Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Similar documents
Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Brief description. Type overview

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Technical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

11 VA Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque (nominal torque) Motor Spring return

Power consumption In operation At rest For wire sizing

Technical data. Parameterisable damper actuator in the

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

Functional data Factory settings Variable Settings

Technical data sheet. Technical data. Safety notes

Power consumption In operation At rest For wire sizing

Technical data. T2-SM230ASR en v Subject to changes / 3. Electrical data Nominal voltage AC

Technical data. Safety notes. Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing

Overview of types. Technical data

Technical data. Safety notes. T3-LR24A-SR en v Subject to changes 1 / 2

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

AC/DC 24 V, 50/60 Hz. Functional data Variable Settings. DC V, max. 0.5 ma. End point DC V... 4 ma ma Non-variable

Power consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A)

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation Vmax low-n: Vmax for low-noise operation

Technical data. Safety notes

Power consumption In operation At rest For wire sizing. 1.5 W at nominal torque 0.4 W 4 VA Connection Cable 1 m, 3 x 0.75 mm 2

Power consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Power consumption Operation At rest Wire sizing

Brief description. VAV-Compact MP en-gb Changes reserved 1. Application. Pressure measurement. Actuator

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Overview of types. Technical data. T5-NRDVX24-SR-T-.. en v Subject to changes 1 / 3

Technical data. Safety notes. T5-HT24-SR-T en v Subject to changes 1 / 3

Image. Installation VAV-Universal Retrofit-Set. General Information. Safety notes

Installation of VAV-Compact Retrofit with ZDMS-..

DN [ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Rp [ ] [ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Type overview. Technical data

Extension for ground plate Z-SMA. Shaft extension AV8-25. Reversible spindle clamp K-SA. Damper crank arm KH8. Extension from SM.. or AM.. to SM..A..

Adaptive control system for duct and room pressure applications. Table of Contents

Specification GRUNER YSP 227C

kvs theor.: Theoretical kvs value for pressure drop calculation Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

VAV solutions for comfort applications

Air damper actuators. OpenAir GDB..1E. Electronic motor driven actuators for open-close, three-position and modulating control

kvs theor.: Theoretical kvs value for pressure drop calculation Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

..-MF /..-MP /..-MFT(2) /..-MOD /..LON..-MF /..-MP /..-MFT(2) /..-MOD /..LON

Configured air damper actuators 6FU11xx-xDxxx-xxxx

Introduction to MP-Bus Technology

Air damper actuators. OpenAir GSD...1A. Electric motor-driven rotary actuators for open-close, three-position and modulating control

GM24-MFT US. Proportional damper actuator, non-spring return, Multi-Function Technology

EY-EM 527: Remote I/O module, ecolink527

VAV-Compact. Contents. Modbus General Notes 2 Modbus Register Overview 3 Modbus Register Description 4

Rotary actuators for ball valves

AC 01.2 HART Technical data Actuator controls

Spring Return DuraDrive Proportional Actuator

1-phase AC current voltages/frequencies Volt Volt

Belimo Gateway MP to BACnet MS/TP - UK24BAC

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

Rotary gear motor series AG8...

Electric thrust actuator. Electric thrust actuator ARI-PREMIO -Plus 2G. 2,2-5 kn. Electric thrust actuator. ARI-PREMIO -Plus 2G kn.

Technical Instructions Document No EA GQD October 25, OpenAir GQD Series

1. Function. Universal dimming actuator REG-K/2x230/ 300 W. Universal dimming actuator REG-K/230/ 500 W. Universal dimming actuator REG-K/230/ 1000 W

GLB...9. Ball Valve actuators. Building Technologies HVAC Products. for valves VAI61... AC 24 V / AC 230 V

7.2 DV1311.L08 and DV1311.L12

Technical Instructions Document No EA GQD June 23, OpenAir

02/11/2015

02/11/2015

Technical manual GS 4x.00 knx application description air quality sensor

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Air damper actuators Rotary version with spring return, AC 24 V / DC V / AC 230 V

1-phase AC current Voltages/frequencies Volt Volt 110, 115, , 230, 240 Hz Hz 60 50

Air Water Actuators xm(c)24a-mod xr24a-mod xv(k)24a-mod xf24a-mod xrf24a-mod

MODEL: MRP6. Final Control Elements

AC 01.2 Modbus TCP/IP

SAL.. ACVATIX Electromotoric rotary actuators for butterfly or slipper valves. with 90 rotary angle

PRODUCT MANUAL. ABB i-bus KNX VC/S 4.x.1 Valve Drive Controller

1-phase AC current Voltages/frequencies Volt Volt 110, 115, , 230, 240 Hz Hz 60 50

Non-Spring Return DuraDrive Modulating Actuator

GMU24. Technical data. Dimensions [mm] For operation of air control dampers in HVAC system Torque: 40Nm Nominal voltage: AC/DC 24V Control: Open/Close

Electronic Air / Fuel Ratio Control System

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

NRT 105: Electronic fan-coil controller, equiflex

02/11/2015

Electromotoric actuators for stroke valves

TA-Slider 160 KNX Protocol Implementation

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Room Sensors. for relative humidity and temperature

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Room Sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range

02/11/2015

Transcription:

echnical data sheet LM24A-KNX Communicative damper actuator for adjusting dampers in technical building installations Nominal torque 5 Nm Nominal voltage AC/DC 24 V Conversion of sensor signals echnical data Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency 50/60 Hz Nominal voltage range AC 19.2...28.8 V / DC 21.6...28.8 V Power consumption in operation 2.5 W Power consumption in rest position 1.3 W Power consumption for wire sizing 5 VA Connection supply / control Cable 1 m, 6 x 0.75 mm² Data bus communication Medium KNX P Number of nodes max. 64 per line segment, reduce number of nodes with connection cable with short lines Operating mode S-Mode Stromaufnahme von KNX-Bus Max. 5 ma Projektierungs- und Inbetriebnahme-ool ES4 or higher Functional data orque motor Min. 5 Nm orque variable 25%, 50%, 75% reduced Position accuracy ±5% Direction of motion note Y = 0%: At switch position 0 for ccw rotation or 1 for cw rotation, respectively Direction of motion variable electronically reversible Manual override with push-button, can be locked Running time motor 150 s / 90 Motor running time variable 35...150 s Adaption setting range manual Adaption setting range variable No action Adaption when switched on Adaption after pushing the gear disengagement button Override control, controllable via KNX MAX (maximum position) = 100% MIN (minimum position) = 0% ZS (intermediate position) = 50% Override control variable MAX = (MIN + 32%)...100% MIN = 0%...(MAX 32%) ZS = MIN...MAX Sound power level motor 35 db(a) Position indication Mechanically, pluggable Safety Protection class IEC/EN III Safety Extra-Low Voltage (SELV) Degree of protection IEC/EN IP54 EMC CE according to 2014/30/EU Certification IEC/EN IEC/EN 60730-1 and IEC/EN 60730-2-14 Mode of operation ype 1 Rated impulse voltage supply / control 0.8 kv Control pollution degree 3 Ambient temperature -30...50 C Non-operating temperature -40...80 C Ambient humidity 95% r.h., non-condensing Maintenance Maintenance-free Weight Weight 0.65 kg www.belimo.eu LM24A-KNX en-gb 2017-11-27 subject to changes 1

Safety notes! he device must not be used outside the specified field of application, especially not in aircraft or in any other airborne means of transport. Outdoor application: only possible in case that no (sea)water, snow, ice, insolation or aggressive gases interfere directly with the actuator and that is ensured that the ambient conditions remain at any time within the thresholds according to the data sheet. Only authorised specialists may carry out installation. All applicable legal or institutional installation regulations must be complied during installation. he device may only be opened at the manufacturer s site. It does not contain any parts that can be replaced or repaired by the user. Cables must not be removed from the device. o calculate the torque required, the specifications supplied by the damper manufacturers concerning the cross-section, the design, the installation site and the ventilation conditions must be observed. he device contains electrical and electronic components and must not be disposed of as household refuse. All locally valid regulations and requirements must be observed. Product features Mode of operation Converter for sensors Parameterisable actuators Simple direct mounting Manual override Adjustable angle of rotation High functional reliability Home position he actuator is equipped with an integrated interface for KNX (S-Mode) and can be connected with all KNX devices that have corresponding data points available. Connection option for a sensor (passive or active sensor or switching contact). In this way, the analogue sensor signal can be easily digitised and passed along to KNX. he factory settings cover the most common applications. As desired, individual parameters can be adapted for specific systems or servicing with a service tool (e.g. ZH EU) or the ES planning and commissioning tool. Simple direct mounting on the damper spindle with an universal spindle clamp, supplied with an anti-rotation device to prevent the actuator from rotating. Manual override with push-button possible (the gear is disengaged for as long as the button is pressed or remains locked). Adjustable angle of rotation with mechanical end stops. he actuator is overload protected, requires no limit switches and automatically stops when the end stop is reached. he first time the supply voltage is switched on, i.e. at the time of commissioning, the actuator carries out a synchronisation. he synchronisation is in the home position (0%). he actuator then moves into the position defined by the positioning signal. 0 Y = 0% ccw 1 Y = 0% cw Adaption and synchronisation An adaption can be triggered manually by pressing the Adaption button or with the PC-ool. Both mechanical end stops are detected during the adaption (entire setting range). Automatic synchronisation after pressing the gearbox disengagement button is configured. he synchronisation is in the home position (0%). he actuator then moves into the position defined by the positioning signal. A range of settings can be adapted using the PC-ool (see MF-P documentation) 2 LM24A-KNX en-gb 2017-11-27 subject to changes www.belimo.eu

Accessories Description Electrical accessories Connection cable 5 m, A+B: RJ12 6/6, o ZH/ZIP-USB-MP ZK1-GEN Connection cable 5 m, A: RJ11 6/4, B: Free wire end, o ZH/ZIP- ZK2-GEN USB-MP Auxiliary switch, add-on, 1 x SPD S1A Auxiliary switch, add-on, 2 x SPD S2A Feedback potentiometer 140 Ohm, add-on P140A Feedback potentiometer 140 Ohm, add-on, grey P140A GR Feedback potentiometer 200 Ohm, add-on P200A Feedback potentiometer 500 Ohm, add-on P500A Feedback potentiometer 500 Ohm, add-on, grey P500A GR Feedback potentiometer 1 kohm, add-on P1000A Feedback potentiometer 1 kohm, add-on, grey P1000A GR Feedback potentiometer 2.8 kohm, add-on P2800A Feedback potentiometer 2.8 kohm, add-on, grey P2800A GR Feedback potentiometer 5 kohm, add-on P5000A Feedback potentiometer 5 kohm, add-on, grey P5000A GR Feedback potentiometer 10 kohm, add-on P10000A Feedback potentiometer 10 kohm, add-on, grey P10000A GR Description ype Mechanical accessories Shaft extension 170 mm, for damper spindles Ø 6...20 mm AV6-20 Spindle clamp for LM..A, clamping range 6...20 mm K-ELA Spindle clamp for LM..A, clamping range 6...10 mm K-ELA10 Spindle clamp for LM..A, clamping range 6...13 mm K-ELA13 Spindle clamp for LM..A, clamping range 6...16 mm K-ELA16 Universal mounting bracket 180 mm Z-ARS180 Form fit insert 8x8 mm, for LM..A ZF8-LMA Form fit insert 10x10 mm, for LM..A ZF10-LMA Form fit insert 12x12 mm, for LM..A ZF12-LMA Form fit insert 8x8 mm, with angle of rotation limiter and position ZFRL8-LMA indication for LM..A Form fit insert 10x10 mm, with angle of rotation limiter and position ZFRL10-LMA indication for LM..A Form fit insert 12x12 mm, with angle of rotation limiter and position ZFRL12-LMA indication for LM..A Position indication for LM..A, NM..A, SM..A, GM..A Z-PI ype Description Service ools Service tool for parametrisable and communicative Belimo actuators / VAV controller and HVAC performance devices Belimo PC-ool, software for adjustments and diagnostics Adapter to Service ool ZH ype ZH EU MF-P MF-C www.belimo.eu LM24A-KNX en-gb 2017-11-27 subject to changes 3

Electrical installation! Notes Connection via safety isolating transformer. Wiring diagrams Connection without sensor + KNX 1 2 3 5 6 7 MF D+ D Signal assignment KNX: D+ = KNX+ (pink > red) D- = KNX- (grey > black) he connection to the KNX line should take place via WAGO connecting terminals 222/221. Connection with passive sensor, e.g. Pt1000, Ni1000, NC + KNX 1 2 3 5 6 7 Ni1000 28...+98 C 850...1600 Ω 2) MF D+ D P1000 35...+155 C 850...1600 Ω 2) NC 10...+160 C 1) 200 Ω...60 kω 2) 1) depending on type 2) Resolution 1 Ohm Connection with switching contact, e.g. pressure control device Connection with active sensor, e.g. 0...10 V @ 0...50 C + KNX + KNX p 1 2 3 5 6 7 MF D+ D Requirements switching contact: he switching contact must be able to accurately switch a current of 16 ma@24 V. 1 2 3 5 6 7 MF D+ D Possible voltage range: 0...32 V (resolution 30 mv) 4 LM24A-KNX en-gb 2017-11-27 subject to changes www.belimo.eu

KNX Group Objects Name ype Flags Data point type Values range C R W U ID DP_Name Format Unit Setpoint I C W 5.001 _Scaling 1 Byte % [0...100] Resolution 0.4% Override control I C W 20.* _Enum 1 Byte 0 = no override 1 = Open 2 = Closed 3 = Min 4 = Mid 5 = Max Reset I C W 1.015 _Reset 1 Bit 0 = no action 1 = reset Adaptation I C W 1.017 _Switch 1 Bit 0 = no action 1 = adapt estrun I C W 1.017 _Switch 1 Bit 0 = no action 1 = estrun Min I/O C R W 5.001 _Scaling 1 Byte % [0...100] Resolution 0.4% Max I/O C R W 5.001 _Scaling 1 Byte % [0...100] Resolution 0.4% Relative position O C R 5.001 _Scaling 1 Byte % [0...100] Resolution 0.4% Absolute position O C R 8.011 7.011 _Rotation_Angle _Length_mm mm [32,768...32,768] [0...65,535] Fault state O C R 1.002 _Bool 1 Bit 0 = no fault 1 = fault Overridden O C R 1.002 _Bool 1 Bit 0 = not active 1 = active Gear disengaged O C R 1.002 _Bool 1 Bit 0 = engaged 1 = disengaged Service information O C R 22.* _Bitset16 Bit 0 (1) Bit 1 (2) Bit 2 (4) Bit 3 (8) Bit 4 (16) Bit 5 (32) Bit 6 (64) Bit 7 (128) Bit 8 (256) Bit 9 (512) Sensor value O C R Resistance R 14.060 _Value_Resistance 4 Byte Ω emperature Relative humidity Air quality Voltage mv Voltage scaled Voltage scaled % Switch 9.001 9.007 9.008 9.020 7.* 5.001 1.001 _Value_emp _Value_Humidity _Value_AirQuality _Value_Voltage _Scaling _Switch 1 Byte C % rh ppm mv % [273...670 760] [0...670 760] [0...670 760] Excessive utilisation Mechanical travel increased Mechanical overload (Not used) (Not used) (Not used) (Not used) (Not used) [670 760...670 760] [0...65 535] [0...100] 0/1 Internal activity Bus watchdog triggered www.belimo.eu LM24A-KNX en-gb 2017-11-27 subject to changes 5

KNX Group Objects Setpoint Override control Reset Adaptation estrun Specification of actuator position in % between the parameterised Min and Max limits. Overriding the setpoint with defined override states. As data point type, 1 Byte (unsigned) is recommended (DP 20.*) Resetting the stored service messages (see KNX group object Service information). Perform the adaptation. An active adaptation is signaled in Bit 8 of Service information. Performance of a testrun that checks the entire operating range. An active testrun is signaled in Bit 8 of Service information. After completion, detected faults (mechanical overload, mechanical travel increased) are signaled in Service Information. Min Minimum Limit (position) in %. Caution: Changing the setting may result in malfunctions. Max Maximum Limit (position) in %. Caution: Changing the setting may result in malfunctions. Relative position Current actuator position in % Absolute position Fault state Overridden Gear disengaged Service information Sensor value Absolute position/stroke he data point type is to be selected depending on the type of movement: [ ] DP 8.011 [mm] DP 7.011 Collective fault based on Bit 0 Bit 7 of Service information Signaling of an active override control (OPEN/CLOSED) he device can be commanded via the KNX group object Override control or via the forced switching at the input Y/3. Only the override controls OPEN and CLOSED are signaled. Signaling an active gear disengagement Detailed information regarding device status As data point type, Bitset 16-Bit is recommended (DP 22.*) Status information Bit 0: Motor operation in relation to operating period too high Bit 1: Mechanical travel increased, e.g. defined end position exceeded Bit 2: Mechanical overload, i.e. defined end position not reached Bit 3 7: not used with this device type Bit 8: Internal activity (Synchronisation, Adaptation, estrun, ) Bit 9: Bus watchdog triggered Bit 0 Bit 7 are stored by the device and can be reset with the KNX group object Reset. As an alternative, the several bits can be read as collective fault state. he representation of the sensor value is dependent on the parameterization. See section "KNX parameters Sensor" 6 LM24A-KNX en-gb 2017-11-27 subject to changes www.belimo.eu

KNX Parameters Common Setpoint at bus failure Bus timeout [min] Increment for value update [%] Repetition time [s] A setpoint can be defined for cases of communication interruption. Values range: None (last setpoint) Open Closed Mid Factory setting: None (last setpoint) he monitoring of the communication takes place for the KNX group objects Setpoint and Override control. If none of the objects is written within the parameterised monitoring time, the bus fail position is set and signaled in the Service information (Bit 9). Monitoring time for the detection of a communication interruption. Values range: 1 120 min Factory setting: Actual values (position, volumetric flow) are transferred at the time of a value change insofar as these change by the parameterised difference value. If the relative value changes by the difference value, not only the relative actual value but also the absolute actual value are transferred. Values range: 0 100% Factory setting: 5% he transfer is deactivated with 0% in the event of a value change. Repetition time for all position and sensor actual values. Status objects are not transferred except with a change. Values range: 0 3600 s Factory setting: 0 = no periodic transmission Sensor Sensor type Increment for sensor value update Output (for sensor type "Active sensor") Polarity (for sensor type "Switch") he input Y/3 can be used to connect a sensor. he sensor value is digitised and made available as KNX communication object. Values range: No sensor Active sensor (0 32 V) Passive sensor (1 K / 20 K) emperature sensor (P1000 / Ni1000 / NG10K) Switch (0 / 1) Humidity sensor (0-10 V corresponds to 0 100%) Air quality sensor CO2 (0-10 V corresponds to 0 2000 ppm) Factory setting: No sensor A switching to Y/3 is treated as local override in the absence of sensor parameterization. he sensor value is transferred at the time of a value change insofar as this changes by the parameterised difference value. Values range: 0 65,535 Factory setting: 1 he transfer is deactivated with 0 in the event of a value change. Without value change, the sensor value is sent because of the repetition time. Only for "Active sensor" sensor type Values range: Sensor value mv (DP 9.020) Sensor value scaled (DP 7.xxx) Sensor value scaled % (DP 5.001) Factory setting: For "Sensor value mv", the measured voltage is made available without processing. In the case of the scaled sensor values, a linear transformation can be defined with two points. he polarity can be defined for the sensor type "Switch". Values range: Normal Inverted Factory setting: www.belimo.eu LM24A-KNX en-gb 2017-11-27 subject to changes 7

KNX Work Procedures Product database Setting physical address Firmware upgrade Resetting to KNX factory settings he product database for the import in ES4 or higher is available at the Belimo website www.belimo.eu (Download Center) he programming of the physical address takes place by ES and the programming button on the device. If the programming button is not accessible or accessible only with difficulty, then the address can be set using a point-to-point connection: "Overwrite Individual Address: 15.15.255" As a third possibility, the physical address can be programmed on the basis of the KNX series number (e.g. with Moov n Group). he KNX series number is placed on the device in two versions. One sticker can be removed for adhesion on the commissioning journal, for example. he KNX firmware of the device is updated automatically with the programming of the application program insofar as the product database has a more recent version. he first programming procedure takes somewhat longer in such cases (>1 min). If necessary, the device can be reset manually to the KNX factory settings (physical address, group address, KNX parameters). For the reset, the programming button on the device must be pressed down for at least 5 s during start-up. Operating controls and indicators 4 1 Adaption Prgm 5 0 1 2 Power 3 Status 1 Direction of rotation switch Switch over: Direction of rotation changes 2 Push-button and LED display green Off: No power supply or malfunction On: In operation Press button: riggers angle of rotation adaptation 3 Push-button and LED display yellow Off: On: Flashing: Press button: he actuator is ready Adaptation or synchronising process active or actuator in programming mode (KNX) Connection test (KNX) active In operation (>1 s): Switch the programming mode on and off (KNX) When starting (>5 s): Reset to factory setting (KNX) 4 Gear disengagement button Press button: Gear disengages, motor stops, manual override possible Release button: Gear engages, synchronisation starts, followed by standard mode 5 Service plug For connecting parameterisation and service tools Service Service ools connection he actuator can be parameterised by ZH EU via the service socket. For an extended parameterisation the PC tool can be connected. + AC 24 V DC 24 V 1 2 3 5 6 7 MP USB ZH EU i esc OK BELIMO PC-ool MF D+ D USB 8 LM24A-KNX en-gb 2017-11-27 subject to changes www.belimo.eu

Dimensions [mm] Dimensional drawings 66 47 116 61 22 116 41 Further documentation ool connections General notes for project planning www.belimo.eu LM24A-KNX en-gb 2017-11-27 subject to changes 9