Procontrol P14 89AS30R0100 Module and Application Description Analog Signal Multiplier

Similar documents
z488xx RF Switches/Multiplexers PXI

z8801 Local Oscillator PXI

z48831 / z :1/ 16:1 6 GHz Multiplexer Module

CP-T range Benefits and advantages

Analog signal converters CC-E I/I

Application Description 81EU01-E/R3210. Input Module for. Analog Signals 5-fold, 0/ ma. Input, Output, Signal Conditioning.

CP-T range Product group picture

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

SPAC265-8W. AC-DC power supply module. Features. Description. Applications

Three-phase monitoring relay CM-PFS

z47524 PXI Quad SPDT RF Changeover Switch Module

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Relion 605 series Self-Powered Feeder Protection REJ603 Product Guide

CP-E range Benefits and advantages

IB IL AI 2/SF. Function. INTERBUS Inline Terminal With Two Analog Input Channels. Data Sheet 5564A

Three-phase monitoring relays CM-PFE and CM-PFE.2

Electronic timer CT-SDS.22

9 Specifications. Specifications NOMINAL CHARACTERISTICS

Type CP-S, CP-C & CP-A Switch mode

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Three-phase monitoring relay CM-PVE

BIODEX MULTI- JOINT SYSTEM

EMC Test Report. Report Number: M030826

Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

SWT 3000 Teleprotection technical data siemens.com

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

R&S ZV-Z5x Calibration Units Specifications

CTE7000 Series Miniature pressure transmitters

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

Note1: Efficiency is tested at nominal input and full load at +25 C ambient Note2: Max Cap Load is tested at nominal input and full resisitive load

Three-phase monitoring relay CM-PBE

Modem 9600 baud 500FSD11 EDS500 series - FSK modems

High precision measurement system for current and voltage IHC-A/B-RM01/03

C series Product brief

Overcurrent Protection / 7SJ45

Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi PTS ii Portable Tourniquet System

Primary switch mode power supplies Product group picture

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-D 12/2.1

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

EMC standards. Presented by: Karim Loukil & Kaïs Siala

Features. Regulated Converter. RAC02-SE/277/W 2 Watt Single Output. RAC02- SE/277/W Wired. AC/DC Converter

Complex Solution for the Distribution Substation REF 542plus. Application and Setting Guide

Nursing Beds with Dewert drive system

Powered Traction Unit OPERATION MANUAL

Electromagnetic compatibility Guidance and manufacturer s declaration DIN EN :2007 (IEC :2007)

EMC test report AU01+E04

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT AC/DC Converter

M5800 Pressure Transducer with Rotatable Display

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT12- AC/DC Converter

English

General Safety/EMC and Electrical Information for i-limb ultra and i-limb digits

z475 Remote DC Power Supply Preliminary

Datasheet. messtechnik gmbh. Torque ranges from 0,5 to 1000 Nm. Features. Extra Features DRBK-A. Torque Transducer DRBK + DRBK-A

2015 / 9C EN-00 OSRAM GmbH Marcel-Breuer-Str München Germany. Radio and Telecommunications Terminal Equipment

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

Three-phase monitoring relays CM-PVS.81

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Series Rev 1.2 Dec. 2015

BROADBAND LINEAR AMPLIFIER Model P150

Test Specification for Type Approval

Electronic timer CT-SDD.22

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Liquid level monitoring relay CM-ENS.2x

Power supply CP-T 48/20.0 Primary switch mode power supply

CTE8000 Series OEM pressure transmitters for industrial media

Appendix A: Specifications

Electronic timer CT-TGD.22

PART NUMBERING SYSTEM

Power supply CP-T 24/10.0 Primary switch mode power supply

FlexRay Communications System. Physical Layer Common mode Choke EMC Evaluation Specification. Version 2.1

Features. Regulated Converter. RAC02-SE/277 2 Watt Single Output RAC02- SE/277. AC/DC Converter

Power supply CP-T 24/40.0 Primary switch mode power supply

HeRO duet

R&S ZV-Z5x Calibration Units Specifications

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Features. Switching Regulator. 0.5 Amp SIP3 Single Output R R DC/DC Converter

Pressure transmitter AKS 32 and AKS 33

PART NUMBERING SYSTEM

High power density 3W Converter in SIP7 case. 3kVDC and 4kVDC Isolation Options

STRATO 70W LED P DESCRIPTION KEY FEATURES APPLICATIONS AND BENEFITS MODEL CODING AND OUTPUT RATINGS TRC ELECTRONICS, INC

Single Turn Servo Mount Hall Effect Sensor in Size 05 (12.7 mm)

Packaging. nom. Output Voltage

Output Voltage* (nom.)(adjustable)

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Vector Network Analyzers ZVB

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Transcription:

Procontrol P14 89AS30R0100 Module and Application Description Analog Signal Multiplier

Procontrol P14 89AS30R0100 Analog Signal Multiplier

NOTICE TRADEMARKS This document contains information about one or more ABB products and may include a description of or a reference to one or more standards that may be generally relevant to the ABB products. The presence of any such description of a standard or reference to a standard is not a representation that all of the ABB products referenced in this document support all of the features of the described or referenced standard. In order to determine the specific features supported by a particular ABB product, the reader should consult the product specifications for the particular ABB product. ABB may have one or more patents or pending patent applications protecting the intellectual property in the ABB products described in this document. The information in this document is subject to change without notice and should not be construed as a commitment by ABB. ABB assumes no responsibility for any errors that may appear in this document. In no event shall ABB be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, nor shall ABB be liable for incidental or consequential damages arising from use of any software or hardware described in this document. This document and parts thereof must not be reproduced or copied without written permission from ABB, and the contents thereof must not be imparted to a third party nor used for any unauthorized purpose. The software or hardware described in this document is furnished under a license and may be used, copied, or disclosed only in accordance with the terms of such license. This product meets the requirements specified in EMC Directive 2014/30/EC. Procontrol is a registered trademark of ABB AG. All rights to copyrights, registered trademarks, and trademarks reside with their respective owners. Copyright 2016 ABB. All rights reserved. Release: July 2016 Document number: 2VAA008052

TABLE OF CONTENTS 1. APPLICATION... 6 2. FEATURES... 6 3. DESCRIPTION... 6 4. ANNUNCIATION FUNCTION... 6 5. FUNCTION DIAGRAM... 7 6. SETTINGS... 8 7. CONNNECTION DIAGRAM... 9 8. MODULE DESIGN... 10 9. SYSTEM DATA... 12 10. TECHNICAL DATA... 12 10.1 Power supply... 12 10.2 Process Interface... 12 10.2.1 Input values E1, E2, E3... 12 10.2.2 Transmitter supply US1, US2, US3... 12 10.2.3 Output values... 12 10.2.4 Transmission values... 13 10.3 Interference immunity (of process inputs and outputs)... 13 11. ORDERING DATA... 13 11. REVISION HISTORY... 14

Power supply APPLICATION 1. APPLICATION 2. FEATURES This module is used for converting and multiplying analog signals. The module is designed to process input signals of a level of 0... 20 ma or 4... 20 ma or 0... 10 V DC, the ranges being selected by means of jumpers. From the input signal, three output signals of 0... 20 ma or 4... 20 ma are formed which can be selected individually by using jumpers; also a signal of 0... 10 V is formed. 3. DESCRIPTION The inputs are electrically isolated from the rest of the circuitry. For supplying transmitters and other devices, a voltage of 15 V or 24 V DC is available for each input, also electrically isolated. The module contains three identical function units. The outputs are separated. 4. ANNUNCIATION FUNCTION A green light-emitting diode on the front panel indicates when the module is ready for operation. 6 2VAA008052

FUNCTION DIAGRAM Power supply 5. FUNCTION DIAGRAM USA USA USB Z Z Z US1 A11 Z1 E1 - A12 A13 E1 Function unit 1 A14 US2 Z2 A21 E2 - A22 A23 E2 Function unit 2 A24 US3 Z3 A31 E3 - A32 A33 E3 Function unit 3 A34 2VAA008052 7

Power supply SETTINGS 6. SETTINGS Type of input signals and output signals desired, and transmitter supply need to be selected by means of jumpers (JPxx). Inputs FE1 E1 FE2 E2 FE3 E3 JP10 JP20 JP30 JP11 JP21 JP31 JP12 JP22 JP32 I U I U I U 0 20 ma 4 20 ma 0 10 V Transmitter supply US1 US2 US3 JP19 JP29 JP39 24 V 15 V 15 V 24 V Outputs FE1 A11 FE2 A21 FE3 A31 JP13 JP23 JP33 JP14 JP24 JP34 4 ma 0 ma 4 ma 0 ma 0 20 ma 4 20 ma FE1 A12 FE2 A22 FE3 A32 JP15 JP25 JP33 JP16 JP26 JP36 4 ma 0 ma 4 ma 0 ma 0 20 ma 4 20 ma FE1 A13 FE2 A23 FE3 A33 JP17 JP27 JP37 JP18 JP28 JP38 4 ma 0 ma 4 ma 0 ma 0 20 ma 4 20 ma 8 2VAA008052

CONNNECTION DIAGRAM Power supply 7. CONNNECTION DIAGRAM Connection of externally supplied signal sources Supply Signal 0 (4)... 20 ma 0 10 V E - E - Source 89AS30 Connection of twin core transducers US1,2,3 S Z1,2,3 E MU E 89AS30 Connection of four-core transducers Possible only if their current consumption < 25 ma Supply - US1,2,3 Z1,2,3 Signal - E E MU 89AS30 2VAA008052 9

Power supply MODULE DESIGN 8. MODULE DESIGN Board size: 3 units, 1 division, 160 mm deep Connector: to DIN 41 612 / IEC 60603-2 1 x 48-pole edge connector, type F Weight: approx. 0.3 kg Contact assignments of connector X1 View of contact side: d b z 02 E3 E2 E1 04 E3- E2- E1-06 US3 US2 US1 08 Z3 Z2 Z1 10 12 A31 A21 A11 14 A31- A21- A11-16 A32 A22 A12 18 A32- A22- A12-20 A33 A23 A13 22 A33- A23- A13-24 A34 A24 A14 26 A34- A24- A14-28 30 Z Z Z 32 USA USA USB 10 2VAA008052

MODULE DESIGN Power supply Side view with jumper positions and view of module front 4 ma JP32 lnput Channel 3 4 ma 0 ma 4 ma 0 ma 4 ma 0 ma Channel 3 Output 1 Output 2 Output 3 JP39 4 ma JP22 lnput Channel 2 4 ma 0 ma 4 ma 0 ma 4 ma 0 ma Channel 2 Output 1 Output 2 Output 3 US U 4 ma JP12 lnput Channel 1 Output 1 4 ma 0 ma 4 ma 0 ma 4 ma 0 ma Channel 1 Output 2 Output 3 ABB 89AS30 2VAA008052 11

Power supply SYSTEM DATA 9. SYSTEM DATA Kind of influence Environmental Parameter Standard Characteristic/Value Operating conditions Climatic environment Ambient temperature IEC/EN 60068-2-2 0 C to 70 C, 16h Relative humidity IEC/EN 60068-2-78 5% to 95% RH Electromagnetic compatibility (EMC) Atmospheric pressure IEC/EN 60068-1 86 kpa to 106 kpa Electrostatic discharge immunity IEC/EN 61000-4-2 Class 3 Air discharge 8 kv Class 2 Contact discharge 4 kv Radiated, radio-frequency, IEC/EN 61000-4-3 80 MHz to 3000 MHz, electromagnetic field immunity Class 3 10 V/m, 80 % AM (1 khz) Electrical fast transient/burst IEC/EN 61000-4-4 5/50 ns immunity Class 3 2 kv - Supply lines for AC 120/230 V 2 kv (burst) 2 kv - Supply lines for DC 24 V - Signal lines (I/O and bus lines) Surge immunity - Supply lines for AC 120/230 V (burst) - Supply lines for DC 24 V - Signal lines (I/O and bus lines) Immunity to conducted disturbances, induced by radiofrequency fields Radiated emission IEC/EN 61000-4-5 Class 4/3 Class 1/1 Class 3 IEC/EN 61000-4-6 Class 3 CISPR16 / EN 55016 Class A 1.2/50 ns 4/2 kv 0.5/0.5 kv 2 kv 0.15 MHz to 80 MHz, 10 V, 80% AM (1 khz), Source impedance 150 Ω 30 MHz to 1000 MHz, Limit Class A, group 1 Conditions of storage and transport Climatic environment Ambient temperature IEC/EN 60068-2-2-40 C to 85 C, 16h Relative humidity IEC/EN 60068-2-30 5% to 100% RH 25 C to 40 C (6 cycles) Atmospheric pressure IEC/EN 60068-1 70 kpa to 106 kpa 10. TECHNICAL DATA 10.1 Power supply Supply voltage Current consumption 24 V DC approx. 110 ma output currents 10.2 Process Interface 10.2.1 Input values E1, E2, E3 Voltage input 0... 10 V (max. 30 V) Input resistance > 100 kohm Current input 0... 20 ma, 4... 20 ma Load resistance RB 55 Ohm 10.2.2 Transmitter supply US1, US2, US3 Selectable by means of jumpers 15 V DC, max. 25 ma 24 V DC, max. 25 ma 10.2.3 Output values Current outputs A11, A12, A13, A21, A22, A23, A31, A32, A33 Selectable by means of jumpers 0 20 ma 4 20 ma 12 2VAA008052

ORDERING DATA Interference immunity (of process inputs and outputs) Max. burden RB 1000 Ohm Voltage outputs A14, A24, A34 0... 10 V (max. 12 V) Max. current 5 ma 10.2.4 Transmission values Transmission error at input/output within the permissible temperature range and the permissible Supply voltage tolerances 0.3 % Signal delay < 1 msec 10.3 Interference immunity (of process inputs and outputs) The product is in conformity with the provisions of the following European Directive: 2014/30/EC Directive of the European Parliament and of the Council of 26 Februar 2014 on the harmonization of the laws of member States relating to electromagnetic compatibility (EMC Directive) Conformity to the stated Directive is assured through the application of the following harmonized standards: Environment: Industry EMC, Emission: EN 61000-6-4: 2007/A1:2011 EMC, Immunity: EN 61000-6-2: 2005/AC:2005 See 2VAA002182R0301_CE-Conformity-P14.pdf for detailed technical data. 11. ORDERING DATA Order no. for complete module: Type designation: 89AS30R0100 Order number: GKWN000317R0100 Technical data are subject to change without notice! 2VAA008052 13

Interference immunity (of process inputs and outputs) REVISION HISTORY 11. REVISION HISTORY Rev. Date / Initial 1.0 Replaces D KWL 6348 94 E 2016-06-29 CG 14 2VAA008052

ABB Inc. Power Generation Wickliffe, Ohio, USA E-Mail: powergeneration@us.abb.com www.abb.com/controlsystems ABB AG Power Generation Mannheim, Germany E-Mail: powergeneration@de.abb.com www.abb.com/controlsystems Document Number 2VAA008052 ABB Pte. Ltd. Power Generation Singapore E-Mail: powergeneration@sg.abb.com www.abb.com/controlsystems 15 MD_2VAA008052_89AS30R0100.docx