SPS1M-EVK. SPS1M-EVK Battery Free Wireless Sensor Handheld Evaluation System EVAL BOARD USER S MANUAL

Similar documents
AND8285/D. NCP1521B Adjustable Output Voltage Step Down Converter Simulation Procedure SIMULATION NOTE

Is Now Part of To learn more about ON Semiconductor, please visit our website at

1. DEFINE THE SPECIFICATION 2. SELECT A TOPOLOGY

FJP13007 High Voltage Fast-Switching NPN Power Transistor

EVALUATION BOARD FOR STK N, 120N, 140N. Phenol 1-layer Board) Figure 2. STK NGEVB Figure 3. STK NGEVB Figure 4.

BAV103 High Voltage, General Purpose Diode

AND9097/D. Ayre SA3291 Getting Started Guide APPLICATION NOTE

AND8450/D. NCV7680 LED Driver Linear Regulator Performance APPLICATION NOTE

Is Now Part of To learn more about ON Semiconductor, please visit our website at

TIP120 / TIP121 / TIP122 NPN Epitaxial Darlington Transistor

NSVF4017SG4. RF Transistor for Low Noise Amplifier. 12 V, 100 ma, f T = 10 GHz typ.

General Description. Applications. Power management Load switch Q2 3 5 Q1

Is Now Part of. To learn more about ON Semiconductor, please visit our website at

KSC2383 NPN Epitaxial Silicon Transistor

NSVF5501SK RF Transistor for Low Noise Amplifier

FPF1005-FPF1006 IntelliMAX TM Advanced Load Management Products

AND9100/D. Paralleling of IGBTs APPLICATION NOTE. Isothermal point

FGH40N60SFDTU-F V, 40 A Field Stop IGBT

PCS2I2309NZ. 3.3 V 1:9 Clock Buffer

FGH12040WD 1200 V, 40 A Field Stop Trench IGBT

NSVS50030SB3 NSVS50031SB3. Bipolar Transistor ( )50 V, ( )3 A, Low V CE (sat), (PNP)NPN Single

Is Now Part of To learn more about ON Semiconductor, please visit our website at

Parameter Symbol Conditions Ratings Unit

Extended V GSS range ( 25V) for battery applications

BAV ma 70 V High Conductance Ultra-Fast Switching Diode

Single stage LNA for GPS Using the MCH4009 Application Note

KSH122 / KSH122I NPN Silicon Darlington Transistor

74VHC14 Hex Schmitt Inverter

SEAMS DUE TO MULTIPLE OUTPUT CCDS

Low Capacitance Transient Voltage Suppressors / ESD Protectors CM QG/D. Features

CAX803, CAX809, CAX Pin Microprocessor Power Supply Supervisors

NSR0340V2T1/D. Schottky Barrier Diode 40 VOLT SCHOTTKY BARRIER DIODE

Is Now Part of To learn more about ON Semiconductor, please visit our website at

FFSH5065A. Silicon Carbide Schottky Diode 650 V, 50 A

QED223 Plastic Infrared Light Emitting Diode

NSVJ3910SB3 N-Channel JFET 25V, 20 to 40mA, 40mS

Is Now Part of To learn more about ON Semiconductor, please visit our website at

434MHz LNA for RKE Using the 2SC5245A Application Note

Is Now Part of To learn more about ON Semiconductor, please visit our website at

Figure 1. NCP5104 Evaluation Board

Is Now Part of To learn more about ON Semiconductor, please visit our website at

Dual N-Channel, Digital FET

PCS2P2309/D. 3.3V 1:9 Clock Buffer. Functional Description. Features. Block Diagram

Is Now Part of To learn more about ON Semiconductor, please visit our website at

FDN327N FDN327N. N-Channel 1.8 Vgs Specified PowerTrench MOSFET. Absolute Maximum Ratings

RURG8060-F085 80A, 600V Ultrafast Rectifier

NVC6S5A444NLZ. Power MOSFET. 60 V, 78 m, 4.5 A, N Channel

RURP1560-F085 15A, 600V Ultrafast Rectifier

AND8388/D. Input Dynamic Range Extension of the BelaSigna 300 Series

SS13FL, SS14FL. Surface Mount Schottky Barrier Rectifier

S1AFL - S1MFL. Surface General-Purpose Rectifier

Features D G. T A =25 o C unless otherwise noted. Symbol Parameter Ratings Units. (Note 1a) 3.8. (Note 1b) 1.6

Is Now Part of To learn more about ON Semiconductor, please visit our website at

N-Channel Logic Level PowerTrench MOSFET

MBRA320T3G Surface Mount Schottky Power Rectifier

NTNUS3171PZ. Small Signal MOSFET. 20 V, 200 ma, Single P Channel, 1.0 x 0.6 mm SOT 1123 Package

Overview The LA5744MP is a separately-excited step-down switching regulator (variable type).

ASM1232LP/LPS 5V μp Power Supply Monitor and Reset Circuit

FDD V P-Channel POWERTRENCH MOSFET

RHRP A, 1200 V, Hyperfast Diode. Features. Applications. Ordering Information. Packaging. Symbol. Data Sheet November 2013

Is Now Part of To learn more about ON Semiconductor, please visit our website at

Is Now Part of To learn more about ON Semiconductor, please visit our website at

Features. TA=25 o C unless otherwise noted

Packing Method. Symbol Parameter Test Conditions Min. Typ. Max. Unit V CE(sat) Saturation Voltage V C = 25 A, V GE = 15 V,

Features -4 A, -30 V. R DS(ON) G 3. = 25 C unless otherwise note. Symbol Parameter Ratings Units. Drain-Source Voltage -30 V

PUBLICATION ORDERING INFORMATION. Semiconductor Components Industries, LLC

FDN335N N-Channel 2.5V Specified PowerTrench TM MOSFET

Is Now Part of To learn more about ON Semiconductor, please visit our website at

MM74HC04 Hex Inverter

Is Now Part of. To learn more about ON Semiconductor, please visit our website at

P-Channel PowerTrench MOSFET

1.05 W epoxy board Operating temperature Topr 20 to +100 C Storage temperature Tstg 55 to +150 C

NUF8401MNT4G. 8-Channel EMI Filter with Integrated ESD Protection

NBSG86ABAEVB. NBSG86A Evaluation Board User's Manual EVAL BOARD USER S MANUAL.

Is Now Part of To learn more about ON Semiconductor, please visit our website at

NCP786L. Wide Input Voltage Range 5 ma Ultra-Low Iq, High PSRR Linear Regulator with Adjustable Output Voltage

Features 2.5 A, 30 V. R DS(ON) = 25 C unless otherwise note. Symbol Parameter Ratings Units. Drain-Source Voltage 30 V

RURD660S9A-F085 Ultrafast Power Rectifier, 6A 600V

PZTA92T1. High Voltage Transistor. PNP Silicon SOT 223 PACKAGE PNP SILICON HIGH VOLTAGE TRANSISTOR SURFACE MOUNT

MBR20200CT. Switch mode Power Rectifier. Dual Schottky Rectifier SCHOTTKY BARRIER RECTIFIER 20 AMPERES, 200 VOLTS

Package Marking and Ordering Information Device Marking Device Package Reel Size Tape Width Quantity V36P ISL9V36P3-F8 TO-22AB Tube N/A Electrical Cha

Is Now Part of To learn more about ON Semiconductor, please visit our website at

AND8312/D. A 36W Ballast Application with the NCP5104

N-Channel Logic Level Enhancement Mode Field Effect Transistor. Features. TA=25 o C unless otherwise noted

MPSL51. Amplifier Transistor PNP Silicon MAXIMUM RATINGS. THERMAL CHARACTERISTICS

KA431 / KA431A / KA431L Programmable Shunt Regulator

FDS8949 Dual N-Channel Logic Level PowerTrench MOSFET

Is Now Part of To learn more about ON Semiconductor, please visit our website at

NSVEMD4DXV6T5G. Dual Bias Resistor Transistors. NPN and PNP Silicon Surface Mount Transistors with Monolithic Bias Resistor Network

AND9518/D DAB L-band Amplifier using the NSVF4020SG4

FDMA3028N. Dual N-Channel PowerTrench MOSFET. FDMA3028N Dual N-Channel PowerTrench MOSFET. 30 V, 3.8 A, 68 mω Features. General Description

NCP800. Lithium Battery Protection Circuit for One Cell Battery Packs

PIN Diode Dual series Pin Diode for VHF, UHF and AGC 50V, 50mA, rs=max 4.5Ω, MCP

NTHD4502NT1G. Power MOSFET. 30 V, 3.9 A, Dual N Channel ChipFET

LM339S, LM2901S. Single Supply Quad Comparators

MM74HC14 Hex Inverting Schmitt Trigger

NTK3139P. Power MOSFET. 20 V, 780 ma, Single P Channel with ESD Protection, SOT 723

HMHA281, HMHA2801 Series. 4-Pin Half-Pitch Mini-Flat Phototransistor Optocouplers

Overview The LA1225MC is a Low-voltage operation (1.8V or higher) FM IF detector IC for the electronic tuning system.

NTNS3164NZT5G. Small Signal MOSFET. 20 V, 361 ma, Single N Channel, SOT 883 (XDFN3) 1.0 x 0.6 x 0.4 mm Package

Transcription:

SPS1M-EVK SPS1M-EVK Battery Free Wireless Sensor Handheld Evaluation System EVAL BOARD USER S MANUAL Introduction This guide describes how to use the Handheld Evaluation System to carry out sensor measurements using Magnus S technology. The system consists of the handheld reader, charger, cradle, and sample sensor tags. The reader is pre loaded with application software which reads sensor tags and reports results with a single button click. If the reader sees more than one sensor tag, it will measure the tag with the highest reported received power, and ignore the others. The cradle is used for connecting the reader to a PC. This is generally only required for updating the software on the reader; it is not necessary for normal use. The reader has a power plug for charging without the cradle. To use the cradle, plug in the USB cable and power cable to the back of the cradle, and connect the USB cable to the PC. Insert the reader vertically into the cradle and then rotate the reader backward to lock it in place (Figure 1). If Windows does not recognize the reader, install the driver software in the WinDriverInstall folder provided with this Evaluation System. Figure 1. Connecting the Reader to the Cradle When the reader is connected, Windows should automatically install the driver necessary to communicate with it, and the Windows Mobile Device Center will launch. Access the reader memory by selecting Connect without setting up your device, and then Browse the contents of your device under File Management. See Figure 2. Figure 2. Accessing Reader Memory through a PC Connection Semiconductor Components Industries, LLC, 2016 March, 2016 Rev. 1 1 Publication Order Number: EVBUM2324/D

Launching Sensor Software To launch the handheld Sensor software, double click the My Device icon on the Desktop. Then double click Flash, then the Sensor_xxxxx folder, and finally the Sensor icon as shown in Figure 3. At startup, the handheld screen looks like the screenshot in Figure 4. The following controls are available: Read button: Starts the sensor read process. Pressing the round yellow button on the keypad also starts a read Setup button: Opens the Setup screen with additional controls Sound button: Toggles on and off the beep which sounds when a read is complete The battery indicator is at the bottom of the screen. It gives the battery charge percentage or reads Charging when the unit is plugged in. Figure 3. Launching the Sensor Software Figure 5. Setup Screen Figure 4. Main Screen The following controls are available: Buttons Back: Returns to the main screen Advanced: Opens the Advanced screen with additional settings Exit: Quits the application Pulldowns Trip Below: When the measured Sensor Code is lower than this value, the main screen can optionally display a message and a background color C / F: For temperature measurements, chooses Celsius or Fahrenheit units The Setup screen is shown in Figure 5. 2

AutoPw RSSI: Sets the minimum and maximum target values for the AutoPower feature. See Section 2.6. Max Power: Sets the maximum power level the unit will use. Larger numbers correspond to lower powers. Display: Sets the output type to be displayed when the read completes. See Section 2.5. Checkboxes Autopower: Activates the AutoPower function. See Section 2.6. Dashboard: Replaces the logo with the Dashboard which provides more detailed information about the result of a sensor tag read. See Section 2.7. High Precision: Activates High Precision mode. In this mode, the unit will make 30 read attempts before displaying the results. This mode is recommended for temperature measurements and for Sensor Code measurements when precise values are desired. When turned off, 10 reads are attempted. Fast: Activates Fast mode. This mode will display a result as quickly as possible, at the cost of lower precision. The Advanced screen is shown in Figure 6. Figure 6. Advanced Screen The following controls are available: Pulldowns Region: Sets the RFID frequency band to use. Setting to a band not corresponding to the reader hardware will result in reduced performance. Algorithm: Sensor Code values generally vary linearly with the frequency channel on which they are read. This pulldown selects whether the final result will be the average of the individual reads, or will be computed by performing a linear regression analysis on the data. See Application Note AN006 for more information. Trip Color: If the Sensor Code result is below the trip value defined in the Setup screen, the result will displayed with this background color. Trip Phrase: If the Sensor Code result is below the trip value defined in the Setup screen, this phrase will be displayed. No Trip Color: If the Sensor Code result is above the trip value defined in the Setup screen, the result will displayed with this background color. No Trip Phrase: If the Sensor Code result is above the trip value defined in the Setup screen, this phrase will be displayed. Save Profile: Settings can be saved to one of five profiles, which will be stored on text files in Flash memory. This pulldown selects the profile number to be saved to. Any settings saved to profile 0 will be loaded automatically when the application is launched. Read Profile: Selects the stored settings profile number to be read from. Buttons Save: Save settings to the selected profile number Read: Load settings from the selected profile number Apply: Applies any changed settings and returns to the Setup screen Result Types The unit can display three different types of results: the Sensor Code, temperature, and the On-Chip RSSI Code. Sensor Code The Sensor Code is a value between 0 and 31 for Magnus S2 tags, and between 0 and 511 for Magnus S3 tags. It varies depending on the environment of the tag and can be used to sense multiple quantities depending on the design of the tag antenna. On-Chip RSSI Code The On Chip RSSI Code is a value between 0 and 31 which indicates how much power the tag is receiving from the reader (higher values indicate more power). The On Chip RSSI code is used by the AutoPower function to control the amount of power the unit transmits to the tag. Temperature The unit can read the temperature code from the tag and convert it to a value in degrees C or F. To perform the conversion, the unit automatically reads temperature calibration information stored in the Magnus S chip. Only Magnus S3 tags support temperature measurements. AutoPower and On-Chip RSSI Sensor and temperature results can be distorted if the sensor tag receives high levels of power from the reader (see Application Note AN006 for more information). Because of this, the reader transmit power should be reduced if the 3

sensor tag is receiving enough power to cause distortion. The power should not be turned down too low, however, or reads could become unreliable. The AutoPower function addresses this issue, and it is recommended that AutoPower be turned on for sensor and temperature measurements. The AutoPower function measures the power received by the sensor tag by reading the On Chip RSSI Code. It then adjusts the reader transmit power and attempts to achieve an On Chip RSSI value within the range specified in the AutoPower RSSI pulldowns in the Setup screen. The recommended minimum and maximum target On-Chip RSSI values are 16 and 21. AutoPower attempts to quickly find a transmit power which results in an On-Chip RSSI within the target range, but is not guaranteed to succeed. If the average On-Chip RSSI value reported from the tag is outside the target range, a warning triangle will appear with the message RSSI target not met. If the On-Chip RSSI exceeds the upper target limit, the accuracy of the sensor or temperature measurement could be impacted. Figure 7. RSSI Target Not Met Warning Dashboard When the Dashboard is turned on, the logo is replaced by more detailed information about the measurement. This is explained in Figure 8. Figure 8. The Dashboard Feature 4

Read Counts An individual measurement consists of multiple Sensor or Temperature Code reads. Taking multiple readings corrects for channel-frequency dependence in the Sensor Code and reduces random noise in the sensor and temperature measurements. It is possible for some of the reads in a measurement to fail. The reader will report a result if only some reads succeed, but the accuracy of the result may be reduced. If fewer than half of the read attempts in a measurement are successful, a warning triangle will appear with the message Few reads (Figure 9). The Dashboard can be used to determine how many reads succeeded in a measurement. SPS1M EVK Figure 10. Proper Reader Antenna and Tag Orientation Read Time The read process begins when the yellow read button on the touch screen or keypad is pressed. A progress bar will appear on the screen to indicate the progress of the read. The read process can take up to several seconds to complete. The reader should be held still during the read process. Click the Cancel button to stop the read process before it completes (Figure 11). Figure 9. The Few reads Warning Making Measurements Antenna Orientation The reader antenna must extended (folded out from the reader body) before reading tags. The RF beam is directed outward and perpendicular to the face of the antenna. The reader antenna should be aimed at the sensor tag, and the tag oriented such that its long axis is perpendicular to the RF beam (Figure 10). Figure 11. The Read Progress Bar and Cancel Button Maximum Read Range The maximum distance at which a tag can be read depends on the design of the tag and the surface it is placed upon. Also, nearby objects can reflect the reader signal and cause multipath interference. Because of factors like these, the maximum read range cannot be precisely predicted in advance. In general, the handheld reader is designed to read tags from a distance of 1 to 2 meters. 5

Temperature Measurements Temperature can be read from the Magnus S3 based sensor tag. Set the Display value in the Setup screen to Temperature. High Precision and AutoPower mode will be automatically selected. Moisture Measurements Moisture measurements can be made with the Moisture Sensor tag. Set the Display value in the Setup screen to Sensor Code. AutoPower mode will be selected by default. The presence of moisture on the interdigitated capacitor of the tag will change the Sensor Code reading. Generally, moisture will cause a reduction in the Sensor Code value. The surface on which the tag is placed can also affect the Sensor Code, so the tag should stay in the same place under both dry and wet conditions. Illustrative results are given in Figure 12. Figure 12. Sensor Code changes when a water droplet is placed on the tag The Moisture Sensor tag can also detect a fine mist sprayed or wiped on the interdigitated capacitor area. Troubleshooting If the reader cannot read sensor tags, or only reads tags from a short distance, try the following steps Verify that the maximum reader power is set to 0. Move the tag to a different location or surface Rotate the reader 45 degrees while still pointing the surface of the antenna at the sensor tag Fully recharge the reader Reset the reader as described in Section 4.1. Resetting the Reader The reader can be reset to its factory settings with the process below. This will not delete the Sensor software from the flash memory. 1. Exit out of any application that may be running. 2. Start Nordic ID s demo program: Start Programs RFID RFID Demo 3. Restore factory defaults: Settings Save Factory default Save Settings 4. Exit the demo program: Main Menu Exit 5. Reset Windows Registry to default: Start Programs Nordic ID Registry Backup Factory Default Defaults Yes 6. Reload Windows CE: Push the power button in the lower right-hand corner of the keypad, select Reload Windows CE, then click Reload in the lower left-hand corner of the screen. Follow the instructions to re-calibrate the stylus input. Magnus is a registered trademark of RFMicron. ON Semiconductor and the are registered trademarks of Semiconductor Components Industries, LLC (SCILLC) or its subsidiaries in the United States and/or other countries. SCILLC owns the rights to a number of patents, trademarks, copyrights, trade secrets, and other intellectual property. A listing of SCILLC s product/patent coverage may be accessed at /site/pdf/patent Marking.pdf. SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does SCILLC assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages. Typical parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including Typicals must be validated for each customer application by customer s technical experts. SCILLC does not convey any license under its patent rights nor the rights of others. SCILLC products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other applications intended to support or sustain life, or for any other application in which the failure of the SCILLC product could create a situation where personal injury or death may occur. Should Buyer purchase or use SCILLC products for any such unintended or unauthorized application, Buyer shall indemnify and hold SCILLC and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that SCILLC was negligent regarding the design or manufacture of the part. SCILLC is an Equal Opportunity/Affirmative Action Employer. This literature is subject to all applicable copyright laws and is not for resale in any manner. PUBLICATION ORDERING INFORMATION LITERATURE FULFILLMENT: Literature Distribution Center for ON Semiconductor 19521 E. 32nd Pkwy, Aurora, Colorado 80011 USA Phone: 303 675 2175 or 800 344 3860 Toll Free USA/Canada Fax: 303 675 2176 or 800 344 3867 Toll Free USA/Canada Email: orderlit@onsemi.com N. American Technical Support: 800 282 9855 Toll Free USA/Canada Europe, Middle East and Africa Technical Support: Phone: 421 33 790 2910 Japan Customer Focus Center Phone: 81 3 5817 1050 6 ON Semiconductor Website: Order Literature: http:///orderlit For additional information, please contact your local Sales Representative EVBUM2324/D