Analog or Digital Output Position sensor with measuring tape class IP64 (IP67) Measurement range 0... 236.2 in. to 0... 984.3 in. 0... 6000 mm to 0... 25000 mm Steel measuring tape Analog output Redundant version on request Specifications Outputs Resolution Linearity Sensing device Material class Connection Shock Vibration EMC, temperature U2 U8 I1 Voltage 0.5... 10 V Voltage 0.5... 4.5 V Current 4... 20 ma, 3 wire 0.05 mm ±0.05 % f.s. Magnetic encoder Aluminum, stainless steel and plastic; Tape: stainless steel, 0.39 in. wide, 0.004 in. thick IP64 (IP67) Cable output, standard length 2 m EN 60068-2-27:1993, 100 g/11 ms, 100 shocks EN 60068-2-6:1995, 20 g 10 Hz-2 khz, 10 cycles Refer to output specification Order code BAB1 Model name Measurement range (in mm) 6000 / 8000 / 10000 / 12000 / 15000 / 20000 / 25000 Output 1 U2 = 0.5... 10 V signal conditioner U8 = 0.5... 4.5 V signal conditioner I1 = 4... 20 ma signal conditioner Output scalable (as option) PMU Output 2 (as option) Identical to output 1 Connection KAB2M = Cable output, standard length 2 m Dust wiper BAB1 Order example: - 6000 - I1 - KAB2M - BAB1 26 WB-CAT-US-10 ASM Sensors, Inc.
Digital Output Position sensor with measuring tape class IP64 (IP67) Measurement range 0... 236.2 in. to 0... 984.3 in. 0... 6000 mm to 0... 25000 mm Steel measuring tape SSI output or CANopen output or CAN SAE J1939 output Redundant version on request Specifications Outputs Resolution Linearity Sensing device Material class Connection Shock Vibration EMC, temperature Synchronous serial output (SSI) CANopen output CAN SAE J1939 output 0.05 mm ±0.05 % f.s. Magnetic encoder Aluminum, stainless steel and plastic; Tape: stainless steel, 0.39 in. wide, 0.004 in. thick IP64 (IP67) Cable output, standard length 2 m EN 60068-2-27:1993, 100 g/11 ms, 100 shocks EN 60068-2-6:1995, 20 g 10 Hz-2 khz, 10 cycles Refer to output specification Order code BAB1 Model name Measurement range (in mm) 6000 / 8000 / 10000 / 12000 / 15000 / 20000 / 25000 Output 1 MSSI = SSI synchronous serial CANOP = CANopen CANJ1939 = CAN SAE J1939 Output 2 (as option) Identical to output 1 Connection KAB2M = Cable output, standard length 2 m Dust wiper BAB1 Order example: - 6000 - MSSI - KAB2M - BAB1 ASM Sensors, Inc. WB-CAT-US-10 27
Analog or Digital Output Outline drawing -6000 150 [5.906] 39 [1.535] 96 [3.780] 100 [3.937] 53 [2.087] 17,96 [0.707] 85,7 1 [ 3.374 0.039] 13 [0.512] 81,2 1 [ 3.197 0.039] 122 [4.803] 82 [3.228] 12 [0.472] A 3x 46 [1.811] B 50 [1.969] 5 [0.197] 11 [0.433] 57 [2.244] 68 [2.677] 3 [0.118] 33 [1.299] Dimensions in mm [inch] 5 [0.197] 48 1 [ 1.890 0.039 ] 19,2 [0.756] 9 [0.354] Dimensions informative only. For guaranteed dimensions consult factory. Dimensions in mm [inch] Version A B Standard 51.5 [2.03] Redundant 38.65 [1.52] 64.35 [2.53] 28 WB-CAT-US-10 ASM Sensors, Inc.
Analog or Digital Output Outline drawing -8000 159 [6.260] 49,5 [1.949] 106,5 [4.193] A B 50 [1.969] 24,5 [0.965] 100 [3.937] 9,46 [0.372] 5 [0.197] 11 [0.433] 57 [2.244] 68 [2.677] 131 [5.157] Ø100 [3.937] 85,7 1 [ 3.374 0.039 ] 81,2 1 [ 3.197 0.039] 12 [0.472] 3x 53 [2.087] 13 [0.512] 46 [1.811] 5 [0.197] 48 1 [ 1.890 0.039 ] 19,2 [0.756] 9 [0.354] Dimensions in mm [inch] Dimensions informative only. For guaranteed dimensions consult factory. Dimensions in mm [inch] Version A B Standard 51.5 [2.03] Redundant 38.65 [1.52] 64.35 [2.53] ASM Sensors, Inc. WB-CAT-US-10 29
Analog or Digital Output Outline drawing -10000 179 [7.047] 49,5 [1.949] 109,5 [4.311] 9,46 [0.372] A B 50 [1.969] 24,5 [0.965] 100 [3.937] 5 [0.197] 11 [0.433] 57 [2.244] 71 [2.795] 151 [5.945] 100 [3.937] 85,7 1 [ 3.374 0.039] 81,2 1 [ 3.197 0.039] 12 [0.472] 3x 53 [2.087] 13 [0.512] 46 [1.811] Dimensions in mm [inch] 5 [0.197] 48 1 [ 1.890 0.039 ] 19,2 [0.756] 9 [0.354] Dimensions informative only. For guaranteed dimensions consult factory. Dimensions in mm [inch] Version A B Standard 51.5 [2.03] Redundant 38.65 [1.52] 64.35 [2.53] 30 WB-CAT-US-10 ASM Sensors, Inc.
Analog or Digital Output Outline drawing -12000-15000 -20000-25000 2 [0.079] 200 [7.874] 32,5 [1.280] 100,5 [3.957] 8,3 [0.327] zweiter Second Kabelausgang cable output bei for redundanter version Version 143.3 [5.642 ] 128,3 [5.051] 62,5 [2.461] 92,5 [3.642] 75 [2.953] 150 [5.906] 5 [0.197] 11 [0.433] 60 [2.362] 79 [3.110] 83,7 1 [ 3.295 0.039] 79,2 1 [ 3.118 0.039] 176 [6.929] 150 [5.906] 2x 58 [2.283] 49 [1.929] Dimensions in mm [inch] 5 [0.197] 48 1 [ 1.890 0] 19,2 [0.756] 12 [0.472] Dimensions informative only. For guaranteed dimensions consult factory. ASM Sensors, Inc. WB-CAT-US-10 31
U2, U8 and I1 Analog Outputs U2 Voltage output 0.5... 10 V U8 Voltage output 0.5... 4.5 V Excitation voltage Output voltage Output current Measuring rate EMC Excitation voltage Output voltage Output current Measuring rate EMC 18... 36 V DC 25 ma typ. 0.5... 10 V DC 2 ma max. 1 khz standard ±28 x 10-6 / F f.s. (typ.) Reverse polarity, short circuit -40... +185 F (-40... +85 C) EN61326-1:2006-10 10... 36 V DC 25 ma typ. 0.5... 4.5 V DC 2 ma max. 1 khz standard ±28 x 10-6 / F f.s. (typ.) Reverse polarity, short circuit -40... +185 F (-40... +85 C) EN61326-1:2006-10 I1 Current output 4... 20 ma, 3 wire Output signals Excitation voltage 18... 36 V DC (10... 36 V for R L <250 Ω) 35 ma typ. Load Output current Measuring rate EMC 500 Ω max. 4... 20 ma 1 khz standard ±28 x 10-6 / F f.s. (typ.) Reverse polarity, short circuit -40... +185 F (-40... +85 C) EN61326-1:2006-10 Excitation + U2 U8 I1 Signal + GND Signal wiring/ connection Output signal Connector pin Cable wire color Excitation + 1 Brown Signal 2 White GND 3 Blue Do not connect! 4 Black SPAN/ZERO (option PMU) 5 Grey View to sensor connector CONN-M12-5F Option -PMU Programming of the start and end value by the customer Programming of the start value and the end value of the output range is provided by a programming signal SPAN/ZERO available at the connector. This Signal SPAN/ZERO must be connected with GND via a push button, then position magnet of the sensor must be moved to the start resp. the end position. Pushing the button between 1 and 4 seconds sets the actual position as start position, pushing the button more than 5 seconds sets the actual position as end position. The values will be stored and are available after switching off the sensor. To reset the sensor to the factory values the button must be pushed when the sensor is switched on. 32 WB-CAT-US-10 ASM Sensors, Inc.
MSSI SSI Output Interface MSSI Synchronous serial Interface Excitation voltage Clock frequency Code Delay between pulse trains EMC EIA RS-422 10... 30 V DC 100 ma max. w/o load 100 khz... 500 khz Gray-Code, continuous progression 20 µs min. ±28 x 10-6 / F f.s. (typ.) -40... +185 F (-40... +85 C) Short circuit According to EN61326-1:2006-10 Data format (train of 25 pulses) Recommended processing circuit DATA DATA CLOCK CLOCK Transmission rate Cable length Baud rate 50 m 100-400 khz 100 m 100-300 khz Note: Extension of the cable length will reduce the maximum transmission rate. Signal wiring Signal name Connector pin Excitation + 1 Excitation GND 2 CLOCK 3 CLOCK 4 DATA 5 DATA 6 Connection View to sensor connector CONN-M12-8F ASM Sensors, Inc. WB-CAT-US-10 33
CANOP Output CANopen Interface CANOP Specifications Communication profile CANopen CiA 301 V 4.02, Slave Encoder profile Encoder CiA 406 V 3.2 Error Control Node Guarding, Heartbeat, Emergency Message Node ID Adjustable via LSS; default: 127 PDO 3 TxPDO, 0 RxPDO, no linking, static mapping PDO Modes Event-/Time triggered, Remote-request, Sync cyclic/acyclic SDO 1 server, 0 client CAM 2 cams Certified Yes Transmission rates 50 kbit to 1 Mbit, adjustable via LSS; default: 125 kbit Bus connection M12 connector, 5 pins Integrated bus terminating resistor No Bus, galvanic isolated No Excitation voltage 8... 36 V DC 100 ma (typ.) Measuring rate 1 khz (asynchronous) ±28 x 10-6 / F f.s. Repeatability 1 LSB -40... +185 F (-40... +85 C) Reverse polarity, short circuit Dielectric strength 1 kv (V AC, 50 Hz, 1 min.) EMC According to EN 61326-1:2006-10 Signal wiring / connection Signal name Connector pin no. Shield 1 Excitation + 2 GND 3 CAN-H 4 CAN-L 5 View to sensor connector 34 WB-CAT-US-10 ASM Sensors, Inc.
MCANJ1939 Output CAN SAE J1939 Interface J1939 CAN specification Transceiver Communication profile Baud rate Internal temination resistor Address ISO 11898, Basic and Full CAN 2.0 B 24V-compliant, not isolated SAE J1939 250 kbit/s 120 Default 247d, configurable NAME Fields Arbitrary address capable 1 Yes Industry group 0 Global Vehicle system 7Fh (127d) Non specific Vehicle system instance 0 Function FFh (255d) Non specific Function instance 0 ECU instance 0 Manufacturer 145h (325d) Manufacturer ID Identity number 0nnn Serial number 21 bit Parameter Group Numbers (PGN) Configuration data PGN EF00h Proprietary-A (PDU1 peer-to-peer) Process data PGN FFnnh Proprietary-B (PDU2 broadcast); nn Group Extension (PS) configurable Specifications Excitation voltage 8... 36 V DC 100 ma (typ.) Measuring rate 1 khz (asynchronous) ±28 x 10-6 / F f.s. Repeatability 1 LSB -40... +221 F (-40... +105 C) Reverse polarity, short circuit Dielectric strength 1 kv (V AC, 50 Hz, 1 min.) EMC EN 61326-1:2006-10 Signal wiring / connection Signal name Connector pin no. Shield 1 Excitation + 2 GND 3 CAN-H 4 CAN-L 5 View to sensor connector ASM Sensors, Inc. WB-CAT-US-10 35