World-Class Accuracy & Measurement Range (40 Conventional Models)

Similar documents
Wide-band Models from DC to 100 MHz

Wide-band Models from DC to 100 MHz

Wide-band Models from DC to 100 MHz

AC/DC CLAMP METER CM4371, CM4373

STANDBY MODE OFF MODE. POWER HiTESTER. Accurate evaluation of consumption power of electrical products. An Energy Saving Support Tool

DIGITAL HiTESTER 3237, 3238, 3239

INSULATION / WITHSTANDING Test Instrument series 3153/3159/ST5520

Manage Electrode Reaction Resistance, Electrolyte Resistance, and Welding Resistance

POWER HiTESTER 3331, 3332

AC/DC CLAMP METER CM4370 series

AC/DC CLAMP METER CM4370 series

For easy-to-use loggers, look no further! Connect to a tablet, smartphone, or PC for easy, wireless data collection

High-precision portable RESISTANCE METER

Wide Spectrum Power Meter for Comprehensive Device Assessment

A New Series of LCR Meters to Meet Your Applications

AC/DC CLAMP METER AC CLAMP METER CM4000 series

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

DS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices

DS400ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1.5 ppm. MPS for particles accelerators

High-accuracy measurement of standby to operating power

High-accuracy measurement of standby to operating power

DL2000ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Handy and Easy to Use Power Management Support

DQ600ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1 ppm. MPS for particles accelerators

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

AC/DC CLAMP METER AC CLAMP METER CM4000 series

INSULATION TESTER SERIES

DM1200ID. Specification highlights Symbol Unit Min Typ Max. Applications: Features. Power measurement and power analysis

DS200ID-CD100. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 2 ppm. MPS for particles accelerators

Single Device Solution for High Speed Testing and Frequency Sweeping IMPEDANCE ANALYZER IM3570

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

AC/DC Current Probe CT6844/CT6845/CT6846

, CLAMP ON POWER HiTESTER

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

PRECISION DC VOLTMETER DM7275, DM ½ Digit. Precision DC Voltmeter. 9 ppm DC Voltmeter for R&D to Production Lines

3331, 3332 POWER HiTESTER

A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need

LCR METER Series. A New Series of LCR Meters to Meet Your Applications. From Production Lines to Research and Development

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Standard models. Introducing a line of field-optimized instruments that can be chosen based on the application at hand

DS10000ULFS-10V/10kA

LCR METER Series. A New Series of LCR Meters to Meet Your Applications. From Production Lines to Research and Development

Offering a new approach to energyrelated


BATTERY HiTESTER BT3563, BT3562, 3561

CHEMICAL IMPEDANCE ANALYZER IM3590

High-precision Power Measurement of SiC Inverters

A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

IMPEDANCE ANALYZER IM3570

Ω and 0.1 fa Current Resolution DIGITAL SUPER MEGOHMMETER DSM-8104, DSM Fast, Highly Accurate Measurement. DSM-8104 (Single-Channel)

High speed Stability. DC, 4 Hz to 8 MHz. Measurement frequency LCR METER IM3536

INSULATION / VOLTAGE WITHSTAND TEST INSTRUMENT SERIES

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

High-precision, Wideband, Highly Stable Current Sensing Technology

CLAMP ON HiTESTER SERIES

High-Speed Resistance Meters Optimized for Automated Systems. RESISTANCE HiTESTER RM3542, RM Measure in as little as 0.

CATALOG including...

Accurately measure devices up to 1000 V/65 A AC/DC with direct input

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.

Eliminate the risk of short-circuits and electrical accidents PW3365 CLAMP ON POWER LOGGER

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

3239 (4-terminal Ω function) 3238 (Advanced model) 3237 (Economically priced) DIGITAL HiTESTER Field measuring instruments.

Fluke 3540 FC Three-Phase Power Monitor

supplies and frequency converters. BumbleBee is also very effective in fast transient measurements

Ideal for testing taping machines and sorters. C METER C HiTESTER 3504

The PW3336 (2-channel) and PW3337 (3-channel) can measure DC and a variety of power connections ranging from single-phase 2-wire to 3-phase 4-wire*.

DC Current Transducers CT-200 CT-300 CT-400 User s Manual All Rights Reserved CAEN ELS d.o.o. Rev. 1.0 November 2014

Fluke 3540 FC Three-Phase Power Monitor

Ideal for testing taping machines and sorters C METER C HiTESTER / / Electronic measuring instruments

CPCO Series (160mm) DC-AC Current Probe, Clamp On ±4000A, ±8000A, ±12000A,

Rugged, Professional and Ready for the Field. Capture high- to low-voltage signals in a single device. MEMORY HiCORDER MR8880

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and secondary circuit.

High Performance Current Transducer ITL 900-T = A

2300 REMOTE MEASUREMENT SYSTEM Data Logger

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

AC/DC Current Oscilloscope Probe Model SL261

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Rugged, Professional and Ready for the Field. Capture high- to low-voltage signals in a single device. MEMORY HiCORDER MR8880

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

Tap Changer Analyzer & Winding Ohmmeter RMO25TD

A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need

Wide Spectrum Power Meter for Comprehensive Device Assessment. DC/0.5Hz to 1MHz broad-band POWER HiTESTER measures up to 6 systems simultaneously.

INSTRUCTION MANUAL CLAMP ON PROBE

DIGITAL MULTIMETER DT4200 Series

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Featuring new judgment and ranking functionality LED OPTICAL METER TM6101. < Primary measurement application >

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

BumbleBee. High Voltage Differential Probe Ord.-No: Features:

Tap Changer Analyzer & Winding Ohmmeter RMO-TD Series

99 Washington Street Melrose, MA Phone Toll Free Visit us at

Ideal for testing taping machines and sorters

Winding Ohmmeter & Tap Changer Test Set RMO40TD with Demagnetizer

CPCO Series DC-AC Current Probe, Clamp On, 160mm, ±1000A ±2000A ±4000A ±8000A ±12000A, ±16000A

Technical Specifications for Portable 3-Ø Power Analyzer

Transcription:

AC/DC CURRENT SENSOR CT6904 Ultra-High Performance AC/DC Current Sensor World-Class Accuracy & Measurement Range (40 Conventional Models) 500 A (rms) Rated for measurement of large currents 4 MHz (±3 db) Wide measurement frequency range ±10 ppm Excellent linearity ±0.02% rdg. (±0.007% f.s.) Superior basic measurement accuracy 120 db (100 khz) High Common-Mode Rejection Ratio (CMRR)

2 Changing the World of Current Measurement Rating 500 A (rms) Measurement Frequency Range 4 MHz (±3 db) Linearity ±10 ppm Accuracy ±0.02% rdg. (±0.007% f.s.) CMRR 120 db (100 khz) High inverter efficiency and improved power saving technology performance for the power electronics, natural energy, and automotive industries. Responsive to the advanced demands of every industrial field.

3 Maximum Performance When Combined with POWER ANALYZER PW6001

4 Providing True Current Measurement 4 MHz Measurement Range, 40 Conventional Models Current sensor performance is maximized with the "Zero Flux (Fluxgate Detection)" measurement method. High frequency current is detected with windings (CT method), and direct to low frequency current is detected with fluxgates. Newly developed opposed split coil technology *1 is used in winding (CT) areas, achieving a wide measurement range from DC to 4 MHz. Magnetic Flux Due to Measurement Current Measurement Current Magnetic Core Opposed Split Coil Technology Magnetic Flux Due to Feedback Current Excitation f 2f Detection Fluxgate AMP Measuring Conductor Feedback Winding (N) Feedback Current Output (v out ) Shunt Resistor (r) Gain [db] 2 0 2-2 -4-6 -8 Frequency Characteristics (Typical) Gain (CT6904) Gain (Conventional Pass- Through Type Sensor) Phase (CT6904) Phase (CT6904, after compensation *2 ) -10-8 10 100 1 k 10 k 100 k 1 M 10 M Frequency [Hz] 4 0-2 -4-6 Phase [ ] *1 Opposed Split Coil: Coil in which divided windings are arranged opposite each other on a magnetic core to broaden the range of current detection *2 When performing phase compensation with HIOKI POWER ANALYZER PW6001 High Noise Resistance Common-Mode Rejection Ratio (CMRR) of 120 db or More (100 khz) The opposite split coil is completely shielded with a uniquely shaped solid shield, achieving both broad bandwidth and superior noise resistance. This allows accurate measurement without influence from surrounding voltage. 200 Common-Mode Voltage Rejection Ratio (Typical) CMRR [db] 180 160 140 120 Solid Shield Aluminum shield machined into a unique shape to eliminate influence on current measurements 100 CT6904 Conventional Pass-Through Type Current Sensor 80 10 100 1 k 10 k 100 k 1 M 10 M Frequency [Hz]

5 Highly Accurate and Highly Stable: ±10 ppm Linearity, ±0.02% rdg. ±0.007% f.s. Basic Accuracy By using a fluxgate element for DC to low frequency current detection, we have been able to achieve a level of measurement accuracy and temperature stability that is not possible with the Hall element method. Even at high frequencies the conductor position has little effect on measurement values, enabling measurements with high reproducibility. Linearity error [ppm] 60 40 20 0-20 -40 Linearity (Typical) Sample 1 Sample 2 Sample 3-60 -500-400 -300-200 -100 0 100 200 300 400 500 Input current [A] Gain Error (deviation from 23 C (73 F)) [% rdg.] 0.05 0.04 0.03 0.02 0.01 0.00-0.01-0.02-0.03-0.04-0.05-20 Temperature Characteristics (Typical) Sample 1 Sample 2 Sample 3 0 20 40 60 Temperature [ C] Linearity: Input current (DC) converted to +500 A 0 A -500 A 0 A +500 A at 100 A intervals to measure output voltage. Determined by the difference between the regression line (calculated from the above measurements) and measurement points. Effect of Conductor Position on Inner Core (A to F: Position) D C E F A B Deviation from center [ppm] 200 150 100 50 0-50 -100-150 -200 Effect of Conductor Position (Typical) Sample 1 100 khz Input Sample 2 100 khz Input Sample 3 100 khz Input Sample 1 50 Hz Input Sample 2 50 Hz Input Sample 3 50 Hz Input A B C D E F Position Shaped for Highly Accurate Measurement The longer the measured conductor, the greater the measurement error due to conductor inductance and parasitic capacitance. To reduce these errors, it is necessary to keep the conductor short. With the CT6904, you can select from a variety of installation methods, allowing you to minimize the length of the measured conductor. Supports a Variety of Installation Scenarios Wall Installation Fastening Bracket (Made to Order) The output cable can face in any direction.

6 Example Applications - Providing True Current Measurement with Unmatched Measurement Range and Noise Resistance - High-Precision and Efficiency Testing of SiC/GaN Inverters A wide range and minimal voltage current phase error are essential for the highly precise measurement of switching frequency power during PWM output. The CT6904, which features flat frequency characteristics over a wide range, provides accurate measurement of not only fundamental wave current but also switching frequency current. Since the CT6904 achieves both wide-range and highly accurate measurement performance, it can be used in combination with a power analyzer for more precise measurements of inverter input/output power and efficiency than ever before. Current Sensor Measurement Range and Inverter Secondary Active Power Spectrum (For 100 khz Switching) CT6904 Measurement Range Measurement Range of Conventional Models Battery Inverter Motor Active Power [W] Fundamental wave and its harmonics Switching frequency components and their harmonics HIOKI POWER ANALYZER PW6001 1 k 10 k 100 k 1 M Frequency [Hz] Perform highly accurate measurement of switching frequency components not possible with conventional models. Reactor/Transformer Loss Analysis Reactor and transformer loss measurement is becoming increasingly important for furthering the efficiency and miniaturization of power converters. Switching current, which has been obscured by noise until now, can be measured accurately thanks to the superior noise resistance of the CT6904. In addition, by using the phase correction function of the POWER ANALYZER PW6001, previously difficult reactor and transformer loss measurements for large currents, high frequencies and low power factors can now be performed easily and quickly. DC Power Supply Reactor Step-up DC Load DC Comparison of Measured Waveforms for CT6904 versus Conventional Sensor HIOKI POWER ANALYZER PW6001 CT6904 CMRR 120 db or greater (100 khz) Conventional model: No specifications defined for CMRR at 100kHz Example of Measured Waveforms for Switching Current at 100kHz (Measured with HIOKI PW6001)

Specifications 7 Input Output Measurement Specifications 1. Basic Specifications Rated primary current 500 A AC/DC Diameter of φ 32 mm (1.26 in) or less measurable conductors Within derating shown in figure below.. However, up to ±1000 A peak is allowable if within 20 ms (design value). Maximum input current When measuring current in the vicinity of derating, use a cooling time that is 10x or more greater than current input time. Output voltage 4 mv/a Maximum rated voltage 1000 V CAT III Expected transient overvoltage: 8000 V to ground Linearity Offset voltage 2. Accuracy Specifications Accuracy guarantee conditions Accuracy Effects of temperature Common-mode voltage rejection ratio (CMRR) Effect of conductor position ±10 ppm Typical (23 C (73 F)) ±10 ppm Typical (23 C (73 F), no input) Guaranteed accuracy period: 1 year Guaranteed accuracy period after adjustment made by Hioki: 1 year Temperature and humidity for guaranteed accuracy: 23 C ±5 C (73 F ±9 F), 80% RH or less Warm-up time: 30 min. or more Input waveform: sine wave, Connection: measuring instrument with an input resistance of 0.9 MΩ to 1.1 MΩ Terminal-to-ground voltage: 0 V, no external magnetic field, conductor center position Frequency Amplitude Phase DC ±0.025% rdg. ±0.007% f.s. - DC < f < 16 Hz ±0.2% rdg. ±0.02% f.s. ±0.1 16 Hz f < 45 Hz ±0.1% rdg. ±0.02% f.s. ±0.1 45 Hz f 65 Hz ±0.02% rdg. ±0.007% f.s. ±0.08 65 Hz < f 850 Hz ±0.05% rdg. ±0.007% f.s. ±0.12 850 Hz < f 1 khz ±0.1% rdg. ±0.01% f.s. ±0.4 1 khz < f 5 khz ±0.4% rdg. ±0.02% f.s. ±0.4 5 khz < f 10 khz ±0.4% rdg. ±0.02% f.s. ±(0.08 f) 10 khz < f 50 khz ±1% rdg. ±0.02% f.s. ±(0.08 f) 50 khz < f 100 khz ±1% rdg. ±0.05% f.s. ±(0.08 f) 100 khz < f 300 khz ±2% rdg. ±0.05% f.s. ±(0.08 f) 300 khz < f 1 MHz ±5% rdg. ±0.05% f.s. ±(0.08 f) Frequency range 4 MHz (±3 db Typical) - Unit for f in accuracy calculations: khz Amplitude accuracy and phase accuracy are defined below the rated value and within the continuous range of ambient temperature of 50 C (122 F) of the derating in the figure. However, the design value is DC < f < 10 Hz. For the specifications for an output cable length of 10 m (32.81 ft) (made to order), add an amplitude accuracy of ±(0.015 f)% rdg. to 50 khz < f 1 MHz. The frequency range is 2 MHz (±3 db Typical). Within the range of -10 C to 18 C (14 F to 64 F) or 28 C to 50 C (82 F to 122 F) Amplitude sensitivity: ±0.005% rdg./ C Offset voltage: ±0.005% f.s./ C Phase: ±0.01 / 140 db or greater (50 Hz/60 Hz), 120 db or greater (100 khz) (Effect on output voltage/common-mode voltage) ±0.01% rdg. or less (100 A input, 50 Hz/60 Hz), when using wire with 10 mm (0.39 in) outer diameter Function Specifications Connectable products 1. POWER ANALYZER PW6001 Combined Accuracy Frequency Current Power Phase DC ±0.045% rdg. ±0.037% f.s. ±0.045% rdg. ±0.057% f.s. (f.s. = PW6001 Range) (f.s. = PW6001 Range) 45 Hz f 65 Hz ±0.04% rdg. ±0.027% f.s. (f.s. = PW6001 Range) Bandwidths other than 45 Hz f 65 Hz and DC - For other measurement parameters, add the PW6001 accuracy and the sensor accuracy (and consider the sensor rating when calculating the f.s. error). - For 10 A Range and 20 A Range, apply ±0.12% f.s. (f.s. = PW6001 Range) 2. POWER ANALYZER PW3390 Combined Accuracy Add the power analyzer accuracy and the sensor accuracy (and consider the sensor rating when calculating f.s. error). 3. SENSOR UNIT CT9555 PW6001 accuracy + CT6904 accuracy (Consider sensor rating when calculating f.s. error.) Combined Accuracy Sensor accuracy x 1.5 (when the output coaxial cable is no longer than 1.6 m (5.25 ft)) - For the specifications for an output cable length of 10 m (32.81 ft) (made to order), a frequency range of 1 MHz (±3 db Typical). General Specifications Operating environment Operating temperature and humidity range Storage temperature and humidity range Dielectric withstand voltage Power supply Max. power consumption Interface Dimensions Output cable length Bracket hole diameter Mass Product warranty period 3 years Accessories ±0.04% rdg. ±0.037% f.s. (f.s. = PW6001 Range) PW6001 accuracy + CT6904 accuracy (Consider sensor rating when calculating f.s. error.) Indoors, Pollution Degree 2, altitude up to 2000 m (6562.20 ft) -10 C to 50 C (14 F to 122 F), and 80% RH or less (no condensation) -20 C to 60 C (-4 F to 140 F), and 80% RH or less (no condensation) 7.4 kv AC (sensed current of 1 ma), 50 Hz/60 Hz: 1 min Distance between feed-through window and cable output terminal Power supplied from PW6001, PW3390, and CT9555 7 VA (500 A/55 Hz measurement, with a power supply of ±12 V) Dedicated interface (ME15W) PW6001 accuracy + CT6904 accuracy Approx. 139 mm (5.47 in) W 120 mm (4.72 in) H 52 mm (2.05 in) D (excluding protrusions and cables) Approx. 3 m (9.84 ft) (including relay box) (Specifications for an output cable length of 10 m (32.81 ft) (made to order): Approx. 10 m (32.81 ft) (including relay box)) φ 5.2 mm (0.20 in) (M5 screws, Recommended tightening torque: 1.5 N m to 2.0 N m) Approx. 1.0 kg (35.3 oz) (Specifications for an output cable length of 10 m (32.81 ft) (made to order): Approx. 1.3 kg (45.9 oz) - Instruction manual - Carrying case - Color labels (for channel identification) 1000 600 A Derating Characteristics 550 A Maximum Current [A] 100 10-10 C (14 F) TA 50 C (122 F) (1 min) -10 C (14 F) TA 30 C (86 F) (Continuous) -10 C (14 F) TA 50 C (122 F) (Continuous) 1 DC 10 100 1 k 10 k 100 k 1 M 10 M Frequency [Hz] TA: Ambient temperature

Dimensional Drawing 22 5.2 4.6 52 110 120 29.8 29.8 30 Cable length: Approx. 3000 4x φ 5.2 (Bracket hole thickness: 7.5) (Units: mm) 139 Diameter of measurable conductors φ 32 or less 2 M5 press nuts (2 locations) (Units: mm) (Units: mm) 2 (Units: mm) Fastening Bracket (Made to Order) Dimensions CAT III 1000 V Model: AC/DC CURRENT SENSOR CT6904 Model No. (Order Code) (Specifications) CT6904 For PW6001 and others, ME15W terminal Accessories: Instruction manual x 1, Carrying case x 1, Color labels (for channel identification) x 1 HIOKI ME15W (12-pin Terminal) * Made-To-Order Options for the CT6904 Model No. (Order Code) (Specifications) -- 10 m (32.81 ft) Output Cable Specifications -- Fastening Bracket Note: Company names and Product names appearing in this catalog are trademarks or registered trademarks of various companies. HIOKI (Shanghai) SALES & TRADING CO., LTD. TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360 info@hioki.com.cn / www.hioki.cn DISTRIBUTED BY HEADQUARTERS 81 Koizumi Ueda, Nagano 386-1192 Japan www.hioki.com HIOKI SINGAPORE PTE.LTD. TEL +65-6634-7677 FAX +65-6634-7477 info-sg@hioki.com.sg / www.hioki.com.sg HIOKI KOREA CO., LTD. TEL +82-2-2183-8847 FAX +82-2-2183-3360 info-kr@hioki.co.jp / www.hiokikorea.com HIOKI USA CORPORATION TEL +1-609-409-9109 FAX +1-609-409-9108 hioki@hiokiusa.com / www.hiokiusa.com HIOKI EUROPE GmbH TEL +49-6173-3234063 FAX +49-6173-3234064 hioki@hioki.eu / www.hioki.com All information correct as of Feb. 21, 2018. All specifications are subject to change without notice. CT6904E1-82E Printed in Japan