A Reflectometer for Cable Fault Location with Multiple Pulse Reflection Method

Similar documents
THE PROPAGATION OF PARTIAL DISCHARGE PULSES IN A HIGH VOLTAGE CABLE

Chapter 12: Transmission Lines. EET-223: RF Communication Circuits Walter Lara

International Journal of Current Research and Modern Education (IJCRME) ISSN (Online): & Impact Factor: Special Issue, NCFTCCPS -

Exercise 1-2. Velocity of Propagation EXERCISE OBJECTIVE

Experiment No. 6 Pre-Lab Transmission Lines and Time Domain Reflectometry

Practical aspects of PD localization for long length Power Cables

TD-106. HAEFELY HIPOTRONICS Technical Document. Partial Discharge Pulse Shape Analysis to Discriminate Near and Far End Failures for Cable Location

Enhanced Locating Method for Cable Fault Using Wiener Filter

Cable Shielding. Lucas Thomson, Dr. Brian Jones, Dr. Cynthia Furse

Simplified Approach to Calculate the Back Flashover Voltage of Shielded H.V. Transmission Line Towers

Lightning transient analysis in wind turbine blades

FAULT DETECTION, CLASSIFICATION AND LOCATION ON AN UNDERGROUND CABLE NETWORK USING WAVELET TRANSFORM

Signal Characteristics

Investigation of PD Detection on XLPE Cables

MAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI UNIT II TRANSMISSION LINE PARAMETERS

Pulse Transmission and Cable Properties ================================

Partial Disconnected Cable Fault Detection Using Improved SSTDR

Comparing Wave Propagation Characteristics of Various Smart Electricity Distribution Networks Murtaza Hashmi, Ruslan Papazyan, Matti Lehtonen

EXPERIMENTAL INVESTIGATION OF A TRANSIENT INDUCED VOLTAGE TO AN OVERHEAD CONTROL CABLE FROM A GROUNDING CIRCUIT

Design and experimental realization of the chirped microstrip line

The quality of the transmission signal The characteristics of the transmission medium. Some type of transmission medium is required for transmission:

Calculation of Transients at Different Distances in a Single Phase 220KV Gas insulated Substation

A Self-diagnostic Method for the Electrode Adhesion of an Electromagnetic Flow-meter

Development of a Prototype of a GSM based Underground Cable Fault Detector

Amateur Extra Manual Chapter 9.4 Transmission Lines

Simulation of line fault locator on HVDC Light electrode line

The Principle V(SWR) The Result. Mirror, Mirror, Darkly, Darkly

Time Domain Reflectometry (TDR) and Time Domain Transmission (TDT) Measurement Fundamentals

FAULT IDENTIFICATION IN TRANSFORMER WINDING

Investigation of Inter-turn Fault in Transformer Winding under Impulse Excitation

Calculation of Transient Overvoltages by using EMTP software in a 2-Phase 132KV GIS

Long lengths transmission power cables on-site testing up to 500 kv by damped AC voltages

Effect of Shielded Distribution Cables on Lightning-Induced Overvoltages in a Distribution System

Timing Error Analysis in Digital-to-Analog Converters

A Few (Technical) Things You Need To Know About Using Ethernet Cable for Portable Audio

Suppression of Pulse Interference in Partial Discharge Measurement Based on Phase Correlation and Waveform Characteristics

Electrical Power Engineering Group, School of Electronics and Computer Science, University of Southampton, Highfield, Southampton, SO17 1BJ, UK 2

(i) Determine the admittance parameters of the network of Fig 1 (f) and draw its - equivalent circuit.

A Broadband High-Efficiency Rectifier Based on Two-Level Impedance Match Network

Measurement of Surge Propagation in Induction Machines

International Journal of Advance Engineering and Research Development. Comparison of Partial Discharge Detection Techniques of Transformer

Chapter -3 ANALYSIS OF HVDC SYSTEM MODEL. Basically the HVDC transmission consists in the basic case of two

ECE2019 Sensors, Signals, and Systems A Lab #6: Electromagnetic Field Sensing

Prediction of Transient Transfer Functions at Cable-Transformer Interfaces

Coherence and time-frequency analysis of impulse voltage and current measurements

Effect of Shielded Distribution Cable on Very Fast Transients

Ground Penetrating Radar

Pre location: Impulse-Current-Method (ICE)

Simulation and Analysis of Lightning on 345-kV Arrester Platform Ground-Leading Line Models

Lab 1: Pulse Propagation and Dispersion

15 th Asia Pacific Conference for Non-Destructive Testing (APCNDT2017), Singapore.

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

Close and Distant Electric Fields due to Lightning Attaching to the Gaisberg Tower

Alternative Coupling Method for Immunity Testing of Power Grid Protection Equipment

Effect of Aging on Power Integrity of Digital Integrated Circuits

GIS Disconnector Switching Operation VFTO Study

ETL-40V CABLE TEST VAN SYSTEM. tel.: +380 (57) fax: +380 (57) high voltage testing equipment

AN IMPROVED MODEL FOR ESTIMATING RADIATED EMISSIONS FROM A PCB WITH ATTACHED CABLE

Enhancement of Fault Current and Overvoltage by Active Type superconducting fault current limiter (SFCL) in Renewable Distributed Generation (DG)

Wideband Channel Measurements and Modeling for In-House Power Line Communication

Fault Location Technique for UHV Lines Using Wavelet Transform

Design of leaky coaxial cables with periodic slots

A Simple Wideband Transmission Line Model

Multi-Resolution Wavelet Analysis for Chopped Impulse Voltage Measurements

A Compact Miniaturized Frequency Selective Surface with Stable Resonant Frequency

Design of Meander Antenna for UHF Partial Discharge Detection of Transformers

Neutral Reactor Optimization in order to Reduce Arc Extinction Time during Three-Phase Tripping

Signal Integrity Testing with a Vector Network Analyzer. Neil Jarvis Applications Engineer

ENERGY CABLE MODELING UNDER POWER ELECTRONIC CONVERTER CONSTRAINTS

Analysis of Distance between ATS and ATP Antenna for Normal Operation in Combined On-board Signal System

Application Note # 5438

EFFECT OF INTEGRATION ERROR ON PARTIAL DISCHARGE MEASUREMENTS ON CAST RESIN TRANSFORMERS. C. Ceretta, R. Gobbo, G. Pesavento

Power Electronics. Exercise: Circuit Feedback

Software for Partial Discharge and Localization

Validation & Analysis of Complex Serial Bus Link Models

MAHALAKSHMI ENGINEERING COLLEGE

Contents. Telecom Service Chae Y. Lee. Data Signal Transmission Transmission Impairments Channel Capacity

Agilent Time Domain Analysis Using a Network Analyzer

High voltage amplifiers and the ubiquitous 50 Ohm: Caveats and benefits. Falco Systems application note, version 1.0,

Lab Manual Experiment No. 2

Bill Ham Martin Ogbuokiri. This clause specifies the electrical performance requirements for shielded and unshielded cables.

How to Analyze and Test the Location of Partial. Discharge of Single-winding Transformer Model

Development of Bolt Crack Detection Device Based on Ultrasonic Wave

a) Basic unit of an ideal transmission line b) an ideal transmission line

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Industrial Electronics

Effect of High Frequency Cable Attenuation on Lightning-Induced Overvoltages at Transformers

Lecture Fundamentals of Data and signals

VLSI is scaling faster than number of interface pins

PARTIAL DISCHARGE DETECTION AND LOCATION IN TRANSFORMERS BY PERFORMING PARTIAL DISCHARGE TESTS IN OIL USING UHF SENSORS

Final Report for AOARD Grant FA Indoor Localization and Positioning through Signal of Opportunities. Date: 14 th June 2013

Improving CDM Measurements With Frequency Domain Specifications

Transmission Lines and TDR

Telecommunication Wiring Questions

Ultra Hight Voltge Transmission line Faults Identified and Analysis by using MATLAB Simulink

Optimization of Axial Resolution in Ultrasound Elastography

Modeling and Simulation of Powertrains for Electric and Hybrid Vehicles

TileCal Analogue Cable Measurement Report

Analysis of Collided Signal Waveform on the Long Transmission Line of UART-CSMA/CD Control Network

Technician License Course Chapter 4. Lesson Plan Module 9 Antenna Fundamentals, Feed Lines & SWR

Vibrating Wire Instrumentation

Transcription:

2014 by IFSA Publishing, S. L. http://www.sensorsportal.com A Reflectometer for Cable Fault Location with Multiple Pulse Reflection Method Zheng Gongming Electronics & Information School, Yangtze University, Jing Zhou, 434023, China E-mail: zgm831@gmail.com Received: 4 August 2014 /Accepted: 30 October 2014 /Published: 31 December 2014 Abstract: In this paper, the studies of finding the failure location on a sample cable by using the multiple pulse reflection method and the fault on the results of the measurement have been examined. A pulse generator with amplitude of 12 V and pulse width from 20 ns to 2 us has been designed as a multiple pulse reflection meter. The velocity of reflection pulse is calibrated in embedded system. The SOPC system detects the reflection pulse and measures the time of N times reflection pulses, then judge the fault type and compute the fault distance with corrected speed of pulse developed for measurement of pulse reflection by means of pulse velocity correction and have been examined here. Copyright 2014 IFSA Publishing, S. L. Keywords: Fault detection, Cable fault location, Pulse multiple reflection, embedded system, SOPC. 1. Introduction Cable as an important transmission media, widely used in the important field of instrument and meter, electric power, communication, exploration etc. Cable fault occurs, not only affect the daily life but also the production. The importance of aging electrical wiring and associated faults of cable has been highlighted in [1] to [5]. The studies of finding the fault location on cables got started with the method of bridge suggested by Murray [1]. In this method, the resistances of the junction points and the sensitivities of galvanometers affect the accuracy of the measurement. HDW Electronics suggested secondary impulse method which is based upon investigating the traveling waves. In this method, the short circuit occurring at the point of failure as soon as there, occur an arc here can be found with a low voltage pulse reflection signal sent to the cable. However, the fact that the arc lasts for a short time during the measurement decreases the accuracy of the measurement of pulse reflection especially with long lines [6]. This method suggests that the reflections of arc established by a pulse generator at the point of fault are examined through an inductive coupling element and thus the point of fault is found. This method has made it possible to find out the fault location with a high rate of accuracy independently of the parameters related to the fault [7]. In this study, a low voltage pulse reflectometer has been developed in order to find the fault location according to the pulse reflection method with the cables and the experiments based upon finding the points of failure have been carried out on a cable. The pulses applied at the beginning of the cable and that are reflected from the point of fault have been captured and counter for SOPC system to estimate the fault type and locate the failure point distance screening on the LCD screen and the results have been examined here. 2. Pulse Reflection Method Pulse reflection method is an efficient method that eliminates the needs such as extra junctions, a 8 http://www.sensorsportal.com/html/digest/p_2511.htm

healthy core, or complicated calculations arising in the classical preliminary position finding methods that are carried out with bridge circuits. In this method, a pulse is sent from one end of the faulty cable. This pulse reflects completely or partially from any impedance change occurring on the cable. Distance of the point where the impedance changes, is guessed considering the period that lasts between the exit of the pulse from the source to the return of pulse to the source and the propagation velocity of the pulse [1]. The point of failure is calculated as in Eq. (1): L = V t /( 2N ), (1) terminal of the cable, V is the velocity of the propagation of the pulse; t is the time of the pulse N times reflection, N is the reflected times. The propagation velocity can be defined as the speed of propagation of energy in a certain environment. Each cable has its own speed of propagation changing according to the qualities of the material. The propagation velocity is calculated with the equation stated below: V = / ε, (2) V S where V is the velocity of propagation of the pulse, Vs is the velocity of propagation of the light in space, ɛ r is the relative dielectric constant of the cable insulator. 2.1. Investigating the Characteristics of the Fault The cables are generally modeled with an R resistance, L inductance, C capacitance between the conductors or conductor-shield and G conductance [4]. In a circuit which is modeled in this way, inductance and resistance are in series connection while capacitance and conductance are in parallel connection. Equivalent circuit diagram for a cable is shown in Fig. 1. r the current i which is induced is called as the characteristic impedance (Z 0 ) of the cable and it is written as below: Z u = = i R + jωl G + jωc 0 (3) Generally, Z c is complex, not only the amplitude, and phase changes. Phase variation reflects the cable characteristic impedance of the inductive or capacitive properties. As the launch a high_frequency signal, R<<jωL, G<<jωC, the cable characteristic impedance will be as flow: Z C L / C =, (4) where Z c is the surge impedance, L is the inductance, C is the capacitance. The characteristic impedance is not based upon the length of line as it can be seen at the Eq. (4). 2.1.1. Reflection and Transmission Coefficient As the transmission line considered as uniform distributed parameter elements, the impedance of cable is same when a wave propagates along the wire, but the wave impedance will change and voltage current traveling along the wire mismatch the transmission condition, when the waves propagate into the end of the line or arbitrary impedance mismatch point. As an example of circuit, the electromagnetic wave to the terminal, which can t continue to spread, and no load acceptance of energy, so the electromagnetic wave only by the line terminal to the starting end echo, echo phenomenon caused by the transmission line impedance mismatch is the reflection. 2.1.2. Breaker / Circuit Fault The occasion when the cable is completely broken is seen in Fig. 2. In this case, all the energy of the pulse reflects back to the source as the impedance of the point of failure will be infinite. With a cable which has an -circuit at the end of the cable, the impedance of fault point Z is infinite, so reflection coefficient as flow: Fig. 1. The diagram of Cable lumped parameter circuit. The ratio of the voltage e, induced by the pulse applied to the cable while it is running on the cable to I=I r +I f =0 ---> ρ i =I r /I f =-1 U r =-Z c I r U=U f +U r =Z c (I f -I r )=2U f ---> U f =U r ρ v =U r /U f =1 9

Fig. 2. The reflection pulse of -fault cable. Therefore, when the cable is fault, the reflected voltage and launch signal have same polarity; reflection signal current is opposite to emission signal. 2.1.3. Short Circuit Fault When the transmission cable short circuit fault occurs, the fault point impedance Z0 is 0, so the fault point voltage U is 0 too, namely U r =-Uf. Voltage reflection coefficient: ρ v is -1. so reflection coefficient as flow: U=U r +U f =0 ---> ρ v = U r /U f =-1 I r =-U r /Z c I=I f +I r = (U f -U r )/ Z c =2I f ---> ρ i = U r /U f =1 Means when the cable is short fault, the reflected voltage and launch signal have opposite polarity; reflection signal current is same to emission signal. Show in Fig. 3. shortcomings and defects of. According to the principle of pulse emission, electromagnetic pulse signals occur multiple reflections in the fault, generating multiple echo effect, and the reflection coefficient of the same type of fault point are the same, just because the cable distribution resistance, capacitance of the pulse amplitude decreases gradually, as shown in Fig. 2 and Fig. 3. Therefore multiple pulses can be collected on the fault cable transmitter. Due to the propagation speed pulse signal in the cable is very fast, this caused the interval pulse time between two reflection pulses is so short. If a single echo detection method to achieve high test accuracy, the system needs to improve the sampling frequency (above 500 MHz). It puts forward a very high request to the hardware system, multiple reflection detection method is the echo acquisition and analysis, thus extending the system response to the echo time, reduces system acquisition speed requirements in the same test accuracy. Multiple echo detection method can effectively improve the resolution and accuracy of test system, and reduce the hardware overhead. Multiple echo detection method is mainly used to detect and locate the fault type. Follow the principles in the process of testing: First, transmits a narrow pulse signal to the cable, and detects the multiple reflected pulses; second, amplifies, shapes and samples to multiple echo signal and send the captured signal to processor; third, the processer timing the interval time of N multiple reflection pulse with system clock, then send and latch the counter to calculate the distance of fault point; finally, determine the fault type with comparing whether negative voltage pulse. As shown in Fig. 4, circuit detection, since the reflection coefficient is 1, reflected pulse polarity is the same to launched pulse, just as show in Fig. 3, the negative voltage comparative shaping circuit without pulse signal, then determines the fault type for circuit breaker or. Fig. 3. The reflection pulse of short-fault cable. 2.2. Pulse Multiple Reflection Multiple reflection method is the reflection principle of time domain reflection (TDR) on the basis of single echo detection method, aiming at the Fig. 4. Multiple echo detected -cable. Short circuit fault testing principle and process is same to circuit. Due to short circuit fault point the reflection coefficients is -1, the reflected pulse and emission pulse is opposite polarity, so the echo 10

waveforms showing positive and negative pulse alternatively, just as Fig. 4. Specified number of interval echoes is counted, then locate the failure point, because the negative comparative shaping circuit get pulse signals, determine the fault type for short circuit, as shown in Fig. 5. terminal of the cable, L 1, L 2 are the two known cable lengths, V is the velocity of the propagation of the pulse, f is the frequency of counter clk, N is the reflected times, M 1, M 2 are the value of counter for L1, L2. 3. Embedded System Within the framework of the experimental study, a multiple pulse reflectometer has been designed and measurements have been carried out on the cables for various occasions of faults. The results of the measurements have been examined. The general image of the pulse reflection meter is shown in Fig. 6. The experimental circuit is composed of three different sub-systems. These systems include FPGA, pulse generator and data sample. Fig. 5. Multiple echo detected short-cable. Using multiple reflection method to fault detection, fault location calculation formula as flow: L M V 2Nf =, (5) terminal of the cable, V is the velocity of the propagation of the pulse, f is the frequency of counter clk, N is the reflected times, M is the value of counter. 2.3. Velocity Correction The velocity of pulse propagation is directly affects the accuracy of the detection. Although the velocity of propagation of the pulse can be determined by Eq. (2), The different cable in different system, the speed of reflected pulse V is needed to be corrected. Therefore, the velocity of pulse propagation is been needed for calibration. because of Eq. (5), the calibration step as follows: Two known different lengths were L 1 and L 2 homogeneous cable, then measured the time interval reflection while circuit in the embedded system, got the standard clock counter is M 1 and M 2 respectively, then the inherent delay time t delay of system, and velocity of pulse propagation V can be determined as flow: L= ( M1 V/(2* N) 2* N* L1 2* N* L2 V = = ( M1 ( M2 ( M2 / f * L1 M1 / f * L2 ) tdelay=,( L ) ( ) 1 > L L L 2, 1 2 (6) Fig. 6. The embedded system scheme. The pulse generator produces square wave signals from 20 ns to 2 us with amplitude of 12 V and 100 Hz to be sent to the cable by the pulse reflection meter by ADG201.The pulse generator to be used in the experimental study has been controlled by FPGA owned by the company of ALTERA. As the processor, the fast processor of EP3C16Q240C8 has been used. 4. Experimental Study In the experimental studies, the faults established artificially on a point on the cable have been examined by means of using pulse reflection measurements. For this purpose, three cables of 428xl type, twisted-pair and coaxial cable with lengths of 27.3 m 10 m and 101.3 m have been used to test the -circuit and short-circuit. Fig. 7 is the detected circuit 6 times reflection in Oscilloscope. For this purpose, pulses with changing between 80 ns with a frequency of 100 Hz and amplitude of 12 V have been applied to three of the cables. The results obtained at the end of these measurements are stated in Table 1. 11

to be applied to the cable should be selected in proportion with the length of the cable. References Cable 428xl twiste d-pair coaxia l cable Fig. 7. 6-time reflection capture. Table 1. The measurements of three cable for different fault. 5. Conclusions Fault Velocity Actule Detect Error (mm/ns) Len (m) Len (m) (%) 27.1-0.73 19.8 27.3 short 28.2 3.3 9.9-1.0 14.7 10 short 10.5 5.0 103.9 22.0 101.3 7 2.6 short 105.4 4.1 In this study, a pulse generator that can produce pulses with a constant amplitude but adjustable pulse width has been designed. The measurements carried out for this study have been examined comparatively through the embedded system for multiple pulse reflection measurement. The point of fault could be found easily in a short time by calibrated the velocity of pulse to improve the accuracy of test system. The multiple pulse reflection method gives the most efficient and the fastest results with lowresistance short circuit faults and high-resistance -circuit faults. For the pulse reflection measurement to be efficient and accurate, the energy of the pulse should be higher than the loss taking place on the cable in order for the pulse reflecting from the failure location to reach the source. Pulse width is smaller and the measure blind length is shorter, but the reflection attenuation is more serious, so the width of the pulse and reflection pulse times N [1]. Ho C. M., Lee W. K., Hung Y. S., Signature representation of underground cables and its applications to cable fault diagnosis, in Proceedings of the 2 nd International Conference on Advances in Power System Control, Operation and Management (APSCOM 93), 7-10 December 1993, pp. 861-865. [2]. B. Clegg, Underground Cable Fault Location, McGraw-Hill, New York, 1993. [3]. K. K. Kuan, K. Warwick, Real-time expert system for fault location on high voltage underground distribution cables, Generation, Transmission and Distribution, IEE Proceedings C, Vol. 139, May 1992, pp. 235-240. [4]. M. Kawashiwa, J. Shinagawa, Development of a current detection type cable fault locator, IEEE Trans. on Power Delivery, Vol. 6, No. 2, April 1991, pp. 541-545. [5]. Pintelon R., Van Biesen L., Identification of transfer functions with time delay and its application to cable fault location, IEEE Transactions on Instrumentation and Measurement, Vol. 39, Issue 3, June 1990, pp. 479-484. [6]. Naoki Kurosawa, Haruo Kobayashi, Kaoru Maruyama, Explicit Analysis of Channel Mismatch Effects in Time-Interleaved ADC Systems, IEEE Transactions on Circuits and Systems, Vol. 48, No. 3, 2003. [7]. M. H. Li, M. G. Zhou, Y. M. Qu, Z. Yan, S. Y. Gong, Research on surge arc prolongation device for power cable fault location, in Proceedings of the Electrical Insulation Conference, 23-26 Oct. 2005, pp. 38-41. [8]. Daubechies I., The wavelet transform, timefrequency localization and signal analysis, IEEE Trans Inform. Theory, Vol. 36, No. 5, 1990. [9]. D. K. Cheng, Field and Wave Electromagnetics, Addison-Wesley Publ. Co., Massachusetts, 1983. [10]. J. Livie, P. Gale, W. Anding, The application of online travelling wave techniques in the location of intermittent faults on low voltage underground cables, in Proceedings of the 9 th IET Int. Conf. on Power System Protection, 17-20 March 2008, pp. 714-719. [11]. Guinee R. A., A novel pulse echo correlation tester for transmission line fault location and identification using pseudorandom binary sequences, in Proceedings of the 34 th IEEE Annual Conference on Industrial Electronics (IECON 08), 10-13 Nov. 2008, pp. 1833-1838. 2014 Copyright, International Frequency Sensor Association (IFSA) Publishing, S. L. All rights reserved. (http://www.sensorsportal.com) 12