The spectral colours of nanometers

Similar documents
High accurate metrology on large surface areas with low reflectivity

Optotop. 3D Topography. Roughness (Ra opt, Rq opt, and Rz opt) Height Distribution. Porosity Distribution. Effective Contact Area

Fiber Optic Cables for the TopSens Series

Advanced 3D Optical Profiler using Grasshopper3 USB3 Vision camera

Surface Finish Measurement Methods and Instrumentation

FRESNEL LENS TOPOGRAPHY WITH 3D METROLOGY

Confocal chromatic sensors and confocal microscope Micrometer measurement of thickness, displacement, position

Development of a new multi-wavelength confocal surface profilometer for in-situ automatic optical inspection (AOI)

PRODUCT BROCHURE PRECITEC LR. Optical sensor for ultra-precision surfaces

OCT Spectrometer Design Understanding roll-off to achieve the clearest images

Technical Explanation for Displacement Sensors and Measurement Sensors

DIMENSIONAL MEASUREMENT OF MICRO LENS ARRAY WITH 3D PROFILOMETRY

Spatially Resolved Backscatter Ceilometer

Optical Characterization and Defect Inspection for 3D Stacked IC Technology

The Importance of Wavelengths on Optical Designs

Image Formation. Light from distant things. Geometrical optics. Pinhole camera. Chapter 36

Sensors & Applications Glass Industry. More Precision

Point Autofocus Probe Surface Texture Measuring Instrument. PF-60 technical report

1.6 Beam Wander vs. Image Jitter

TechNote. T001 // Precise non-contact displacement sensors. Introduction

Measurement of the Modulation Transfer Function (MTF) of a camera lens. Laboratoire d Enseignement Expérimental (LEnsE)

PROCEEDINGS OF SPIE. Automated asphere centration testing with AspheroCheck UP

Optical basics for machine vision systems. Lars Fermum Chief instructor STEMMER IMAGING GmbH

Commercial Relevance of Freeform Optics. Mario Ledig Vice President Technology

Point Spread Function. Confocal Laser Scanning Microscopy. Confocal Aperture. Optical aberrations. Alternative Scanning Microscopy

Instructions for the Experiment

ECEN 4606, UNDERGRADUATE OPTICS LAB

Exam 4. Name: Class: Date: Multiple Choice Identify the choice that best completes the statement or answers the question.

Nanonics Systems are the Only SPMs that Allow for On-line Integration with Standard MicroRaman Geometries

3D light microscopy techniques

Measurement of Surface Profile and Layer Cross-section with Wide Field of View and High Precision

Applications of Optics

Comparison of resolution specifications for micro- and nanometer measurement techniques

attocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G

Ron Liu OPTI521-Introductory Optomechanical Engineering December 7, 2009

Vixar High Power Array Technology

Laser Speckle Reducer LSR-3000 Series

A 3D Profile Parallel Detecting System Based on Differential Confocal Microscopy. Y.H. Wang, X.F. Yu and Y.T. Fei

Exercise 8: Interference and diffraction

Sensitive measurement of partial coherence using a pinhole array

CS 443: Imaging and Multimedia Cameras and Lenses

Transmission Electron Microscopy 9. The Instrument. Outline

WaveMaster IOL. Fast and accurate intraocular lens tester

Optical Coherence: Recreation of the Experiment of Thompson and Wolf

APPLICATIONS FOR TELECENTRIC LIGHTING

nanovea.com PROFILOMETERS 3D Non Contact Metrology

Improving the Collection Efficiency of Raman Scattering

OPAL. SpotOptics. AUTOMATED WAVEFRONT SENSOR Single and double pass O P A L

Bringing Answers to the Surface

Performance Factors. Technical Assistance. Fundamental Optics

WaveMaster IOL. Fast and Accurate Intraocular Lens Tester

a) How big will that physical image of the cells be your camera sensor?

Chapter 25. Optical Instruments

Parallel Mode Confocal System for Wafer Bump Inspection

Optics: An Introduction

IMAGE SENSOR SOLUTIONS. KAC-96-1/5" Lens Kit. KODAK KAC-96-1/5" Lens Kit. for use with the KODAK CMOS Image Sensors. November 2004 Revision 2

Understanding Optical Specifications

THE WASATCH ADVANTAGE

Speed and Image Brightness uniformity of telecentric lenses

Confocal Imaging Through Scattering Media with a Volume Holographic Filter

SpotOptics. The software people for optics OPAL O P A L

EE-527: MicroFabrication

The Henryk Niewodniczański INSTITUTE OF NUCLEAR PHYSICS Polish Academy of Sciences ul. Radzikowskiego 152, Kraków, Poland.

1/8 m GRATING MONOCHROMATOR

ii) When light falls on objects, it reflects the light and when the reflected light reaches our eyes then we see the objects.

Opto Engineering S.r.l.

Supplementary Figure 1. Effect of the spacer thickness on the resonance properties of the gold and silver metasurface layers.

Guide to SPEX Optical Spectrometer

COLOUR INSPECTION, INFRARED AND UV

Coherence radar - new modifications of white-light interferometry for large object shape acquisition

Speckle free laser projection

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

TOP 200. Telescopic Optical Probe for Radiance and Luminance Measurements. Two Global Leaders. One Complete Solution.

Test Review # 8. Physics R: Form TR8.17A. Primary colors of light

StockOptics. CATALOG 2018 Europe

Handbook of Optical Systems

SMART LASER SENSORS SIMPLIFY TIRE AND RUBBER INSPECTION

Mirrors and Lenses. Images can be formed by reflection from mirrors. Images can be formed by refraction through lenses.

Variable microinspection system. system125

Application Note. Thickness measurement with two sensors

Near-field optical photomask repair with a femtosecond laser

Scanning Electron Microscopy SEM. Warren Straszheim, PhD MARL, 23 Town Engineering

Wuxi OptonTech Ltd. Structured light DOEs without requiring collimation: For surface-emitting lasers (e.g. VCSELs)

INSTRUCTION MANUAL FOR THE MODEL C OPTICAL TESTER

Fabrication Methodology of microlenses for stereoscopic imagers using standard CMOS process. R. P. Rocha, J. P. Carmo, and J. H.

Chapter 1. Basic Electron Optics (Lecture 2)

Some of the important topics needed to be addressed in a successful lens design project (R.R. Shannon: The Art and Science of Optical Design)

Laser Telemetric System (Metrology)

Microscopic Structures

Aperture and Digi scoping. Thoughts on the value of the aperture of a scope digital camera combination.

Microscopy: Fundamental Principles and Practical Approaches

ADALAM Sensor based adaptive laser micromachining using ultrashort pulse lasers for zero-failure manufacturing D2.2. Ger Folkersma (Demcon)

How-to guide. Working with a pre-assembled THz system

Investigation of an optical sensor for small angle detection

LENSES. INEL 6088 Computer Vision

Imaging Systems Laboratory II. Laboratory 8: The Michelson Interferometer / Diffraction April 30 & May 02, 2002

Testing Aspheric Lenses: New Approaches

Tutorial Zemax Introduction 1

7x P/N C1601. General Description

HIGH-RESOLUTION FIBER-COUPLED INTERFEROMETRIC POINT SENSOR FOR MICRO- AND NANO-METROLOGY. Markus Schake, Markus Schulz and Peter Lehmann ABSTRACT

Transcription:

Reprint from the journal Mikroproduktion 3/2005 Berthold Michelt and Jochen Schulze The spectral colours of nanometers Precitec Optronik GmbH Raiffeisenstraße 5 D-63110 Rodgau Phone: +49 (0) 6106 8290-14 Fax: +49 (0) 6106 8290-26 E-Mail: info@precitec-optronik.de Internet: www.precitec-optronik.de Reprint from the journal Mikroproduktion 3/2005 1

Reprint from the journal Mikroproduktion 3/2005 Berthold Michelt and Jochen Schulze The spectral colours of nanometers Contactless metrology becomes increasingly important for in-line or postprocess production quality control. Automotive industry, semiconductor industry, and manufacturers) of microsystems and sophisticated components built from glass and plastics need fast and accurate measurements of small structures, surface topography, and layer thickness. Typically, a lateral resolution of a few microns is demanded. The accuracy of the distance measured between the target and a reference plane usually needs to be better than 0,1 µm. Obviously, only optical systems are capable to cope with such demands. Principle of CHRocodile optical sensors For most industrial applications mentioned above the chromatically coded distance detection method turned out to be very well suited. That method takes advantage from a lens error commonly known as chromatic aberration: the axial position of the focal point of an uncorrected lens depends on the color (wavelength) of the light to be focussed. In the visible spectral region, the focal distance for blue light is minimal while it is maximal for red light. The focal points of other colors are located in between according to the row: red, orange, yellow, green, blue, violet. Depending on the distance of the target from the focusing lens, light of just a very small wavelength region 1 is focused on the target s surface (Fig. 1). All other spectral components of the light source are illuminating a much wider area of the surface. Figure 1. Principle of the chromatically encoded confocal measurement The focusing lens is also used to receive the backscattered light from the target s surface and to focus it into an optical fiber. Due to that confocal arrangement, light having the wavelength 1 is focused to the front of the fiber and enters it without clipping. All other spectral components are spread on a much bigger area. As a consequence, the light fed through the fiber to a spectrometer is almost Reprint from the journal Mikroproduktion 3/2005 2

monochromatic, it s wavelength 1 being a chromatic code about the axial position of the backscattering surface of the target. Therefore, the wavelength scale of the spectrometer can be calibrated vs. the distance to the scattering surface. Using optical probes with a high numeric aperture allows for measuring polished, rough, highly reflective or opaque surfaces, at a slope of up to e.g. 30 to the probe s optical axis (limited by the numerical aperture N a =sin α). As the measurement is carried out by using only the perfectly focused part of the reflected light, the effective measuring spot can be kept very small, yielding a lateral resolution of up to 2µm. Different from many other optical measuring principles, the above described measuring principle tolerates shadowing effects, caused by edges or holes with high aspect ratio. Furthermore it reduces the unavoidable measurement errors of triangulating and confocal measuring principles, which are caused by speckle effects and constitute a strong physical limitation to measuring accuracy, to a minimum by usage of a short coherent light source and high numerical observation aperture. The accuracy of distance measurement also depends on the scattering properties of the target surface. Highly absorbing materials and rough or tilted surfaces may reduce the amount of reflected light entering the optical probe reducing also the signal to noise ratio significantly. That may be compensated to some extent by increasing the exposure time and/or by the use of extremely bright illumination sources. The CHRocodile X - systems are designed to allow an unsurpassed measuring rate of 14 khz for almost all technical surfaces without substantial loss of accuracy. Alternative systems like triangulators (T), conoscopes (C), and cameras operating in autofocus arrangements (A) are suffering from system-inherent disadvantages like comparatively large probe spot size, beam clipping effects and speckle induced failures (T), increased influence of residual stray light effects of the target surface (T, C), comparatively large dimensions of the sensor, and loss of speed due to mechanical closed loop control components (A). Applications The quality of printed matter significantly depends on the volume of gravure cells on nip rolls. The CHRocodile system allows the measurement of the dimensions of the gravure cells with an acceptable uncertainty of a few percent (Fig. 2). Figure 2. Topography of a nip roll Reprint from the journal Mikroproduktion 3/2005 3

Lens production systems need accurate information on the central lens thickness. Chromatically coded systems (Fig. 3) are perfectly suited to generate the required accuracy. Figure 3. Measurement setup for measuring the central thickness of lenses The thickness of transparent layers can be measured interferometically with an uncertainty of less than 10 nm. The thickness of multilayers can also be analyzed. High resolution dimensional control is mandatory for microproduction systems. As an example, Fig. 4 displays the topography of a microlens array. CHR systems are also suited for industrial use such as in-line detection of small cracks in injection valves and for height measurements on saw wafers which are produced by the dicing technique. Figure 4. Topography of a microlens array Chromatically coded high resolution measuring sensors for distance, topography and layer thickness are widely used in the industrial environment. They are utilized as stand-alone sensors or integrated in high precision measuring machines. They are easy to operate and are extraordinary insensitive against surrounding stray light, temperature influence, and speckle phenomena. Reprint from the journal Mikroproduktion 3/2005 4

Contact: Dr.-Ing. Jochen Schulze Precitec Optronik GmbH Raiffeisenstraße 5 D-63110 Rodgau Phone: +49 (0) 6106 8290-14 Fax: +49 (0) 6106 8290-26 E-Mail: j.schulze@precitec-optronik.de Internet: www.precitec-optronik.de Reprint from the journal Mikroproduktion 3/2005 5