phase PCB mount solid state relays Main features AC Solid State Relay for PCB mounting Zero switching or instanton Rated operational current: 3, 5 or 5.5 AACrms Rated operational voltage: Up to 480 VACrms Surface mount technology Flexible encapsulation for extended life Control voltage: 3 to 3 VDC / 6 to 3 VAC Optoisolation: > 4000 VACrms Blocking voltage: Up to 000 Vp Nonrepetitive surge current: Up to 50 Ap Description The RP is an SSR series for socket or PCBmounting, providing an ideal interface between logic controls and AC loads. The RP is designed for resistive and inductive loads up to 480VACrms. Internally this new series enjoys an improved technical design with the introduction of stressfree flexible encapsulation and automated assembly of components. The Solid State technology used can withstand peak voltages of 000V, making the RP series suitable to drive AC loads such as valve solenoids and small induction motors. Applications These relays can be used to switch heaters, motors, lights, valves or solenoids. Main functions Zero cross or Instant on AC switching Ratings up to 480 VACrms, 5.5 AACrms 33 VDC or 63 VAC control voltage
References Order code RP Enter the code entering the corresponding option instead of Code Option Description Notes R Solid State Relay (PCB) P Number of poles A Switching mode: zero switching B Switching mode: instanton switching 3 Rated operational voltage: 30 VACrms 40 Rated operational voltage: 400 VACrms 48 Rated operational voltage: 480 VACrms 4 to 3 VDC for RPA48.. D Control voltage: 3 to 3 VDC 4 to 3 VDC for RPB40.. and RPB48.. A Control voltage: 6 to 3 VAC Only available for 30V, 5.5 A 3 Rated operational current: 3 AACrms 5 Rated operational current: 5 AACrms 6 Rated operational current: 5.5 AACrms Mx M = Mounting on DIN EN adaptor RPM Max. 50V M = Mounting on DIN EN adaptor RPM Max. 600V Selection guide Rated operational voltage Blocking voltage 30 VACrms 650 Vp 400 VACrms 850 Vp Control voltage 3 to 3 VDC 6 to 3 VAC 3 to 3 VDC 4 to 3 VDC 480 VACrms 000 Vp 4 to 3 VDC Rated operational current 3 AACrms 5 AACrms 5.5 AACrms RPA3D3 RPA3D5 RPA3D6 RPB3D3 RPB3D5 RPB3D6 RPA3A6 RPA40D3 RPA40D5 RPA40D6 RPB40D3 RPB40D5 RPB40D6 RPA48D3 RPB48D3 RPA48D5 RPB48D5 RPA48D6 RPB48D6 Selection Guide (mounted on DIN EN adaptor) Rated operational voltage Blocking voltage 30 VACrms 650 Vp Control voltage 5 to 34 VDC 6 to 3 VAC Rated operational current 3 AACrms 5 AACrms 5.5 AACrms RPA3D3M RPA3D5M RPA3D6M RPB3D3M RPB3D5M RPB3D6M RPA3A6M* 480 VACrms 000 Vp 6 to 34 VDC RPA48D5M * Version RPA3A6M does not include an LED on the DIN adaptor.
CARLO GAVAZZI compatible components Purpose Component name/code Notes DIN adaptors RPM* RPMV* RPMP RPMPD* RPM DIN adaptor 50V with LED DIN adaptor 50V with LED + varistor DIN adaptor 50V with pins for removal of RP DIN adaptor 50V with pins for removal of RP + LED DIN adaptor 600V with LED *not suitable for use with RPA3A6 Further reading Information Where to find it 3
Features General Material PBT, RAL7035 Potting compound Flameretardant flexible silicone rubber Weight Approx. 0 g Isolation: input to output 4 kvacrms Insulation resistance 0 0 Insulation capacitance 8 pf Dimensions 4
Performance Mains supply Operational voltage range RPA RPB Operational frequency range RP.3 RP.40 RP.48 65 VACrms 65 VACrms 0 440 VACrms 440 VACrms 45 65 Hz Blocking voltage 650 Vp 850 Vp 000 Vp Zero voltage turnon < 0 V 0 530 VACrms 530 VACrms Outputs RP...3 RP...5 RP...6 Rated operational current AC 5 @ T a = 5 C AC 53a @ T a = 5 C 3 A A 5 A 3 A 5.5 A 5 A Min. operational load current 0 ma Power factor > 0.5 Rep. overload current t= s 0 AACrms AACrms 6 AACrms Nonrep. surge current t=0 ms 65 Ap 80 Ap 50 Ap Offstate leakage current < ma I t for fusing t=0 ms 0 A s 50 A s 340 A s Critical dv/dt off state min. 50 V/μs 500 V/μs Onstate voltage drop @ rated current <. Vrms Inputs Control voltage RP.3.. RPA40.. RPB40.. RP.48.. Pickup voltage RP.3.. RPA40.. RPB40.. RP.48.. RP..D RP..D..Mx RPA3A6 33 VDC 43 VDC.8 VDC 3.8 VDC 534 VDC 634 VDC 4.8 VDC 5.8 VDC 6 3 VAC 0 VAC Dropout voltage. VDC 5 VAC Max. input curent RPA... RPB... 0 madc 5 madc Max. reverse voltage 3 VDC 34 VDC Response time pickup RPA... RPB... Response time dropout RPA... RPB... < 0 ms < 60 μs ( VDC/ 50 Hz) < 30 μs (5 VDC/ 50 Hz) < 0 ms < 0 ms 3 maac < 0 ms < 0 ms 5
Derating curve Load current (AACrms) 6 5 4 3 D6 D5 D3 0 0 30 40 50 60 70 Surrounding temp. ( C) Derating curve is used for finding max. load current at an elevated ambient temperature. The 3 lines in the graph represent the 3 nominal current ratings of the RP series (RP...D3/D5/D6). When used at full load current, the relays must be placed vertically. If more than one relay is mounted, please allow a minimum distance of 0 mm in between for sufficient air cooling. Increased Current Options I peak I nom T amb = 5 o C t I peak (Amps) 6 8 0 D5 : t (minutes) 5 5 3 D6 : t (minutes 5 5 3 Note: even though the D3 can withstand a slight increase in current for a limited time, it is not recommended for this purpose. Thermal data Operating temperature Storage temperature 0 to +70 C (4 to +58 F) 40 to +00 C (40 to + F) 6
Compatibility and conformity Standards compliance LVD: EN 6094743 EMCD: EN 60006, EN 600064 UL508 C. No. 43 VDE 0700, VDE 0805 (excluding RPA3A6) Approvals Electromagnetic compatibility (EMC) immunity EN/IEC 60004 Electrostatic discharge (ESD) 8 kv air discharge, 4 kv contact (PC) EN/IEC 600043 0 V/m, from 80 MHz to GHz (PC) Radiated radio frequency 0 V/m, from.4 to GHz (PC) 0 V/m, from to.7 GHz (PC) EN/IEC 600044 Electrical fast transient (burst) Output: kv, 5 khz (PC) Input: kv, 5 khz (PC) EN/IEC 600046 Conducted radio frequency 0V/m, from 0.5 to 80 MHz (PC) EN/IEC 600045 Output, line to line: kv (PC) Electrical surge Output, line to earth: kv (PC) Input, line to line: 500 V (PC) Input, line to earth: 500 V (PC) Voltage dips Voltage Interruptions EN/IEC 60004 0% for 0.5, cycle (PC) 40% for 0 cycles (PC) 70% for 5 cycles (PC) EN/IEC 60004 0% for 5000ms (PC) Electromagnetic compatibility (EMC) emissions Radio interference field emission (radiated) Class A: from 30 to 000 EN/IEC 550 MHz Radio interference voltage emissions (conducted) From 0.5 to 30 MHz EN/IEC 550 Class A (industrial) with filter capacitor across the Mains supply EN/IEC 6094743 Class A (no filtering needed) Note: Performance Criteria (PC): no degradation of performance or loss of function is allowed when the product is operated as intended. Performance Criteria (PC): during the test, degradation of performance or partial loss of function is allowed. However when the test is complete the product should return operating as intended by itself. Performance Criteria 3 (PC3): temporary loss of function is allowed, provided the function can be restored by manual operation of the controls. Control input lines must be installed together to maintain products' susceptability to Radio Frequency interference. A suppression device, such as a varistor, needs to be connected across the output terminals L, T for immunity against higher voltage levels. A suppression device, such as a transil, needs to be connected across the control terminals A, A for immunity against higher voltage levels. 7
RP... Functional diagram (+) 3 Control input () 4 REGULATION ZC IO * ZC Zero Crossing IO Instant On RP..Mx Functional diagram RP..Mx RP... (+) 3 Control input () 4 (+) 3 Control input () 4 3 (+) 4 () REGULATION ZC IO ZC Zero Crossing IO Instant On * * The varistor is not included in the solid state relay. Connecting a varistor across terminals helps protect the solid state relay against damages by overvoltage Connection specifications Terminals Terminals soldering temperature Copper alloy, tinplated max. 300 C for 5 seconds COPYRIGHT 06 Content subject to change. Download the PDF: www.productselection.net 8