CM80 Series Vari-Angle IR Illuminator

Similar documents
CM48 Series Vari-Angle IR Illuminator

CA80 Series Vari-Angle IR Illuminator

Datasheet ENGLISH Halogen lamp 120W with motion sensor ( ) Halogen lamp 400W with motion sensor ( )

Outdoor Enclosure. VIVOTEK Pan/Tilt & Fixed Dome Series. Installation Guide

Traffic Safety Corporation

Mounting Accessories. Installation Guide. VIVOTEK SD83XXE Speed Dome

Installation Instruction

Instruction Manual. Self-Leveling Cross-Line Laser Level Model No and

Tauten Tab Tension Screen User Manual

Tube Facing Tool.

SAM. Model: STV-C65 LCD Mobile Visualized Stand Instruction Manual. Weight Capacity: 1251bs / 56.7kg Suits LCD Flat Panel Display: 42"-55" Page 20

INSTALLATION INSTRUCTIONS Small Flat Panel Height-Adjustable, Extended Pitch Swing Arm Wall Mount Model KWE-110

Installation and Assembly: Flat Video Wall Mount For 40" to 65" Flat Panel Displays

Tilting & Swiveling Plasma/LCD Flat Panel Wall Mount Installation Guide Model: A380SM

Important Loading Information. Tools Required. Meridian Lateral Files Instructions

Tilting, Swiveling & Rotating Flat Panel Wall Mount

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

LXE Mounting Holes on Base. Warranty. Compliant IEC. Brightest linear light yet, delivering up to 100,000 lux in OverDrive mode

INSTALLATION MANUAL PBL-UMP

LXE300. Four Mounting Holes on Base. Compliant IEC. Warranty

Assembly Instructions Nevins Phone Booth

LCD TV WALL MOUNT INSTALLATION INSTRUCTIONS. DUAL Swing Arm (RFWD-110) WARNING

Swing Arm TV Wall Mount. Model Number: ASWM-1015 INSTRUCTION MANUAL

Installation and Assembly: Articulating Swivel Arm for 37" - 60" Flat Panel Displays

Quolis 5000 Light INSTALLATION AND OPERATION INSTRUCTIONS. Model AL-820 IMPORTANT

INSTALLATION INSTRUCTIONS Small Flat Panel FMA Pivot Arrays Models: FMA-220 and FMA-320

UR20/UR28 Ouro Site/Area Luminaire Installation Instructions

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Always there to help you. Register your product and get support at AE2430. User manual

Wall mounting bracket

Model WHD Weld Hole Detector Operator s Manual. Rev 1.1

INSTALLATION INSTRUCTIONS DODGE RAM 2 & 4WD 1500 PART # P5058

Universal Projector Ceiling Mount Model: DPM-45

INSTALLATION INSTRUCTIONS GRILLE GUARD RAM 1500 PART # 5058/5058-2

Flat Panel Stand FPZ-655. for 32" to 55" Flat Panel Screens FEATURES. Reinforced universal adapter plate for a strong hold

GMR FANTOM 50/120 SERIES INSTALLATION INSTRUCTIONS

Installing flat panels on the MPL15 wall mount

Wall Mounting Bracket

Installation and Assembly: In-wall Mount for 32" to 71" Flat Panel Displays

Assembly Instructions Nevins Phone Booth

Desktop Magnifier. User s Guide

**MOUNTING YOUR MONITOR

INSTALLATION MANUAL PBC-UMS

Important Safety Information

Model OB-ITF Infrared Through-Beam Fiber Optic Optical Barrier Operator s Manual. Version

Installation and Assembly: Full Service Video Wall Mount

Showpiece Cabinet Integrated Stand For 32" - 52" LCD HDTV

Band-Master ATS Nano Pneumatic Banding Tool Operating Instructions

Worktop. Weight Capacity. 100 lbs. 21 Corner Worktop. 48 Worktop. Fits over 2 Cabinets. 72 Worktop. Fits over 3 Cabinets. 200 lbs. 150 lbs.

Full Motion Gas Spring TV Wall Mount - 24" to 55" Installation Instructions

Pergola PR100N1. Assembly Instructions. Systems Trading Corporation Customer service: (877)

EllisSaw.com. EllisSaw.com P.O. Box Verona, WI

Operation. 1 of 14. Serial number label

RM75. Miniature Mini IP 50 RING LIGHT LOW-ANGLE MULTI-DRIVE TM PRODUCT HIGHLIGHTS 5-PIN M12. RoHS YEAR. smartvisionlights.com. Compliant CE.

Tilting Flat Panel Wall Mount Installation Guide

SM-RAZOR-T-M/L/XL. Strong Low Profile Tilt Mount for Ultra-Thin Flat-Panel TVs INSTRUCTION MANUAL

LM45 MULTI-DRIVE TM. Miniature Mini LINEAR L IGHT IP 65 PRODUCT HIGHLIGHTS. RoHS YEAR. smartvisionlights.com. Compliant CE. Warranty.

INSTALL INSTRUCTIONS WELCOME TO THE NEWAGE PERFORMANCE CABINETRY SERIES NEWAGE STEEL WELDED CABINETRY

ASSEMBLY AND INSTALLATION INSTRUCTIONS

REVAMP4100 Instruction manual

INSTALLATION INSTRUCTIONS

User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer.

TYGER GUARD. Parts List BEFORE INSTALLATION WARNING TG-GD6D /7. Tyger Guard. Tube Brackets (Bull Bar) passenger or driver side

Operating Instructions GEMINI R

Fixed Wall Arm. Installation Guide. Part number Rev E 2012 PolyVision Corporation All rights reserved

Installation Guide Installation Kit for Mounting Philips MP20/30/40/50 on Datex-Ohmeda Aisys Anesthesia Machine

Diode Pointer Quick Start Guide

Top spin Nr /

Gazebo GZ3584 Aluminum Composite Roof Panels

Display-Top Apothecary Cabinet. Assembly Instructions. Page 1

ARROW SAW PRECISE CUT 8000 RPM WITH DUST COLLECTING ATTACHMENT INSTRUCTION BOOK MODEL NO

MSP-DCCPGTU Large Screen Tilt Display Mount

INSTALLATION INSTRUCTIONS Medium Flat Panel Model MSP-SI1

Installation and Assembly: In-wall Mount for 32" to 71" Flat Panel Screens

M508 GPS Tracking Device

Small Flat Panel Height-Adjustable Dual Swing Arm Wall Mount With Universal Slat Wall Mount (MSP-JS-KWG-110)

MTS-SP100. RENOGY Pole Mount System E Philadelphia St, Ontario, CA Version: 1.2

TITAN INDUSTRIAL RACK 6-FOOT TALL / 4-SHELF

INSTALLATION INSTRUCTIONS

Medium Flat Panel Dual Swing Arm Wall Mount JWD-V

Installation and Assembly: Flat \ Tilt Wall Mount for VESA 400x400

Flat Panel Dual Swing Arm Wall Mount (FWD-110) MSP-SA

Jenny Legs Assembly Instructions

Gared Pro-S Portable Backstop

Installation and Assembly: Flat Panel Pull-out Swivel Wall Mount

SB-WM-ART2-L-BL SB-WM-ART2-XL-BL

This instruction manual is an in-depth look and explanation of how to assemble and install the Murphy Bed properly and efficiently.

GMR 420/620/1220 xhd2 Series Installation Instructions

WireCrafters, LLC. General Information

ADULT ASSEMBLY REQUIRED DUE TO THE PRESENCE OF SMALL PARTS, SHARP POINTS, SHARP EDGES

Register your product and get support at AE2330. User manual

SM-RAZOR-F-M/L/XL. Strong Low Profile Fixed Mount for Ultra-Thin Flat-Panel TVs INSTALLATION MANUAL

Wooden Frame Type Instruction Manual

One Shelf, Wall Mounted A/V Component Stand Installation Guide Model: EX101SS

Important safety instructions

Video Wall Installation Instructions 2W X 3H, 3W X 3H

Warnings. Description. Prior to Installation Tools Needed

Installation Instructions

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

RMX75. Miniature Mini IP 65 RING LIGHT MULTI-DRIVE TM PRODUCT HIGHLIGHTS 5-PIN M12. RoHS YEAR. smartvisionlights.com. Warranty.

Transcription:

CM80 Series Vari-Angle IR Illuminator Installation Guide Rev. 1.1 QIG Part no.: 625040201G

Revision History: * Rev. 1.0: Initial Release * Rev. 1.1: Added safety instructions and warning messages. Package Contents X1 X3 X2 X2 The 1/4" screws and washers are used to secure the illuminator to an external camera housing. NOTE: The wall-mount (CMA-B04), corner-mount (AM-412), polemount adaptor (AM-311/312), and other brackets are separately purchased. The screws and anchors for securing the illuminator to wall are user-supplied. Apply M6 anchors or screws. WARNING: Please avoid eye exposure or apply appropriate protection, such as wearing a pair of Infrared protection glasses, when working with the product. Always use camera live view to oberve IR lighting effects. The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 2.5 m is not expected. The external flexible cable or cord of this luminaire cannot be replaced; if the cord is damaged, the luminaire shall be destroyed. The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced. Please make sure Reinforce/Double insulation shall be maintained between LV supply and control circuits after installation. This flood light shall be used with a IEC/EN 61347-2-13 approved LED driver with SELV output equal to rated voltage of the luminaire, and output power of LED drivers shall be at least equal to rated power of the luminaire. Terminal block is not included. Installation may require advice from a qualified personnel. 2

RISK GROUP 3 WARNING IR emitted from this product, Do not look at operating lamp. IR illuminators RISK GRORP 3 / WARNING IR emitted from this product. / Avoid eye exposure. Use appropriate shielding or eye protection. Do not look at operating lamp. Class III luminaires Do not stare at the operating light source. This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling. IMPORTANT: Do not install the product with unstable brackets, or installed on fragile mount surfces. This product shall be used in compliance with local laws and regulation. Please avoid using chemical or aerosol cleaning fluids to clean the product. Use a clean cloth slightly moistened with water. This product contains no parts repairable by the users. Contact CaMate for services. Power off the Illuminator as soon as smoke or unusual odors are detected. Do not place the Illuminator on unsteady surfaces. Replacing or failing to properly install the waterproof components, e.g., cables or cable glands, will void our IP67 warranty. Refer to your datasheet for the operating temperature. Do not touch the Illuminator during a lightning storm. 3

Mechanical Drawings Standard Small U bracket 4

I Hardware Overview Reserved mounting holes for external camera housing U bracket Waterproof cover for angle selector Mounting holes Optional mounting points for U bracket Dehumidifier membrane Reserved Combo cable Light sensor Unit Weight: 2.1KG. Max. Project Area: 34684.7mm 2. 5

II Installation IMPORTANT: It is highly recommended that the illuminator should be installed at a position higher than 3 meters from the ground. U Bracket Positions & Orientation Use the included allen wrench to attach and adjust the U bracket to your needs at the installation site. 6

You must first survey the installation site and determine the illumination distance. Use a coin or flat blade screwdriver to open the waterproof cover at the back of the illuminator. 35-Kg-cm Tips: You may forget your current beam angle configuration. In this case, turn many full circles clockwise until the rotation resistance is felt (returns to the widest angle, reaches its mechanical stops), and then turn the selector counter-clockwise according to the angle listed on the tables. Each full circle corresponds to a preset beam angle. Use the 4mm side of the allen wrench to turn the beam angle to an estimated illumination distance, e.g., 200 meters. See the tables on the next page for how to do it. Angle narrower Longer distance Angle wider Shorter distance Beam angle selector 7

The factory default for the beam angle selector is always at the Widest angle. When you turn the selector many rounds to its widest or the narrowest position, a rotation resistance can be felt. That means the mechanical stop is reached, and you should not use more force. Refer to the tables below for the configurable IR light beam angles and the number of full circles needed to change to the preferred beam angles. Each full circle corresponds to a preset beam angle. For example, if you need to change CM80I8-1040's beam angle to 30 (178m), turn the beam angle selector Counter-clockwise 2 full circles. If you are at the narrowest angle (10 ) and prefer to turn to 24, turn 3 full circles clockwise. When done, install the waterproof cover. Example: Width Angle Distance X2 40 36 30 X2 Rotate direction Counter-clockwide Narrower Clockwide Wider Rotate direction Counter-clockwide Narrower Clockwide Wider CM80I8-1040 Full circle Beam angle Single mount Double mount Triple mount Distance(m) Width(m) Distance(m) Width(m) Distance(m) Width(m) 0 40 140 101.9 198.0 144.1 242.5 176.5 1 36 150 97.5 212.1 137.9 259.8 168.8 2 30 178 95.4 251.7 134.9 308.3 165.2 3 27 192 92.2 271.5 130.4 332.6 159.7 4 24 210 89.3 297.0 126.3 363.7 154.6 5 16 288 81.0 407.3 114.5 498.8 140.2 6 15 301 79.3 425.7 112.1 521.3 137.3 7 10 350 61.2 495.0 86.6 606.2 106.1 CM80I8-2040 Full circle Beam angle Single mount Double mount Triple mount Distance(m) Width(m) Distance(m) Width(m) Distance(m) Width(m) 0 40 170 123.7 240.4 175.0 294.4 214.3 1 36 175 113.7 247.5 160.8 303.1 197.0 2 29 210 108.6 297.0 153.6 363.7 188.1 3 27 221 106.1 312.5 150.1 382.8 183.8 4 20 280 98.7 396.0 139.6 485.0 171.0 8

Rotate direction Counter-clockwide Narrower Clockwide Wider Rotate direction Counter-clockwide Narrower CM80I8-4080 Full circle Beam angle Single mount Double mount Triple mount Distance(m) Width(m) Distance(m) Width(m) Distance(m) Width(m) 0 80 80 134.3 113.1 189.9 138.6 232.5 1 77 83 132.0 117.4 186.7 143.8 228.7 2 74 85 128.1 120.2 181.2 147.2 221.9 3 66 89 115.6 125.9 163.5 154.2 200.2 4 63 92 112.8 130.1 159.5 159.3 195.3 5 60 95 109.7 134.4 155.1 164.5 190.0 6 55 100 104.1 141.4 147.2 173.2 180.3 7 52 105 102.4 148.5 144.8 181.9 177.4 8 50 109 101.7 154.1 143.8 188.8 176.1 9 45 115 95.3 162.6 134.7 199.2 165.0 10 40 120 87.4 169.7 123.5 207.8 151.3 CM80I8-90120 Full circle Beam angle Single mount Double mount Triple mount Distance(m) Width(m) Distance(m) Width(m) Distance(m) Width(m) 0 120 60 207.8 84.9 293.9 103.9 360.0 1 105 65 169.4 91.9 239.6 112.6 293.4 2 90 70 140.0 99.0 198.0 121.2 242.5 Clockwide Wider 9

Select a position at the installation site. e.g., under a hanging roof. You can use the alignment sticker and start drilling a hole on the roof. Apply the included grip sticker to the U bracket. 10

Hammer the anchor in (user supplied, M6 anchors are recommended). Secure the U bracket to it, such as securing it using the bolt on a threaded pole. M6 anchor Secure the illuminator to bracket using the hex socket screws. 11

You will need to turn on both the partner camera and illuminator to precisely match the illuminated area with the camera's field of view. If necessary, adjust the beam angle again. Turn the illuminator toward the FOV of the partner camera, shift the tilt angle, and then tighten the screw and the rear cover to secure the illuminator. 12

Cable Pinouts Name Color Gauge Description V+ Red (20AWG) Power input V- Black (20AWG) 12~24V DC±10% 24V AC±10% (50~60Hz), (14.5VDC current controlled) DI+ Green (26AWG) LED ON/OFF control * Dry contact Logic level 1(Open) = LED off Logic level 0(Close to GND) = LED on * Wet contact Logic level 1: 4V~40 V = LED off Logic level 0: 0.8V MAX = LED on DI- Yellow (26AWG) Ground DO+ Purple (26AWG) Light sensor status output 1. Open = Day 2. Short = Night (300 lux for IR ON) DO- Blue (26AWG) Ground RS485+ Orange (26AWG) RS485 interface control RS485- Brown (26AWG) 13

Coordination with Cameras via the DI and DO Pins +3.3V +3.3V R R R DI+ Switch GND GND GND DI- +3.3V R Fuse/50mA DO+ External power source GND GND DO- NO NC Relay Camera DI pins IR LED ON/OFF control (Green & Yellow wires) This mode means that CaMate illuminator On/Off control is triggered by camera or other alarm system. User can decide using the appropriate dry/wet contacts depending on wiring condition. DI+: Green = TTL + voltage DI-: Yellow = TTL voltage (GND) * Dry contact Logic level 1 (Open) = LED off Logic level 0 (Close to GND) = LED on * Wet contact Logic level 1: 4V~40 V = LED off Logic level 0: 0.8V MAX = LED on 14

Light sensor status output (Purple & Blue wires) This mode means that camera Day/Night mode switching is coordinated with and is triggered by the illuminator's light sensor via the DO(Digital output) connection (connected to the camera's DI pins). Users can configure the camera configuration to control the corresponding illuminator On/Off status. DO+: Purple= Open drain output, 45V Max. (current must be under 100mA) DO-: Bule = GND Light sensor status output 1. Open = Day 2. Short = Night (lower than 300 lux for IR to turn ON) Stand-alone illuminator mode This mode means that the illuminator's On/Off control is triggered by its light sensor, in the case, the default wiring is connecting the green wire with purple wire. Some cameras have related settings that need the inter-connection with the illuminator. For example, some cameras come with an IR cut filter that need to be turned off when entering night mode; or, automatically turn on the adjacent illuminator when entering night mode. 15

This page is intentionally left blank. 16