Technical Bulletin SSG 5.1

Similar documents
SPACER APPLICATION: KEY POİNTS FOR HİGH QUALİTY İG UNİTS

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL PIONEERING INSULATED METAL PANEL TECHNOLOGY

Extruded sheet (FF) #3 Other Methods of Cutting. Technical information. This brief gives advice for:

OptiLiner Banded Liner System Bi-Directional Banding

Features & Benefits: For Use with OSI QUAD Window & Door System. Recommended For:

window installation Guide wood FRaMinG New Construction

Schluter -DITRA-HEAT Repair procedure for the DHE-HK Heating Cable

Profile Wrapping. TKH-Technical Briefing Note 6. Industrieverband Klebstoffe e.v. Version: March 2009

Splashback Installation Instructions

DAP Latex Window Glazing

Installation Instructions Recommended Tools

OptiLiner Banded Liner System Bi-Directional Banding

Application of Air & Water Barrier Using Sprayers and Power Rollers TDS 410M

METHOD STATEMENT. Sika FloorJoint S

SINKS AND LAVATORIES. Steps to completion: These items are essential for installing all sinks:

300C6 CONTINUOUS HINGE SEMI-FRAMELESS DOOR KIT

Rev. 05/16 01 ACRYLIC INSTALLATION GUIDE

How to Build an Advanced Composite Clipboard

IMPORTANT: This product cannot perform its intended function if not properly installed.

Technical Information

Welding & Fabrication Tools FT-Flat Electrode Welding

Field Installed Connectors for TraceTek 7000-HUV Bulk Cable Installation Instructions

CIRRUS AIRPLANE MAINTENANCE MANUAL MODELS SR22 AND SR22T CHAPTER 56-30: DOOR GENERAL. Door 56-30: DOOR. 1. General

Panel Guard Installation For Adhesive Attachment

Eagle clad double-hung window installation instructions

Adhesive Selection. 1/32 x 1/16 x 1/32 U-notch 4 Gallon 880-1,040 SF 40.0 P u u u. 1/32 x 1/16 x 1/32 U-notch 4 Gallon 1,200-1,400 SF 40.

Tools required by installer: Materials required by installer:

Installation Guide for E-Series/Eagle Clad Mechanically Fastened Windows

IMPORTANT: One Corner Entry Shower Door requires two cartons.

ASS 70 FD folding / sliding door. Installation Guide

INSTALLATION MANUAL STORAGE

MICHAEL RIZZA COMPANY Premium Silicone Systems

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions

TOOLKIT PART 4 MANUFACTURING PROCESSES

Panel Installation Instructions

Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR

LuxCore Installation Instructions

INSTALLATION GUIDE Twinback

Technical Data February, 2016

INSTALLATION GUIDE SLIMLINE ROOF LANTERN 4 PANE CONFIGURATION

Installation Instructions for Vista Air Vertically Folding Walls

UNCONTROLLED 3 STANDARD PROCEDURES FOR PREPARING 33KV CABLES

3M Impact Protection Profile Installation System Instructions

B. Sequencing: Schedule installation to keep sheathing exposure to UV within the manufacturer s recommended limits.

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

THE B6 HEEL BEAD SEAL SECURITY GLAZING SYSTEM

Installation Guidelines. Next Dimension. Single Hung / Single Hung Fixed / Double Hung / Sliding Window / Fixed Window

340 & 350 SERIES BATH ENCLOSURES

Block Frame Inovo Patio Door/Transom/Sidelite Field Mulling Instructions. simonton.com/installation. If mulling sidelites, skip to Step 5.

BASIC TOOLS AND MATERIALS NEEDED. Introduction HOW TO CARE FOR YOUR DOOR

Final Polish of Fiber Optic Connectors using 3M Lapping Films 863X and 863XW on Seikoh Giken SFP-550 Polishing Machines

Curium 19.4H Installation Instructions & Parts List

890 SERIES PIVOT STEAM DOOR

*Before starting, please read entire manual *Changes can be made in order for this manual to work for you. 3 x 6 I-Beam

Curium 19H Installation Instructions & Parts List

3 Simple Steps to a Beautiful Tile Surface. Tec Skill Set How-To Project Guide Floor Tile 1. PREPARE THE SURFACE 2. SET THE TILE. Reverso en español


Frameless Inline Door With Return QCI5263

Flushglaze For Framed Openings and Horizontal Panels. Window System Installation Guide

340 & 350 SERIES DELUXE FRAMELESS BYPASS

CONTENTS OVERVIEW. For a complete set of CAD drawing details, please visit LaminatorsInc.com. 1 Essential Equipment. 1 Essential Supplies

INSTALLATION GUIDELINES: X25 SERIES using perimeter installation fin

Bob Willis Process Guides

Contents. Stage 1. Preparation of the aperture 9. Interior finishing 25

Controltac Plus. Graphic Film RG Product Bulletin RG Description. Compatible Products. For Piezo Ink Jet Printing Only

Fletcher F-3000 / F-3100 Accessory Laser Kit

VERSION 1.7 PRT-ES USER GUIDE. ZiPPERTUBiNG CO. THE. (480)

ASS 70 FD folding/sliding door installation guide

Dicing Through Hard and Brittle Materials in the Micro Electronic Industry By Gideon Levinson, Dicing Tools Product Manager

(Non Handed Kits) Slotted Hand Screwdriver. Power Driver & Bits. Work Gloves

Access Hatch. Installation Instructions and Operators Manual. PS DOORS Contact Information. Model AH-710 Standard High Neck Radius Cut

3M Air and Vapour Barrier 3015 Technical guide

Better by Design: Guidelines for Designing the Perfect Plated Piece

T-GRID SYSTEM WIDE CLEANROOM CEILING GRID SYSTEM

4. Partially open the operating panel and tilt the top toward the interior of the door (Figure 4). Lift the panel off the sill and set it aside.

Induction Heater Coil Kit Compact low voltage, high current induction coil

A. Provide a comprehensive guide to the products that are used when flashing, what they are used for, and the proper way to use them.

FOLDING DOOR - FOR FACTORY ASSEMBLED JAMBS WITH APPLIED SILL

INGROUND COVER INSTALLATION GUIDE

STEADY HAND GAME WITH LATCHING LED

Installation Instructions

ANCHOR PLATE ATTACHMENT STEEL STUD FRAMING OR FURRING CONSTRUCTION WITH ACCESS FROM PANEL SIDE ONLY

Series Sloped glazed Curtain wall. Installation Instructions

NAIMA. Insulation Between (filling) Purlins and Over Purlins. What Does Metal Building Insulation Do? Installation Instructions for New Construction

Installation Instructions

Tools Required: Steps to completion:

Please read and understand all instructions before beginning. These instructions cover the non-impact aluminum sliding glass door.

791 SERIES STIKSTALL TM SHOWER ENCLOSURE

Butyl Flash. Installation Instructions. Prep & General Conditions

Frameless Inline Door QCI5248

WINDOW REPLACEMENT INSTRUCTIONS FOR CASEMENT, DOUBLE-HUNG AND CLAD FRAME WINDOWS USING FRAME SCREWS

Installation Guide. for E-Series/Eagle Clad Hinged Inswing French Door

Contents. pages 20-24: Installing Edge sinks into. custom laminate countertops page 8: Installing Edge sinks into postform laminate countertops

Installation Guidelines

FABRICATION MANUAL CCM Copper Composite You discover why ALPOLIC Copper composite material (CCM) is the building material of the future as soon as

STACKING MULTI-SLIDE DOOR SYSTEM

Installation Instructions for New Construction. Installation Instructions for New Construction

Structural adhesive benefits with hot melt adhesive speed for wood, plastic, and more. 3M Scotch-Weld Polyurethane Reactive (PUR) Adhesive Systems

FITTING INSTRUCTIONS FOR OFD SOLID OAK FLOORING

Installation tutorial for Console Customs PS3 TrueFire Standard Rapid fire Microchip for Sixaxis and Dualshock 3 controllers

Transcription:

Technical Bulletin SSG 5.1 EnerSEAL 332 Manual Hot Melt Application Guide Application note: EnerSEAL 332 can be processed on any standard HOT MELT extrusion machine currently used in the insulating glass industry. The product must be applied on a clean and dry substrate. The product must completely fill the sealing gap down to the spacer (no air pockets). Care should be taken on sealing each corner and sealant should be pressed together while still molten by means of an ENAPAD2 502 troweling pad to prevent any gaps, holes and cold joints in sealant at corners, which can lead to premature unit failure. In case of a single seal IG unit glass/spacer bar assembly must be tightly maintained (clips, clamping table) during EnerSEAL 332 application. The minimum depth required of the sealing joint is >3/16 (4.76 mm). Recommended extrusion temperature: +347 F (175 C) to +365 F (185 C). It is important that sealant is applied within recommended temperature range, so it is advisable that application temperature be checked daily with a digital thermometer at gun nozzle while gunning sealant. Limitations: Be sure that units fabricated with EnerSEAL 332 are glazed in accordance with industry glazing guidelines such as IGMA s TM-3000. Never apply to wet or contaminated surfaces glass and spacer bonding surfaces should be clean and dry prior to sealant application. Never dispense and apply in confined areas, without adequate ventilation. Always use in application fill depths sufficient for customer s intended performance life. In no cases should design fill depth be <3/16 nominal. Coated glass may require edge deletion, so consult your glass supplier for their recommendations. Deletion should cover full depth of sealant pocket, with deletion line targeted to be midway within the spacer height. 1

1. Equipment Preparation and Set-up: a. Equipment should be suitable for the intended purpose i.e. capable of heating EnerSEAL 332 to a temperature of 365 F (185 C) as measured when dispensed. b. For better handling a smaller diameter 5/8 ID hose is recommended: i. Make sure the heated hose is of sufficient length to apply hot melt to the largest IG unit size made. ii. Consider hose support devices to reduce strain on the applicator. c. Make sure hot melt pumps Set Point temperature is high as possible without slumping at gunning tip. i. Set point temperatures are typically not accurate. Observe hot melt flow and measure extruded hot melt as it exits gun tip. ii. Recommended extrusion temperature: +347 F (175 C) to +365 F (185 C). d. Glass racks should have silicone strips on base to prevent units sticking; Contact Tremco for a source. 2. Dispensing Gun and Brass Nozzle Tips: a. To reduce heat loss, eliminate any extended pipe on dispensing gun. b. To maximize hot melt flow and wet-out and to increase tooling time: i. The nozzle tip face should be flat not concave (reference pictures below). ii. Nozzle tip face should be smaller i.e. use 3/8 tip for 1/2 cavity. c. Design triple pane nozzle tips for each major combination of glass and spacer. Flat nozzle tip Concave nozzle tip Short pipe 2

3. Hot Melt Application: a. Before applying EnerSEAL 332 the IG units should be prepared per the EnerEDGE Application Guide. b. Topped unit must be compressed to fully wet-out acrylic adhesive. c. Mylar sealing tape: i. Apply to 4th corner and any pierced holes as indicated in the EnerEDGE Application Guide (see link above). 1. Make sure mylar sealing tape is not adhered to inside glass surfaces. d. Don t apply from a cold gunning tip. i. Confirm temperature is in range as indicated above. ii. Purge to get hot sealant before starting application. iii. Set gun in a heated cradle or cured silicone holster. e. Start application at start-finish point or 4th corner for argon filled units. i. Apply hot melt continuously along each side and the corners. Make sure it flows into and fills the cavity. ii. Eliminate any cold-joints and voids by pinching hard at all four corners. 1. Use Tremco Troweling Pads (ENAPAD2 502) to facilitate this process. Typical rotation for hot melt application Eliminating cold joints and voids 4. Post Application Inspection: a. Inspect in a bright, well-lit area. b. Inspect all 4 corners, top and bottom sides: i. Spot check blind surfaces 3 & 4 on triple-glazed units when establishing quality, new operators, etc. 5. Examples of Poor Quality Sealant Application: Cold joint/void Thin sealant application Sealant blow by 3

BUTTERFLY ADHESION TEST Objective: This test method is designed to evaluate the adhesion of Tremco EnerSEAL 332 and/or other high quality hot melt butyl sealants to glass and spacer materials. Please follow all safety procedures specified for handling raw cut glass and hot applied sealants. 1. Randomly select a production unit, or make one, preferably no larger than 24 x 36 (610 mm x 914 mm) and with glass thickness less than 3/16 (3 to 4 mm). 2. Allow test specimen if recently made to cool, then sit for 16-24 hours at 72 ±5 F (22 ±3 C). Avoid situations where seasonal temperatures are hotter or colder than the conditions above. In that case store the specimen in an office or other temperature controlled environment. 3. Do not break the glass with a hammer; cut the glass with a glass cutter as follows: a. cut glass corner-to-corner X on one side; b. b reak glass under tension; (see photo below) c. cut glass to remove the point of one of the four triangles so 2 to 4 inches (50 to 100 mm) remain. d. break glass under tension and; e. cut a 4 to 7 (100 to 175 mm) section from Step (d). 4. For thermoplastic hot melt products, slowly (5 to 6 sec) pull and rotate the glass 180. A slow steady motion is essential. 5. For reactive hot melt (RHM) products, slowly (5 to 6 sec) pull and rotate the glass 45. A fast pull may cause adhesion loss due to the high cohesive strength of these products. 6. Observe and record adhesion of sealant to glass and spacer. Step 3a Step 3b Step 3c and 3d Step 3e Step 4 Step 5 4

Pass/Fail Criteria: All sealants should maintain adhesion to glass and spacer material during the test. Cohesive failure of the sealant is acceptable. For reactive hot melt, high cohesive strength may cause adhesive failure if over stretched. Record Results: For IGMA/IGCC/NAMI compliance adhesion test results should be logged. Include manufacturer code, bath or lot number and date of test. For failed tests, record corrective action taken. Warranty: Tremco warrants its Products to be free of defects in materials, but makes no warranty as to appearance or color. Since methods of application and on-site conditions are beyond our control and can affect performance, Tremco makes no other warranty, expressed or implied including warranties of MERCHANTABILITY and FITNESS FOR A PARTICULAR PURPOSE, with respect to Tremco Products. Tremco s sole obligation shall be, at its option, to replace, or refund the purchase price of the quantity of Tremco Products proven to be defective and Tremco shall not be liable for any loss or damage. 5

ENEREDGE ENHANCED GAS FILLING METHOD Process to Seal and Fill: 1. Apply EnerEDGE spacer in the normal fashion. a. O ptionally apply mylar tape to spacer s 4th corner intersection as best practice. 2. Top and press IGU assembly in roller press, in the normal fashion. 3. Apply hot melt sealant completely around all perimeter s sides, including over the spacer s 4th corner. See EnerSEAL 332 application guide above. a. P inch 4 corners to eliminate cold joints per current practices. b. W hile just-applied hot melt is still hot and IGU is in an accessible position, come 1 to 2 away from corner area and scoop away a short 1 to 2 section of the secondary sealant, and trowel out material to mylar. Step 3b Hot melt removed to vapor barrier Teflon stick to scoop hot melt 4. Rack IGU and gas fill using the following procedure. Note: these steps are shown below without sealant for clarity. a. U sing a sharp blade slice into spacer as indicated below (Step 4a). b. U se FDR awl and bushing kit to pierce spacer as indicated below (Step 4b). c. L eave FDR bushing in spacer for use with gas filling lance as indicated below (Step 4c). 5. Gas fill and patch with hot melt. Since the area where hot melt is removed still has just-gunned hot melt at the glass-spacer-sealant contact area (triple point), the potential effect of cold joints creating a sealant void is greatly diminished, as is argon loss. Step 4a Step 4b Step 4c Please contact Tremco Technical Service at 866-209-2404 with any questions regarding this bulletin. 12/14/2017 6