STANDARD IDENTIFICATION MARKING. Prepared by. UTC Aerospace Systems Interiors Fairfield, CA CAGE Code ORIGINAL DATE: UNKNOWN

Similar documents
NUMBER SOP STANDARD POLICIES AND PRACTICES PAGE 1 OF 4. April 15, 2012 STANDARDIZED PART MARKING PRACTICES REVISES POLICY DATED: July 1, 2010

PROCESS SPECIFICATION PART MARKING STANDARDS

SPECIFICATION FOR IDENTIFICATION MARKING OF PARTS S-3006

Alfa Laval Material Standard T

UNSIGNED HARDCOPY NOT CONTROLLED. Reference Designation Marking and Miscellaneous Coding

1.2 Application. The Metalphoto and photo-etch processes covered by this specification shall be used as specified in the following subparagraphs.

PS901500E IDENTIFICATION, MARKING, HANDLING, PROCESSING AND INSPECTION OF CRITICAL PARTS

QUALITY ASSURANCE SPECIFICATION

Student ID: Exam: RR - Introduction to Print Reading

DEPARTMENT OF DEFENSE MANUFACTURING PROCESS STANDARD IDENTIFICATION MARKING REQUIREMENTS FOR SPECIAL PURPOSE COMPONENTS

(R) Aerospace First Article Inspection Requirement FOREWORD

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017

JED Specification

TEXAS DEPARTMENT OF TRANSPORTATION GENERAL SERVICES DIVISION PLAQUE, SERVICE AWARD PUBLICATION

ATI Evaluation Service A Division of Architectural Testing Certification Services

Advantages, Function and Characteristics of the DMwriter MX.

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

Piping & Equipment Identification

METAL FABRICATION SECTION 8: METAL FABRICATION SCOPE MATERIAL.

AS9102 Training. First Article Inspection Guide. Rev A

DIRECT PART MARKING THE NEXT GENERATION OF DIRECT PART MARKING (DPM)

SECTION MECHANICAL IDENTIFICATION

A. Product Data: For each electrical identification product indicated.

Chapter 9: Truss Preparation

P.L. 1999, CHAPTER 258, approved October 15, 1999 Assembly, No (First Reprint)

SECTION IDENTIFICATION FOR HVAC PIPING, DUCTWORK AND EQUIPMENT

B. Samples: For color, letter style, and graphic representation required for each identification material and device.

Excavating, Backfilling, and Compaction for Utilities Piping (Plumbing).

WATER MAIN ALONG ENTRANCE TO ENCINO PS / HWY 281 TO ENCINO TANK Solicitation Number: CO Job No.:

SECTION SUBMITTALS. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SPECIFICATION FOR RUBBER INSULATING GLOVES FOR LOW VOLTAGE 500V

Fallbrook Art Association Gallery Monthly Show Rules and Information

SECTION MECHANICAL IDENTIFICATION. 1. Identification of mechanical products installed under Division 15.

Marking and engraving Solutions for OIL & GAS industry

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

BAE Systems Combat Vehicles Supplier Quality Assurance AS9102 Requirement

1.0 INTRODUCTION DEFINITIONS DRAWING CONTROL PREPARATION OF SPECIFICATIONS AND DATASHEETS... 5

SECTION SUBMITTAL PROCEDURES

SECTION MECHANICAL IDENTIFICATION

Section 914. JOINT AND WATERPROOFING MATERIALS

SECTION IDENTIFICATION OF PLUMBING, PIPING AND EQUIPMENT. A. Section includes nameplates, tags, stencils and pipe markers.

QUALITY CONTROL INSTRUCTIONS

Engineering Drawing System

SECTION IDENTIFICATION OF HVAC PIPING AND EQUIPMENT. A. Section includes nameplates, tags, stencils and pipe markers.

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section ELECTRICAL IDENTIFICATION

FORMAT: TO BE PREPARED ON VENDOR S FORMAT IN ACCORDANCE WITH VENDOR S PDDS SYSTEM.

Cosmetic Inspection Standard for Nameplates

This specification describes the minimum requirements for piping systems for the following service:

Engineering Services Program

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION MANHOLES

Supplier Quality Requirements for First Article Inspection SQR-011. Revision Date: 16 March 2011

Did you know that the numbers on a limited edition print actually mean something?

Marking and Engraving Solutions for the OIL & GAS industry

Required Supporting Information and Documentation for Historic Preservation Certification Applications

MILITARY SPECIFICATION SHEET SCREW, CAP, SOCKET HEAD- HEXAGON, CORROSION RESISTANT STEEL, UNC-3A

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

This specification describes the minimum requirements for service water piping systems (ie: cooling water, process water, etc.), located on surface.

Identification Marking Processes for Aircraft Parts

Ballooned by InspectionXpert. User: Brittany Belsito ; Expires: :33

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Categories of acceptable media are:

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION

Australian/New Zealand Standard

Copper & Magnesium Die Prices

Fast and Affordable Customization.

1. ASME A Scheme for the Identification of Piping Systems.

TEST PROCEDURE FOR DYNAMIC PULL-OFF PERFORMANCE OF ROOFING FASTENER HEADS OR FASTENERS WITH BEARING PLATES

DETAIL SPECIFICATION SHEET CONNECTORS, ELECTRICAL, MODULAR, TYPE IV, CONNECTOR, 200 CONTACT, CENTER

SECTION ELECTRICAL IDENTIFICATION

ISO 2575 INTERNATIONAL STANDARD. Road vehicles Symbols for controls, indicators and tell-tales

60 terms in printmaking

CESSNA QUALITY REQUIREMENTS. For SUPPLIERS (CQRS)

th St N Oak Park Heights, MN Phone: Fax:

Copper & Magnesium Die Prices. Contents. Prices...Page 2 Special Charges...Page 3 Tech Tips...Page 4 Contact Info...Page 5

Des Moines Stamp Manufacturing Company

Weldment Visual Inspection Requirements

SECTION PANELBOARDS

3400 Tectura Designs Precast Concrete

Rustic Trophy Originals NEW 2018

Identification cards Physical characteristics

SECTION IDENTIFICATION SIGNS. A. Plastic Signs, raised character, tactile, room identification, exit door signs, and non-tactile signs.

AN Starter guide PCB tagging. Rev Jan Application note PUBLIC. Document information

Occasional Tables 1 Technical Specifications. Occasional Tables

Cloud Based Plan Review Process (Applicant)

This specification describes the minimum technical requirements for drawings, as applicable to all disciplines.

Provläsningsexemplar / Preview

Anjani Technoplast Ltd. Components Manufacturing

Installation Instructions

CSP PSYCHIATRIC SERVICES UNIT SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

B. Bidders shall acknowledge receipt of this Addendum in writing on his Proposal Form.

AEROSPACE MATERIAL SPECIFICATION

SECTION MECHANICAL IDENTIFICATION

AS9102B - APPLICABLE TO FORM # 1, 2, 3

Manufacturing Instructions Requirements and principles

DOCUMENT ADDENDUM NO. 4. Issued to all Bidders: Date: October 14, Contract Name: Electrical Installation. Contract Number: C8410

Engineering Drawing System

DETAIL SPECIFICATION PLATES AND TAGS FOR IDENTIFICATION OF EQUIPMENT, GENERAL SPECIFICATION FOR

SECTION IDENTIFICATION FOR FIRE SUPPRESSION PIPING AND EQUIPMENT

Transcription:

STANDARD 4.2.1-1 IDENTIFICATION MARKING Prepared by UTC Aerospace Systems Interiors Fairfield, CA 94533 CAGE Code 17610 ORIGINAL DATE: UNKNOWN THIS DOCUMENT IS THE PROPERTY OF UTC AEROSPACE SYSTEMS. YOU MAY NOT POSSESS, USE, COPY OR DISCLOSE THIS DOCUMENT OR ANY INFORMATION IN IT, FOR ANY PURPOSE, INCLUDING WITHOUT LIMITATION, TO DESIGN, MANUFACTURE OR REPAIR PARTS, OR OBTAIN ANY GOVERNMENT APPROVAL TO DO SO, WITHOUT UTC AEROSPACE SYSTEMS EXPRESS WRITTEN PERMISSION. NEITHER RECEIPT NOR POSSESSION OF THIS DOCUMENT ALONE, FROM ANY SOURCE, CONSTITUTES SUCH PERMISSION. POSSESSION, USE, COPYING OR DISCLOSURE BY ANYONE WITHOUT UTC AEROSPACE SYSTEMS EXPRESS WRITTEN PERMISSION IS NOT AUTHORIZED AND MAY RESULT IN CRIMINAL AND/OR CIVIL LIABILITY. xclass = 5043543

APPROVAL SIGNATURE PAGE IDENTIFICATION MARKING i

REVISIONS REV DATE CHANGE DESCRIPTION RELEASE DATE A 05/01/82 Refer to 4.2.1-1(A) B 07/01/83 Refer to 4.2.1-1(B) C 05/10/84 Refer to 4.2.1-1(C) D 01/08/87 Refer to 4.2.1-1(D) E 10/12/94 Refer to 4.2.1-1(E) F 06/20/96 Refer to 4.2.1-1(F) G 07/29/05 Refer to 4.2.1-1(G) 08/19/05 H 10/01/07 Refer to 2.4.1-1(H) 01/28/08 J 01/08/10 Refer to 2.4.1-1(J) 02/10/10 K 03/31/16 Refer to the following revision page. 04/29/16 ii

PARAGRAPH CHANGE DESCRIPTION Throughout document Table Is: UTAS Was: Goodrich/UPCO Revised table to allow the use of an ink marking machine. iii

IDENTIFICATION MARKING 1. SCOPE This document describes marking methods to be used, when required, to identify any material, part, assembly or system produced or procured by UTAS. All marking methods shall be subject to the following requirements: (a) (b) (c) (d) (e) (f) Marking shall be legible. Marking shall not damage parts or adversely affect intended use. Permanent marking shall not be placed on bearing surfaces or within 1/32 inch of any edge, fillet or corner. Letter or number height shall be 1/16 inch, minimum, unless otherwise specified on drawing. Marking format shall consist of the part number, dash number (if applicable) and revision letter, e.g. 60615-1A, 12350100-1B. If required, part shall be permanently serialized. A serial number shall consist of the purchase order number with a dash and a 4 digit sequential number starting with -0001. 1

CODE MARKING TYPE METHOD A INK MARKING Mark using black permanent ink using marking pen, rubber stamp, machine marking, etc.. When marking on dark materials use white permanent ink B RUBBER STAMP OR MARKING PEN - PROTECTED Mark as in Code A except apply protective overcoating of clear sealant. C TAG Mark on tag by any suitable means and attach to part. (Use when direct marking is impractical or undesirable.) D BAG AND TAG Mark directly on bag or on tag attached to bag using any suitable method. E VIBRA-TOOL Mark, using electric vibra-tool, to a maximum depth of 0.005 inch. (Do not use on notch-sensitive material.) F ELECTROLYTIC ETCH Mark using electrolysis method confined by prepared stencil. Maximum etch depth shall be 0.005 inch on materials to 0.100- inch thick, and 0.002/0.005 inch on materials over 0.100- inch thick. (Use on conductive material only.) G IMPRESSION Mark by material displacement method, e.g. steel stamping or pressing. Maximum impression depth shall be 0.010 inch. (Do not use on notch sensitive material.) H CONTAINER Identify container using stencil method, marking pen, or prepared label. I INTEGRAL RAISED Mark by molding, casting or forging. Character height (raised) shall be 0.100 0.030 inch. J INTEGRAL Same as I except character depth shall be 0.100 0.030 inch. DEPRESSED K OPTIONAL Mark per code A, B, E or F optional 2

CODE MARKING TYPE METHOD L LABEL-PRESSURE SENSITIVE OR BONDED Mark on label and apply to part. Reference label drawing, if applicable. M CRITICAL FINISH Wrap each item in suitable protective packaging material and apply marking to package by the referenced marking code or, if no code is reference, by a method that will not damage the item. (Use on parts with critical or delicate finishes.) N LASER MARKING Permanently mark each part with a laser, to a maximum depth of 0.005 inch. O CNC ENGRAVE/ PAINT CNC Engrave characters, to minimum depth of 0.010-inch and fill with black oil-base paint; unless color is otherwise specified. (Example: NOTE CODE o, RED.) P VIBRA-TOOL/ PAINT Mark, using electric vibra-tool, to a maximum depth of 0.005 inch and fill with black oil-base paint; unless color is otherwise specified. (Example: NOTE CODE P, RED.) (Do not use on notch-sensitive material.) 3