Zinc Cable & Conduit Connectors For Armored Cable, Flexible Metal Conduit & Metal Clad Cable

Similar documents
NEER Zinc Cable and Conduit Connectors For Flexible Metal Conduit

tings fi t fl ex/mc/ac

RACO Commercial Fittings

Conduit End Bells...EA1 Hex Reducing Bushings...EA2 Conduit Hubs...EA3-EA4. Split Couplings...EA5 Three Piece Couplings...EA6 Conduit Nipples...

Ground Clamps Cable Tray

RACO Commercial Fittings


4.3 Section CONDUIT INSTALLATION ACCESSORIES. Thinking of the environment. Fixing accessories Coupling accessories

BELL. RACO, TayMac and BELL offer a full line of electrical products that are ideally suited to help you complete your next solar project

Setting Standards Connectors M 16

Specialist liquid tight products LTPSS system stainless steel pvc coated liquid tight LTPPU system galvanised steel, polyurethane coated liquid tight

Liquid Tight Conduit Connector With Internal Threads, Female Liquid Tight Conduit Fittings ( YCM )

Delikon Stainless Steel Liquidtight Connectors offer corrosion resistance and the strength of stainless steel for the highest levels of endurance.

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8" to 1/2" NPT. Proportional Valves. Features.

Mast and Antennas for Field Day & Emergencies

05 Pg A75-90.qxp 6/9/2008 9:36 AM Page A75 RACO Floor Boxes

PIPE/CONDUIT SUPPORTS

Cabtite Cable entry system. Cable entries and Cabtite

Iberville. Commercial Grade Fittings EMT CI5410 / CI5432 CI5410IT / CI5432IT CI5404 / CI5408 CI5404IT / CI5408IT CI5004 (-IT) / CI5008 (-IT)

GLOSSARY OF ELECTRICAL INDUSTRY TERMS

Thru Wall Floor Seals For New Installation

Round/Octagon Boxes and Accessories

Jake Leahy s Electrical Code Connection. A look at Grounding and Bonding of Electrical Services Article Florida Building Code 5 th Edition

International Tube & Conduit Company Ltd. BRITISH STANDARD STEEL CONDUITS & FITTINGS

General Information...SA1-SA4

Techline Flat Cross Splice. Techline Yoke Clamps* Techline Gang Clamps* TECHLINE. *Yoke Clamps Are Available To Fit Any Width.

DeviceNet Series. Cables Cordset Accessories Receptacles Receptacle Accessories Junction Blocks

Precision Thermistor Sensors

Glenair s Series 80 ASAP Cordsets for High-Speed Ethernet, USB and Firewire Applications

ELECTRICAL PANEL SYSTEM

Flexicon Flexible Conduit, Glands and Clamps

A. Product Description: Stranded conductor insulated wire.

Beam and Purlin Clamps Beam Clamps

P3-19 Series Connectors For Entertainment Lighting

E.M.T. Set-Screw Connectors. Technical Specifications

ELECTRIC GROUNDING AND WIRING REQUIREMENTS BOOTHS-METAL

Steel City Comparison & Strategy. vs. T&B Liquidtight Fittings. Andrea Briggs. Associate Product Manager - Conduit & Fittings FOR INTERNAL USE ONLY

EuroMag Series PCB Mount Terminal Blocks. EM3123 Series Euro-Mag Terminal Blocks 3.50 Centers; Modular. Part Numbering System

content Introduction Some good reasons to use SMARTr products Reducers, Plugs Conduit Reducer Stopping Plug

INTERMEDIATE METAL CONDUIT

CONTINUING EDUC ATION

STANDARD RTD's INDEX

Floor Boxes. Flush Service Floor Boxes

Ford Water Meter Couplings & Accessories

Article 250 Grounding & Bonding

Floor Boxes. Concealed Service Floor Boxes. Engineering Data 663 Series. Faces Plates for 663 Floor Box. 663 Series Floor Box

Parts Catalog. S-Series Slicer Smart Manual SG13. Model:

Assembly Instructions

commercial and industrial fittings: cast DEVICE BOXES Applications Illustrated Features

Clamp Pair. Bore Diameter (mm) Clamp Material PP = Polypropylene PA = Polyamide PE = Polyethylene AL = Aluminum

Holemaking. Contents MADE FOR THE TRADE!

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

M2 Antenna Systems, Inc. Model No: 7&10-30LP8

C-L-X ARMOR REMOVAL PROCEDURES

Outline. Grounding Washer, Electrical Equipment Bond (WEEB) Acme Cable Clips Acme Conduit Entry (ACE) Questions

Concealed Thru-Roof Assemblies

SW 16mm. SW 15mm. SW 19mm

The MUELLER method of making a main to service connection using the MUELLER E-5 Small Drilling Machine. Hand or power. kpa/34.

PARTS LIST MS 2892-D

B-Too Drilling and Tapping Machine Instruction and Maintenance Manual

MIST SANITARY SERIES TM

Amphenol. Circular. Connectors C 16-1 / C Circular Connectors. Amphenol-Tuchel Electronics

The MUELLER method of making a main to service connection using the MUELLER E-5 Small Drilling Machine. The main is drilled out under pressure.

American Electrical Institute

Holemaking. FEATURED Products. Slug-Splitter SC (Self-Centering) Knockout Punches NEW. Bi-Metal Hole Saws with Stops. NEW Quick Connect Extensions

General Installation Instructions

B32157 UNDERCARRIAGE KIT. Jeep Cherokee Jeep Wagoneer Jeep Comanche Parts List and Installation Instructions CAUTION

M2 Antenna Systems, Inc. Model No: 20M5LD

CONDUIT, FITTINGS & SADDLES

Profibus-PA. Profibus-PA. Process Automation. Over-Molded Cables Receptacles Field Wireables Accessories. UL File #: E

SAC-5P- 1,5-PUR/M12FS SH

DETAIL SPECIFICATION SHEET FITTINGS - INSTALLATION OF FLARED TUBE, STRAIGHT, THREADED CONNECTORS, DESIGN STANDARD FOR

Available in high-capacity. and assembled by hand for smooth operation. Durable chrome-plated finish. Heat-treated for long life.

Hose Accessories. "Air King" 4 - Lug Quick-Acting Couplings. Hose End. Female N.P.T. End

Cable Hanging Instruction Manual

EP METAL TYPE - SOLDER ISO ASSEMBLY OF EP MALE ISO ASSEMBLY OF EP FEMALE

Kerkau Manufacturing. B16.5 Flange Book

Fiber Splice Box (FSB-D) Installation Instructions

Wrenches. Wrenches. F o r P. r o f e. s s i o. n a l s. .. S i. n c e 1

EN2 SERIES SEALED CONNECTORS

TRANSMITTAL LETTER. As Builts Change Order Contract Copy of Letter Insurance. For approval Approved as submitted Resubmit copies for approval

SB 50 Connectors - up to 120 amps

The V2100 Series Steel Raceway provides wiring

NEW. Automation Technology 768 series

M2 Antenna Systems, Inc. Model No: 10-30LP8

2. CONDUCTORS. 2.1 Strand Types. 2.2 Coatings Tensile Strength of Copper Wire Copper Strand Properties. 2.5 Aluminum Strand Properties

NELSON STUD WELDING ACCESSORY SPECIFICATION: Stud Weld Gun Imperial Dimension Chucks

Spring Steel Fasteners

Adhesive Air Terminal Bases. Universal Surface Bases. Offset Parapet Air Terminal Bases. Section 3.2. Air Terminals & Air Terminal Bases

Steel Raceways BASE SECTIONS. SnapMark SMS3000 Series FITTINGS, CONNECTORS & BOXES RIGID COUPLING COUPLING BLANK END FITTING ENTRANCE END

PF/PFQ. High Amperage plug and receptacle. Main Advantages

N Male Right Angle Connector Clamp/Solder Attachment For 1/2 inch Annular, 1/2 inch Flexible, PE-1/2FAC. Cable Attachment Method (Shield/Contact)

Waterpipe Ground Clamps. 1/2 in., 3/4 in., 1 or rebar /4 in., 1-1/2 in. or 2 in. 4 #6, #4, #2 AWG

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit

Precision Junction Boxes

ST90 SADDLE STITCHER TP10564 MISSING STITCH INSTALLATION MANUAL

Assembly Instructions: Bencher Skylark

Superstrut. Metal Framing. Beam Clamps. Design Loads. Finishes and Special Materials

M2 Antenna Systems, Inc. Model No: 10-30LP8

Cat. No. A1200 A1200-S A1200-KO. Finishes & Materials. E142-1/4x100EG 1/4 x 1 A100-5/16EGC A100-3/8EGC. Standard Finish: Electrogalvanized

Transcription:

For Armored Cable, Flexible Metal Conduit & Metal Clad Cable Type AC 90 2-Screw Clamp To make a 90 termination of conduit or cable to a knockout or unthreaded slip hole in a dry location box or enclosure. Male hub threads NPS All center stopped Furnished with locknut Available with insulated throat Combination head screws on AC(I)-90 through AC(I)-96 Body and locknut Zinc Plated Steel Cover and screws Type AC-90 Type I, Class I, Style D, Kind C AC-90 and AC-95 listed for use with 3/8 regular wall steel or aluminum flexible conduit. AC-96 listed for use with 3/4 regular wall steel or aluminum flexible conduit and reduced wall steel or aluminum flexible conduit. AC-90, ACI-90, AC-95, and ACI-95 are listed for use with 14-2 AWG through 10-3 AWG steel or aluminum armored cable and AC-95 is listed for use with 8-2 AWG and 8-3 AWG steel or aluminum armored cable. Insulated Throat Trade Size Catalog Catalog Dimensions in Inches (inches) Number Number A B C D 3/8* AC-90 ACI-90 1.12 0.37 1.74 0.43-0.72 1/2 AC-95 ACI-95 1.51 0.40 2.11 0.64-1.03 3/4 AC-96 ACI-96 1.65 0.44 2.40 0.76-1.15 1 AC-97 2.33 0.54 2.87 1.09-1.73 1-1/4 AC-98 2.75 0.64 4.00 1.34-1.97 1-1/2 AC-985 3.75 0.75 6.00 1.65-2.61 2 AC-99 4.00 0.74 6.00 1.54-2.54 2-1/2 AC-250-D 6.12 0.87 7.19 2.45-2.98 3 AC-300-D 6.70 1.03 7.87 2.93-3.45 3-1/2 AC-350-D 7.50 1.03 9.40 3.28-3.95 4 AC-400-D 8.70 1.03 10.20 3.68-4.42 AC-90 and ACI-90 are listed for use with 14-2 AWG through 10-3 AWG interlocking steel or aluminum metal-clad cable. PAGE 12

For Armored Cable, Flexible Metal Conduit & Metal Clad Cable Type DC-5500 Duplex Single Screw, Clamp To make a termination of conduit or cable to a knockout or unthreaded slip hole in a dry location box or enclosure. 3/8* DC-5500 1.37 0.38 0.68 Furnished with locknut Male hub NPS Combination head screw Type 1, Class 1, Style B, Kind D Type DC-5500 DC-5500 is listed for use with 14-2 AWG through 12-2 AWG steel or aluminum armored cable. DC-5500 is listed for use with 3/8 steel or aluminum flexible metal conduit. DC-5500 is listed for use with 14-2 AWG (nominal O.D..425 ) through 10-3 AWG (nominal O.D..560 ) aluminum interlocking metal-clad cable and 14-2 AWG (nominal O.D..430 ) through 10-3 AWG (nominal O.D..565 ) steel interlocking metal-clad cable, 14-2 AWG (nominal O.D..380 ) through 10-3 AWG (nominal O.D..565 ) continuous corrugated round aluminum metal clad cable, and 14-2 AWG (nominal.250 x.365 ) through 12-3 (nominal.280 x.525 ) continuous corrugated rectangular aluminum metal-clad cable. Type C-510 2-Screw Connectors To terminate conduit or cable to a 1/2 knockout in a dry box or enclosure. 3/8* C-510 0.37 0.82 0.94 End stopped Male hub threads NPS Provided with locknut Combination head screw Type 1, Class 1, Style B, Kind D. Type C-510 C-510 is listed for use with 3/8 regular wall steel or aluminum flexible conduit. C-510 is listed for use with 14-2 AWG through 10-2 AWG steel or aluminum armored cable. C-510 is listed for use with 14-2 AWG (nominal O.D..406 through 10-3 AWG (nominal O.D..551 ) aluminum interlocking metal clad cable and 14-2 AWG (nominal O.D..450 ) through 10-3 AWG (nominal O.D..600 ) steel interlocking metal-clad cable, 14-2 AWG (nominal O.D..388 ) through 10-3 AWG (nominal O.D..500 ) continuous corrugated round aluminum metal-clad cable, and 14-2 AWG (nominal.250 x.365 ) through 12-3 (nominal.280 x.490 continuous corrugated rectangular aluminum metal-clad cable. PAGE 13

For Armored Cable, Flexible Metal Conduit & Metal Clad Cable Type FC Set Screw To terminate regular wall steel or aluminum flexible conduit to a 1/2 knockout in a dry location box or enclosure. 1/2 FC-5501 1.38 0.38 1.26,. Type 1, Class 1, Style A, Kind E. Type FC-5501 Type GC Screw-in Screw-in type connectors for flexible metal conduit. Federal Spec: W-F-406D, Type 1, Class 1, Style A, Kind A. Insulated Throat Trade Size Catalog Catalog Dimensions in Inches (inches) Number Number A B C 3/8* GC-38 GCI-38 1.28 0.45 1.12 1/2 GC-50 GCI-50 1.37 0.72 1.14 3/4 GC-75 GCI-75 1.47 0.92 1.39 1 GC-100 1.94 1.12 1.71 1-1/4 GC-125 2.12 1.41 2.12 1-1/2 GC-150 2.31 1.70 2.37 2 GC-200 2.59 2.18 3.00 Type GC-38 Cat. No. GC-38 and GC-50 are listed for use with regular wall steel or aluminum flexible conduit. The GC-75 is listed for use with regular wall steel or aluminum and reduced wall steel or aluminum flexible conduit. GC-100 through GC-200 are listed for use with regular wall steel or aluminum flexible conduit. PAGE 14

For Armored Cable & Flexible Metal Conduit Type SC Straight Squeeze These squeeze type connectors are used to terminate conduit or cable to a knockout or unthreaded slip hole in a dry location box or enclosure. Male hub threads NPS Available with insulated throat Furnished with locknut Combination head screws on SC-38, SC(I)-50 and SC(I)-75. Type 1, Class 1, Style A, Kind F. Type SC-38 Insulated Throat Inside Diameter Range Trade Size Catalog Catalog Dimensions in Inches (inches) Number Number A B C D (max) D (min) 3/8* SC-38 1.04 0.52 1.11 0.65 0.53 1/2 SC-50 SCI-50 1.43 0.42 1.43 1.00 0.88 3/4 SC-75 SCI-75 1.55 0.44 1.57 1.16 0.94 1 SC-100 1.75 0.55 1.97 1.38 1.25 1-1/4 SC-125 1.92 0.61 2.23 1.63 1.50 1-1/2 SC-150 2.09 0.71 2.52 2.00 1.75 2 SC-200 2.35 0.73 3.06 2.50 2.22 2-1/2 SC-250 2.89 0.89 3.86 3.06 2.75 SC-38 and SC-50 listed for use with 3/8 regular wall steel flexible conduit. SC-75 listed for use with 3/4 inch regular wall steel or aluminum flexible conduit and reduced wall steel or aluminum flexible conduit. 3 SC-300 3.89 1.00 4.42 3.56 3.22 3-1/2 SC-350 4.24 0.99 4.88 4.06 3.72 4 SC-400 4.55 1.00 5.46 4.50 4.16 PAGE 15

Zinc Cable & Conduit Couplings For Armored Cable & Flexible Metal Conduit Type EFC Combination Coupling A combination coupling to provide a transition from EMT to flexible metallic conduit. (inches) Number A B 1/2 to 3/8 EFC-50 1.16 1.05 1/2 to 1/2 EFC-75 1.64 1.54 3/4 to 3/4 EFC-100 1.97 1.54 Type 4, Class 6 EFC-75 and 100 EFC-75 EFC-50 Type EGC Combination Coupling Screw-in/ Compression (inches) Number A B 1/2 to 1/2 EGC-50 1.66 0.71 3/4 to 3/4 EGC-75 1.68 0.92 A combination coupling to pro vide a transition from EMT to flexible metallic conduit. Type 4, Class 6 Type EGC-50 PAGE 16

Zinc Cable Connectors Type TA-38 Saddle Clamp To terminate Armored Cable, Metal-Clad Cable or Nonmetallic Sheathed Cable in a 1/2 knockout in a dry location box or enclosure. 3/8* TA-38 0.36 0.90 0.65 Type 1, Class 1, Style A, Kind D Type TA-38 TA-38 is listed for use with 14-2 AWG (nominal O.D. 0.465 ) to 10-3 AWG (nominal O.D. 0.500 ) steel armored cable (AC); 14-2 AWG (nominal O.D. 0.480 ) to 10-3 AWG (nominal O.D. 0.585 ) aluminum armored cable (AC): 0.475 to 0.600 O.D. steel interlocking metal-clad cable (MCI); 0.468 to 0.610 O.D. aluminum interlocking metalclad cable (MCI); 0.452 to 0.584 O.D. aluminum interlocking metal-clad cable, grounding type (MCI-A); 12-2 AWG to 10-3 AWG nonmetallic sheathed cable. Type C-550 Set-Screw To terminate Armored Cable or Metal-Clad Cable in a 1/2 knockout in a dry location box or enclosure. 3/8* C-550 0.78 0.36 0.93 Type 1, Class 1, Style A, Kind E Type C-550 C-550 is listed for use with 14-2 AWG (nominal O.D. 0.460 ) to 10-2 AWG (nominal O.D. 0.598 ) steel armored cable (AC) and 14-2 AWG (nominal O.D. 0.469 ) to 10-3 AWG (nominal O.D. 0.600 ) steel interlocking metal-clad cable (MCI). Effective July, 2008 Copyright 2008 PAGE 17

Flexible Cord Connectors Type SRA Strain Relief Cord Connectors To seal, provide strain relief and to terminate portable or flexible cords to threaded hubs of a water-tight or liquid-tight location box or enclosure. Types S, SO, ST, STO, SJ, SJT, SJTO, and SVO. Steel/Zinc Plated Cable Cable Min. Max. 1/2 SRA-350 1.34 0.05 1.04 0.25 0.35 1/2 SRA-450 1.34 0.48 1.04 0.35 0.45 1/2 SRA-560 1.34 0.48 1.04 0.45 0.56 3/4 SRB-350 1.39 0.54 1.04 0.25 0.35 3/4 SRB-450 1.36 0.54 1.04 0.35 0.45 3/4 SRB-560 1.35 0.54 1.04 0.45 0.56 3/4 SRB-650 1.36 0.54 1.04 0.55 0.65 1 SRC-750 1.77 0.70 1.28 0.65 0.75 1 SRC-850 1.74 0.70 1.25 0.75 0.85 1 SRC-950 1.83 0.70 1.56 0.85 0.95 1 SRC-1050 1.85 0.70 1.63 0.95 1.05 Type SRA Type NCG Non-Metallic Strain Relief Cord Connectors To seal, provide strain relief, and to terminate flexible or portable cords to slip holes, knockout holes, or threaded hubs of a water-tight or liquid-tight location box or enclosure. Acme threads on nut end of body prevent skipping, speed installation. All nylon construction with the Buna-N gland resists salt water, weak acids, gasoline, alcohol, oil, grease, and common solvents. Recommend using the smallest maximum diameter fitting that will fit your application. Nylon PAGE 18 Type NCG Cable Cable D E Min. Max. 3/8* NCG-01 0.67 1.49 0.53 0.20 0.75.069.187 3/8* NCG-02 0.67 1.49 0.53 0.20 0.75.181.312 1/2 NCG-11 0.88 1.72 0.62 0.20 0.95.170.470 3/4 NCG-21 1.07 1.97 0.63 0.23 1.30.450.709 1 NCG-32 1.38 2.42 0.78 0.28 1.66.590 1.000