MIT400/2 CAT IV Insulation testers

Similar documents
MIT400/2 CAT IV Insulation testers

MIT400/2. CAT IV Insulation testers MIT430/2: CAT IV Insulation testers

MIT480/2 Insulation testers

MIT400 CAT IV Industrial Insulation Testers

MIT415 Insulation tester

MIT400 CAT IV Industrial Insulation Testers

MIT400 CAT IV Industrial Insulation Testers

MIT400 CAT IV Industrial Insulation Testers

MIT400 Series CAT IV Insulation Resistance and Continuity Testers

NEW PRODUCT LAUNCH SALES GUIDE MIT480/2

MIT400 Series Insulation and continuity testers

MIT400 Series Insulation and continuity testers

MIT510, MIT520 and MIT1020

MIT510/2, MIT520/2 and MIT1020/2

BMM80 Premium Insulation Multimeters

1507/1503. Insulation Testers. Technical Data. Features and benefits:

5-kV and 10-kV Insulation Resistance Testers. n CAT IV 600 V safety rating. n Line supply or battery operated

Insulation Testers and Earth Ground Testers

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

MEGGER BMM2000 Series Insulation Multimeters User Guide

1587/1577 Insulation Multimeters

BM25 Automated 5-kV Insulation Tester

The future of installation testing is here. The Fluke 1650 Series Multifunction Testers

T5-600/T Electrical Tester

AEMC Megohmmeters. AEMC Flexible Current Probe

MIT515, MIT525, MIT1025

G SAFETY WARNINGS. LT300 High current loop tester. User guide

Insulation resistance testing. A complete solution for every person.

1507/1503. Insulation Testers. Users Manual

SUBJECT TO CHANGE WITHOUT NOTICE

79/26 Series III Multimeter

Advanced Test Equipment Rentals ATEC (2832)

Megger PO BOX 9007, Valley Forge PA USA T +1 (610) F +1 (610)

Fluke 1587 FC/1577 Insulation Multimeters

Indeks: WMXXCMM60 Advanced Industrial Multimeter

TORKEL 900-series Battery Load Unit

Keysight U1461A Insulation Multimeter/ U1453A Insulation Tester

Testers: / Ohmmeters Insulation Measuring Instruments. n Compact and rugged for service calls and laboratory use. Scope of delivery:

# Digital Multimeter

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

MFT1800 series. Multifunction testers. User manual

Insulation resistance testing. A complete solution for every application

Analog Digital Multimeter with Insulation Resistance Measurement

DM-45 Digital Multimeter

Agilent U1450A/U1460A Insulation Resistance Testers

INSULATION TESTER SERIES

DM-III MULTITEST Power Quality Recorder

Fluke 370 FC Series true-rms wireless AC/DC clamp meters

MFT1700 series. Multifunction testers. User manual

ODEN AT Primary Current Injection Test System

MFT1800 Series. Multifunction testers. User Manual

Technical Data Sheet. Zeta 20

PV210. Why buy the PV210?

TORKEL 900-series Battery Load Unit

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

APPA 300 Series. The Most User-Friendly High Performance Multimeter

Agilent U1253B True RMS OLED Multimeter. Quick Start Guide

INSULATION TESTER SERIES. Flip the Cover. A Full Line-up of Insulation Testers to Suit Any Need. From Basic Testing to High Performance Analysis

RISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement

Model 77 Series IV. Digital Multimeter. Users Manual

DM-III Multitest & DM-III Multitest F Power Quality Recorders

AC/DC CLAMP METER USER S MANUAL

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

The future of installation testing is here. The 1650 Series Multifunction Testers

Fluke 1660 Series Multifunction Installation Testers

Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters

Insulation resistance testing. A complete solution for every application.

GAMMA 12 DIGITAL MULTIMETER

Fluke 1660 Series Multifunction Installation Testers

PV200. Why buy the PV200? The most compact I-V curve tracer around.

Digital insulation tester

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

Agilent U1273A/U1273AX Handheld Digital Multimeter. Quick Start Guide

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters

HT FAMILY M70 METERS. Advanced DMM with safety and LAN cables test verifies HT ITALIA

1650 Series Multifunction Installation Testers

Laboratory oil testers

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

ELECTRICAL TESTING AND SAFETY

GAMMA 10 DIGITAL MULTIMETER

GAMMA 20 DIGITAL MULTIMETER

Megohmmeter Models 6526, 6532 and 6534

Simple measurement at the best price

15B+/17B+/18B+ Calibration Manual. Digital Multimeter

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

Technical Data Sheet. Delta 1000/300

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

Agilent 970-Series Handheld Multimeters Data Sheet

DIGITAL ANALOG MEGOHMMETERS

HT COMBI419. Innovative meter designed to perform all safety test

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

Digital MultiMeter - Make your job efficiency User Instruction Manual

Transcription:

MIT400/2 CAT IV Insulation testers MIT400/2 CAT IV Insulation testers Designed for Electrical and Industrial testing Insulation testing up to 1000 V and 200 GΩ range Stabilised insulation test voltage (New) Single range, faster continuity testing from 0.01 Ω to 1 MΩ (New) Adjustable insulation test voltage from 10 V to 1000 V (New) 600 V Trms AC and DC voltage measurement Test result storage and Bluetooth downloading Live circuit detection and protection Rechargeable options for mains and car charging (New) CAT IV 600 V and IP54 DESCRIPTION The MIT400 mk2 series insulation and continuity testers are designed not just for Electrical and Industrial, but with an exceptionally wide range of applications from electrical installations, cable testing, motor testing, automotive, ESD, panel building, avionics, maintenance etc. Insulation testing has been enhanced with feedback controlled test voltages to limit over-voltage to 2%, rather than the industry standard 10-20%. A variable range has been added to allow any intermediate voltage from 10 V to 1000 V in 1 V steps, where application specific test voltages are required that do not appear in the standard ranges. Continuity testing is now significantly faster, and a single autoranging 0.01 Ω to 1.0 MΩ function replaces the ohms and kohms ranges. Retained are the 200 ma and 20 ma test options. THE MIT400 RANGE: The range consists of four instruments: MIT400/2 250 V, 500 V and 1000 V MIT410/2 50 V, 100 V, 250 V, 500 V and 1000 V + PI, DAR MIT420/2 50 V, 100 V, 250 V, 500 V and 1000 V + PI, DAR + VAR (New) and result storage MIT430/2 50 V, 100 V, 250 V, 500 V and 1000 V + PI + DAR + VAR (New) + Bluetooth download INSULATION RESISTANCE TESTING: The stabilised insulation test voltage is now accurate to +2% -0%. This compares to the industry standard +20%, providing a more accurate test voltage without the risk of over-voltage damage to circuits or components. The output voltage is maintained between 0 and 2% throughout the test range. Replacing the original MIT400 instruments the new units feature a redesigned case, back-stand, and 6 cell battery compartment with separate fuse access. Where a non-standard test voltage is required, a variable range allows the exact test voltage to be selected from 10 V up to 1000 V. and is subject to the same stabilised output control. All instruments are over-moulded for increased protection and achieve an IP54 weatherproof rating.

FEATURES INCLUDE: Test voltages (New) * - 50 V, 100 V, 250 V, 500 V and 1000 V. Variable test voltage (New) * - Adjustable test voltage from 10 V to 1000 V. 2% test voltage accuracy - The output test voltage is maintained within the tolerance or -0% +2% PASS/FAIL indication (New) * PASS or FAIL displayed depending on threshold voltage Stabilised test voltage - The voltage is feedback controlled to ensure it remains within specification throughout the full test range Test voltage display (New) - The actual test voltage is displayed on the smaller digital readout, with the measurement on the larger digital display. Measurement range displayed (New) * - The test range is displayed during selection Measurement voltage display - The measurement voltage is displayed during the test Analogue arc - The display also features an analogue arc to replicate the response of a moving coil display. PI and DAR * - Polarisation Index (PI) and Dielectric Absorption Ratio (DAR) functions - Polarisation Index (PI): 10 min / 1 minute ratio - Dielectric Absorption Ratio (DAR ): 60 sec / 30 sec ratio Timed testing * - Automatically test to a time limit High test range - Insulation testing up to 200 GΩ at 1000 V. Silicon leads - High quality flexible silicon test leads are comfortable to use and prevent measurement errors on GΩ ranges above 5 GΩ. Test inhibit - prevents testing if voltages in excess of 25 V, 30 V, 50 V, 75 V 100 V (set by the user) are detected when making insulation tests. (Default is 50 V.) Insulation buzzer - The buzzer can be set to buzz if the insulation resistance is above a user adjustable limit, set in the Setup menu. Test Lock - Holds insulation test on continuously. CONTINUITY (RESISTANCE) TESTING: Single resistance range (New) - One range fully automatic from 0.01 Ω to 1.0 MΩ. Bi-directional testing (New) * - Option for automatic bi-directional testing without reconnecting leads. 200 ma or 20 ma * - Either 200 ma or 20 ma continuity test currents are available. 20 ma test current will considerably increase battery life. Lead null - Lead resistance compensation (NULL) operates up to 10 Ω of resistance. Buzzer - ON/OFF selected by simple push button. Buzzer limit - Continuity buzzer limit alarm provides adjustment of the maximum resistance the continuity buzzer sounds. This is adjustable from 1 Ω to 200 Ω in 12 steps. VOLTAGE MEASUREMENT: True RMS voltage measurement to 600 V ac or dc with resolution from 0.1 mv. Digital voltage measurement up to 600 V ac/dc Analogue arc measurement to 600 V ac/dc Automatic display of frequency during voltage measurement. DISPLAY: The display offers a combination of Analogue arc and a dual digital readout: Analogue arc: Full display width analogue arc. Analogue arc display shows essential charge and discharge characteristics not visible on a digital display. Single pointer needle response is similar to a moving coil meter. Setup functions allow control of Buzzer limit alarms, Continuity test currents, KΩ/MΩ/GΩ or 10 4 /10 5 /10 6 (New) * Dependent on model Test ranges extend from 2 GΩ to 200 GΩ depending on test voltage as below: 50 Volts. 10 GΩ 100 Volts. 20 GΩ 250 Volts. 50 GΩ 500 Volts. 100 GΩ 1000 Volts 200 GΩ Variable 10 V to 1000 V dependent on test voltage DUAL DIGITAL DISPLAY Large main digital readout for good visibility of all main measurement results Second digital display for additional data such as: Insulation test voltage. Insulation leakage current. Supply frequency (when measuring volts). Test mode eg. PI, DAR or t ( t = Timer mode). 2

OTHER FUNCTIONS AND FEATURES Weatherproof - Every tester is sealed to IP54, providing a weatherproof case to reduce the chances of water ingress, including the battery and fuse compartment. Tough housing - Rubber over moulding combines the tough shock absorbing outer protection with excellent grip, on a strong modified ABS housing, providing an almost indestructible case. Batteries - Battery requirements are 6 AA batteries of either standard Alkaline or Nickel Metal Hydride (NiMH) rechargeable type, providing a minimum of 3000 insulation tests at 1000 V. FEATURES AND BENEFITS Designed for Electrical and Industrial testing Insulation testing up to 1000 V and 200 GΩ range Stabilised insulation test voltage (New) Single range, faster continuity testing from 0.01 Ω to 1 MΩ (New) Adjustable insulation test voltage from 10 V to 1000 V (New) 600 V Trms AC and DC voltage measurement New case design with optional magnetic hanging strap (New) Test result storage and Bluetooth downloading Live circuit detection and protection Rechargeable options for mains and car charging (New) CAT IV 600 V and IP54 VARIABLE INSULATION VOLTAGE TESTER * The variable mode provides a unique solution for awkward insulation voltage measurement applications. The range option allows an insulation test voltage from 10 V to 1000 V in 1 V steps. * Dependent on model TYPICAL APPLICATIONS INCLUDE: Commercial Avionics Military Land, Marine and Air communications Manufacturing/production line goods Electrostatic measurement Component testing Battery powered traction and lifting equipment STORAGE AND DOWNLOADING RESULTS Revised Bluetooth and pairing procedures have made the MIT430/2 far easier to pair and download data. The test results are downloaded to a CSV file which can then be opened as an Excel spreadsheet. SAFETY Designed to be exceptionally safe to use, fast detecting circuitry prevents damage to the instruments if accidentally connected to live circuits or across phases. Specifically, all instruments: Meet the international requirements of IEC61010 and EN61557. Live circuit detection inhibits insulation testing on circuits above 25 V, 30 V, 50 V, 75 V or 100 V (default 50 V). Live circuit detection and test inhibit on continuity measurements. Default display of live circuit voltage on all ranges. Detection and inhibit functions even if the protection fuse has failed. Suitable for use on CAT IV applications and supply voltages to 600 V. 3

SPECIFICATION SUMMARY TABLE INSULATION MIT400/2 MIT410/2 MIT420/2 MIT430/2 50 V / 100 V n n n 250 V / 500 V / 1000 V n n n n Variable n n PI- / DAR / Timed n n n Lock button on MΩ n n n n CONTINUITY Continuity 0.01 Ω - 1 MΩ 100 Ω n n n Auto reverse polarity (setup ON-OFF) n n n Lead null (< 10 Ω) n n n n VOLTAGE AC / DC Volts 600 V n n n n mv AC / DC range n n n n Frequency measurement 15-400 Hz n n n Input impedance 0.25 MΩ 0.25 MΩ 0.25 MΩ 0.25 MΩ CAPACITANCE Capacitance 0.1 nf - 10 μf n n OTHER FEATURES PASS/FAIL on limit alarms n n n Auto power down (setup) n n n n On board memory n n Bluetooth download + software n AA Alkaline or NiMH Both Both Both Both Recharger ready n CAT IV 600 V / CAT III 1000 V n n n n ACCESSORIES Silicone leads (red/black) n n n n Switched probe supplied n n n OPTIONAL Battery charger available n 4

SPECIFICATION All quoted accuracies are at +20 C. Insulation: Test voltage Nominal: MIT400/2 MIT410/2, 420/2,430/2 Insulation accuracy 250 V, 500 V, 1000 V 50 V, 100 V, 250 V, 500 V, 1000 V 50 Volts. 10 GΩ ± 2% ± 2 digits ± 4.0% per GΩ 100 Volts. 20 GΩ ± 2% ± 2 digits ± 2.0% per GΩ 250 Volts. 50 GΩ ± 2% ± 2 digits ± 0.8% per GΩ 500 Volts. 100 GΩ ± 2% ± 2 digits ± 0.4% per GΩ 1000 Volts 200 GΩ ± 2% ± 2 digits ± 0.2% per GΩ Service Error: BS EN 61557-2 (2007). 50V, ± 2.0% ± 2d, 100 kω - 900 kω ± 10.5% 100V, ± 2.0% ± 2d, 100 kω - 900 kω ± 10.3% 250V, ± 2.0% ± 2d, 100 kω - 900 kω ± 10.3% 500V, ± 2.0% ± 2d, 100 kω - 900 kω ± 10.3% 1000V, ± 2.0% ± 2d, 100 kω - 900 kω ± 11.5% Display range Analogue: 1 GΩ full scale Resolution 0.1 kω Short circuit/charge current 2 ma +0% -50% to EN 61557-2 (2007) Open circuit voltage insulation Test current Leakage Voltage Timer control -0% +2% ± 2V 1 ma at min. pass value of insulation to a maximum of 2 ma max. 10% ±3 digits 3% ±3 digits ±0.5% of rated voltage 60 second countdown timer Lead resistance Voltage: Voltage range Volt range accuracy Waveform Frequency: Frequency measurement range Frequency measurement accuracy Null up to 9.00 Ω AC: 10 mv to 600 V TRMS sinusoidal (15 Hz to 400 Hz) DC: 0 to 600 V AC: ±2% ±1 digit DC: ±2% ±2 digit Service Error: BS EN 61557-1 (2007) - ± 2.0% ± 2d, 0 V - 300 V AC/DC ± 5.1% Unspecified range: 0 10 mv (15 to 400 Hz) For non-sinusoidal waveforms additional specifications apply Non-sinusoidal waveforms: ±3% ± 2 digits >100 mv to 600 V TRMS ±8% ± 2 digits 10 mv to 100 mv TRMS 15 Hz - 400 Hz ±0.5% ± 1digit (100 Hz to 400 Hz unspecified) Capacitance measurement: MIT420/2, MIT430/2 Capacitance measurement 1 nf to 10 μf Capacitance measurement ± 5.0% ± 2 digits accuracy (0.1 nf - 1 nf unspecified) Storage: Result storage (MIT420/2 and MIT430/2): Storage capacity >1000 test results Data download Bluetooth wireless Bluetooth Class II Note Continuity: Continuity measurement Above specifications only apply when high quality silicone leads are being used. 0.01 Ω to 999 kω (0 to 1000 kω on analogue scale) Continuity accuracy ± 3% ± 2 digits (0 to 100 Ω ) ±5% ±2 digits (100 to 500kΩ) (500kΩ to 1MΩ unspecified) Service Error: BS EN 61557-4 (2007) - ± 2.0%, 0.1 Ω - 2 Ω ± 6.8% Open circuit voltage Test current Polarity 5 V ± 1 V 200 ma ( 0 ma +20 ma) (0.01 Ω to 4 Ω) Single polarity (Default) / Dual polarity (configurable on setup). Range Power supply Battery life Dimensions Weight up to 10 m 6 x 1.5 V cells type IEC LR6 (AA, MN1500, HP7, AM3 R6HP) Alkaline 6 x 1.2 V NiMH rechargeable cells may be used 3000 insulation tests with duty cycle of 5 sec ON /55 sec OFF @ 1000 V into 1 MΩ Charger (Optional): 12-15 V dc (accessory interface) Instrument 228 mm x 108 mm x 63 mm (9.00 in x 4.25 in x 2.32 in) 600 g (MIT400/2), (1.32 lb) 5

Weight (instrument and case) Fuse Safety protection 1.75 kg (3.86 lb) Use only 1 x 500 ma (FF) 1000 V 32 x 6 mm ceramic fuse of high breaking capacity HBC 30 ka minimum. Glass fuses MUST NOT be fitted. The instruments meet EN 61010-1 (1995) to 600 V phase to earth, Category IV. Refer to safety warnings supplied. EMC In accordance with IEC 61326 including amendment No.1 Temperature co-efficient Environmental: Operating temperature range and humidity <0,1% per C up to 1 GΩ <0,1% per C per GΩ above 1 GΩ -10 to +55 C 90% RH at 40 C max. Storage temperature range -25 to +70 C Calibration temperature +20 C Maximum altitude 2000 m IP rating IP 54 The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG, Inc and is used under licence. 6

Description Language group 1 - English - French - German - Dutch MIT400/2-250V, 500V 1000V Insulation tester 1004-731 and timed testing 1004-735 storage and recall 1004-739 recharge ready 1004-740 ORDERING INFORMATION Order Code Description Order Code Language group 6 - English - Hungarian - Romanian - Russian MIT400/2-250V, 500V 1000V Insulation tester 1006-724 and timed testing 1007-736 storage and recall 1006-744 recharge ready 1006-750 Language group 2 - English - Spanish - Italian - Portuguese MIT400/2-250V, 500V 1000V Insulation tester 1006-719 and timed testing 1006-732 storage and recall 1006-740 recharge ready 1006-746 Language group 3 - English - Arabic - Turkish - French MIT400/2-250V, 500V 1000V Insulation tester 1006-721 and timed testing 1006-733 storage and recall 1006-741 recharge ready 1006-747 Language group 7 - English - Finnish - Norwegian - Swedish MIT400/2-250V, 500V 1000V Insulation tester 1006-725 MIT410/2 - as MIT400/2 + 50 V and 1000 V, PI, DAR and timed testing 1006-737 storage and recall 1006-745 recharge ready 1006-751 Included Accessories Red/Black Silicone test leads with Probes + Clips SP5 remote switch probe (not MIT400/2) Owners information CD Batteries 6 x AA Alkaline Hard carry case Language group 4 - English - Czech - Slovak - Polish MIT400/2-250V, 500V 1000V Insulation tester 1006-722 and timed testing 1006-734 storage and recall 1006-742 recharge ready 1006-748 Optional Accessories UKAS calibration certificate 1000-085 Mains Charger kit (MIT430/2 only) 1007-464 12 V DC car charger (requires mains charger kit) 1004-183 SP5 remote switch probe (not MIT400/2) 1007-157 Test lead set and crocodile clips 1002-001 2 wire 500 ma fused test lead set 1002-015 Batteries (6 x NiMH) 1002-735 Language group 5 - English - Chinese - Japanese - Korean MIT400/2-250V, 500V 1000V Insulation tester 1006-723 and timed testing 1006-735 storage and recall 1006-743 recharge ready 1006-749 SALES OFFICE Megger Limited Archcliffe Road Dover CT17 9EN England T +44 (0) 1304 502101 E UKsales@megger.com MIT4002_DS_en_V04 www.megger.com ISO 9001:2008 The word Megger is a registered trademark