENDLAP CONTINUOUS FEMALE ENDLAP INSTALLATION SEQUENCE CI-WR

TECHNICAL GUIDE BEONSTONE PANELIZED STONE SIDING

Installation Guide. Step 3. Valley Flashing. Step 7. Transition Flashings and Accessories. Step 6. Hip and Ridge Installation

With Illustrations, Drawings & Step By Step Details. Click Here To Download 12,000 Shed Plans. 1 P a g e H O W B U I L D S H E D.

System for 2+ Level Buildings

DETAIL CROFT FARM OUTBUILDING RESTORATION TOWNSHIP OF CHERRY HILL, NEW JERSEY

HOW TO BUILD A 12X8 SHED

Installation Guide Index

Installation Guide - Evolution Series Wood Siding

DETAIL MANUAL for Standing Seam / Image II

Pebbletex Adhered Mat Design. Typical Details

Installation Manual. Future Shingle Products

SECTION SHEET METAL FLASHING AND TRIM

ROOFING APPLICATION STANDARD (RAS) No. 130

TIOGA Table of Contents

Perimeter Edge Metal Brochure (COMGN296) Updated: 7/18

ROOFING APPLICATION STANDARD (RAS) No. 130 INSTALLATION CRITERIA FOR WOOD SHINGLES AND SHAKES APPLICATION

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

Shapes Siding. Perfection Shingles. Chalk Line

BARRELL VAULT BATTENLESS

Table of Contents. Installation Guide for Profile with Hidden Fasteners 3. Installation Steps 4, 5. Prestige Series Moldings 6, 7. Other Accessories 8

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

Installation Instructions for Panel Siding and Soffit

~ ~ -

PRIMED STRAND REVERSIBLE SHAKE

Windows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Standard Method Revised 10/24/2016

Asphalt Shingle Installation at Roof Edges, Intersections and Valleys

RIDGEMASTER PLUS CAUTION INSTALLATION INSTRUCTIONS ALWAYS WEAR SAFETY GLASSES TOOLS NEEDED GENERAL GUIDELINES FOR RIDGEMASTER PLUS AND HIPMASTER

Finesse Profiles. Nailstrip

Installation Manual. Future Roof Shingle / Slate Products

TABLE OF CONTENTS A. PBR

Effective February, 2015

COMPOSITE SIDING INSTALLATION GUIDE

Horizon-Loc. Installation Details 16" COVERAGE C GUID_INSTL_HLOC_160606

AWNING / PATIO COVER INSTALLATION INSTRUCTIONS

Best Buy Metals Toll Free / Phone / Fax

Paraguard Roof Perimeter Systems ANSI/SPRI ES-1 Test Reports UL. Classified Products

UL Construction No. 254

12x12 Shed Plans and Building Guide

PBR Panel Installation Specifications

BUILDING THE BASIC SHED. Step A: Build the Foundation & Floor Frame

8x8 Shed Plans and Building Guide

eco-shake INSTALLATION INSTRUCTION

TABLE OF CONTENTS A-1...TABLE OF CONTENTS A-2...GENERAL NOTES B-1 & B-2...GENERAL INFORMATION (FASTENER PATTERNS)

With Illustrations, Blueprints & Step By Step Details Brought To You By ShedPlansz.Com Click Here To Get More Shed Plans

Fibre Cement G C. Batten Fixing Setout ST-01. Jan 2014 A4 PROFILE DATE SCALE DETAIL DETAIL NO. Plank joint. 600mm stud crs.

Installation Instructions for Standard Lap and Self-Aligning Lap Siding

Dura-Lock Roof System

COMPOSITE TILE INSTALLATION MANUAL

Tuff Rib Panel Installation Specifications

10x10 Shed Plans and Building Guide

Skyline Roofing. Installation, Flashings and Details Guide

TYPICAL BARGE DETAIL - CROSS SECTION

401 SW 33rd Ave Ocala, FL

Transcription:

B/SOFFIT FP CLIP 24" O.C. MAX SECTION "A-A" PLYWOOD SHEATHING #10-13 GP PANCAKE HEAD FASTENER 12" O.C. A B/SOFFIT A (JC) - J CLOSURE DMI WALL PANEL PLYWOOD SHEATHING SOFFIT TO WALL PANEL FR10-V-01-00

B/SOFFIT FP CLIP 24" O.C. MAX SECTION "A-A" #10-16 DP3 PANCAKE HEAD FASTENER 12" O.C. METAL STUD FRAMING A B/SOFFIT A (JC) - J CLOSURE MASONRY SOFFIT ENDWALL FR10-V-01-01

METAL STUD FRAMING PLYWOOD SHEATHING #10-13 GP PANCAKE HEAD FASTENERS 12" O.C. (SI) - SILL E.I.F.S. (LC) - L CLOSURE 1/4" WALL PANEL W/ SILL (EIFS SOFFIT) FR10-V-02-00

METAL STUD FRAMING #10-16 DP3 PANCAKE HEAD FASTENERS 12" O.C. B/SOFFIT (SI) - SILL WALL PANEL W/ SILL (PANEL SOFFIT) FR10-V-02-01

METAL STUD FRAMING WOOD BLOCKING #10-13 GP PANCAKE HEAD FASTENERS 12" O.C. (SI) - SILL MASONRY WALL PANEL W/ SILL (AT BLOCK) FR10-V- 02-02

FP CLIP 24" O.C. MAX #10-16 DP3 PANCAKE HEAD FASTENER @ SUPPORT (OC) - OUTSIDE CORNER POP RIVET 12" O.C. (JC) - J CLOSURE METAL STUD FRAMING #10-16 DP3 PANCAKE HEAD FASTENER @ SUPPORT POP RIVET 12" O.C. (JC) - J CLOSURE OUTSIDE CORNER FR10-V-03-00

FP CLIP 24" O.C. MAX (JC) - J CLOSURE METAL STUD FRAMING #10-16 DP3 PANCAKE HEAD FASTENER @ SUPPORT POP RIVET 12" O.C. (IC) - INSIDE CORNER #10-16 DP3 PANCAKE HEAD FASTENER @ SUPPORT INSIDE CORNER FR10-V- 03-01

SEE DMI DYNACLAD EDGE INSTALLATION GUIDE FOR COMPLETE FASTENING AND INSTALLATION INFORMATION FOR ES-1 RATED SNAP-ON COPING (CO) - DYNACLAD EDGE SNAP-ON COPING #9-15 X 1-1/2" SS FASTENER (4 PER CLEAT) MEMBRANE (AC) - ANCHOR CLEAT 1-1/4" SS RING SHANK NAIL #14-13 DP1 PANCAKE HEAD FASTENER 12" O.C. (SJ) - SPLICE JOINT WOOD BLOCKING #10-13 GP PANCAKE HEAD FASTENER 12" O.C. PLYWOOD SHEATHING MEMBRANE ROOFING DMI FP1511 PANEL PLYWOOD SHEATHING COPING WITH WOOD SUBSTRATE FR10-V-04-00

SEE DMI DYNACLAD EDGE INSTALLATION GUIDE FOR COMPLETE FASTENING AND INSTALLATION INFORMATION FOR ES-1 RATED SNAP-ON COPING (CO) - DYNACLAD EDGE SNAP-ON COPING #9-15 X 1-1/2" SS FASTENER (4 PER CLEAT) MEMBRANE (AC) - ANCHOR CLEAT 1-1/4" SS RING SHANK NAIL #14-13 DP1 PANCAKE HEAD FASTENER 12" O.C. (SJ) - SPLICE JOINT WOOD BLOCKING #10-13 GP PANCAKE HEAD FASTENER 12" O.C. MASONRY DMI FP1511 PANEL COPING WITH FR10-V-04-01

(RG) - RAT GUARD (SLOPED) POP RIVET 12" O.C. ONE CONTINUOUS ROW OF BUTYL TAPE (RW) - RAKE WALL #10-13 GP PANCAKE HEAD FASTENER 12" O.C. SET IN AND CAP WITH APPROVED SEALANT DYNACLAD PREMIUM ROOFING UNDERLAYMENT DYNACLAD ULTRA HT WIND AND WATER SEAL UNDERLAYMENT (EXTEND UP WALL 8" MIN.) DMI ROOF PANEL (5/8" MIN.) PLYWOOD SHEATHING (JC) - J CLOSURE 2" PLYWOOD SHEATHING #10-13 GP PANCAKE HEAD FASTENER 12" O.C. RAKE WALL FR10-V-05-00

UPPER FR10 PANEL #10-13 GP PANCAKE HEAD FASTENER 12" O.C. (SI) - SILL SUPPORT WOOD FRAMING CAULKING WINDOW, LOUVER OR DOOR FRAME (CO) - COPING #10-13 GP PANCAKE HEAD FASTENER 12" O.C. LOWER FR10 PANEL WOOD FRAMING SUPPORT WOOD FRAMING WINDOW, LOUVER OR DOOR FRAME CAULKING #10-13 GP PANCAKE HEAD FASTENER 12" O.C. (JC) - J CLOSURE OPENING HEAD, SILL AND JAMB FR10-V-06-00

MEMBRANE ROOFING HIGH PROFILE EDGE CAULK BAR COVER TAPE #10-13 GP PANCAKE HEAD FASTENER 12" O.C. HIGH PROFILE EDGE CAULK #14-13 X 1 1/2" PANCAKE HEAD FASTENER 30" O.C. FASTENERS TO PENETRATE WOOD SHEETIN (GS) - DMI CONTINUOUS GUTTER STRAP 30" O.C. MAX. (GU) - DMI CONTINUOUS GUTTER POP RIVET (EIGHT PER OUTLET) SEALED WITH NOVA FLEX SEALANT (DS) - DOWNSPOUT (DR) - DROP PLYWOOD SHEATHING #10-13 GP PANCAKE HEAD FASTENER 12" O.C. (RG) - RAT GUARD MEMBRANE ROOFING WALL SECTION AT MEMBRANE ROOF FR10-V-07-00

FP CLIP 24" O.C. MAX FASTENER INTERLOCK PANEL-2 INTO THE HEM OF PANEL-1 PANEL-1 AS SHOWN PANEL-2 DIRECTION OF INSTALLATION PANEL JOINT FR10-V-08-00

FIELD TAB HEAD FLASH JAMB FLASH SILL FLASH FR10 INTERSECTION OF HEAD, JAMB AND (SI) - SILL FLASH ISO HEAD, SILL AND JAMB FR10-V-09-00