POWERBOX Defense Line 1200 DBA Series 1200W AC/DC Conduction Cooled Manual. 2. Features. 1. Introduction

Similar documents
POWERBOX Defense Line 1200 DBA Series 1200W AC/DC Conduction Cooled. Preliminary

PST22 Standard product

XSOLO ULTRA-COMPACT, HIGH-EFFICIENCY 500 W AND 1000 W SINGLE OUTPUT POWER SUPPLIES

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

solo Ultra-high efficiency 1U size Xsolo Single Output Power Supply 500W W 2 FEATURES APPLICATIONS INCLUDE

PST21B Standard product

ECC100 Series. -40 ºC to +75 ºC Operation. 100 W - Baseplate Cooled. High Efficiency Resonant Topology. Screw Terminals Available.

Low Profile. 3 Year Warranty

Model Vnom Power Description Set Point Dynamic Vtrim Imax Remote Power (V) (W) Adjust Range (V) Range (V) (A) Sense Good

CCH400 & CCH600 Series

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Model Vnom Power Description Set Point Dynamic Vtrim Imax Remote Power (V) (W) Adjust Range (V) Range (V) (A) Sense Good

Output Voltage* (nom.)(adjustable)

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

C B. Models. Models 2MOPP

DC-DC CONVERTER HFBC60-xxW/O

420 W High Line Output Power. Rugged Industrial Construction. -40 C to +70 C Operation. 5 V Standby. Screw Terminals. SEMI F47 Compliant

Industrial Serie +600S

CLP0205 Open Frame Power Supply Vac input; 5Vdc output; 200W Output Power; 0.25A stdby

LDC240 Series is a single phase, ultra compact DIN Rail Switching Power Supply with active PFC, ideal for many applications.

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

LDC480 Series is a single phase, extremely compact Power Supply with active PFC specially designed for space sensitive and demanding applications.

CLP0112 Open Frame Power Supply Vac input; 12Vdc output; 150W Output Power

CLP0224 Open Frame Power Supply Vac input; 24Vdc output; 200W Output Power

Features. Regulated Converters. RACM40 40 Watt Enclosed & Open Frame Case Style Single Output RACM40- S / - AC/DC Converter.

Industrial PSU with universal input voltage range ( VAC line to line) and configurable output voltage. North America

TB65 65W Single Output Test and Measurement/Industrial Series

CB Scheme UL508 UL ATEX II3G

X Series Data Sheet 375, 500 Watt AC-DC and DC-DC DIN-Rail Converters

ABC400 Series is a compact and efficient series of AC-DC open frame power supplies suited for telecom, datacom and many other applications.

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Note1: Max Cap Load is tested at minimum input and full resistive load. Connections (3) Case Style (1)

Military (Airborne, ground-fix, shipboard), Ruggedized, Telecom, Industrial

General. Environmental. EMC & Safety

LDW240 Series are single, two or three phase DIN Rail Switching Power Supplies.

Features. Regulated Converter RACM Watt Enclosed & Open Frame Case Style Single Output RACM65- S / - AC/DC Converter.

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Electrical Specifications. Adjustment range Main output ± 5% Total regulation (line and load) ± 2.0% ± 5.0% Turn-on 120 Vac Input 2.0 s max.

1500W Programmable Single Output AK V. 48V Rated Current. 31.3A Current Range 100A. 0~31.3A Rated Power 0~100A 1500W

General. Environmental. EMC & Safety

Series AM50E-NZ 50 Watt DC-DC Converter

VISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective Approved By A 11/11/13 Specification Release S. Sadot A1 14/01/14 Update ope

Industrial Applications Telecom Daracom

3000W Single Output Power Supply AK V 24V 250A 200A 125A 0 ~ 250A 0 ~ 125A 3000W 0 ~ 200A. 3000W 150mVp-p 3000W

Note1: Typical values at nominal input voltage and full load. 17.5VDC. Open, 4.5V Short, 0V. 5mA. Efficiency vs. Input Voltage.

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

Packaging. nom. Output Voltage

NEVO+1200M. 6 x6 x W. 1.2kg DATA SHEET MAIN FEATURES

Watts HCP Series

Datasheet intrexis Boardnet Converter Platform IC304, 500 W-Output Single-Output 24 Vin 110 Vin

Datasheet. IC50X, 250 W Single-Output 600 Vin 750 Vin. Rev00

Efficiency [%] 115VAC 230VAC. Parameter Condition Value. Line Regulation low line to high line ±0.5% max. Load Regulation 10% to 100% load ±0.5% max.

Load (2) Single or Dual

Output Voltage nom. (adjustable)

Features. Regulated Converter. RAC02-SE/277 2 Watt Single Output RAC02- SE/277. AC/DC Converter

Output Voltage (Vfan) Convection-cooled (6,7) Forced-cooled (8) & Current

IEC/EN/UL60950 & CE certified, EN55032 Class B

LB115S 115W Single Output

Note1: Typical values at nominal input voltage and full load. 17.5VDC. Open, 4.5V Short, 0V. 5mA. Efficiency vs. Input Voltage.

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Features. Regulated Converter. REM6 6 Watt 2:1 & 4:1 DIP24 Single and Dual. Output. DC/DC Converter

Parameter Condition Min. Typ. Max. Internal Input Filter. refer to line derating graph on PA-4 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Power Supplies 3. SDN-C Compact DIN Rail Series

LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual. IM-LZSA500-3 January 2008 Revision H

1500W Single Output Power Supply AK V 100A 0~100A 1500W. 150mVp-p. Adjustment of output current is between 40 ~ 105% of rated output

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26

Features. Regulated Converters. RAC01-C RAC02-C 1-2 Watt Single Output RAC0_- C. AC/DC Converter

3000W Single Output Power Supply AK V 200A. 0 ~ 200A 3000W 150mVp-p

Load (2) Single or Dual

Output Voltage (Vfan) & Current

200 WATT TH SERIES DC/DC CONVERTERS

Output Voltage nom. (adjustable)

4.59A 2.36A 6.8A 13A 3.85W 2.85W ms 21ms. 31ms 100ms 48Vout 49ms 100ms. 240mVp-p 480mVp-p C 48Vout 480mVp-p

Features. Regulated Converters. RACM Watt Enclosed Case Style Single Output. RACM150- S/ _ Fan Option (1) Single. AC/DC Converter.

SYNRAD PS DC Power Supply (Meanwell RSP )

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms

Series AM30EW-Z 30 Watt DC-DC Converter

Voltage Adjustment. Load Regulation

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max.

Related Products SDP Series SFL Series SCP Series SCL Series SDU UPS

PSU s e r i es

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

Features. Regulated Converter RAC05- SK/C14. RAC 5 Watt Single Output RAC05-3.3SK/C14. AC/DC Converter

Features. Regulated Converter. RAC02-SE/277/W 2 Watt Single Output. RAC02- SE/277/W Wired. AC/DC Converter

Asia-Pacific North America Europe, Middle East Bel Power Solutions, Inc. BCD.

AC/DC Power Supply Series APPLICATION NOTE

An RS485 bus is used for command, monitoring and diagnostic information that can be supplied to a system controller.

Electrical Specifications

Features. Regulated Converter RAC Watt Single Output. AC/DC Converter

AC/DC Power Supply Series APPLICATION NOTE

AC/DC Power Supply Series APPLICATION NOTE

24V 40A 0 ~ 40A 960W. 150mVp-p 20 ~ 26.4V 83% 85% 88% 88% 90%

Series AMSRL1-78JZ Up to 12 Watt DC-DC Switching Regulator

ECP225-A Series. 225 Watts. AC-DC Power Supplies. Models & Ratings

Switching Power Supply Type SPP1 60W Enclosed type

Doc. EA Model Number:

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

Transcription:

Table of Contents 1. Introduction P1 2. Features P1 3. Block diagram P2 4. Options description P3 5. Input P3 6. Output P4 7. Auxiliary functions P5 8. Electromagnetic P6 9. Mechanical P8 10. Connector pin allocation P11 11. Safety and installation P12 12. Options and configufation P13 1. Introduction The DBA series, very compact and low profi le AC/DC power supply up to in chassis format, incorporates input filtering, input and output protections, very robust mechanical mounting and connection, conformal coating and MIL-STD options required in most of the severe environment for industrial, defense applications. The psu provides high reliability, high efficiency, input-to-output isolation, soft start and active very low inrush circuit, overtemperature protection, input over/ undervoltage lockout. The psu is configurable with 1 to 6 outputs in many output voltages from 2V to 54VDC, other outputs are even possible as semi-standard versions. They are continuously short-circuit proof. The 100 C baseplate allows operation in high temperature environment. 2. Features 85-264VAC or 120-350VDC input voltage ranges 1-6 isolated outputs up to 255 x 127 x 40mm very low profile Power Factor Correction EN61000-3-2 Active very low inrush limitation Surge and transient protection Many output configurations available Conduction cooled 100 C baseplate. No derating Safety IEC/EN 60950-1, RoHS lead-free-solder compliant 1

3. Block Diagram POSITION A 85-264VAC EMI FILTERING ACTIVE INRUSH CURRENT LIMITING + PFC 380VDC 3 x 150W μ Module OR Aout1 Aout2 Aout3 2 x 300W m Module OR Aout1 Aout2 1 x 600W M Module Aout1 3 x 150W μ Module OR Bout1 Bout2 Bout3 2 x 300W m Module OR Bout1 Bout2 1 x 600W M Module Bout1 POSITION B 4. Options Description MIL-STD ruggedized (-M) Meet MIL-STD 461E CE102, MIL-STD 1399-300A, MIL-STD810E shock & vibrations. No laboratory certification. -40 C operation (-T) The thermal grade of the DC/DC converters used and other components are changed to comply with low ambient temperature. Conformal coating (-V) During manufacturing process, when V option is specified, components and pcb are covered with an acrylic coating to address high level of ambiant humidity application. Heatsink (-H, -H1) -H: a 15 mm heatsink is mounted on the baseplate with longitudinal fins. -H1: a 15 mm heatsink is mounted on the baseplate with transversal fins. 2

5. Input Operating input voltage 85-264VAC. 120-350VDC. Frequency 44Hz min, 50Hz typ, 440Hz max. Power factor 0.96 typ, 230VAC, 50Hz, Pnom. Input current 16A at Vin min. No-load input power 15W at Vin typ. Peak inrush current 4A Vin max. Start-up time 3s typ. Input fuse A fuse mounted inside the psu protects against damages in case of a failure. The fuse is not user-accessible without opening the unit. In DC mode, reverse polarity at the input is protected and will not cause the fuse to blow. Fuse type Littlefuse, 15A, 0218015.MXP. Transient protection A VDR (Voltage Dependent Resistor) and a common mode input filter form an effective protection against input transients in severe environments. Estblishment time curve at 23VAC - DBA-5300-48150-550-3V375 Efficiency curve - DBA-5300-48150-550-3V375 Power factor curve - DBA-5300-48150-550-3V375 Power Factor 100,00% 90,00% 80,00% Vin=85Vac 70,00% Vin=115Vac 60,00% Vin=230Vac 50,00% Vin=264Vac 40,00% 30,00% 20,00% 10,00% 0,00% 20% 40% 60% 80% 100% Output Power Establishment time curve at 115VAC - DBA-5300-48150-550-3V375 3

Parallel operation Parrallel operation is possible in the same unit or between different units for m-boards, M-boards and 2M-boards with active current sharing through the PR signal. The outputs put in parallel MUST be exactly the same, all OUT+ connected together and all OUT- connected together when PR are linked (risk of damage otherwise). Thermal considerations When a converter is mounted in conduction cooled, the temperature measured on the baseplate should not exeed 100 C. When heatsink option is used in convection cooling and is operating at its nominal output power at the max. ambiant temperature, the temperature measured on the heatsink should not exceed 100 C. Redundant operation When systems require a very high level of reliability and should work normally in the event of a failure, N+1 redundancy is implemented where N is the number of converter to support power requirement. If one converter fails, the remaining ones still delivers the power to the loads. Redundant operation requires external oring diodes. Thermal protection A temperature protection (OTP) is integrated in each output module, disabling output when baseplate temperature exceeds 105 C (±5 C). The converter automatically restarts, when the temperature drops below 70 C. Nevertheless, exceeding the max operating temperature may cause failures of the converter. Hold-up time The psu provides internal hold-up time. Output current limitation All outputs are continously protected against short-circuit by a constant current limitation (no foldback) with automatic recovery. See page 3 for the value. Overvoltage protection An OVP is incorporated on each output. All outputs are cut if an OVP is detected. This protection is latch style (Recovery after AC reset or inhibit) 6. Output Electrical Output Data 3V3 5V 12V 15V 24V 28V 48V Characteristics Conditions min typ max min typ max min typ max min typ max min typ max min typ max min typ max Unit Output voltage 3V3 5 12 15 24 28 48 V Trim range Factory set 3 3.6 4.5 5.5 10.8 13.2 13.5 16.5 21.6 26.2 25.2 30.8 43.2 51.8 V Overvoltage protection 4.5 6.5 14.9 18.5 29.1 34 58 V Output noise 20Mhz 75 75 1200 100 100 100 150 mvpp Efficiency 75 83 85 84 83 84 % Load regulation Vin nom 1 1 0.5 0.5 0.4 0.4 0.4 % 2M board Each board include 2 identical M modules in parallel for high power configuration Output current 0 160 0 160 0 100 0 80 0 50 0 43 0 25 A Max power 528 800 1200 1200 1200 1200 1200 W Output power limit 184 208 184 208 115 135 92 112 58 78 48 58 28 34 A M board Each board includes 1 M module below Output current 0 80 0 80 0 50 0 40 0 25 0 21.5 0 12.5 A Max power 264 400 600 600 600 600 600 W Output current limit 92 104 92 108 57.5 67.5 46 56 29 39 24 29 14 17 A m board Each board includes up to 2 m modules below Output current 0 45 0 40 0 25 0 20 0 12.5 0 10.7 0 6.25 A Max power 150 200 300 300 300 300 300 W Output current limit 54 64 46 52 29 35 23 26 14.5 17 12.5 14.5 7.2 8.2 A μ board Each board includes up to 3 μ modules below Output current 0 22.7 0 20 0 12.5 0 10 0 6.25 0 5.3 0 3.1 A Max power 75 100 150 150 150 150 150 W Output current limit 25 31 23 26 14.5 17 11 14 7.2 8.2 6.2 7 3.6 4.4 A See options and configurations section for all the power possibilities. 4

7. Auxiliary Functions Remot on/off An isolated INHIB signal disables corresponding output voltage when connected to RTN. - outputs inhibited : INH level LOW. Inrush current at 115VAC - DBA-5300-48150-550-3V375 Overvoltage adjustment Output can be ajusted 90-110%Vnom. with the potentiometer at the output side or by an external voltage 0,6 to 1,25V max. referred to RTN. Remote sense This feature enables compensation of voltage drop across the connector contacts and the load lines. Remote Sense, max 0,5V per line compensation (If local sense, connect locally S+ to OUT+ and S- to OUTof the corresponding output). Senses are not included on m-board. Output type Total drop Positive line drop V1, V2 <0.5V <0.25V Power good & LED Collector isolated optocoupled signal referred to RTN, closed when all outputs voltages are OK. Led is also available for each output. Inrush current at 230VAC - DBA-5300-48150-550-3V375 Auxiliary bias voltage Auxiliary supply limited to 1mA. Referred to RTN. Paralleling signal Parallel only identical outputs (voltage and power). Outputs in parallel will current share when their corresponding PR are connected together. When outputs are coming from different boards, RTN have to be connected together. Input power break - DBA-5300-48150-550-3V375 Derating % 100 90 80 70 60 20ms at 230Vac output 568W Power 50 40 30 20 10 0 10 20 30 40 50 60 70 80 90 100 105 C Temperature 5

Waveforms Output noise - DBA-5300-48150-550-3V375 Waveforms Output noise - DBA-48600-48600-M 8. Electromagnetic Immunity Standard Level Value Waveform Source imped. Test procedure Mode Criteria Surges Built to meet EN61000-4-5 DM 3 1kV 1,2/50ms 12 ohms OP B CM 2lV 1,2/50ms 12 ohms OP A Electrostatic discharge Built to meet EN61000-4-2 4 8000V 1/50ms 330 ohms 10 pos, 10 neg OP B Fast transients/burst Built to meet EN61000-4-4 4 4000V 5/50ms 50 ohms OP B Emissions According to EN55022A/B for DBA-48600-48600 at 115VAC IN/800W According to MIL-STD461E CE102 DBA-48600-48600-M at 230VAC IN/800W 6

According to EN55022A/B for DBA-48600-48600 at 230VAC IN/ Immunity to Environmental Conditions Test Method Standard Test Conditions Status Damp heat MIL STD 810 Proc. 507-2 Humidity 93%, 40 C, 56 days Option (-V), built to meet Shock MIL STD 810 Proc. 516.3 20g/18ms half size, 5g/30ms Option (-M), built to meet Vibrations MIL STD 810 Proc. 514-5 4-80Hz (2,8m/s 2 ) / 2 Hz, non operating Option (-M), built to meet 7

9. Mechanical Size: 255 x 127 x 40 mm. Aluminum Natural. Weight: 1500g without heatsink. 8

H option H1 option 9

IP option 10

10. Connector Pin Allocation Description Pin Connector Input screw type connector GMKDS 3/3-7.62 1 J1-1 Earth 2 J1-2 Neutral AC/N 3 J1-3 Line AC/L Output 2M-board power connectors OUT+ J1 Wurth Pres Fit M4 Ref : 7461095 OUT- J2 Wurth Pres Fit M4 Ref : 7461095 Output M-board power connectors OUT+ J1 Wurth Pres Fit M4 Ref : 7461095 OUT- J2 Wurth Pres Fit M4 Ref : 7461095 Output m-board power connectors OUT1+ J1 Wurth Pres Fit M3 Ref : 7461093 OUT1- J2 Wurth Pres Fit M3 Ref : 7461093 OUT2+ J3 Wurth Pres Fit M3 Ref : 7461093 OUT2- J4 Wurth Pres Fit M3 Ref : 7461093 Output μ-board power connector 6 Pins Male OUT1+ J1-1 WURTH TBL3117691311700006 OUT1- J1-2 OUT2+ J1-3 OUT2- J1-4 OUT3+ J1-5 OUT3- J1-6 Signals Wurth 690368191472 Female Male 2*7 pins μ-board m-board M-board 2M-board J5-1 : ACFAIL J5-1 : ACFAIL J5-1 : ACFAIL J5-1 : ACFAIL J5-2 : PGOOD J5-2 : PGOOD J5-2 : PGOOD J5-2 : PGOOD J5-3 : RTN J5-3 : RTN J5-3 : RTN J5-3 : RTN J5-4 : INHIB J5-4 : INHIB J5-4 : NC J5-4 : NC J5-5 : +5VAUX J5-5 : +5VAUX J5-5 : +5VAUX J5-5 : +5VAUX J5-6 : NC J5-6 : S1+ J5-6 : NC J5-6 : NC J5-7 : NC J5-7 : S1- J5-7 : NC J5-7 : NC J5-8 : ADJ1 J5-8 : ADJ1 J5-8 : NC J5-8 : NC J5-9 : NC J5-9 : PR1 J5-9 : PR1 J5-9 : PR1 J5-10 : NC J5-10 : NC J5-10 : NC J5-10 : NC J5-11 : ADJ2 J5-11 : PR2 J5-11 : INHIB J5-11 : INHIB J5-12 : NC J5-12 : S2+ J5-12 : S1+ J5-12 : S1+ J5-13 : NC J5-13 : S2- J5-13 : S1- J5-13 : S1- J5-14 : ADJ3 J5-14 : ADJ2 J5-14 : ADJ1 J5-14 : ADJ1 DBA 2M board DBA M board DBA m board J5 14 12 10 8 6 4 2 13 11 9 7 5 3 1 DBA µ-board 11

11. Safety and Installation These converters are components, intended exclusively for integration into other equipment by an industrial assembly process or by a professionally competent person. Installation must strictly follow the safety regulations in respect of the enclosure, mounting, creepage and clearance distances, markings of the end-use application. Connection to the system shall be made via the male connector Wurth. The AC/L is internally fused. This fuse is designed to protect the converter against overcurrent caused by a failure, but may not be able to satisfy all requirements. External fuses in the wiring circuit to one or both input pins may be necessary to ensure compliance with local requirements. Do not open the PSU, or the warranty will be invalidated. Make sure that there is suffi cient thermal baseplate dissipation (max. temperature: 100 C). This should be verifi ed by measuring the case of temperature at the specifi ed measuring point, when the converter is operated in the end-use application. Standards and Approvals The converters are built to meet the safety standards IEC 60950-1, EN 60950-1. Built to meet mentioned in the diff erent paragraphs of the datasheet means that Powerbox has designed the product to meet the standard but not certified it in a laboratory. Qualifi ed means that the test has been made in a certified laboratory. Cleaning Agents and Process The converters are not hermetically sealed. In order to avoid possible damage, any penetration of liquids shall be avoided. Isolation The electric strength test is performed in the factory in accordance with IEC/EN 60950. Electric Strength Characteristic Input to Earth Input to Output Output to Earth Output to Output Unit Electric strength Design strength 1500 3000 500 Vrms Factory test for production 2000 2000 500 Vdc Insulation resistance > 100 >100 Mohms Temperature Standard T option Conditions Min Typ Max Min Typ Max Unit Ambiant Operating (see derating) -20 +71-40 +71 C Heatsink -20 +100-40 +100 C Storage Not operating -40 +125-40 +125 C In operation, there is no power derating as long as the baseplate temperature is in the below indacated range. Reliability MIL-HFBK-217F, notice 2 Model Heatsink Temp GB GF MTBF ( Hours) DBA 3 outputs 40 C 285000 16500 70 C 139000 82300 100 C 86600 51000 MTBF calculation for a specific part number has to be ordered. 12

12. Options and Configuration Input Stage DBA Position A Vin 1 2 3 For m-board 1 2 For m-board 1 For M-board 1 For 2M-board Position B 1 2 3 For m-board 1 2 For m-board 1 For M-board 1 For 2M-board DBA - AOUT1 AOUT2 AOUT3 - BOUT1 BOUT2 BOUT3 *) μ μ μ μ μ μ μ μ μ m m μ μ μ M m m m m m m M M M 2M *)Options H : Heatsink longitunal fins H1 : Heatsink transversal fins IP : IP65 enclosure M : Ruggedized T : -40 C V : Conformal coating 13

μ-μ-μ : μ-board Aout1,Aout2,Aout3 or Bout1,Bout2,Bout3: Up to 3 outputs with μ-modules from 2V to 48VDC 150W (see table page 2). Note: High current, low voltage outputs have to be placed on Aout3 or Bout3 in priority. μ μ μ v w v w v w N N N N N N 2 50 2 50 2 50 3V3 50, 75 3V3 50, 75 3V3 50, 75 5 50, 100 5 50, 100 5 50, 100 8 100 8 100 8 100 12 75, 150 12 75, 150 12 75, 150 15 75, 150 15 75, 150 15 75, 150 24 75, 150 24 75, 150 24 75, 150 28 75, 150 128 75, 150 28 75, 150 36 75, 150 36 75, 150 36 75, 150 48 75, 150 48 75, 150 48 75, 150 M : M-board Aout1 &/or Bout1: 1 output with M-module from 2V to 54VDC 600W (see table page 2). M v w N N 2 160 3V3 200, 264 5 300, 400 8 300, 400 12 400, 600 15 400, 600 24 400, 600 28 400, 600 32 600 36 400, 500, 600 48 400, 600 54 600 m-m : m-board Aout1,Aout2 or Bout1,Bout2: Up to 2 outputs with m-modules from 2V to 48VDC 300W (see table page 2). Note: High current, low voltage outputs have to be placed on Aout1 or Bout1 in priority. m m v w v w N N N N 2 100 2 100 3V3 100, 150 3V3 100-150 5 150, 200 5 150, 200 8 200 8 200 12 200, 300 12 200, 300 15 200, 300 15 200, 300 24 200, 300 24 200, 300 28 200, 300 28 200, 300 36 200, 300 36 200, 300 48 200, 300 48 200, 300 2M : 2M-board Aout1 & Bout1: 1 output with M-module from 2V to 54VDC (see table page 2). 2M v w N N 2 320 3V3 400, 528 5 600, 800 8 600, 800 12 800, 1200 15 800, 1200 24 800, 1200 28 800, 1200 32 1200 36 800, 1000, 1200 48 800, 1200 54 1200 Empty slots are filled with NN Example : DBA-48150-48150-48150-48150-48150-48150-M (2 μ-boards with 6 outputs of 48V 150W with MIL-STD option). DBA-3V375-5100-12150-24300-28300 (1 μ-board with 3 different outputs and 1 m-board with 2 different outputs). 2017.05.17 14