Effects of Mobile Phone Radiation onto Human Head with Variation of Holding Cheek and Tilt Positions

Similar documents
SAR REDUCTION IN SLOTTED PIFA FOR MOBILE HANDSETS USING RF SHIELD

ANALYSIS OF MATERIALS EFFECTS ON RADIO FRE- QUENCY ELECTROMAGNETIC FIELDS IN HUMAN HEAD. Malaysia, UKM Bangi, Selangor, Malaysia

MOBILE PHONE EM EXPOSURE STUDY ON INHOMOGENEOUS HUMAN MODELS CONSIDERING DIFFERENT HAND POSITIONS

INTERNATIONAL JOURNAL OF MICROWAVE AND OPTICAL TECHNOLOGY, VOL.11, NO.6, NOVEMBER 2016

REDUCTION OF PEAK SAR IN HUMAN HEAD FOR HANDSET APPLICATIONS WITH RESISTIVE SHEETS (R-CARDS)

Harmful Effects of Mobile Phone Tower Radiations on Muscle and Bone Tissues of Human Body at Frequencies 800, 900, 1800 and 2450 MHz

Far-Field Effects with Human Head Evaluation of EM Emission

Analysis of SAR in Human Blood, Bones and Muscles due to Mobile Waves at 900MHz,1800MHz and 2400MHz

Product Compliance Assessments of Low Power Radio Base Stations with Respect to Whole-Body Radiofrequency Exposure Limits

Mobile/Tablet Antenna Design and Analysis

SAR Analysis in a Spherical Inhomogeneous Human Head Model Exposed to Radiating Dipole Antenna for 500 MHz 3 GHz Using FDTD method

Numerical Assessment of Specific Absorption Rate in the Human Body Caused by NFC Devices

A Double-Negative Metamaterial-Inspired Mobile Wireless Antenna for Electromagnetic Absorption Reduction

Modified CPW Fed Monopole Antenna with Suitable Radiation Pattern for Mobile Handset

Multiband Compact Low SAR Mobile Hand Held Antenna

CHAPTER 2 SAR ANALYSIS

Numerical Modelling for Evaluation of Biological Effects Due to High Frequency Radiations in Indoor Environment

Area Network Applications] Notice: This document has been prepared to assist the IEEE P It is

Design of an implanted compact antenna for an artificial cardiac pacemaker system

Estimation of Whole-Body Average SAR in Human Body Exposed to a Base Station Antenna

Research Article SAR Reduction Using Integration of PIFA and AMC Structure for Pentaband Mobile Terminals

Investigation of Dosimetry in Four Human Head Models for Planar Monopole Antenna with a Coupling Feed for LTE/WWAN/ WLAN Internal Mobile Phone

HAZARDS OF NON-IONIZING RADIOFREQUENCY (RF) RADIATION

Investigation of the effect of metallic frames on 4G eyewear antennas

Interaction of an EM wave with the breast tissue in a microwave imaging technique using an ultra-wideband antenna.

Interaction Between GSM Handset Helical Antenna and User s Head: Theoretical Analysis and Experimental Results

Research Article A Novel Cellular Handset Design for an Enhanced Antenna Performance and a Reduced SAR in the Human Head

Human head influence on the performance of a planar inverted-f antenna for different positions

Health Issues. Introduction. Ionizing vs. Non-Ionizing Radiation. Health Issues 18.1

Research Article Analysis of Fractal Antenna for Ultra Wideband Application

Low SAR Planar Antenna for Multi Standard Cellular Phones

Design of Miniaturized Printed Antenna for Mobile Phones

Offset-fed UWB antenna with multi-slotted ground plane. Sun, YY; Islam, MT; Cheung, SW; Yuk, TI; Azim, R; Misran, N

CHAPTER 1 INTRODUCTON 1.1 EM INTERACTION WITH CONDUCTORS/DIELECTRICS

Effect of Tissue Boundaries on the Intra-Body Communication Channel at 2.38 GHz

Multi-band material loaded Low-SAR antenna for mobile handsets

Specific Absorption Rate (SAR) Overview Presented by Mark Jenkins and Vina Kerai. TÜV SÜD Product Service GmbH

Multi-Band Microstrip Antenna Design for Wireless Energy Harvesting

3. LITERATURE REVIEW. 3.1 The Planar Inverted-F Antenna.

Report Ref.:SZ S02. SAR Testing Report. Mobile phone radiation battery patch. Economic and Trade Limited. Issuer: Wu Xuewen

Analysis of SAR on flat phantom for different multi-antenna mobile terminals

Mechanism of Two Resonant Modes for Highly Resonant Wireless Power Transfer and Specific Absorption Rate

Measurement of Specific Absorption Rate of Monopole Patch Antenna on Human Arm

Electromagnetic Field Exposure Feature of a High Resonant Wireless Power Transfer System in Each Mode

ANNEX TO RESOLUTION No. 533, OF SEPTEMBER 10 th 2009.

COMMON REGULATORY OBJECTIVES FOR WIRELESS LOCAL AREA NETWORK (WLAN) EQUIPMENT PART 2 SPECIFIC ASPECTS OF WLAN EQUIPMENT

FDTD CHARACTERIZATION OF MEANDER LINE ANTENNAS FOR RF AND WIRELESS COMMUNICATIONS

High gain W-shaped microstrip patch antenna

Small Planar Antenna for WLAN Applications

CHARACTERISTICS, DOSIMETRY & MEASUREMENT OF EMF

Online Publication Date: 15 th May, 2012 Publisher: Asian Economic and Social Society

DESIGN OF SLOTTED RECTANGULAR PATCH ARRAY ANTENNA FOR BIOMEDICAL APPLICATIONS

User Interaction with Handset Antennas

II. COMPUTATIONAL METHODS AND MODELS

High frequency electomagnetic field irradiation. Andrea Contin

Determination of Transmission and Reflection Parameters by Analysis of Square Loop Metasurface

Handset Antennas and Influences Due to the Human Body

Technical Committee106 Methods for the assessment of electric, magnetic and electromagnetic fields associated with human exposure

ITU-D activities on EMF

EMF Exposure Analysis for a Compact Multi-Band 5G Antenna

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Study on the Evaluate Methods of Head and Hand Influence on Mobile Antenna Radiation Performance

CHARACTERISTICS, DOSIMETRY & MEASUREMENT OF EMF

Compact Wideband Microstrip Antenna for Universal 5GHz WLAN Applications

Impact of the size of the hearing aid on the mobile phone near fields Bonev, Ivan Bonev; Franek, Ondrej; Pedersen, Gert F.

A New Hyperthermia Scheme with a Cylindrical LHM Lens

RF AND MICROWAVE SAFETY PROGRAM

Rapid and simple design approach of micro-strip Butler matrix beam-forming network for wireless system

Research Article Dual-Band Operation of a Microstrip Patch Antenna on a Duroid 5870 Substrate for Ku- and K-Bands

GEISLAVARNIR RÍKISINS ICELANDIC RADIATION SAFETY AUTHORITY

MICROWAVE & RF RADIATION: (RFR Information - Technology Newsletter, Full Version)

Isolation Improvement of Dual Feed Patch Antenna by Assimilating Metasurface Ground

User Hand Influence on Properties of a Dual-Band PIFA Antenna

3D FINITE ELEMENT ANALYSIS FOR NON- ASYMMETRY STRUCTURE ANTENNA FOR MICROWAVE ABLATION THERAPY

Double Negative Left-Handed Metamaterials for Miniaturization of Rectangular Microstrip Antenna

Published in: Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

Microwave switchable frequency selective surface with high quality factor resonance and low polarization sensitivity

Microwave Cancer Therapy

Testing activities of NCA Type Approval Testing labs and key challenges. Kofi Ntim Yeboah-Kordieh National Communications Authority

November 3, Saw Sun Hock, Giorgi Bit-Babik, Ph.D., and Antonio Faraone, Ph.D. Motorola Solutions EME Research Lab, Plantation, Florida

SMART UWB ANTENNA FOR EARLY BREAST CANCER DETECTION

PO01275C Tabor East Neighborhood Meeting. Monday, April 20, :30 PM 8:30 PM

Bayesian Estimation of Tumours in Breasts Using Microwave Imaging

NEW IEEE C RF SAFETY STANDARD

DESIGN OF A MODIFIED W-SHAPED PATCH ANTENNA ON AL 2 O 3 CERAMIC MATERIAL SUBSTRATE FOR KU-BAND

ENHANCEMENT OF PRINTED DIPOLE ANTENNAS CHARACTERISTICS USING SEMI-EBG GROUND PLANE

RADIOFREQUENCY ELECTROMAGNETIC FIELDS

Estimation of Specific Absorption Rate Using Infrared Thermography for the Biocompatibility of Wearable Wireless Devices

ELECTROMAGNETIC COMPATIBILITY HANDBOOK 1. Chapter 8: Cable Modeling

Penta-Band Dielectric Loaded Folded Loop Antenna for Mobile Handset

Triple Band X Shape Microstrip Patch Antenna for Ku/K Band Applications

On the Evaluation of Biological Effects of Wearable Antennas on Contact with Dispersive Medium in Terms of SAR and Bio-Heat by Using FIT Technique

A Beam Switching Planar Yagi-patch Array for Automotive Applications

Design of a Dual Band Printed Dipole Antenna for WIFI Application

Harmful Effects on Human Body Tissues Due to Electromagnetic Waves of Radio Broadcasting at Frequency 1566 khz

Impact of the Coordinate System s Orientation

Radiofrequency (RF) Safety Overview Massachusetts Environmental Health Association

This is a preview - click here to buy the full publication. Exposure assessment methods for wireless power transfer systems

Efficient Metasurface Rectenna for Electromagnetic Wireless Power Transfer and Energy Harvesting

Department of Technology and Built Environment

Transcription:

Effects of Mobile Phone Radiation onto Human Head with Variation of Holding Cheek and Tilt Positions M. R. Iqbal-Faruque* 1, N. Aisyah-Husni 2, Md. Ikbal-Hossain 1, M. Tariqul-Islam 2 and N. Misran 2 1 Space Science Centre (ANGKASA) Research Centre Building Universiti Kebangsaan Malaysia (UKM) 436 UKM Bangi, Selangor, Malaysia *rashedgen@yahoo.com 2 Department of Electrical, Electronic and Systems Engineering Faculty of Engineering & Built Environment Building Universiti Kebangsaan Malaysia (UKM) 436 UKM, Bangi, Selangor, Malaysia ABSTRACT This paper analyzed the effects of electromagnetic (EM) radiation mobile phone on human head with different holding positions. The EM radiation is measured in terms of specific absorption rate (SAR). The human head exposed to global system for mobile communication (GSM) frequency bands. The radiation absorption analyzed through simulations by applying finite-difference time domain (FDTD) method using computer simulation technology (CST) microwave studio. The specific absorption rate (SAR) was measured for two common holding positions of mobile phone: Cheek and Tilt. In this tilt position, the mobile phone tilted for 15 and 3 from a person s head. SARs exhibited in much lower values as the mobile phone held in cheek position than that of tilt position. Helical antenna with substrate of RO36 found to be best tested substrate by resulted in lower SAR due to its lower conductivity properties than that of RO43. Keywords: different substrates, finite-difference time domain (FDTD) method, head model, mobile phone, specific absorption rate (SAR). 1. Introduction The application of mobile phone had extended to the worldwide community. This technology had been introduced as early as in the twenty first century and has been evolving since. Worldwide mobile subscribers increased significantly as the awareness of radiation effects of mobile phone towards human health widely spread across the globe [1]. Continuous researches had done to investigate the effect of electromagnetic (EM) radiation from mobile phone on human health [2-4]. This EM absorption by human is measured in terms of specific absorption rate, SAR [5-9]. SAR values show the radiated power from mobile phone absorbed by the human over a particular volume of body tissue corresponding to 1g or 1 g of body tissues [1], and it is measured in watt per kilogram (W/kg) [8]. A particular safe limit of SAR is chosen so that the maximum EM radiation exposure could be sustained without introducing biological changes onto the human health. These standards regulated by world authoritative bodies include International Commission on Non-Ionizing Radiation Protection, ICNIRP and Federal Communications Commission, FCC. According to the ICNIRP standard, the safe SAR limit is 2 W/kg for 1 g of body tissue [11, 12]. Several countries abide by this regulation are Australia, Japan, New Zealand and Brazil. Other countries such as Canada, South Korea, Bolivia and Taiwan followed the standard regulated by FCC. According to this standard, the limit of SAR is 1.6 W/kg over 1 g of body tissue [13]. SAR of mobile phone absorbed by humans is very dependent on the mobile network carrier, JournalofAppliedResearchandTechnology 871

EffectsofMobilePhoneRadiationontoHumanHeadwithVariationofHoldingCheekandTiltPositions, M.R.IqbalFaruqueetal./871876 characteristics of mobile phone and antenna, antenna positioning, and the radiated power from the mobile phone [14-16]. Other factor which influenced the EM absorption is the positioning of the mobile phone or the phantom itself [17-19]. The dielectric properties of human also effect SAR values [2]. Increase in conductivity and the decrease in permittivity of the human head cause increment of SAR [21]. Particular body tissue with higher water content contributes to higher SAR. Higher water content of body tissue implies that the body tissue has greater conductivity and is more susceptible to absorb EM waves. The magnitude of body tissue s conductivity and permittivity are dependent on the exposure frequency [11, 22]. The permittivity and conductivity of the tissues remain constant as long as the tissues exposed to a constant frequency exposure. Different exposure of operational frequency eventually altered the tissue s conductivity and permittivity accordingly. The effect of SAR majority depends on the antenna position on the mobile phone. A mobile phone with mounted antenna on top and hold in tilt position results in more absorption of EM radiation by the head [13]. This happens as the antenna is closer proximity to the head. Moreover, SAR values change with variation of holding position of mobile phone. Cheek and tilt are two prevalent ways of holding a mobile phone. Cheek position of mobile phone is parallel to the head of the user and closely located to the user s pinna. This position is the most frequently applied by the users [12]. In this paper, an investigation on SAR is presented with variation of holding cheek and tilt positions at 9 MHz and 18 MHz. The aim of this investigation is to find out the better mobile phone holding position, which will lead reduced EM absorption in the human head. The mobile phone is then tilted to 15 and 3 from the head in this investigation to take tilt position effects on SAR. 2. Method and Materials SAR calculations had applied the FDTD method using electromagnetic solver namely CST Microwave Studio. This FDTD method used for the solver had divided the head cells into smaller cell units. Each of the cells unit had been set to specific meshing properties before it was simulated. The mesh type was set to hexahedral. The mesh density control of line per wavelength of 8, mesh line ratio limit of 2 with total mesh cells of 6,211,119 were used. Homogeneous head dielectric properties were set in accordance the frequency exposure. SAR was calculated for cheek position and tilt of 15 and 3 of mobile phone from the head. For cheek position, the mobile phone was placed directly on the side of the head without any separation distance. This position was taken from the usual placement applied by most users. The human head model, known as specific anthropomorphic mannequin (SAM) [15], comes together with the helical antenna attached to a mobile phone. The homogeneous head model was comprised of two layers which were the inner and outer layer with specific dielectric properties at a particular frequency exposure. At other frequency exposure the head exhibited different dielectric properties. These properties were constant as long as the head was exposed to the same frequency exposure. SAR calculated through simulation applied the following equation [5]: E SAR 2 2 (1) Where, represents the tissue conductivity, E denotes on root mean square, rms electric field, is tissue density. The radiated power set for the simulation was.25 W. The radiated power of a mobile phone could be as high as 1 or 2 W. This occurs mainly due to the distance between the mobile station and the base station variation. Smaller distance of the mobile station to the base station amounts to lower radiated power of a mobile phone. The averaging method for SAR calculation was used in accordance with the IEEE C95.3 standard [25]. The helical antenna used resonated at 9 and 18 MHz. The substrates for the antenna were RO36 and RO43. The dielectric properties of the substrates are as in Table 1. 872 Vol.12,October214

EffectsofMobilePhoneRadiationontoHumanHeadwithVariationofHoldingCheekandTiltPositions, M.R.IqbalFaruqueetal./871876 Type of substrate Permittivity, r Conductivity, [S/m] RO36 (loss free) RO43 (loss free) 6.15.61 3.38.71 31 mm Table 1. Helical antenna dielectric properties. The dielectric properties of homogeneous human head [26] are shown in Table 2. Frequency [MHz] Permittivity, r Conductivity, [S/m] 9 41.5.97 18 4. 1.4 Table 2. Homogeneous human head dielectric properties. The mobile phone model used is a simple conducting box made of perfect electric conductor (PEC), with the dimensions of 18 4 1 mm3 (X Y Z). The model of the mobile phone is as shown in Figure 1. The length of the helical antenna is 31 mm and diameter of 5 mm. The helical antenna is shown as in Figure 2. Figure 2. Helical antenna used for SAR calculation. The holding position of a mobile phone was split into two techniques, which were cheek position and tilt position. A mobile phone held parallel to the user head without separation angle called cheek and the latter position with a user held the mobile phone tilted at an angle of 15 and 3 from a user head. SAR effect onto the user head was observed with these different placements of mobile phone from the head. The holding cheek and tilt positions of mobile phone presented are as shown in Figures 3 (a), (b) & (c). 1 mm Figure 3. Different position used for SAR measurement: a) Cheek, b) Tilt 15, and c) Tilt 3. 2. Results and Discussions 4 mm Figure 1. Handset antenna with mobile phone. Results are discussed for effects of SAR on a human head in cheek and tilt position for frequency exposures of 9 and 18 MHz. For tilt position, the SAR effect is observed in two conditions. The conditions are with tilt of 15 and 3. There are significant differences in SAR of both tilted positions. Variation of substrates of helical antenna also influences SAR of human head. JournalofAppliedResearchandTechnology 873

EffectsofMobilePhoneRadiationontoHumanHeadwithVariationofHoldingCheekandTiltPositions, M.R.IqbalFaruqueetal./871876 Figure 4 shows the SAR results of cheek position at 9 MHz. Helical antenna with substrate of RO43 exhibited the highest SAR in both volume of body tissue measured of 1 g and 1 g. This happened as the substrate of RO43 was higher in conductivity compared with the other substrate used. Substrate with higher conductivity leads higher surface current and hence higher EM absorption in the head. The variation of SARs was from 1.88% to 1.564 % at its minimum and maximum values. These differences were still small and did not alter much the SAR distribution of the human head. The SAR effect of cheek position at 18 MHz is as in Figure 5. Value of SAR (W/kg) Value of SAR (W/kg) 5 4 3 2 1 Figure 4. SAR of cheek position with two different substrates at 9 MHz. 5 4 3 2 1 RO36 RO36 RO43 RO43 Figure 5. SAR of cheek position with two different substrates at 18 MHz. SAR effect onto human head with mobile phone in cheek position which exposed to 18 MHz showed in Figure 5. The highest SAR was 3.46186 W/kg for SAR of 1 g of body tissue with helical antenna with substrate of RO43 (loss free). The helical antenna with substrate of RO36 resulted in the lowest SAR of 2.1271 W/kg at SAR of 1 g of body tissue. The SARs resulted from helical antenna with substrate of RO43 were always higher than that the other substrate due to its conductivity property. The conductivity of its substrate was higher and thus influenced to increase the EM absorption towards human head and caused higher SARs. SARs of human head with mobile phone placed in different tilted positions and exposed to 9 MHz as showed in Figure 6. ValueofSAR(W/kg) 15 12 9 6 3 RO36 Tilt15 o RO43 RO36 Tilt3 o RO43 Figure 6. Compared values of different tilt position of SAR at 9 MHz. From Figure 6, it can be seen that the SARs of 15 tilts were always higher than the SARs of mobile phone with 3 tilt from the human head. In this tilted position of 15, the human head more readily absorbed electromagnetic waves emitted from the mobile phone due to the placement of the helical antenna. The electromagnetic radiation was absorbed mostly toward the skin at the closest area of the head from the mobile phone was held to. The highest absorption of radiation is at the head part; mainly over the area of the frontal lobe and side of the brain which is the usual placement of the mobile phone among the users. Since the brain is one of the conductive parts of the body, the radiation was more susceptible to be absorbed in this region. When the human head experienced higher frequency exposure from a mobile phone which tilted exhibited SARs differently. Figure 7 showed the SAR of tilt position at 18 MHz. 874 Vol.12,October214

EffectsofMobilePhoneRadiationontoHumanHeadwithVariationofHoldingCheekandTiltPositions, M.R.IqbalFaruqueetal./871876 It showed that there was a significant drop as the mobile phone tilted 3 from the human head. This was due to the helical antenna being situated near to the radiation absorption susceptible area of the brain. This is showed in Figures 3 (b) and 3 (c), as the mobile tilted 15, the helical antenna is nearer to the side of the human head compared to the mobile phone tilted at 3. SARs of 1 g were all higher than the SARs of 1 g. For smaller volumes of body tissue, the resolutions of calculating SAR values are much better. The higher volume of body tissue as 1 g tend to hinder the whole SAR value of the tissues [23, 24]. At low frequency, the SAR value is high due to penetration of the microwave fields towards a subject at those frequencies. ValueofSAR(W/kg) 2 15 1 5 RO36 3. Conclusion Tilt15 o RO43 RO36 Tilt3 o RO43 Figure 7. Compared values of different tilt positions of SAR at 18 MHz. From the work, SARs at the human head were much lower as the mobile phone was held in cheek position. In this position, the helical antenna mounted onto the mobile phone was situated far from the head. Tilt positions of mobile phone produce higher SAR than that of cheek position due to the reduced distance between helical antenna and human head. Although the body of the mobile phone was directly next to the head, the antenna extrudes far from the head. It is essential to keep human head as distant from the antenna as possible, since it is the source of radiation emission. The antenna substrate material effects SAR significantly. Substrate with lower conductivity leads lower induced surface current and lower radiation towards human head. References [1] WHO 211 Research Agenda for Radio Frequency Fields, World Health Organization. (211). Available from:http://edition.cnn.com/211/health/5/31/who.cel.p hones/index.html [2] M. R. I. Faruque et al., Design analysis of new metamaterial for EM absorption reduction, Progress In Electromagnetics Research, PIER. Vol. 124, pp. 119-135, 212. [3] M. T. Islam et al., Design analysis of ferrite sheet attachment for SAR reduction in human head, Progress In Electromagnetics Research, PIER. Vol. 98, pp. 191-25, 29. [4].O. Fujiwara and J. Wang, Comparison and Evaluation of Electromagnetic Absorption Characteristics in Realistic Children for 9 MHz Mobile Telephones, IEEE Trans. Microw. Theory Tech., vol. 51, no. 3, pp. 966-971, 23. [5] M. R. I. Faruque et al., Electromagnetic (EM) absorption reduction in a muscle cube with metamaterial attachment, Medical Engineering & Physics, vol. 33, no. 5, pp. 646-652, 211. [6] Standard for Safety Levels with Respect to Human Exposure to Radiofrequency Electromagnetic Fields 3 khz to 3 GHz, IEEE Standards Coordinating Committee 28.4, 26. [7] Human Exposure to Radio Frequency Fields from Hand-held and body-mounted Wireless Communication Devices- Human Models, Instrumentation, and Procedures Part 1 Procedure to Determine the Specific Absorption Rate (SAR) for Hand-held Devices Used in Close Proximity to the Ear 3 MHz to 3 GHz, IEC 6229-1, 26. [8] M. R. I. Faruque et al., Effect of human head shapes for mobile phone exposure on electromagnetic absorption, Informacije MIDEM, vol. 4, no. 3, pp. 232-237, 21. [9] M. I. Hossain et al., Application of Auxiliary Antenna Elements for SAR Reduction in the Human Head, Advanced Materials Research, vol. 974, pp. 288 292, 214. [1] A. H. Kusuma et al., A new low SAR antenna structure for wireless handset applications, Progress in Electromagnetics Research, vol. 112, pp. 23-4, 211. [11] J. Keshvari et al., The effect of increase in dielectric values on specific absorption rate (SAR) in eye and head tissues following 9, 18 and 245 MHz radio JournalofAppliedResearchandTechnology 875

EffectsofMobilePhoneRadiationontoHumanHeadwithVariationofHoldingCheekandTiltPositions, M.R.IqbalFaruqueetal./871876 frequency (RF) exposure, Physics in Medical and Biology, vol. 51, no. 6 pp. 1463-1477, 26. [12] T. Takebayashi et al., Mobile phone use exposure to radio frequency electromagnetic field and brain tumor: A Case-control Study, Brit. J. Cancer, vol. 98, no. 3, pp. 652-659, 28. [13] N. Varsier et al., Categorization of mobile phone for exposure assessment in epidemiological studies on mobile phone use and brain cancer risk, IEEE Trans. Microw. Theory Tech., vol. 56, no. 1, pp. 2377-2384, 28. [14] J. Wiart et al., Analysis of the influence of the power control and discontinuous transmission on RF exposure with GSM mobile phone, IEEE Trans. Electromagn. Compat., vol. 42, no. 4, pp. 376-385, 2. [15] M. R. I. Faruque et al., Design of metamaterial attachment for SAR reduction in human head, Applied Computational Electromagnetic Society Journal, vol. 25, no. 12, pp. 197-117, 21. [16] M. R. I. Faruque et Al., Effects of dielectric values & substrate materials on electromagnetic (EM) absorption in human head, Frequenz Journal, vol. 66, no. 3-4, pp. 79-83, 212. [22] Michtchenko, Numerical and experimental analysis in the manipulation of the mechanical properties for enhancing the mechanical resistance of a material, Journal of Applied Research and Technology, vol. 9, no. 2, pp. 156-172, 211. [23] K. J. Rothman et al., Assessment of Cellular Telephone and Other Radio Frequency Exposure for Epidemiology Research, Epidemiology, vol. 7, pp. 291-298, 1996. [24] M. R. I. Faruque et al., Analysis of SAR levels in human head tissues for four types of antennas with portable telephones, Australian Journal of Basic and Applied Sciences, vol. 5, no. 3, pp. 96-17, 211. [25] IEEE," C95.3-22 IEEE Recommended Practice for Measurements and Computations of Radio Frequency Electromagnetic Fields With Respect to Human Exposure to Such Fields, 1 khz 3 GHz," IEEE vol. New York, 22. IEEE, New York, 22. [26] Ebrahimi-Ganjeh et al., Interaction of dual band helical and PIFA handset antennas with human head and hand, Progress In Electromagnetics Research, Vol. 77, 225 242, 27. [17] B. Beard et al., Comparisons of Computed Mobile Phone Induced SAR in the SAM Phantom to that in Anatomically Correct Models of the Human Head, IEEE Trans. Electromagn. Compat., vol. 48, no. 2, pp. 397-47, 26. [18] J. Mar et al., A three-dimensional position architecture using digital TDE receiver and cylindrical array antenna, Journal of Applied Research and Technology, vol. 11, no. 2, pp. 175-182, 213. [19].O. Sharifi-Tehrani, Design, simulation and implementation of an active sound-noise cancellation system for use in a cockpit intercommunication system, Journal of Applied Research and Technology, vol. 1, no. 5, pp. 731-736, 212. [2] J. Z. Bao et al., Complex dielectric measurements and analysis of brain tissues in the radio and microwave frequencies, IEEE Trans. Microw. Theory Tech., vol. 45, no. 1, pp. 173-1741, 1997. [21] P. Gajšek et al., Parametric dependence of SAR on permittivity values in a man model, IEEE Transactions on Biomedical Engineering, vol. 48, no. 1, pp. 1169-1177, 21. 876 Vol.12,October214