JEOL 6500 User Manual

Similar documents
JEOL 6700 User Manual 05/18/2009

Check that the pneumatic hose is disconnected!!!! (unless your using the BSE detector, of course)

JSM 6060 LV SCANNING ELECTRON MICROSCOPE STANDARD OPERATING PROCEDURES

Using the Hitachi 3400-N VP-SEM

SEM OPERATION IN LOW VACUUM MODE

FE-SEM SU-8020 Operating manual (Preliminary version)

Basic Operating Instructions for Strata Dual Beam 235 FIB/SEM

Dickinson College Department of Geology

General information. If you see the instrument turned off, notify MIC personnel. MIC personnel will help you insert your samples into the instrument.

Standard Operating Procedure for the Amray 1810 Scanning Electron Microscope Version: 29 NOVEMBER 2014

Scanning Electron Microscope FEI INSPECT F50. Step by step operation manual

Title: Amray 1830 SEM#2 Semiconductor & Microsystems Fabrication Laboratory Revision: D Rev Date: 03/18/2016

OPERATION OF THE HITACHI S-450 SCANNING ELECTRON MICROSCOPE. by Doug Bray Department of Biological Sciences University of Lethbridge

Operating Checklist for using the Scanning Electron. Microscope, JEOL JSM 6400.

Please follow these instructions for use of the Philips CM100 TEM. Adopted from website below.

Operating Checklist for using the Scanning Electron Microscope, JEOL JSM 6400.

2. Raise HT to 200kVby following the procedure explained in 1.6.

SEM Training Notebook

1.3. Before loading the holder into the TEM, make sure the X tilt is set to zero and the goniometer locked in place (this will make loading easier).

SEM Training Notebook

Model SU3500 Scanning Electron Microscope

Operating the Hitachi 7100 Transmission Electron Microscope Electron Microscopy Core, University of Utah

1. Preliminary sample preparation

FEI Quanta 200 ESEM Basic instructions

Basic Users Manual for Tecnai-F20 TEM

User Operation of JEOL 1200 EX II

Zeiss AxioImager.Z2 Brightfield Protocol

RAITH e-line OPERATING INSTRUCTIONS

ZEISS EVO SOP. May 2017 ELECTRON OPTICS

Full-screen mode Popup controls. Overview of the microscope user interface, TEM User Interface and TIA on the left and EDS on the right

Figure 1 The Raith 150 TWO

STEM alignment procedures

1.1. Log on to the TUMI system (you cannot proceed further until this is done).

Instructions for Tecnai a brief start up manual

Zeiss LSM 880 Protocol

FEI Tecnai G 2 F20 Operating Procedures

1.2. Make sure the viewing screen is covered (exposure to liquid N 2 may cause it to crack).

1.1. In regular TEM imaging mode, find a region of interest and set it at eucentric height.

1. Specimen Holder Removal, Loading, and Insertion

This document assumes the user is already familiar with basic operation of the instrument in TEM mode and use of the Microscope Control interface.

Zeiss LSM 780 Protocol

Amray 3600 FESEM. Standard Operating Procedure. v2.2 modified by Bryan Cord. General Notes...3. Sample Loading...5. System Loading...

Protective Equipment Nitrile gloves for handling sample holder and safety glasses for filling liquid nitrogen dewar.

Procedures for Performing Cryoelectron Microscopy on the FEI Sphera Microscope

Nanoscale Fabrication & Characterization Facility. Raith e-line EBL Users Guide (updated:aug 2 nd, 2017)

MSE 460 TEM Lab 2: Basic Alignment and Operation of Microscope

LEO 912 TEM Short Manual. Prepared/copyrighted by RH Berg Danforth Plant Science Center

Standard Operating Procedure Hitachi UHR CFE SU8230 SEM

STANDARD OPERATING PROCEDURE: JEOL TEM-2100

JEOL JEM-1400 Transmission Electron Microscope Operating Instructions

JEOL 5800LV SCANNING ELECTRON MICROSCOPE OPERATOR'S MANUAL

2 How to operate the microscope/obtain an image

The user should already be familiar with operation of the instrument in STEM mode, use of the Microscope Control interface, and TIA.

Operation Guide. Hitachi S-3400N. Variable Pressure Scanning Electron Microscope. with. Deben Peltier Coolstage

COMPACT MANUAL FOR GI USERS OF THE JEM 1400 FLASH BEGINNERS (For internal use only) Gray means additional information at the end of this mini-manual

JEOL 5DII. Operation introduction. By Serge Charlebois

CAPTURING IMAGES ON THE HIGH-MAGNIFICATION MICROSCOPE

SOP for Hitachi S-2150 Scanning Electron Microscope For review purposes only

Contents STARTUP MICROSCOPE CONTROLS CAMERA CONTROLS SOFTWARE CONTROLS EXPOSURE AND CONTRAST MONOCHROME IMAGE HANDLING

05/20/14 1. Philips CM200T. Standby Condition

Scanning Electron Microscope in Our Facility

Horiba LabRAM ARAMIS Raman Spectrometer Revision /28/2016 Page 1 of 11. Horiba Jobin-Yvon LabRAM Aramis - Raman Spectrometer

Section 1: TEM parts and functions... 2

CM20 USER GUIDE. Duncan Alexander, CIME 2010

Jeol JEM Responsible personell: Endy ( ) Online booking is compulsory!

JEOL 2010 FasTEM & DigitalMicrograph User's Guide

Scanning electron microscope

R I T. Title: Wyko RST Plus. Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 05/23/06 1 SCOPE 2 REFERENCE DOCUMENTS

Operating F20/F30 with SerialEM

How to use the Jeol 1010 TEM of GI (Liesbeth own GI version)

Bruker Dimension Icon AFM Quick User s Guide

Leica DMi8A Quick Guide

Renishaw InVia Raman microscope

USING LEICA AS LASER MICRODISSECTION (LMD6000) MICROSCOPE Written By Jungim Hur

Standard Operating Procedure Hitachi UHR CFE SU8230 SEM

This procedure assumes the user is already familiar with basic operation of the SEM and the MiraTC interface.

Strata DB235 FESEM FIB

FEI Falcon Direct Electron Detector. Best Practice Document

Functions of the SEM subsystems

Bruker Dimension Icon AFM Quick User s Guide

Leica SP8 TCS Users Manual

Swept-Field User Guide

Transmission Electron Microscopy 9. The Instrument. Outline

SOP: EDAX Eagle III Microspot XRF

LSM 710 Confocal Microscope Standard Operation Protocol

Scanning Electron Microscope. Instructions for Use

Tecnai T12 Operating Procedures

Things to check before start-up.

Operation Guide for the Leica SP2 Confocal Microscope Bio-Imaging Facility Hunter College October 2009

MSE 595T Transmission Electron Microscopy. Laboratory III TEM Imaging - I

Axioscan - Startup. 1. Turn on the Axioscan (button to the left) and turn on the computer. 2. Log on and start the ZEN Blue software from the desktop

Widefield 1. Switching on

WITec Alpha 300R Quick Operation Summary October 2018

Zeiss Axio Imager.A1 manual

RENISHAW INVIA RAMAN SPECTROMETER

Instructions for Making On-Line Reservations for Microscopes in NB11-204

BX-61: Brightfield Instruction /Continue to scroll for Fluorescent Instuctions

The operation manual of spotlight 300 IR microscope

Zeiss Axiovert 135 Fluorescence Microscope Quick Guide / Operations Manual (v. 1.0 February 09)

Confocal Raman Microscopy (WITec Alpha 300R)

Transcription:

LOG IN to your session on the computer to the left of the microscope. Starting Conditions 1. Press Ctrl-Alt-Del and log on to the microscope computer. Click on JEOL PC SEM 6500 icon. Click yes if message on screen about stage appears. JEOL 6500 User Manual 2. Click the button and read the Penning Gauge to ensure that the microscope is at appropriate vacuum (10-4 -- 10-5 Pa). If not, consult with staff. 3. Click the Stage Specimen Holder Exchange button; select the holder you are using; and click the Exchange button. Ensure that the Z Position dial on the side of the chamber is at the 10.0 mm position and that Tilt is at 0.00. Close the Specimen Exchange window. 4. Check that the lights on side of exchange chamber and front of microscope are as follows: EXCH POSN ON HLDR OFF (if it is ON there is a specimen in the chamber) GUN VALVE CLOSE (front of microscope) light ON.

Specimen Loading 1. Loosen clip on side of chamber. Press and hold Vent button until it starts to flash. 2. Swing back the door when the chamber vents. Check to see that the O-ring is properly fitted into its groove. 3. Mount specimen holder so that the bottom groove is parallel to the loading direction. The specimen should be flush with the top surface of the specimen holder. Close door, and clip shut. 4. Press and hold EVAC button until it starts to flash. WAIT until EVAC button stops flashing. 5. With two fingers, gently bring the rod down and let it self position then slide it in completely. Watch the chamber camera as you do this to ensure a secure connection. If you hear a long beep STOP! something is wrong, most likely stage not in exchange position. 6. Withdraw rod, PULL OUT COMPLETELY and tilt up until clipped ( HLDR light should be ON). 7. WAIT for 5.00E-004 Pa (or lower) Specimen Unloading 1. Set stage to exchange position. ( Exch Posn is ON). Ensure that the Z Position dial on the side of the chamber is at the 10.0 mm position and that Tilt is at 0.00. 2. Turn the SEI detector Off and close the Gun Valve ( GUN VALVE CLOSE (front of microscope) light ON.) 3. With two fingers, gently bring the rod down and let it self position then slide it in completely. Withdraw rod, PULL OUT COMPLETELY and tilt up until clipped ( HLDR light should be ON). 4. Loosen clip on side of chamber. Press and hold Vent button until it starts to flash. 5. Open chamber, check O-ring and remove specimen holder. 6. Close door, and clip shut. Press and hold EVAC button until it starts to flash.

Software Setup / Obtaining an Image 1. Set imaging parameters by clicking on the: Recipe Setup Column button to choose from a list of predefined recipes; or button to manually set parameters such as accelerating voltage, emission current, etc. 2. When the vacuum level has reached 5.00E-004 Pa (or lower), turn the SEI detector On and open the Gun Valve ( GUN VALVE CLOSE light OFF.) 3. Set Working Distance to 10mm with the Focus slider bar (that s approximately where the specimen is). The working distance will be shown in the bottom right corner of the computer screen. 4. Adjust brightness and contrast ( ACB button or manual knobs) so you can see something & initially focus with the Z position dial on the side of the chamber. [If you have little signal: do gun alignment (see below); if you see nothing, the Freeze button on the console may be lit]. 5. Moving to an area of interest on the specimen can be done with the joystick or by right-clicking the mouse. At higher magnifications, moving to adjacent areas on your specimen is actually accomplished by moving the beam. This is done by left-clicking, holding and dragging the mouse. If you exceed the range of this function, select the Image Shift Reset button in the Alignment window below. 6. Set the working distance to the desired value and coarse focus manually using the Z position dial on the side of the chamber. Fine focusing can subsequently be done with the Focus knob on console using reduced area view ( RDC Image ) Alignment Press Align on the control panel and the window to the right will appear. A good starting strategy is to sequentially highlight Gun Alignment through CL Stigmator and at each selection press the Align Clear button so that both X and Y read 0. 1. Align gun to maximize signal. At the lowest magnification increase the Probe Current to its maximum setting. Adjust contrast so you can see something. Press Align on console; ensure Gun Align is selected; and adjust X and Y knobs on control panel to maximize signal (brightness of image). Press STIG on console to turn off alignment and return Probe current to previous value (7 or 8 or whatever you want).

2. Align aperture. Alignment of the objective aperture is necessary when you observe image movement while focusing Find feature at about 5,000X or more. Turn HT Wobbler ON and adjust its amplitude. Press Align on console and select OL Aperture in the Alignment window. Adjust X and Y knobs to minimize X and Y motion of image. You may need to move the stage to keep the specimen in view. Work up to higher magnifications as needed. When done, press STIG button, turn off HT Wobbler and focus. Note: if you find that you can not correct for the wobble after significant adjustment of the X and Y knobs, consult staff the objective aperture may need to be manually centered. 3. Astigmatism correction. Roll focus and look for stretching of the image as you go up in magnification. The stretching will switch from one direction to another as you go between under and over focus. Set focus where stretching switches. Ensure that the Stig button on the control panel is lit. Adjust X and Y to get sharpest image. Work up to higher magnifications as needed. Even if stretching isn t apparent in the image, you will still need to correct for astigmatism to get well focused images If the image moves while you re adjusting the stigmators, then the stigmators themselves will have to be aligned. Select Stig Center X in the Alignment window, press Wobble on the console and adjust X and Y to minimize movement. Do the same for Stig Center Y. Note: Condenser lens astigmatism correction may be necessary when using large probe currents. Select CL Stigmator in the Alignment window and correct for astigmatism with the X and Y controls. Subsequently perform objective lens astigmatism correction Aperture alignment, astigmatism correction and fine focusing should be done well above the magnification at which your images are acquired. Acquiring an Image 1. Press ACB (Auto Contrast and Brightness) on console. 2. Press PHOTO on console (it will take about 1 min to scan). Frame will be frozen when it finishes. A Print window will appear select Cancel 3. Select the Image File Handler button to save the image. Choose your directory. 4. Select Export (this is necessary to get a micron marker). Choose Filename and Format type. 5. Press Freeze button on console to restore microscope imaging. LOG OUT of your session on the microscope computer and the computer to the left of the scope. Leave the High Tension ON

Accessing your files: Go to the Characterization Facility website (http://www.charfac.umn.edu/), select Instruments -> File Storage and Access for instructions. Recording Stage Positions: Click the Stage Map button Points Map Points File. You can Record specific positions and subsequently Go to them. Frame Integration Select the Instrument Operation button. Highlight Integration and specify the number in either the Quick View or Fine View boxes. When you press the Freeze button on the console the software will integrate the number of frames you specified. Select usual to save the image. as Make sure that Freeze Frame is highlighted when you are through with image capture

Backscattered Electron Imaging Set the working distance to 10 mm and focus the specimen using the SEI detector. Unclip detector & crank in with knob on side Watch out!!! If you hear a beep, you are hitting something withdraw BS detector, reposition sample holder and try again. Position the detector so that it is centered on the computer screen. Align the microscope and focus upon the features of interest. Turn on Centaurus system (left of computer screen). From SEI menu (at bottom of screen) choose BSE. Turn Brightness until screen display is mid grey. Raise Contrast to obtain desired image. You will need to use a slow scan--too much contrast will give a poor image. If at any time red overload light comes on (screen will go blank) turn down contrast (1/2 to 1 full turn) and hit reset button. Wait a few seconds. Press PHOTO on console to scan in image. When done: Turn off Centaurus system restore SEI imaging from menu at bottom of screen; and crank detector all the way out and pull down clip to hold it in place.