MD 103 ESD TargET SET USEr ManUal B

Similar documents
CALIBRATION KIT FOR EFT / BURST CAPACITIVE COUPLING CLAMP INA 3425 USER MANUAL A

MD 200A High voltage differential probe

INA 703 MAgNetIc field coil

CBA 400M MHZ to 400 MHZ

Nsg inductive switch transient test circuit

Advanced Test Equipment Rentals ATEC (2832) INA A

CDN 117 / 117-M CDN 118-T4 / 118-EXT-1 SIGNAL & DATA LINE COUPLING NETWORKS USER MANUAL M

COUPLING NETWORK (CN) FOR IEC / EN , DC TO 150 khz

PA Automotive battery simulators

Specification. CTR 2 ESD calibration target

CTR2 / CTR2-AD CALIBRATION TARGET AND VERIFICATION ADAPTER FOR ESD

Test Systems. VSQ 3000/3002 Reference Radiation Source up to 3GHz

Coupling / decoupling network (CDN) for screened or coaxial cables

GTEM cells. Emissions and immunity testing in a single, shielded environment

COUPLING / DECOUPLING NETWORK (CDN) CDN AF TYPE, CDN CAN

CTR2 / CTR2-AD CALIBRATION TARGET AND VERIFICATION ADAPTER FOR ESD

THE MODULAR SOLUTION FOR 6 KV APPLICATIONS

MONITORING DEVICE 4 khz to 400 MHz

P331-2 set ESD generator (IEC )

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AMETEK CO., LTD. NAGOYA OFFICE. (Main Laboratory) Onna, Atsugi-shi, Kanagawa-ken, Japan

COUPLING DECOUPLING NETWORKS FOR IEC / EN

RADIATED IMMUNITY TEST SYSTEM 6 GHz

PHV RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

NSG Hard keys for important functions. 5.7 color display, easy to use firmware. 3 power meter

Keysight Technologies P9400A/C Solid State PIN Diode Transfer Switches

R&S ENV216 Two-Line V-Network For disturbance voltage measurements on single-phase EUTs

400 MHz Passive High-Voltage Probe R&S RT-ZH

Kentech Instruments Ltd. CPS3/S pulser Serial No. J03*****

V1.3. TBLC08 50mH AC-LISN TBLC08

Supplied in carry case with additional accessories The PHV 1000-RO is a 400 MHz, standard sized, 100:1 passive probe designed for instruments

Advanced Test Equipment Rentals ATEC (2832)

TETRIS 1000 High Impedance Active Probe. Instruction Manual

1000BASE-T1 EMC Test Specification for Common Mode Chokes

Advanced Test Equipment Rentals ATEC (2832) EMC Calibration ServiCES. Reliable fast worldwide

SAW Components. Low-Loss Filter for Mobile Communication. RF360 Europe GmbH. A Qualcomm TDK Joint Venture. Data Sheet B4926.

Physical Test Setup for Impulse Noise Testing

Agilent E2695A SMA Probe Head for InfiniiMax 1130 Series Active Oscilloscope Probes. User s Guide

Two Line V-Network GLN-5040A USER MANUAL GW INSTEK PART NO. 99 Washington Street Melrose, MA Phone Toll Free

Robust Precision Interface up to 90 GHz. RPC-1.35 Connectors TEST & MEASUREMENT

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

Schlöder GmbH - EMC Test and Measurement Systems Model #

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

Kentech Instruments Ltd. CPS3/S/P pulser Serial No. xxxx

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Current Probes. User Manual

50 μh Line Impedance Stabilisation Network (AC LISN)

PHV 1000-RO. High impedance passive probe. Features: CeramCore TM hybrid probe. Modular construction. Coaxial design

CURRENT MEARUREMENT SHUNT CS-10/500 USER MANUAL

SAW Components. Low-Loss Filter. RF360 Europe GmbH. A Qualcomm TDK Joint Venture. Data Sheet B5013. Ordering code: Date: Nov 30, 2004 Version:

SAW components. SAW RF filter Short range devices. RF360 Europe GmbH A Qualcomm TDK Joint Venture. Date: September 15, 2017 Version: 2.

ACCREDITED LABORATORY. LIBERTY LABS, INC. Kimballton, IA for technical competence in the field of Calibration

For the National Voluntary Laboratory Accreditation Program


User s Guide. RP7000 Series Active Probe. Dec RIGOL Technologies, Inc.

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

Methods for Testing Impulse Noise Tolerance

Coupling- / Decoupling Network. 150 khz 300 MHz. 150 khz 230 MHz. 10 khz 230 MHz. IEC and CISPR 15 / CISPR 22 IEC

TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY

SAW components. SAW RF filter Digital radio. RF360 Europe GmbH A Qualcomm TDK Joint Venture. Date: April 26, 2017 Version: 2.1

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ANSI/NCSL Z & ANSI/NCSL Z540.3

CAL U100B CAL U100B CDN M016 CAL U100B CDN M016 CAL U100B. Used as M2 CDN. Used as M3 CDN

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

FlexRay Communications System. Physical Layer Common mode Choke EMC Evaluation Specification. Version 2.1

HX-3. Headphone Distribution Amplifier User Guide and Technical Information

COFFEE LABORATORY WHITE STONE VA TEL

USER MANUAL HIGH INTERCEPT LOW NOISE AMPLIFIER (HILNA TM ) MODEL NUMBER: HILNA LS

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

TETRIS User's Guide. High Impedance Active Probe DO177-1

Improving CDM Measurements With Frequency Domain Specifications

Test & Measurement. Technical Information. R&S ZV-WR10 / -WR12 / -WR15 Calibration Kits

Voltage Transient Emission Test

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

CXE180 UNIVERSAL AMPLIFIER

Instruction Manual Inductive Gauging Sensor

IEC Electrical fast transient / Burst immunity test

SAW components. SAW RF Uplink 2in1 input diplex filter Base stations LTE band 5 and 13. RF360 Europe GmbH A Qualcomm TDK Joint Venture

Probing Techniques for Signal Performance Measurements in High Data Rate Testing

TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY

System description 4. SERVICES ONSITE INSTALLATION AND TRAINING SYSTEM ACCEPTANCE MAINTENANCE... 7

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

The 144MHz Anglian 3 transverter

MG5223F S-Band Magnetron

FISCHER CUSTOM COMMUNICATIONS, INC.

7. Operating instructions: EFL 300

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

PRODUCT DATA. Falcon Range 1/4-inch Microphone Preamplifier Type 2670

CXE180 UNIVERSAL AMPLIFIER

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Instruction Manual CT-6 High Frequency AC Current Probe

Agilent 8761A/B Microwave Switches

Agilent 8761A/B Microwave Switches

SAW components. SAW duplexer Automotive telematics WCDMA band 1. RF360 Europe GmbH A Qualcomm TDK Joint Venture. Date: June 05, 2017 Version: 2.

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

USER MANUAL HIGH INTERCEPT LOW NOISE AMPLIFIER (HILNA TM ) MODEL: HILNA CX

E2V Technologies MG5222 X-Band Magnetron

5MHz FUNCTION GENERATOR

Keysight Technologies Using a Network and Impedance Analyzer to Evaluate MHz RFID Tags and Readers/Writers

Transcription:

1 MD 103 ESD Target Set User Manual 601-266B

MD 103 ESD Target Set User Manual MD 103 ESD target set

contents 1 Safety terms and symbols 5 2 The ESD target set 6 3 Handling of the target set 7 4 Requirements by a new draft standard 9 5 Using the target 10 6 Relation between voltage and real current flowing 12 7 Preparing the target for calibration with INA 103 adapter 13 8 Calibrating the target using INA 103 option 16 9 Determining the low frequency transfer impedance 19 10 Technical specifications MD 103 20 11 Ordering information 21 12 Addresses 22

1 Safety terms and symbols 5 Please take note of the following explanations of the symbols used in order to achieve the optimum benefit from this manual and to ensure safety during operation of the equipment. The following symbol draws your attention to a circumstance where nonobservation of the warning could lead to inconvenience or impairment in the performance. Example: Caution statements identify conditions or practices that could result in damage to this product or other property.

6 2 The ESD target set An ESD target is a shunt for measuring the ESD discharge current flowing in a measurement circuit. The target is intended to emulate a discharge into a perfect ground plane. To minimize the error caused by any difference between a perfect conducting plane and the input impedance of the target, a 2.1 Ω limit has been set for the input impedance. The impedance of the MD 103 target is 1.03 Ω. An even smaller impedance value would generate a very small output signal which would be subject to errors due to coupling into cables and oscilloscope. A very important parameter of the target is the DC transfer impedance Z SYS, this is the ratio between the voltage measured on the scope and the real current flowing through the target. For the exact value, please refer to the calibration certificate. MD 103 ESD target set

3 Handling of the target set 7 The target consists of the complete set with cable, attenuator and discharge part (target) like the pictures below. The MD 103 is a high precision device, please handle with care. Leave the ESD target with the attenuator and the cable together and do not disassemble the set in parts, since the whole coupling path has been calibrated in one piece.

8 MD 103 parts identification: Carry case User manual Calibration certificate ESD target Attenuator 20 db Coax cable Sucoflex The carry case has extra space for the calibration adapter INA 103, the special screw tool and an adapter to connect to an analyzer or to a scope. MD 103 ESD target set

4 Requirements by a new draft standard 9 In order to improve the reproducibility between calibration laboratories, the frequency characteristic of the target has now been defined in a new draft standard submitted by ANSI and IEC. The new draft of the standard sets limits for the insertion loss of the whole measurement chain including the target itself, cables and any attenuator present. The variation in the insertion loss of the chain may not exceed: +/- 0.3 db up to 1 GHz +/- 1 db between 1 GHz and 4 GHz The MD 103 shows an almost flat frequency response up to 4 GHz. The next figure shows the insertion loss of the MD 103 (solid line) and the permitted tolerances (dotted lines). 47 Reflection coefficent [db] 48 49 50 0 1 10 9 2 10 9 3 10 9 4 10 9 Frequenzy [Hz] 4 GHz

10 5 Using the target The MD 103 target comes fully assembled ready to be screwed into the reference plane. The plane should be at least 1.2 x 1.2 m in size and forms part of a HF-tight enclosure for cables, attenuators and the oscilloscope. Ground plane 1.2 m ESD simulator Shielded enclosure for the oscilloscope and connecting cables Current target 1.2 m Ground strap connection point Ground strap (pulled away at its midpoint) Power cord RF filter for AC power Typical arrangement for calibration of ESD simulator performance. MD 103 ESD target set

This is the drilling template for the reference plane. 11 45 Canter hole 51 + 0.5 mm Thread M3 60 mm Schematically, the measurement chain looks as follows. Frequency response of cables, attenuator and connectors >>2 GHz Oscilloscope min. 2 GHz analogue bandwidth

12 6 Relation between voltage and real current flowing To get the peak current, a suitable scope will be needed as well as the exact transfer impedance ratio value Z SYS, which is found in the calibration certificate. If the target is mounted, and the measuring setup conforms to the standard recommendations, then following calculation has to be made to get the current. Measured peak voltage [V] = Pulse peak current [A] Low frequency transfer impedance ratio [Ω] Numeric example: Set the ESD simulator to 8 kv and discharge directly to the target so the peak voltage on the scope in the 50 Ω system is 2.89 V. The transfer impedance for the MD 103 is Z SYS = 0.098 Ω or 10.3 1 Ω [Siemens]. 2.89 V = 29.49 A 0.098 So the calculated peak current flow is 29.49 A by 8 kv ESD voltage. To fulfill the IEC/EN 61000-4-2 recommendation the 30 ns and the 60 ns point needs to be measured and calculated, too. MD 103 ESD target set

7 Preparing the target for calibration with INA 103 adapter 13 The optional INA 103 is needed if the target has to be calibrated. The INA 103 calibration adapter can be placed in the MD 103 carry case. For calibration, unscrew the center contact bolt with the special screw tool and remove it carefully.

14 Unscrew the INA 103 connector socket from the calibration ring. Disassemble the INA 103 adapter to the following parts. Connector socket Calibration ring The center pin of the connector socket can be disassembled to into connector pin, isolator and screw bolt. Connector pin Isolator Screw bolt Screw now the calibration ring onto the target. MD 103 ESD target set

Screw from the center pin the screw bolt into the target, add the isolator and screw the connector pin into the screw bolt. 15 Screw the connector socket onto the calibration ring. The assembled target with the calibration adapter is now ready to be used for calibration.

16 8 Calibrating the target using INA 103 option According to the new draft standard, the insertion loss of the target should be measured with a network analyzer. The network analyzer has two coaxial connection ports. For insertion loss measurements on the target an adapter is necessary, which provides a matched low reflection from the front side of the target to the coaxial connector of the network analyzer. Network analyzer Signal OUT Signal IN Attenuator C Attenuator B Calibration adaper INA 103 MD 103 ESD target Cable A Attenuator A Calibrate the network analyzer at this point The ESD current target, attenuator A and cable A are the target-attenuatorcable chain which is calibrated using this setup. Attenuator B and C may not be needed. For a proper connection to an analyzer or scope an adaptor may be needed and can be placed into the spare place of the MD 103 carry case. MD 103 ESD target set

In order to minimize the influence of the adapter on the measurements, frequency parameters of the adapter are specified in the draft. These parameters are verified for two adapters connected face to face. They must be as follows: 17 Reflection coefficient: < -30 db up to 1 GHz < -20 db between 1 GHz and 4 GHz 15 20 25 Reflection coefficent [db] 30 35 40 45 50 55 60 0 1 10 9 2 10 9 3 10 9 4 10 9 Frequenzy [Hz] 4 GHz Reflection coefficient of two adapters for the MD 103 placed face to face (solid line) and the permitted tolerance (dotted line).

18 Insertion loss must be better than -0.3 db up to 4 GHz. 0 Reflection coefficent [db] -0.2 0.4 0 1 10 9 2 10 9 3 10 9 4 10 9 Frequenzy [Hz] Insertion loss of two adapters for the MD 103 placed face to face (solid line) and the permitted tolerance (dotted line). Moreover the characteristic impedance of the adapter must be within the limit of 50 Ω +/- 2% (i.e. it must be between 49 and 51 Ω). The adapter is an assembly of coaxial cylinders with a diameter for the outer cylinder D = 16 mm +/- 0.02 mm and a diameter of the inner cylinder d = 7 mm +/- 0.02 mm. The formula for calculating the characteristic impedance is as follows: Z w = 60 ln D d The calculated characteristic impedance of the adapter is therefore 49.6 Ω. Taking into account the tolerances, this impedance is no greater than 49.35 Ω and no less than 49.84 Ω. Another significant element of the adapter is the professional connector type N-7/16 (Huber Suhner). The producer of the connector guarantees 50 Ω +/-2% characteristic impedance up to 7.5 GHz. The requirement concerning the characteristic impedance of the adapter for the MD 103 is hence fulfilled. MD 103 ESD target set

9 Determining the low frequency transfer impedance 19 The low frequency transfer impedance of a target-attenuator-cable chain is defined as the ratio between the current injected at the front face of the target and the voltage across a precision 50 Ω load at the output end of the cable. The circuit diagram for measuring the low frequency transfer impedance looks as follows: SYS A Target Attenuator Cable R 50 Ω V V 50 The low frequency transfer impedance can be determined by: Injecting a DC or LF current ISYS of approx. 1 A into the front face of the target. Measuring the voltage V 50 across the precision 50 Ω. Calculating the transfer impedance as follows: Z w = D 50 I SYS

20 10 Technical specifications MD 103 Insertion loss (S21 parameter): Average low frequency transfer impedance: Inner target diameter: Impedance: Calibration ESD pulse amplitude: Max. ESD pulse amplitude: Calibration adapter reflection coefficient: Target parts: Cable connectors: < -48.3 db DC to 4 GHz ZSYS = 0.098 Ω 7 mm 1.03 Ω (SMD design) 1/2/4/8/15 kv 30 kv < -40 db up to 1 GHz < -25 db between 1 GHz and 4 GHz Gold plated Type N MD 103 ESD target set

11 Ordering information 21 MD 103 ESD calibration target set Including: Carry case User manual Calibration certificate ESD target Attenuator 20 db Coax cable Sucoflex Options: INA 103 Calibration adaptor with special screw tool

Headquarters Teseq AG 4542 Luterbach, Switzerland T + 41 32 681 40 40 F + 41 32 681 40 48 sales @ teseq.com www.teseq.com China Teseq Company Limited T + 86 10 8460 8080 F + 86 10 8460 8078 chinasales @ teseq.com Germany Teseq GmbH T + 49 30 5659 8835 F + 49 30 5659 8834 desales @ teseq.com Singapore Teseq Pte Ltd. T + 65 6846 2488 F + 65 6841 4282 singaporesales @ teseq.com Taiwan Teseq Ltd. T + 886 2 2917 8080 F + 886 2 2917 2626 taiwansales @ teseq.com Manufacturer Teseq AG 4542 Luterbach, Switzerland T + 41 32 681 40 40 F + 41 32 681 40 48 sales @ teseq.com France Teseq Sarl T + 33 1 39 47 42 21 F + 33 1 39 47 40 92 francesales @ teseq.com Japan Teseq K.K. T + 81 3 5725 9460 F + 81 3 5725 9461 japansales @t eseq.com Switzerland Teseq AG T + 41 32 681 40 50 F + 41 32 681 40 48 sales @ teseq.com UK Teseq Ltd. T + 44 845 074 0660 F + 44 845 074 0656 uksales @ teseq.com USA Teseq Inc. T + 1 732 417 0501 F + 1 732 417 0511 Toll free +1 888 417 0501 usasales @ teseq.com To find your local partner within Teseq s global network, please go to www.teseq.com December 2010 Teseq Specifications subject to change without notice. Teseq is an ISOregistered company. Its products are designed and manufactured under the strict quality and environmental requirements of the ISO 9001. This document has been carefully checked. However, Teseq does not assume any liability for errors or inaccuracies.