LPS. TE20 15W-20W Single Output External Power Test & Measurement/Industrial Series. Features

Similar documents
TE40 40W Single Output External Power Test & Measurement/Industrial Series

TE60 60W Single Output External Power Test & Measurement/Industrial Series

TE60 60W Single Output External Power Test & Measurement/Industrial Series

TE90 90W Single Output External Power Test & Measurement/Industrial Series

TE W Single Output External Power Test & Measurement/Industrial Series

FEATURES AND BENEFITS. Compact size: 6.5 x 2.8 x 1.5

TB65 65W Single Output Test and Measurement/Industrial Series

MB120S 120W Single Output Medical Series

LB115S 115W Single Output

Model Selection Model Output Current Total OVP Number Class Volts (Convection Cooled) Efficiency 1 Ripple &Noise 2 Regulation Threshold

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

Doc. EA Model Number:

Output Power Output Voltage (3) Output Current Total Regulation (2) Efficiency (5) Model Number (1,6) 8 W 3.3 VDC 2.50 A 7% 68% AEL15US03 (4) 12 W

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

Product Specification sheet

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

Compliance. Safety Approvals USA Canada Europe. Isolation: General. Dimensions. AC Input CN1 Output CN2 Optional CN3. Weight

LFWLP W 12V 15.00A 25.00A 92%

CLP0205 Open Frame Power Supply Vac input; 5Vdc output; 200W Output Power; 0.25A stdby

Features. Regulated Converter RAC05- SK/C14. RAC 5 Watt Single Output RAC05-3.3SK/C14. AC/DC Converter

Features. Regulated Converter RACM Watt Enclosed & Open Frame Case Style Single Output RACM65- S / - AC/DC Converter.

HEC-45LTN-45PFAS Rev A

Note1: Max Cap Load is tested at minimum input and full resistive load. Connections (3) Case Style (1)

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

C B. Models. Models 2MOPP

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max.

CLP0112 Open Frame Power Supply Vac input; 12Vdc output; 150W Output Power

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS18 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

Features. Regulated Converters. RACM40 40 Watt Enclosed & Open Frame Case Style Single Output RACM40- S / - AC/DC Converter.

Features. Regulated Converters. RAC05-K 5 Watt 1 x 1 Single Output RAC05- SK. AC/DC Converter

For more information, please visit the product page. output. output current max (A)

Sirius 250/350 Watts, Single / Multi output AC-DC, modular power solution

HEC-70LCN-350TDAF Rev B

General. Environmental. EMC & Safety

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

Electrical Specifications

IEC/EN/UL60950 & CE certified, EN55032 Class B

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

HEC-30/35LTA-33TDAA Rev A

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

Electrical Specifications. Input Current 115 VAC: 1.2 A max. 230 VAC: 0.65 A max.

Features. Regulated Converters. RACM Watt Enclosed Case Style Single Output. RACM150- S/ _ Fan Option (1) Single. AC/DC Converter.

Parameter Condition Min. Typ. Max. Internal Input Filter. refer to line derating graph on PA-4 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

150 Watt Industrial (WLT)

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

These medical power supplies are ideal for, monitoring, home health equipment as well as surgical devices.

Metal Case Power Supplies

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet

Features. Regulated Converter. RAC05-K 5 Watt 1 x 1. Single Output RAC05- SK. AC/DC Converter

IP67 DESCRIPTION KEY FEATURES MARKET SEGMENT AND APPLICATIONS TRC ELECTRONICS, INC

Features. Regulated Converter. RAC05-K/277 5 Watt Single Output RAC05- SK/277/W. AC/DC Converter

Note1: Efficiency is tested at nominal input and full load at +25 C ambient Note2: Max Cap Load is tested at nominal input and full resisitive load

Asia-Pacific North America Europe, Middle East Bel Power Solutions, Inc. BCD.

CB Scheme UL508 UL ATEX II3G

Efficiency [%] 115VAC 230VAC. Parameter Condition Value. Line Regulation low line to high line ±0.5% max. Load Regulation 10% to 100% load ±0.5% max.

Output Voltage* (nom.)(adjustable)

HEC-35LTA-XXTSAA Rev A

VOF XX - XXX - X

Features. Regulated Converter RAC Watt Single Output. AC/DC Converter

General. Efficiency Isolation. Dimensions Net Weight. Safety & EMC

Features. Regulated Converter. RAC02-SE/277/W 2 Watt Single Output. RAC02- SE/277/W Wired. AC/DC Converter

HEC-150RTN-48QSCA. A. Features. B. Description. C. Models. D. Electronic Specifications - Input Specifications

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

Features. Regulated Converter. RAC02-SE/277 2 Watt Single Output RAC02- SE/277. AC/DC Converter

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

Watts HCP Series

CLP0224 Open Frame Power Supply Vac input; 24Vdc output; 200W Output Power

HEC-40LTN-XXPSCA Rev A

5 x 3 x 0.75 Inches form factor. 275 Watts with Forced Air Cooling. Efficiencies up to 92% Standby Power < 0.5 W

420 W High Line Output Power. Rugged Industrial Construction. -40 C to +70 C Operation. 5 V Standby. Screw Terminals. SEMI F47 Compliant

SAMSUNG ELECTRO-MECHANICS CO., LTD

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

MVAB120 Series 120W 2" x 4" AC-DC Power Supply Converter

Output Voltage nom. (adjustable)

Output Voltage nom. (adjustable)

Line Reg Load Reg Ripple Efficiency *Model Number Output V Output I (nom/max) (nom/max) & Noise (min/nom)

MAD40 MULTI -OUTPUT SERIES OPP SCP OVP. 2 X 3.5 Inch AC-DC POWER SUPPLIES. UNIVERSAL INPUT RANGE UP TO 40Watts PART NUMBER STRUCTURE LOW CROSS REG.

Model Number Output V1/V2/V3 Output I1/I2/I3 max. Ripple & Noise Efficiency(min/nom) Capacitive Load

NLP40 SERIES 50 Watt Open Frame Power Supply Measures: 4.25 x 2.50 x 1.15

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms

HEC-100RTA-48QSCA Rev A1.0

The MBC550 range is ideally suited to a wide variety of medical applications, and also where airflow is limited or not available.

General. Environmental. EMC & Safety

QUARTER-BRICK SERIES Single Output Performance Products

PDAM500 Series 500W Power Supply

Power Factor (2) 600 ma 90 ~ 305 Vac Vdc 34.2 W 86% 0.95 LUC-040S060RSP. Efficiency (2) Parameter Min. Typ. Max. Notes

Features. Switching Regulator. 2.0 Amp SIP3 Single Output R-78B-2.0 R-78B DC/DC Converter

Features. Regulated Converters. RAC01-C RAC02-C 1-2 Watt Single Output RAC0_- C. AC/DC Converter

SFD550-12BG Front-End Preliminary Data Sheet DC Input, 12V Output, 550 Watts

QUARTER-BRICK SERIES Single Output Value Products

Features. Regulated Converter. RAC04-C/277 4 Watt Single and Dual Output RAC04- C/277 -_. AC/DC Converter

Electrical Specifications

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Transcription:

LPS Features Meets DoE Efficiency Level VI Requirements No load input power Average Efficiency Up to 20W of AC-DC Power Universal Input 90-264Vac Input Range Desktop and Wall-Plug versions Meets Heavy Industrial Levels of EN61000 EMC Requirements Meets EN55022/CISPR22, and FCC Part 15.109 Class B Conducted & Radiated Emissions, with 6db margin Approved to EN/IEC/UL60950-1, 2 nd Ed., Am. 2 E-cap life of >10 years >1,000,000 Hours MTBF 3 Year Warranty IP22 Rated Enclosure Description A high performance AC to DC external power supply family designed for test & measurement and industrial applications. The TE20A Series models are compliant with Efficiency Level VI requirements per U.S. Dept. of Energy, as well as the Heavy Industrial levels of various EN61000-4-x standards for EMC. The TE20A series models also meet Class B conducted and radiated emissions per FCC Part 15, EN55022, and CISPR22. These superior performance external power supplies are designed to allow easy integration with test and measurement equipment and other industrial applications. Model Selection Model Output Output Ripple & Line Load Output Input Number Volts Current Power Noise¹ Regulation Regulation Connector Configuration TE20A0503F01 5.0V 3.00A 15W 75mV pk-pk ±1% ±5% TE20A0603F01 5.9V 2.50A 15W 75mV pk-pk ±1% ±5% TE20A0703F01 7.5V 2.00A 15W 75mV pk-pk ±1% ±5% TE20A0903F01 9.0V 2.00A 18W 90mV pk-pk ±1% ±5% TE20A1203F01 12.0V 1.50A 18W 120mV pk-pk ±1% ±5% TE20A1503F01 15.0V 1.20A 18W 150mV pk-pk ±1% ±5% TE20A1803F01 18.0V 1.10A 20W 180mV pk-pk ±1% ±5% TE20A2403F01 24.0V 0.83A 20W 240mV pk-pk ±1% ±5% TE20A4803F01 48.0V 0.42A 20W 480mV pk-pk ±1% ±5% TE20A0503N01 5.0V 3.00A 15W 75mV pk-pk ±1% ±5% TE20A0603N01 5.9V 2.50A 15W 75mV pk-pk ±1% ±5% TE20A0703N01 7.5V 2.00A 15W 75mV pk-pk ±1% ±5% TE20A0903N01 9.0V 2.00A 18W 90mV pk-pk ±1% ±5% TE20A1203N01 12.0V 1.50A 18W 120mV pk-pk ±1% ±5% TE20A1503N01 15.0V 1.20A 18W 150mV pk-pk ±1% ±5% TE20A1803N01 18.0V 1.10A 20W 180mV pk-pk ±1% ±5% TE20A2403N01 24.0V 0.83A 20W 240mV pk-pk ±1% ±5% TE20A4803N01 48.0V 0.42A 20W 480mV pk-pk ±1% ±5% TE20A0503Q01 5.0V 3.00A 15W 75mV pk-pk ±1% ±5% TE20A0603Q01 5.9V 2.50A 15W 75mV pk-pk ±1% ±5% TE20A0703Q01 7.5V 2.00A 15W 75mV pk-pk ±1% ±5% TE20A0903Q01 9.0V 2.00A 18W 90mV pk-pk ±1% ±5% TE20A1203Q01 12.0V 1.50A 18W 120mV pk-pk ±1% ±5% TE20A1803Q01 18.0V 1.10A 20W 180mV pk-pk ±1% ±5% TE20A1503Q01 15.0V 1.20A 18W 150mV pk-pk ±1% ±5% TE20A2403Q01 24.0V 0.83A 20W 240mV pk-pk ±1% ±5% TE20A4803Q01 48.0V 0.42A 20W 480mV pk-pk ±1% ±5% Class I Desktop, IEC60320 C14 Class II Desktop, IEC60320 C8 Class II Desktop, IEC60320 C18 www.slpower.com TE20 Rev 2.8 28-FEB-17 1

Model Selection (continued) TE20A0503B01 5.0V 3.00A 15W 75mV pk-pk ±1% ±5% TE20A0603B01 5.9V 2.50A 15W 75mV pk-pk ±1% ±5% TE20A0703B01 7.5V 2.00A 15W 75mV pk-pk ±1% ±5% TE20A0903B01 9.0V 2.00A 18W 90mV pk-pk ±1% ±5% TE20A1203B01 12.0V 1.50A 18W 120mV pk-pk ±1% ±5% TE20A1503B01 15.0V 1.20A 18W 150mV pk-pk ±1% ±5% TE20A1803B01 18.0V 1.10A 20W 180mV pk-pk ±1% ±5% TE20A2403B01 24.0V 0.83A 20W 240mV pk-pk ±1% ±5% TE20A4803B01 48.0V 0.42A 20W 480mV pk-pk ±1% ±5% TE20A0503C01 5.0V 3.00A 15W 75mV pk-pk ±1% ±5% TE20A0603C01 5.9V 2.50A 15W 75mV pk-pk ±1% ±5% TE20A0703C01 7.5V 2.00A 15W 75mV pk-pk ±1% ±5% TE20A0903C01 9.0V 2.00A 18W 90mV pk-pk ±1% ±5% TE20A1203C01 12.0V 1.50A 18W 120mV pk-pk ±1% ±5% TE20A1503C01 15.0V 1.20A 18W 150mV pk-pk ±1% ±5% TE20A2403C01 24.0V 0.83A 20W 240mV pk-pk ±1% ±5% TE20A2403C01 24.0V 0.83A 20W 240mV pk-pk ±1% ±5% TE20A4803C01 48.0V 0.42A 20W 480mV pk-pk ±1% ±5% TE20 Notes: 1. Measured at the output connector, with noise probe directly across output and load terminated with 0.1μF ceramic and 10μF low ESR capacitors. For 5V and 6V models, values listed are typical, 100mV pk-pk maximum with 0.1μF ceramic and 47μF low ESR capacitors used at measurement point. 2. Order blade kit KT-1027K for other blades (EU. UK, Australia) 3. For EU fixed blades, replace C in the model number with M, for UK blades, replace C with G, for Australia blades, replace C with H. 4. For Input Class I models: For AC GND connected to output common (-), insert a B in the part number where the A is located (TE20B0503F01). 5. All specifications are typical at nominal input, full load, at 25 C ambient unless noted. General Specifications Class II Wall-Plug, Interchangeable Blades (North American Blade included)² Class II Wall-Plug, Fixed North American Blades AC Input 100-240Vac, ±10%, 47-63Hz, 1 Turn On Time Less than 700mS @115Vac, full load Input Current 115Vac: 0.5A, 230Vac: 0.25A Hold-up Time 20mS min., at full Load, 100Vac input Inrush Current 264Vac, cold start: will not exceed 40A Overtemperature Will shutdown upon an overtemperature condition, auto-recovery. Input Fuses F1, F2: 3.15A, 250Vac fuses (line & neutral lines) provided on all models Overload 130 to 180% of rating, Hiccup Mode Earth Leakage Current Input-GND: <500μA@264Vac, 60Hz, NC Output-GND: <4mA@264Vac, 60Hz, NC Short Circuit Hiccup Mode, auto recovery. Efficiency Meets US DoE Efficiency Level VI Average efficiency levels Overvoltage 130 to 150% of output voltage, hiccup mode Output Power 15 to 20W continuous See models chart for specific voltage model ratings. Isolation Input-Output: 4000Vac Input-Ground: 1500Vac Output-Ground: 1500Vac No Load Input Power <0.1W per DoE Efficiency Level VI Requirements Safety Standards EN/CSA/UL/IEC 60950-1, 2nd Edition, Am 2 Ripple and Noise See models chart on pg 1. Operating Temperature -20 C to +70 C Start Up at -40 C, full load, (warmup period before all parameters are within published specifications). Output Voltage See models chart on pg 1. Transient Response 500µs response time, return to within 0.5% of final value for any 50% load step over 5% to 100% of rated load, i/ t< 0.2A/µs. Max. voltage deviation is +/-3.5%. Temperature Derating Storage Temperature Regulation See models chart on pg 1. Altitude Drop Test 1.4m from table top to wooden platform, 6 faces. Relative Humidity See Derating Chart -40 C to +85 C Operating: to 5000m. Non-operating: -500 to 40,000 ft. 5% to 95%, non-condensing www.slpower.com TE20 Rev 2.8 28-FEB-17 2

General Specifications (continued) Vibration E-Cap Life Operating: 0.003g/Hz, 1.5grms overall, 3 axes, 10 min/axis, 1-500Hz. Non-Oper.: random waveform, 3 minutes per axis, 3 axes; Sine waveform, Vib. frequency/ acceleration: 10-500Hz/1g, sweep rate of 1 octave/min., Vibration time of 10 sweeps / axes, 3 axes >10 year life, based on calculations at 115Vac/60Hz & 230Vac/50Hz, 25 C at 24 hrs per day, 365 days/year, 6 power up cycles per day. (@80% load for the 12V model) All specifications are typical at nominal input, full load, at 25 C ambient unless noted. Shock MTBF Operating: Half-sine, 20gpk, 10mS, 3 axes, 6 shocks total Non-Operating: Half-sine waveform, impact acceleration of 100G, Pulse duration of 6 ms, Number of shocks: 3 for each of the three axis >1,000,000 hours, full load, 110 & 220Vac input, 25 C amb., per Telcordia 332 Issue 6, Stress Method. EMI/EMC Compliance Conducted Emissions: Radiated Emissions: Common Mode Noise: Electro-Static Discharge (ESD) Immunity on Power ports: Radiated RF EM Fields Susceptibility Electrical Fast Transients (EFT) /Bursts: Surges, Line to Line (Diff Mode) and Line to GND (CMN Mode) Conducted Disturbances induced by RF Fields Rated Power frequency magnetic fields Voltage Interruptions, Dips, Sags & Surges Harmonic Current Emissions Flicker Test EN55011/CISPR22 Class B, FCC Part 15.107, Class B: 6db margin typ, at 115 and 230Vac EN55022/CISPR22 Class B, FCC Part 15.109, Class B: 3db margin typ, at 115 and 230Vac High Frequency (100kHz-20MHz): <40mA pk-pk EN55024/IEC61000-4-2, Level 4: +/- 8kV contact, +/- 15kV air, Criteria A EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, 80% AM at 1kHz EN55024/IEC61000-4-4, Level 4, +/- 4.4kV, 100Khz rep rate, 40A, Criteria A EN55024/IEC61000-4-5, Level 4, +/-2kV DM, +/-4kV CM, Criteria A EN55022/IEC61000-4-6, 3V/m Level 4, 0.15 to 80Mhz; and 12V/m) in ISM and amateur radio bands between 0.15Mhz and 80Mhz, 80% AM at 1KHz EN55024/IEC1000-4-8, Level 4: 30A/m, 50/60 Hz EN55024/IECEN61000-4-11: --100% dip for 20mS, Criteria A --100% dip for 5000mS (250/300 cycles), Criteria B --60% dip for 100mS, Criteria B --30% dip for 500mS, Criteria A EN55011/EN61000-3-2, Class A EN61000-3-3 All specifications are typical at nominal input, full load, at 25 C ambient unless noted. Mechanical Drawing Notes: 1. Weight: 110g. 2. All dimensions in mm. 3. Interchangeable blade models come with North American blade fitted. For other blades (EU, UK, Aust.) order blade kit KT1027K. 4. The unit should not be covered or enclosed to protect against excessive case temperature rise. IEC60320 C14, Barrel Connector Interchangeable N.A. Blade, barrel connector www.slpower.com TE20 Rev 2.8 28-FEB-17 3

Derating Chart: 25 20 Watts 15 10 5V 12V-18V 24V 48V 5 0-20 -10 0 10 20 30 40 50 60 70 Ambient Temperature C Connector Information Standard models include a straight barrel type connector (Ault #3),. Other standard options are listed below. The 03 in the standard model number is replaced by the applicable digits below: www.slpower.com TE20 Rev 2.8 28-FEB-17 4

Efficiency Level VI Information: TE20A Series Data Sheet 2017 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. www.slpower.com TE20 Rev 2.8 28-FEB-17 5