Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

Similar documents
WLL 170 Photoelectric switches with fibre-optic cable, red light, manual sensitivity adjustment -- DC. Dimensional drawing R1.6 2-R

WT190T: The convenient, reliable proximity switch precisely the right one for challenging applications

W 2: Sub-Miniature Photoelectric Switch Range: Super-Small and Powerful

Contrast scanners detect the little differences

W 250: Compact photoelectric switch series for a broad range of applications

V 12-2 Miniature photoelectric switches: innovations in M12 housings

W 280: Powerful sensors for standard applications

W 2: Subminiature photoelectric switch series: extremely small and extremely strong

SICK laser competence in photoelectric switches

suppression, insensitive to optical interference, sensor E photoelectric switch, areas Zone 2 (gas) and Zone 22 (non-conductive dust).

WL 4-2 Photoelectric reflex switches, red light, dark-switching -- DC

V 18 Laser No frills performance: long ranges, high speeds with precision

W27-3: The all-rounder: robust, powerful, very wide range of applications

W 23-2: Focussing on what is essential and economic

Miniature photoelectric switches series W4-3: The efficient space savers

V 18 Laser No frills performance: long ranges, high speeds with precision

W 150: Miniature photoelectric switch series with completely integrated electronics

CS Colour sensors: When it s the colour that counts

MH 15: Short housing, clever mounting for smart solutions

Product description. At a glance. performance in a metal housing coating available Precise autocollimation optics. sensors

Online data sheet VT12T-2P410 V12-2 CYLINDRICAL PHOTOELECTRIC SENSORS

Contrast Sensors. SICK The pioneer in contrast sensors for more than 60 years

W 27-3: The all-rounder: robust, powerful, very wide range of applications

W 27-3: The all-rounder: robust, powerful, very wide range of applications

W 140: Miniature Photoelectric Switch Series with Large Scanning Ranges

W140-2: Miniature Photoelectric Switch Series with Large Scanning Ranges

W 140-2: Miniature Photoelectric Switch Series with Large Scanning Ranges

W 160T: With the smallest LED light spot

MH15 Cylindrical Photoelectric Sensors

W 140-2: Miniature Photoelectric Switch Series with Large Scanning Ranges

VLL 18T; M 18 photoelectric switches, for LL 3 fibre-optic cables: economic, flexible, functional

DS 500/DT 500 Laser sensor measures distances to 18 m on black material in proximity mode

Product description. At a glance. IP 69K-rated cylindrical photoelectric sensors in M18 stainless steel housing Resistant to all common cleaning

W 23-2: Focussing on what is essential and economic

DS500/DT500 Laser sensor measures distances to 30 m on black material in proximity mode

Online data sheet VT12T-2N112 V12-2 CYLINDRICAL PHOTOELECTRIC SENSORS

Online data sheet. WTB190TL-P460 W190 Laser High Grade PRODUCT PORTFOLIO

W27-3: The all-rounder: robust, powerful, very wide range of applications

DATA SHEET. OD Precision. Displacement sensors for precise and comprehensive measurement tasks

PHOTOELECTRIC SENSORS. Online data sheet

DMH: Multidimensional sensors for a wide variety of height detection tasks

W 4-3 miniature photoelectric switch family: Efficient and space-saving

Online data sheet VTF18-4N1212 V18 CYLINDRICAL PHOTOELECTRIC SENSORS

Online data sheet WT34-B410 W34 PRODUCT PORTFOLIO

W12-3: More robust, more accurate, more intelligent

Online data sheet WSE9LC-3P2436A00 W9L-3

W4S-3 Inox Photoelectric Switch Family

Online data sheet WT34-V220 W34 PRODUCT PORTFOLIO

Online data sheet. WLG190T-P420 W190 Laser High Grade Glass PRODUCT PORTFOLIO

Online data sheet VL18-4N3112 V18 PRODUCT PORTFOLIO

DS500/DT500 Laser sensor measures distances to 30 m on black material in proximity mode

Online data sheet WS/WE260-R270 W260 PRODUCT PORTFOLIO

Online data sheet. WTR2-P521 ZoneControl PHOTOELECTRIC SENSORS

Online data sheet. WTB4S-3P1132V W4S-3 Inox MINIATURE PHOTOELECTRIC SENSORS

Online data sheet. RT-P3221 ZoneControl PHOTOELECTRIC SENSORS

Online data sheet WT260-R260 W260 PRODUCT PORTFOLIO

DS 500/DT 500 Laser sensor measures distances to 18 m on black material in proximity mode

Online data sheet NT NT8 CONTRAST SENSORS

WFS Fork Sensors. Agile and flexible ideal mounting for labeling applications. P r o d u c t I n f o r m at i o n

Leuze electronic. 3 Series. Product description

Online data sheet WL260-S270 W260 PRODUCT PORTFOLIO

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Online data sheet NT NT6 CONTRAST SENSORS

QL55 Series Luminescence Sensor

LASER. Analog Laser Displacement Transducer. LAM Series. Key-Features: Content:

Electrical connection

LUT2 Luminescence scanner

Throughbeam photoelectric sensors. Dimensioned drawing. Transmitter/receiver Optical axis LED yellow 90 turning connector. Electrical connection

5-pole M12 connector. Connecting cable: cab-m12/5-g-2m. LED (red) for dirt accumulation indication

Phone: Fax: Web: -

D-LAS Series D-LAS2-... Design. D-LAS Series Laser Digital Light Barriers. Product name: Transmitter: D-LAS2-(aperture)*-T

General-Purpose Photoelectric Sensor

Ultrasonic sensors. Reliable on almost all surfaces. UT 20 from Page 548. UT 12 from Page 564. UT/UM 18 from Page 568

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Fibre-optic units SOE4

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Example: ZX-BGS-DS300P-2M ZX Series - Diffuse Background Suppression Type - Distance Settable, 300mm Sensing Distance, PNP - 2m Cable

Electrical connection

ON I T P ESCRI D L A IC N ECH T D M P P o s i t i o n F i n d e r

Laser light scanner with background suppression. Dimensioned drawing

Long Range Metal Body Sensor

E3S-CR62/67. Ideal for detecting transparent glass and plastic containers. Transparent bottle sensor. Features

A finger on the pulse of time

in one housing (3). The light beam is reflected by a reflector (4). The objects are detected by interruption of the light beam.

Fibre-optic sensors and cables

Distance sensors. System description. Distance measurement using triangulation

REMOTE SENSOR SERIES. Description

VISOR Color. Vision sensor for the most precise object detection. made in Germany HIGHLIGHTS OF THE VISOR COLOR

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

DB 12 B. Double Sheet Testing Unit. Phone: Fax: Web: -

Operating instructions Contrast sensor O5K / / 2016

Optical laser distance sensors. Dimensioned drawing

MLV40 Series Miniature Sensors

QL50 Luminescence Sensor

Online data sheet WL34-R230 W34 COMPACT PHOTOELECTRIC SENSORS

Distance sensors. System description. Distance measurement using triangulation

DB 112 B. Double Sheet Testing Unit TECHNICAL DESCRIPTION. en / We reserve the right to. make technical changes

Transcription:

WLL 0(T) Photoelectric switches Photoelectric switches with fibre-optic cable Proximity mode Photoelectric switches with fibre-optic cable Through-beam mode Photoelectric switches WLL 0(T), fibre-optic cables LL : flexible solutions with fibre-optic cable systems FFibre-optic sensors without baggage. Safe and simple switching: The combination of photoelectric switches WLL 0(T) and fibreoptic cables LL offers extremely simple handling and intelligent system options for a wide range of applications. For standard applications, but also for demanding applications such as detection of very small objects, recognition of colour marks or transparent materials. You choose: Suitable WLL 0(T) versions, optimised for various typical uses, are available WLL 0T with teach-in: This teach-in version simplifies handling: the switching threshold and switching hysteresis are automatically set, via a push button (Teach-in). Sender LED red or green light: Selects the most suitable emitted light for optimum detection of colour contrasts. WLL 0- with manual switching threshold adjustment: The cost-effective solution for all standard applications. WLL 0 High Speed: 0,000 switching operations per second - the optimum for high speed applications. WLL 0A with analogue output: For easy measurement and control. Large selection of suitable fibreoptic cables: Fibre-optic cable range LL. For WLL 0, there are around 0 LL versions, offering maximum flexibility and choice for your requirements. Typical uses for these WLL 0 / LL fibre-optic cable combinations: semiconductor industry, electronics assembly, packaging technology, handling and assembly systems, special-purpose machinery, construction and precision engineering. SENSICK CATALOGUE 0-0-00

WLL 0(T) n In pick-and-place systems, WLL 0(T) photoelectric switches with LL plastic fibre-optic cables are used in a wide variety of configurations to monitor the presence or position of minute objects. b Fibre-optic cables are widely used in the electronics industry. For example, fibre-optic cables with integrated 0 angle used for detecting contact pins in locations where space is restricted. v WLL 0(T) units with red or green transmission light and LL plastic fibreoptic cables for detecting print marks used to control labelling machines. m LL fibre-optic cables for special applications: here LL cables with Teflon jacket are the right choice for harsh environments (i.e. contact with acids, alkaline solutions, detergents or oils). 0-0-00 SENSICK CATALOGUE

WLL 0-, red light, manual sensitivity adjustment - DC Scanning range 0... 000 mm Through-beam mode Proximity mode Scanning distance 0... 0 mm Dimensional drawing. ø.. Sender LED red for standard applications anual sensitivity adjustment Simple installation and alignment.. ~0..... 0. 0.. ø.. 0.. Adjustments possible in ax SENS. 0 DLY L. D. Sender LED, installation of LL fibre-optic cable (sender fibre) Receiver, installation of LL fibre-optic cable (receiver fibre) Protective hood, can be raised at both ends ounting bracket, included with delivery (see Accessories) Connector Indication of correct fibre-optic cable mounting Indicator LED orange: lights up when switching output is active LED signal strength indicator green, lights up when light received < 0. or >. (switching threshold = ) Sensitivity scale 0 0 Sensitivity control (0 revolutions) Selector switch for delay: DLY (=) /, 0 ms fixed Selector switch: L. (light switching) / D. (dark switching) Connection type WLL0-N WLL0-P WLL0-N0 WLL0-P0 WLL0-N0 WLL0-P0 See chapter Accessories Connector,, -pin Connector,, -pin Fibre-optic cable Tip adapters ounting systems x 0. mm² brn blu blk L+, -pin, -pin NC 0 SENSICK CATALOGUE 0-0-00

WLL 0- Technical data WLL0- N N0 N0 P P0 P0 Operating distance 0... 0 mm ) Fibre-optic cable (proximity system): LL-DK0 Adjustment of operating distance Poti, 0 revolutions ) Scanning range max. typ. Fibre-optic cable (through-beam system) Operating range, recommended Fibre-optic cable (through-beam system) 0...,000 mm LL-TB0 and tip adapter LL-TA0 0... 00 mm LL-TB0 Sensitivity adjustment Poti, 0 revolutions ) Light source, light type LED, red light, 0 nm ) Light spot diameter Angle of dispersion Depends on scanning range Supply voltage V s 0... 0 V DC ) Residual ripple 0 % ) Power consumption 0 ma ) Switching outputs Switching mode Output current I a max Approx. see LL fibre-optic data NPN: open collector: PNP: open collector: Light/dark switching, switchable 00 ma Response time 0. ms ) Switching frequency,000 Hz ) Time delay 0 ms fix, selectable by sliding switch Time type Off delay t Connection type Cable, Ø. mm, PVC, m ) VDE protection class Connector,, -pin Connector,, -pin Circuit protection V s connections reverse-polarity protected / In-/outputs short-circuit protected / Interference pulse suppression / Outputs overcurrent and short-circuit protected Enclosure rating IP 0) Ambient temperature operation - C... + C Ambient temperature storage -0 C... +0 C Weight Approx. 0 g Housing material ABS/PC ) Object with 0 % remission (based on standard white to DIN 0) ) Sensitivity scale 0 ) Average service life 00,000 h at T a = + C ) Limit values ) may not exceed or fall short of V s tolerances ) without load ) Signal transit time with resistive load ) with light/dark ratio : ) do not bend below 0 C 0) with correctly attached fibre-optic cable LL and closed protection hood Function diagram for WLL 0- WLL 0- Orange LED display: lights up when switching output is active. Dependent on setting of light/ dark selector switch...0 0. Light received >. Switching threshold () Light received < 0. Green LED display: lights up when light received is < 0. or >. (based on the switching threshold, switching threshold = ). Switching output (light-switching) t 0 ms Switching output (dark-switching) Indicator LED, green Ordering information Type Order no. WLL0-N 0 WLL0-N0 0 WLL0-N0 0 WLL0-P 0 WLL0-P0 0 WLL0-P0 0 0-0-00 SENSICK CATALOGUE

WLL 0-, green light, manual sensitivity adjustment - DC Scanning range 0... 00 mm Through-beam mode Proximity mode Scanning distance 0... mm Dimensional drawing. ø.. Sender LED green for standard applications and print mark recognition anual sensitivity adjustment Simple installation and alignment.. ~0..... 0. 0.. ø.. 0.. Adjustments possible in ax SENS. 0 DLY L. D. Sender LED, installation of LL fibre-optic cable (sender fibre) Receiver, installation of LL fibre-optic cable (receiver fibre) Protective hood, can be raised at both ends ounting bracket, included with delivery (see Accessories) Connector Indication of correct fibre-optic cable mounting Indicator LED orange: lights up when switching output is active LED signal strength indicator green, lights up when light received < 0. or >. (switching threshold = ) Sensitivity scale 0 0 Sensitivity control (0 revolutions) Selector switch for delay: DLY (=) /, 0 ms fixed Selector switch: L. (light switching) / D. (dark switching) Connection type WLL0-N WLL0-P WLL0-N0 WLL0-P0 WLL0-N0 WLL0-P0 See chapter Accessories Connector,, -pin Connector,, -pin Fibre-optic cable Tip adapters ounting systems x 0. mm² brn blu blk L+, -pin, -pin NC SENSICK CATALOGUE 0-0-00

WLL 0- Technical data WLL0- N N0 N0 P P0 P0 Operating distance 0... mm ) Fibre-optic cable (proximity system): LL-DK0 Adjustment of operating distance Poti, 0 revolutions ) Scanning range max. typ. Fibre-optic cable (through-beam system) Operating range, recommended Fibre-optic cable (through-beam system) 0...,00 mm LL-TB0 and tip adapter LL-TA0 0... 0 mm LL-TB0 Sensitivity adjustment Poti, 0 revolutions ) Light source, light type LED, green light, 0 nm ) Light spot diameter Angle of dispersion Depends on scanning range Supply voltage V s 0... 0 V DC ) Residual ripple 0 % ) Power consumption 0 ma ) Switching outputs Switching mode Output current I a max Approx. see LL fibre-optic data NPN: open collector: PNP: open collector: Light/dark switching, switchable 00 ma Response time 0. ms ) Switching frequency,000 Hz ) Time delay 0 ms fix, selectable by sliding switch Time type Off delay t Connection type Cable, Ø. mm, PVC, m ) VDE protection class Connector,, -pin Connector,, -pin Circuit protection V s connections reverse-polarity protected / In-/outputs short-circuit protected / Interference pulse suppression / Outputs overcurrent and short-circuit protected Enclosure rating IP 0) Ambient temperature operation - C... + C Ambient temperature storage -0 C... +0 C Weight Approx. 0 g Housing material ABS/PC ) Object with 0 % remission (based on standard white to DIN 0) ) Sensitivity scale 0 ) Average service life 00,000 h at T a = + C ) Limit values ) may not exceed or fall short of V s tolerances ) without load ) Signal transit time with resistive load ) with light/dark ratio : ) do not bend below 0 C 0) with correctly attached fibre-optic cable LL and closed protection hood Function diagram for WLL 0- WLL 0- Orange LED display: lights up when switching output is active. Dependent on setting of light/ dark selector switch...0 0. Light received >. Switching threshold () Light received < 0. Green LED display: lights up when light received is < 0. or >. (based on the switching threshold, switching threshold = ). Switching output (light-switching) t 0 ms Switching output (dark-switching) Indicator LED, green Ordering information Type Order no. WLL0-N 0 WLL0-N0 0 WLL0-N0 0 WLL0-P 0 WLL0-P0 0 WLL0-P0 0 0-0-00 SENSICK CATALOGUE

WLL 0-, High Speed - DC Scanning range 0... 00 mm Through-beam mode Proximity mode Scanning distance 0... mm Dimensional drawing. ø.. High speed 0,000/sec., for extremely fast processes Sender LED red anual sensitivity adjustment Time delay 0 ms for signal extension... ~0 ø.. 0...... 0. 0.. Adjustments possible in ax SENS. 0 DLY L. D. Sender LED, installation of LL fibre-optic cable (sender fibre) Receiver, installation of LL fibre-optic cable (receiver fibre) Protective hood, can be raised at both ends ounting bracket, included with delivery (see Accessories) Connector Indication of correct fibre-optic cable mounting Indicator LED orange: lights up when switching output is active LED signal strength indicator green, lights up when light received < 0. or >. (switching threshold = ) Sensitivity scale 0 0 Sensitivity control (0 revolutions) Selector switch for delay: DLY (=) /, 0 ms fixed Selector switch: L. (light switching) / D. (dark switching) Connection type WLL0-N WLL0-P WLL0-N0 WLL0-P0 WLL0-N0 WLL0-P0 See chapter Accessories Connector,, -pin Connector,, -pin Fibre-optic cable Tip adapters ounting systems x 0. mm² brn blu blk L+, -pin, -pin NC SENSICK CATALOGUE 0-0-00

WLL 0- Technical data WLL0- N N0 N0 P P0 P0 Operating distance 0... mm ) Fibre-optic cable (proximity system): LL-DB0 Adjustment of operating distance Poti, 0 revolutions ) Scanning range max. typ. Fibre-optic cable (through-beam system) Operating range, recommended Fibre-optic cable (through-beam system) 0...,00 mm LL-TB0 and tip adapter LL-TA0 0... 0 mm LL-TB0 Sensitivity adjustment Poti, 0 revolutions ) Light source, light type LED, Red light, 0 nm ) Light spot diameter Angle of dispersion Depends on scanning range Supply voltage V s 0... 0 V DC ) Residual ripple 0 % ) Power consumption 0 ma ) Switching outputs Switching mode Output current I a max Approx. see LL fibre-optic data NPN: open collector: PNP: open collector: Light/dark switching, switchable 00 ma Response time 0 µs ) Switching frequency 0,000 Hz ) Time delay 0 ms fix, selectable by sliding switch Time type Off delay t Connection type Cable, Ø. mm, PVC, m ) VDE protection class Connector,, -pin Connector,, -pin Circuit protection V s connections reverse-polarity protected / In-/outputs short-circuit protected / Interference pulse suppression / Outputs overcurrent and short-circuit protected Enclosure rating IP 0) Ambient temperature operation - C... + C Ambient temperature storage -0 C... +0 C Weight Approx. 0 g Housing material ABS/PC ) Object with 0 % remission (based on standard white to DIN 0) ) Sensitivity scale 0 ) Average service life 00,000 h at T a = + C ) Limit values ) may not exceed or fall short of V s tolerances ) without load ) Signal transit time with resistive load ) with light/dark ratio : ) do not bend below 0 C 0) with correctly attached fibre-optic cable LL and closed protection hood Function diagram for WLL 0- WLL 0- Orange LED display: lights up when switching output is active. Dependent on setting of light/ dark selector switch...0 0. Light received >. Switching threshold () Light received < 0. Green LED display: lights up when light received is < 0. or >. (based on the switching threshold, switching threshold = ). Switching output (light-switching) t 0 ms Switching output (dark-switching) Indicator LED, green Ordering information Type Order no. WLL0-N 0 WLL0-N0 0 WLL0-N0 0 WLL0-P 0 WLL0-P0 0 WLL0-P0 0 0 0-0-00 SENSICK CATALOGUE

WLL 0A, red light, analogue DC Scanning range 0...00 mm Through-beam systems Dimensional drawing R. -R. Scanning distance 0...00 mm. Proximity systems Analogue output voltage... V Large range of suitable LL fibre-optic cables Ideal for more complex requirements, e.g. positioning tasks, turbidity/transmission measurement, contrast resolution. ø. approx. 00. 0 R. 0. 0 approx. 0 0... Adjustments possible WLL 0A-V WLL 0A-V0 WLL 0A-V0 in ax SENS ms 0 ms Sender LED, installation of LL fibre-optic cable (sender fibre) Receiver, installation of LL fibre-optic cable (receiver fibre) Protective hood: can be raised at both ends, removable ounting bracket, included (see Accessories) : analogue output with saturation ( V) LED signal strength indicator, green: lights up when light received Sensitivity scale, min./max. = 0 Sensitivity control (min./max. = revolutions) Selector switch for analogue output response time Connection types WLL 0A-V0 WLL 0A-V0 WLL 0A-V See chapter Accessories Cables and connectors ounting systems Fibre-optic cables -pin, brn blu blk... V -pin, brn blu blk wht... V NC l mm brn blu blk L+... V SENSICK CATALOGUE 0-0-00

WLL 0A Technical data WLL 0T- V V 0 V0 Suitable fibre-optic cable LL plastic fibre-optic cables Scanning range ) Depends on fibre-optic cable used Recommended operating ranges ) max. 0...00 mm (through-beam syst.) (with tip adapters 0...00 mm) Recommended operating distance ) max. 0...00 mm ) (proximity system) Light source ), light type LED, visible red light Light spot diameter of LL Depends on scanning range Disp. angle of LL fibre-optic cable Approx. ) Supply voltage V ) S 0...0 V DC Ripple ) 0% Current consumption ) 0 ma Analogue output Voltage output... V V = no light received V = saturation Load current (max.) 0 ma Output resistance (Ri) Ω Load resistance kω (recommended) Response time, selectable ) ms/0 ms Sensitivity, adjustable Potentiometer, turns ) Connection types cable 0) PVC, m; x 0. mm, l.0 mm plug, -pin plug, -pin Cable extension max. 00 m; signal loss to be expected Circuit protection ) A, C, D VDE protection class Enclosure rating IP 0 Ambient temperature T A Operation C...+ C Storage 0 C...+0 C Weight with cable Approx. 0 g with plug Approx. 0 g Housing material ABS ) See Accessories; selection table for LL fibre-optic cables ) Object with 0 % remission (based on standard white to DIN 0) ) Average service life 00,000 h at T A = + C ) Deviations, see data for LL ) Limit values ) ay not exceed or fall short of V S tolerances ) Without load ) Delay time: change in received light/ change in analogue output, (0 % of upper range value) ) Scale 0 0) Do not bend below 0 C ) A = V S connections reverse-polarity protected C = Interference pulse suppression D = Outputs overcurrent and shortcircuit protected Analogue output (V) WLL 0A, analogue, typical curves V SENS. max. WLL 0A LL-TB0 Analogue output (V) V SENS. max. WLL 0A LL-DB0 Order information Type WLL 0A-V WLL 0A-V0 WLL 0A-V0 Order no. 0 0 0 0 00 SENS. / SENS. / 0 (mm) 00 00 00 00 000 Scanning range (mm) 0 (mm) 0 0 0 0 Scanning distance (mm) 0-0-00 SENSICK CATALOGUE

WLL 0T, red light, teach-in DC Scanning range 0...0 mm Through-beam systems Dimensional drawing R. -R. Scanning distance 0...00 mm. Proximity systems Red sender LED For standard applications and mark recognition Easy alignment and commissioning by teach-in. ø. approx. 00. 0 R. 0. 0 approx. 0 0... Adjustments possible WLL 0T-P WLL 0T-P0 WLL 0T-N WLL 0T-P 0 WLL 0T-N 0 DLY L. D. SET RUN 0 WLL 0T-N0 0 LED sender, installation of LL fibre-optic cable (sender fibre) Receiver, installation of LL fibre-optic cable (receiver fibre) Protective hood, can be raised at both ends, removable ounting bracket, included (see Accessories) Orange LED indicator, lights up when switching output is active Green LED reception indicator, lights up when light received is < 0. or >. (switching threshold = ) delay selector switch: DLY (on)/, 0 ms fixed Selector switch: L. (light-switching)/ D. (dark-switching) Operating mode selector switch: SET (Teach-in mode)/ RUN (sensor mode) Teach-in push button Connection types WLL 0T-P 0 WLL 0T-N 0 WLL 0T-P0 WLL 0T-N0 WLL 0T-P WLL 0T-N See chapter Accessories Cables and connectors ounting systems Fibre-optic cables -pin, -pin, NC l mm brn blu blk L+ SENSICK CATALOGUE 0-0-00

WLL 0T Technical data WLL 0T- P P 0 P0 N N 0 N0 Suitable fibre-optic cable LL plastic fibre-optic cables Scanning range Dependent on fibre-optic cable used Recommended operating ranges 0...0 mm (through-beam system) (with auxiliary lens 0...00 mm) Recommended operating distance 0...00 mm ) (proximity system) Sensitivity setting Automatically, by Teach-in button ode switch at pos. SET ) ode selector switch position SET Teach-in button active position RUN Teach-in button inactive ) Light source ), light type LED, visible red light Light spot diameter LL Dependent on scanning range Dispersion angle LL fibre-optic cable Approx. ) Supply voltage V ) S 0...0 V DC Ripple ) 0% Current consumption ) 0 ma Switching outputs PNP: open collector: NPN: open collector: Output current I A max. 00 ma Light receiver, switching type Dark-/light-switching ) Response time 0) 0. ms Switching frequency max. ) 000/s Time delay t ( delay) 0 ms fix, selectable by sliding switch Connection types cable ) PVC, m; x 0. mm, l.0 mm plug, -pin plug, -pin Circuit protection ) A, B, C, D VDE protection class Enclosure rating IP 0 Ambient temperature T A Operation C...+ C Storage 0 C...+0 C Weight with cable m Approx. 0 g with plug, -pin/-pin Approx. 0 g Housing material ABS ) Object with 0 % remission (based on standard white to DIN 0) ) Teach-in active ) Equipment in sensor mode ) Average service life 00,000 h at T A = + C ) See LL data for deviations ) Limit values ) ay not exceed or fall short of V S tolerances ) Without load ) By sliding switch 0) With light/dark ratio : without time delay ) With resistive load ) Do not bend below 0 C ) A = V s connections reverse-polarity protected B= Inputs/outputs reverse-polarity protected C = Interference suppression D= Outputs overcurrent and short-circuit protected Function diagram WLL 0T Standard WLL 0T in sensor mode Operating mode selector switch in RUN mode (after setting the switching threshold by means of Teach-in). Orange LED display: lights up if switching output is active. Dependent on setting of light/ dark selector switch. Green LED display: lights up if light received is < 0. or >. (based on the switching threshold, switching threshold = ). LED display in Teach-in mode: see Teach-in page...0 0. t 0 ms Light received >. Switching threshold () Light received < 0. Switching output (light-switching) Switching output (dark-switching) Order information Type WLL 0T-P WLL 0T-P 0 WLL 0T-P0 WLL 0T-N WLL 0T-N 0 WLL 0T-N0 Order no. 0 0 0 0 0 0 Indicator LED, green 0-0-00 SENSICK CATALOGUE

WLL 0T, green light, mark sensors DC Scanning range 0...0 mm Through-beam systems Dimensional drawing R. -R. Scanning distance 0... mm. Proximity systems Green sender LED Ideal for recognition of red marks, contrasts or parts Commissioning by teach-in. ø. approx. 00 approx. 0 0.... 0 R. 0. 0 Adjustments possible WLL 0T-P WLL 0T-P0 WLL 0T-N WLL 0T-P 0 WLL 0T-N 0 DLY L. D. SET RUN 0 WLL 0T-N0 0 LED sender, installation of LL fibre-optic cable (sender fibre) Receiver, installation of LL fibre-optic cable (receiver fibre) Protective hood, can be raised at both ends, removable ounting bracket, included in delivery (see Accessories) Orange LED indicator, lights up when switching output is active Green LED reception indicator, lights up when light received is < 0. or >. (switching threshold = ) delay selector switch: DLY (on)/, 0 ms fixed Selector switch: L. (light-switching)/ D. (dark-switching) Operating mode selector switch: SET (Teach-in mode)/ RUN (sensor mode) Teach-in push button Connection types WLL 0T-P 0 WLL 0T-N 0 WLL 0T-P0 WLL 0T-N0 WLL 0T-P WLL 0T-N See chapter Accessories Cables and connectors ounting systems Fibre-optic cables -pin, -pin, NC l mm brn blu blk L+ 0 SENSICK CATALOGUE 0-0-00

WLL 0T Technical data WLL 0T- P P 0 P 0 N N 0 N 0 Suitable fibre-optic cable LL plastic fibre-optic cables Scanning range Dependent on fibre-optic cable used Recommended operating ranges 0...0 mm (through-beam system) (with auxiliary lens 0...0 mm) Recommended operating distance 0... mm ) (proximity system) Sensitivity setting Automatically, by Teach-in button ode switch at pos. SET ) Additional fine alignment, manual Optional ) Black & white resolution ) grey levels ode selector switch position SET Teach-in button active position RUN Teach-in button inactive ) Light source ), light type LED, visible green light Light spot diameter LL Dependent on scanning range Dispersion angle LL fibre-optic cable Approx. ) Supply voltage V ) S 0...0 VDC Ripple ) 0 % Current consumption ) 0 ma Switching outputs PNP: open collector: NPN: open collector: Output current I A max. 00 ma Light receiver, switching type Dark/light switching 0) Response time ) 0. ms Switching frequency max. ) 000/s Time delay t ( delay) 0 ms fix, selectable by sliding switch Connection types cable ) PVC, m; x 0. mm, l.0 mm plug, -pin plug, -pin Circuit protection ) A, B, C, D VDE protection class Enclosure rating IP 0 Ambient temperature T A Operation C...+ C Storage 0 C...+0 C Weight with cable m Approx. 0 g with plug, -pin Approx. 0 g Housing material ABS ) Object with 0 % remission (based on standard white to DIN 0) ) Teach-in active ) With LL -DT0 proximity fibre-optic cable, scanning distance mm ) Equipment in sensor mode ) Average service life 00,000 h at T A = + C ) See LL data for deviations ) Limit values ) ay not exceed or fall short of V S tolerances ) Without load 0) By sliding switch ) With light/dark ratio : without time delay ) With resistive load ) Do not bend below 0 C ) A=V s connections reverse-polarity protected B = Inputs/outputs reverse-polarity protected C = Interference suppression D = Outputs overcurrent and shortcircuit protected Function diagram WLL 0T standard WLL 0T in sensor mode Operating mode selector switch in RUN mode (after setting the switching threshold by means of Teach-in). Orange LED display: lights up if switching output is active. Dependent on setting of light/ dark selector switch. Green LED display: lights up if light received is < 0. or >. (based on the switching threshold, switching threshold = ). LED display in Teach-in mode: see Teach-in page...0 0. t 0 ms Light received >. Switching threshold () Light received < 0. Switching output (light-switching) Switching output (dark-switching) Order information Type Order no. WLL 0T-P 0 WLL 0T-P 0 0 WLL 0T-P 0 0 0 WLL 0T-N 0 WLL 0T-N 0 0 WLL 0T-N 0 0 Indicator LED, green 0-0-00 SENSICK CATALOGUE

WLL 0T Photoelectric switches with fibre-optic cable, Teach-in Functions Teach-in button Sensitivity adjustment by pressing a button. No special photoelectric switch knowledge necessary. Only active when ODE selector switch is in the SET position (manipulation protection). Switching selector switch L.: light-switching. D.: dark-switching. Either in NPN or PNP. Connection type Either, -pin/-pin equipment plug or m connection cable. Teach-in mode selector switch Separate from other operating mode selector switches, therefore simple to operate, no double functions. SET : WLL 0T in manual Teach-in mode. Optimum switching point setting by simply pressing a botton (once or twice). RUN : The taught-in switching threshold and switching hysteresis are saved in the EEPRO. Accidental change of the taught-in parameter is not possible. After seconds the WLL 0T operates in the sensor mode. The saved Teach-in values are retained for an unlimited period of time even if the voltage is interrupted for a longer time. delay t off For switching output. Also switchable, 0 ms fixed. Enables the control unit to detect very short events. Protective hood Both sides can be opened up, easy to remove. Easy locking. Also used to check correct fibreoptic cable locking (protective hood cannot be shut otherwise). ounting system WLL 0T ounting by simply clipping onto profile mounting rail. (ounting bracket included in delivery). LED indicators orange, green Teach-in mode: Signalling Teach-in sequence Constantly flashing: Teach-in error Constantly lit: Teach-in OK. Sensor mode: Orange LED: switching output active Green LED: receiver signal >. or < 0.; (switching threshold = ). Sender LED: Either red or green LED (see selection table) Red LED: Ideal for all standard applications (high transmission power, large ranges), also for mark detection. Warning: not possible to detect red marks with red light. Green LED: Ideal for recognition of red marks. μ-prozessor controlled, with EEPRO: Permanent retention of taught-in switching threshold and hysteresis even if voltage is interrupted for a longer period of time. Snap-in connector for fibre-optic cable Fibre-optic cable mounting Release fibre-optic cable: snap closure in horizontal position. Insert the fibre-optic cable. Lock the fibre-optic cable: closure in vertical position. Removing fibre-optic cable Release the fibre-optic cable: put the snap closure in a horizontal position. Pull out the fibre-optic cable. Fibre-optic cable receptacle fibre-optic cable (sender). fibre-optic cable (receiver). Suitable fibre-optic cable: LL series plastic fibre-optic cable (see description of the many LL variants). SENSICK CATALOGUE 0-0-00

WLL 0T, Teach-in handling. Accurate sensitivity setting (by pressing button twice); WLL 0T Teach-in steps Positioning the object in the light path Proximity Through-beam Proximity Through-beam system system system system START Teach-in Parts in light path Remove parts from light path Reset: STOP Sensor mode anual Teach-in SET Press Teach-in button > s Press Teach-in button > s SET RUN RUN ode switch in SET position Press Teach-in button > sec Orange LED indicator lights Press Teach-in button > sec Green LED indicator lights ode switch in RUN position This operating mode is suitable for all applications: large ranges, precise switching points, low hysteresis, transparent objects and contrast marks. The WLL 0T automatically optimizes the switching threshold and hysteresis by means of a μ-processor and saves these values permanently in the EEPRO. No special experience with opto-electronic components is necessary. The Teach-in button is pressed twice. Applications: Through-beam system: All standard applications, even thin and transparent objects are detected. Proximity system: All standard applications, strong background interference, small or dark target objects, simple marks with contrast differences.. Accurate positioning of parts or switching positions (by pressing button once); WLL 0T Teach-in steps Positioning the object in the light path Proximity system Through-beam system START Teach-in Parts accurately positioned in light path Reset: STOP Sensor mode anual Teach-in SET Press Teach-in button > s SET RUN RUN ode switch in SET position Press Teach-in button>sec, orange LED indicator lights ode switch in RUN position This operating mode is particulary suitable for accurate positioning tasks. After positioning the object in the desired switching position, the WLL 0T automatically optimizes the switching threshold and hysteresis by means of a μ-processor and saves the values permanently in the EEPRO: No special experience with opto-electronic components is necessary. The Teach-in button is pressed once. Applications: Through-beam system: Accurate positioning of parts. Proximity system: Accurate positioning of parts, positioning of contrast marks. 0-0-00 SENSICK CATALOGUE