SINVERT. Technical requirements for medium-voltage transformers for use with SINVERT central inverters. Application manual 04/2012

Similar documents
SIMATIC Ident RFID systems ANT 3 Compact Operating Instructions

Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC

SINAMICS drives. SINAMICS DCM as a DC voltage source. Application. Answers for industry. Edition 01/2014

SINAMICS DCM. DC converter Application - 12-pulse parallel connection with decoupled interphase transformer. Introduction 1

SINAMICS drives SINAMICS DCM. DC converters from 6 kw to 2500 kw for variable-speed direct-current drives

SIMATIC Ident. RFID systems SIMATIC RF615A. Characteristics 1. Ordering data. Installing and mounting. Connecting the antenna 4

SIMATIC ET 200SP. Digital input module DI 8xNAMUR (6ES7131-6TF00-0CA0) Manual. Answers for industry.

SIMATIC RTLS. Localization systems SIMATIC RTLS PCB OEM AX (6GT2700-8DF00-0AX0) Device manual 10/2018 C79000-G8976-C518-01

SIMATIC Vision Sensor SIMATIC VS130-2 and VS 130-2vcr

Analog input module AI 8xU BA (6ES7134-6FF00-0AA1) SIMATIC. ET 200SP Analog input module AI 8xU BA (6ES7134-6FF00-0AA1) Preface. Documentation guide 1

SIMATIC. ET 200S distributed I/O 2AI U HF analog electronic module (6ES7134-4LB02-0AB0) Preface. Properties 1. Parameters 2.

Isometrics COMOS. Process Isometrics. Trademarks 1. Introduction 2. Project structure 3. Isometric report 4. Engineering with COMOS Isometrics

SINAMICS drives SINAMICS DCM. Commutation reactors. Operating Instructions. Answers for industry. Edition 11/2013

Technical Information Requirement for MV Transformers and Transformer for Internal Power Supply for SUNNY CENTRAL

Technical Information Requirement for MV Transformers and Transformer for Internal Power Supply for SUNNY CENTRAL

SIMATIC. ET 200S distributed I/O 2AI I 4WIRE HS analog electronic module (6ES7134-4GB62-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC Ident RFID systems SIMATIC RF310R special version Scanmode Compact Operating Instructions

SIMATIC. ET 200S distributed I/O 2AI U HS analog electronic module (6ES7134-4FB52-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC Ident. RFID systems SIMATIC RF200 IO-Link V1.1. Introduction 1. Description. System overview. Planning an RF200 IO-Link system 4

Analog input module AI 2xI 2/4-wire ST (6ES7134-6GB00-0BA1) SIMATIC. ET 200SP Analog input module AI 2xI 2/4-wire ST (6ES7134-6GB00-0BA1) Preface

Technology module TM Pulse 2x24V (6ES7138 6DB00 0BB1) SIMATIC ET 200SP (6ES7138 6DB00 0BB1) Preface. Documentation guide.

13 A. Temperature regulator FM SIMATIC. S7-300 Temperature regulator FM Preface. Product Overview

SITRANS TH200/TH300 SITRANS T. Temperature transmitter SITRANS TH200/TH300. Introduction 1. General safety notes. Description 3.

COOPER POWER SERIES. External application of a motor start capacitor on a single-phase voltage regulator. Voltage Regulators MN225063EN

Analog input module. AI 2xU/I 2-/4-wire HF (6ES7134-6HB00-0CA1) SIMATIC. ET 200SP Analog input module AI 2xU/I 2-/4-wire HF (6ES7134-6HB00-0CA1)

Low-Voltage Power Distribution and Electrical Installation Technology

Product Manual SENTRON. Measuring Devices 7KM PAC3200T. siemens.com/lowvoltage

SIMATIC. S7-1500/ET 200MP Technology Module TM PTO 4 (6ES7553-1AA00-0AB0) Preface. Documentation guide. Product overview.

Positioning SIMATIC. ET 200S Positioning. Preface 1 1STEP 5V. 1PosUniversal. Operating Instructions 06/2010 A5E

Analog Input Module. AI 4xU/I/RTD/TC ST (6ES7531-7QD00-0AB0) SIMATIC. S7-1500/ET 200MP Analog Input Module AI 4xU/I/RTD/TC ST (6ES7531-7QD00-0AB0)

Siemens AG New portfolio for reliable personnel, material and fire protection

N-Channel 2.5-V (G-S) Battery Switch, ESD Protection

Galaxy VM. Kit for IP32. Installation 06/

Service Manual for Installers Troubleshooting for Power-Line Communication SUNNY BOY 240-US / SUNNY MULTIGATE-US

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

SUNNY BEAM REPEATER Transmission Range Increase for Sunny Beam

External brake resistor AX2090-BW5x

NOsparc! MHXAC1F120! MHXAC1F240! MHXAC1F480 PATENTS AND PATENTS PENDING. Contact Arc Suppressor

SINAMICS. OALINK Open Application Link. Communication between two Control Units via DRIVE-CLiQ. Function Manual. Answers for industry.

Bulletin 509 Three Phase Full Voltage NEMA Starters Size 9 Series A. Renewal Parts

TA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

Function Manual Basic Positioner SINAMICS. SINAMICS G120 Function Manual Basic Positioner. Introduction. Basic positioner. Appendix.

Standard Recovery Diodes, 400 A

Single Phase Rectifier Bridge, 1.9 A

Analog electronic module SIMATIC. ET 200S distributed I/O Analog electronic module 2AI TC ST (6ES7134-4JB01-0AB0) Preface. Properties.

Installation Instructions

CPH Coulter Tool Bar Brace Assembly

CDN 117 / 117-M CDN 118-T4 / 118-EXT-1 SIGNAL & DATA LINE COUPLING NETWORKS USER MANUAL M

Optocoupler, Phototransistor Output, High Reliability, 5300 V RMS

Single Phase Bridge Rectifier, 2 A

High Voltage Glass Passivated Junction Plastic Rectifier

MSP3V3, MSP5.0A. Surface Mount TRANSZORB Transient Voltage Suppressors. Vishay General Semiconductor. FEATURES. Series.

VACUUM INTERRUPTER APPLICATION NOTES Filename: VIAN X-Rays and Vacuum Interrupters Revision: 0 PAGE 1

Technical manual. Microstep driver SMC11. NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D Landsham near Munich, Germany

Low-Voltage Power Distribution and Electrical Installation Technology

General Purpose Plastic Rectifier

JBus/Modbus Communication Card

Accessories Solar Datatechnology Wireless-Set485-01/-Set485-02

Optocoupler, Phototransistor Output, no Base Connection

Dual Common-Cathode Ultrafast Rectifier

VT1586A Rack Mount Terminal Panel Installation and User s Manual

Single phase bridge. (Power Modules), 25 A / 35 A

Optocoupler, Phototransistor Output, High Reliability, 5300 V RMS

Series NRX with PXR - Instructions for Neutral Current Sensor Type NF

C-Bus 8 Channel Low Voltage Relay

Fast Switching Plastic Rectifier

UF4001, UF4002, UF4003, UF4004, UF4005, UF4006, UF4007 Ultrafast Plastic Rectifier

SIMATIC. ET 200S distributed I/O Analog electronic module 4AI TC ST (6ES7134-4JD00-0AB0) Preface. Properties 1. Parameters 2.

Agilent G1888 Network Headspace Sampler

Single phase bridge. (Power Modules), 25 A/35 A

Optocoupler, Phototransistor Output, High Reliability, 5300 V RMS

Small Signal Switching Diode, Dual

Three phase bridge. (Power Module), 200 A

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

RWN, RWS. Operating Instructions. FLENDER couplings RUPEX. 3601en. Edition 03/2017.

SITRANS. Process monitoring SITRANS DA400 for Feluwa hose diaphragm piston pumps. Introduction. General safety instructions 2.

Dynamo Brushless DC Motor and GreenDriveTM Manual

Multi SMD LED RGB FEATURES APPLICATIONS MIN. TYP. MAX. MIN. TYP. MAX. MIN. TYP. MAX.

SIMATIC ET 200SP. Motor Starter (3RK1308-0**00-0CP0) Manual. siemens.com. Edition 12/2016

Thin Film Mini-MELF Resistors

Standard SMD LED PLCC-2

Three Phase Bridge, 130 A to 160 A (Power Modules)

Thin Film Rectangular Chip Resistors

Single Phase Rectifier Bridge, 1.9 A

High Voltage Generation

Operating Instructions Edition 04/2007. Temperature Transmitter SITRANS TR200/TR300 7NG3032-*JN00 SITRANS TR200 7NG3033-*JN00 SITRANS TR300.

SIMOREG DC-MASTER. Application 12-Pulse Parallel Applications. 6RA70 Series

GV3000/SE AC Drive HP, 460V AC

SINAMICS. VIBX Vibration Extinction. Function Manual

Optocoupler, Phototransistor Output, Very High Isolation Voltage

Ultrafast Plastic Rectifier

Optocoupler, Power Phototriac

Pulse Load Carbon Film MINI-MELF Resistors for High Frequency Applications

Dual Common Cathode Ultrafast Rectifier

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

Glass Passivated Junction Plastic Rectifier

Standard Recovery Diodes (Stud Version), 12 A

Power Rectifier Diodes (T-Modules), 2200 V, 20 A

OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO-E

Single Phase Rectifier Bridge, 1.2 A

Transcription:

Technical requirements for medium-voltage transformers for use with SINVERT central inverters Application manual 04/2012 SINVERT Answers for the environment.

Technical requirements for medium- Technical requirements for medium-voltage 1 transformers voltage transformers for use with SINVERT central inverters SINVERT Technical requirements for mediumvoltage transformers for use with SINVERT central inverters Application manual 04/2012 A5E03827321-02

Legal information Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken. CAUTION without a safety alert symbol, indicates that property damage can result if proper precautions are not taken. NOTICE indicates that an unintended result or situation can occur if the relevant information is not taken into account. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. Trademarks All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Industry Sector Postfach 48 48 90026 NÜRNBERG GERMANY A5E03827321-02 P 04/2012 Technical data subject to change Copyright Siemens AG 2012. All rights reserved

Table of contents 1 Technical requirements for medium-voltage transformers... 7 1.1 Rated voltages and low-voltage infeed...7 1.1.1 Rated voltages...7 1.1.2 Low-voltage and high-voltage winding...7 1.1.3 Interconnection of the components...8 1.2 Voltage peaks and filtering...9 1.2.1 Transformer design...9 1.2.2 Design of surge arresters (AC-side)...9 1.3 Short-circuit voltages...9 1.4 Types of construction...10 1.5 Special requirements for oil-immersed transformers...10 Technical requirements for medium-voltage transformers for use with SINVERT central inverters Application manual, 04/2012, A5E03827321-02 5

Table of contents Technical requirements for medium-voltage transformers for use with SINVERT central inverters 6 Application manual, 04/2012, A5E03827321-02

Technical requirements for medium-voltage 1 transformers 1.1 Rated voltages and low-voltage infeed 1.1.1 Rated voltages The rated voltage is dimensioned to the respective low voltage dependent on the inverter type: Inverter SINVERT TL 500/1000/1500/2000 SINVERT PVS 500/1000/1500/2000 SINVERT PVS 585/1170/1755/2340 SINVERT PVS 600/1200/1800/2400 SINVERT PVS 630/1260/1890/2520 Rated voltage 328 V 288 V 340 V 370 V 370 V 1.1.2 Low-voltage and high-voltage winding Figure 1-1 Configuration example of a medium-voltage transformer 1200 kva (370 V / 370 V / 21 kv) Technical requirements for medium-voltage transformers for use with SINVERT central inverters Application manual, 04/2012, A5E03827321-02 7

Technical requirements for medium-voltage transformers 1.1 Rated voltages and low-voltage infeed A separate isolated low-voltage and high-voltage winding is required for each inverter subunit. If several low-voltage windings are available (four-winding transformer design), the transformer must be suitable for use with asymmetrical load of the low-voltage and highvoltage windings. The high voltage is selected between 8 kv and 66 kv dependent on country-specific, grid-operator-specific, and project-specific requirements. Note The country-specific grid frequency, standards and regulations, as well as the stipulations of the local grid operator must be complied with. 1.1.3 Interconnection of the components Figure 1-2 Basic principle of interconnecting components in the inverter station in a configuration with SINVERT PVS 2000 or SINVERT PVS 2400 inverters Technical requirements for medium-voltage transformers for use with SINVERT central inverters 8 Application manual, 04/2012, A5E03827321-02

Technical requirements for medium-voltage transformers 1.2 Voltage peaks and filtering 1.2 Voltage peaks and filtering 1.2.1 Transformer design The technical design of the transformer must be suitable for operation with pulsed inverters. The voltage peaks can reach ±1500 V to ground (pulses). The rms value of the voltages to ground must not exceed 800 V. The low-voltage winding must be designed for gradients du/dt up to max. 500 V/ µs to ground. For dry-type transformers, a shield winding (du/dt filter) between the low-voltage winding and the high-voltage winding can be dispensed with by means of appropriately implemented design measures. Overvoltage protection in accordance with VDE 0101, Section 5.2.2.7 (spark gaps to VDE 0532-14) is required for all transformers. 1.2.2 Design of surge arresters (AC-side) The surge arresters must be suitable for pulsed operation. The surge arrester must be effectively designed for voltages of ±1500 V and 800 V AC. One surge arrester must be installed per phase. It must be ensured that no grounding or artificial neutral point is caused by this installation. 1.3 Short-circuit voltages The short-circuit voltage Uk must be selected at 6%. In doing so, 5.4% to 6.6% must be maintained. With four-winding transformers, the short-circuit voltage between the low-voltage windings must be 10%. If the high-voltage winding is not connected, the measurement is carried out by shortcircuiting one low-voltage winding, and voltage infeed at the second up to the rated current. For thermal dimensioning, the respective site conditions and isolation classes must be taken into account. Technical requirements for medium-voltage transformers for use with SINVERT central inverters Application manual, 04/2012, A5E03827321-02 9

Technical requirements for medium-voltage transformers 1.4 Types of construction 1.4 Types of construction The permissible types of construction are Dy5Dy5 and Dy11Dy11. The neutral point must not be brought out on the low-voltage side. At least 5 voltage levels must be brought out on the high-voltage side: -5.0%, -2.5%, rated voltage, +2.5% and +5% Note In the case of thin-film modules, a range of up to -15% may be required, depending on the manufacturer. Since it is an infeed transformer, the rated voltage must be 5% higher than the rated grid voltage (rated grid voltage 20 kv, rated transformer voltage 21 kv). When using the transformer in conjunction with the Siemens 8DJH switchgear, the rated voltage of the transformer must not exceed 24 kv. 1.5 Special requirements for oil-immersed transformers If oil-immersed transformers are used, oil sumps must be provided and acceptance-tested by an appointed person depending on the location of use (water regulations). In water reserves, special permits must be obtained for transporting and using oil sumps. With oil-immersed transformers, a suitable du/dt filter shield winding must be provided between the low-voltage and high-voltage winding. This must be grounded on the tank. Technical requirements for medium-voltage transformers for use with SINVERT central inverters 10 Application manual, 04/2012, A5E03827321-02

Service & Support Download catalogs and information material: www.siemens.com/sinvert/infomaterial Newsletter - always up to date: www.siemens.com/sinvert/newsletter E-Business in the Industry Mall: www.siemens.comindustrymall Online-Support: www.siemens.com/sinvert/support Contact for all technical information: Technical Assistance Tel.: +49 (911) 895-5900 E-Mail: technical-assistance@siemens.com www.siemens.com/sinvert/technical-assistance Siemens AG Industry Sector Postfach 23 55 90713 FÜRTH GERMANY Subject to change without prior notice Order No.: A5E03827321-02 Siemens AG 2012 www.siemens.de/industry