PERFORMANCE OF A NEW MEMS MEASUREMENT MICROPHONE AND ITS POTENTIAL APPLICATION

Similar documents
Multi-field Microphone when the Sound Field is unknown

THE ATTENUATION OF NOISE ENTERING BUILDINGS USING QUARTER- WAVE RESONATORS: RESULTS FROM A FULL SCALE PROTOTYPE. C.D.Field and F.R.

Technical Data Measurement Microphones

FREQUENCY RESPONSE AND LATENCY OF MEMS MICROPHONES: THEORY AND PRACTICE

RD75, RD50, RD40, RD28.1 Planar magnetic transducers with true line source characteristics

Development of multichannel single-unit microphone using shotgun microphone array

Balanced Armature Check (BAC)

Proceedings A Comb-Based Capacitive MEMS Microphone with High Signal-to-Noise Ratio: Modeling and Noise-Level Analysis

TONAL ACTIVE CONTROL IN PRODUCTION ON A LARGE TURBO-PROP AIRCRAFT

Production Noise Immunity

EQUIVALENT THROAT TECHNOLOGY

Acoustic Calibration Service in Automobile Field at NIM, China

Microphone Cartridge Model: MP201

MICROMACHINED INTERFEROMETER FOR MEMS METROLOGY

VM2000. Low-Noise Bottom Port Piezoelectric MEMS Microphone Data Sheet Vesper Technologies Inc. Differential Analog Output

EFFECTS OF PHYSICAL CONFIGURATIONS ON ANC HEADPHONE PERFORMANCE

PRODUCT DATA. Sound Intensity Probe Kit Type 3599 including Sound Intensity Microphone Pair Type 4197 and Dual Preamplifier Type 2683

High-speed wavefront control using MEMS micromirrors T. G. Bifano and J. B. Stewart, Boston University [ ] Introduction

Practical Limitations of Wideband Terminals

DESIGN OF A PROTOTYPE OF A SMART NOISE MONITOR- ING SYSTEM

Digitally controlled Active Noise Reduction with integrated Speech Communication

ANALYTICAL NOISE MODELLING OF A CENTRIFUGAL FAN VALIDATED BY EXPERIMENTAL DATA

Fundamentals of Environmental Noise Monitoring CENAC

North D25-06S. High performance silk dome tweeter for cabinets six to ten inches in width

DESIGN OF ROOMS FOR MULTICHANNEL AUDIO MONITORING

Exclusive Technology Feature. Integrated Driver Shrinks Class D Audio Amplifiers. Audio Driver Features. ISSUE: November 2009

High Resolution Ear Simulator

An automatic method to detect defaults in the measurement chain of a sound level meter, used for unattended noise measurements

Texas Components - Data Sheet. The TX53G1 is an extremely rugged, low distortion, wide dynamic range sensor. suspending Fluid.

Distortion in acoustic emission and acceleration signals caused by frequency converters

New transducer technology A.R.T. = Accelerated Ribbon Technology - evolution of the air motion transformer principle

PRODUCT DATA. Sound Intensity Probe Kit for 2260 Type 3595 Sound Intensity Microphone Pair Type 4197 Dual Preamplifier Type 2683

Pilot experiments for monitoring ambient noise in Northern Crete

INFLUENCE OF THE PERFOMANCE PARAMETERS IN TRANSMISSION LINE LOUDSPEAKER SYSTEM

PRODUCT DATA. Sound Intensity Probe Kit Type 3599 Sound Intensity Microphone Pair Type 4197 Dual Preamplifier Type 2683

Signals & Systems for Speech & Hearing. Week 6. Practical spectral analysis. Bandpass filters & filterbanks. Try this out on an old friend

CHAPTER 3 THE DESIGN OF TRANSMISSION LOSS SUITE AND EXPERIMENTAL DETAILS

19 th INTERNATIONAL CONGRESS ON ACOUSTICS MADRID, 2-7 SEPTEMBER 2007

A White Paper on Danley Sound Labs Tapped Horn and Synergy Horn Technologies

A 3 TO 30 MHZ HIGH-RESOLUTION SYNTHESIZER CONSISTING OF A DDS, DIVIDE-AND-MIX MODULES, AND A M/N SYNTHESIZER. Richard K. Karlquist

In situ assessment of the normal incidence sound absorption coefficient of asphalt mixtures with a new impedance tube

High Voltage Charge Pumps Deliver Low EMI

Offaly County Council

Application Note. Airbag Noise Measurements

8th AIAA/CEAS Aeroacoustics Conference June 16 18, 2002/Breckenridge, CO

High intensity and low frequency tube sound transmission loss measurements for automotive intake components

Loudspeakers. Juan P Bello

Multi-channel Active Control of Axial Cooling Fan Noise

Rub & Buzz Detection with Golden Unit AN 23

Josephson Engineering, Inc. 329A Ingalls Street Santa Cruz, California Josephson Engineering Rev B

19 th INTERNATIONAL CONGRESS ON ACOUSTICS MADRID, 2-7 SEPTEMBER 2007 VIRTUAL AUDIO REPRODUCED IN A HEADREST

Attenuation of low frequency underwater noise using arrays of air-filled resonators

Small, Low Power, High Performance Magnetometers

Ears Project Newsletter No 3. Welcome. C o n t e n t s. Welcome Preface of the coordinator. News & facts Latest news

Consideration of standardisation requirements for vibration dosemeters

19 th INTERNATIONAL CONGRESS ON ACOUSTICS MADRID, 2-7 SEPTEMBER 2007 CHALLENGES OF HIGH SNR (SIGNAL-TO-NOISE) SILICON MICROMACHINED MICROPHONES

Audio Engineering Society. Convention Paper. Presented at the 122nd Convention 2007 May 5 8 Vienna, Austria

IST IP NOBEL "Next generation Optical network for Broadband European Leadership"

A Guide to Reading Transducer Specification Sheets

GRAS 40BD-FV 1/4" Prepolarized Pressure Microphone, Front Vented

EXTENDED OPERATIONAL RANGE OF A FEEDBACK-CONTROLLED OPTICAL MICROPHONE FOR AEROACOUSTICS RESEARCH. Sara Feeney

MEMS Real-Time Clocks: small footprint timekeeping. Paolo Frigerio November 15 th, 2018

Instrumentation, Controls, and Automation - Program 68

BROADBAND CAPACITIVE MICROMACHINED ULTRASONIC TRANSDUCERS RANGING

SmartSenseCom Introduces Next Generation Seismic Sensor Systems

DETECTOR. Figure 1. Diode Detector

Acoustic characteristics of annular jets

Resonant MEMS Acoustic Switch Package with Integral Tuning Helmholtz Cavity

Development of a High Sensitivity DFB Fibre Laser Hydrophone Work in Progress at National University of Singapore

The design and calibration of low cost urban acoustic sensing devices. SONYC Sounds Of New York City

2018 Data Sheet Vesper Technologies Inc. VM1000. Low-Noise Bottom Port

PRODUCT DATA. Applications. Uses

DATA BULLETIN MX315A. Programmed Clocks. TX Tone Square Wave

Selection of Microphones for Diffusion Measurement Method

The Design of E-band MMIC Amplifiers

AN-1098 APPLICATION NOTE

NVH analysis of a 3 phase 12/8 SR motor drive for HEV applications

ENHANCED PRECISION IN SOURCE LOCALIZATION BY USING 3D-INTENSITY ARRAY MODULE

Maximizing LPM Accuracy AN 25

Rocking Drones with Intentional Sound Noise on Gyroscopic Sensors

3D Distortion Measurement (DIS)

CHAPTER 4 FUZZY BASED DYNAMIC PWM CONTROL

DESIGN OF VOICE ALARM SYSTEMS FOR TRAFFIC TUNNELS: OPTIMISATION OF SPEECH INTELLIGIBILITY

PRODUCT DATA. Sound Intensity Calibrator Type Uses and Features

Inter-Ing INTERDISCIPLINARITY IN ENGINEERING SCIENTIFIC INTERNATIONAL CONFERENCE, TG. MUREŞ ROMÂNIA, November 2007.

Acoustics, signals & systems for audiology. Week 4. Signals through Systems

Series KM A. Product Information. Miniature Microphone System

Tower Mains. A new breed of Main Monitors

ECMA-108. Measurement of Highfrequency. emitted by Information Technology and Telecommunications Equipment. 5 th Edition / December 2010

CONSIDERATIONS FOR ACCELEROMETER MOUNTING ON MOTORS

Silent Transformers to Help Consolidated Edison Meet New York City s Ultrastrict Noise Ordinances

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Holographic Measurement of the Acoustical 3D Output by Near Field Scanning by Dave Logan, Wolfgang Klippel, Christian Bellmann, Daniel Knobloch

DATA ANALYSIS FOR VALVE LEAK DETECTION OF NUCLEAR POWER PLANT SAFETY CRITICAL COMPONENTS

Measuring Instrument Combinations

ACOUSTIC DATA TRANSMISSION IN AIR USING TRANSDUCER ARRAY

DISCRETE DIFFERENTIAL AMPLIFIER

The influences of changes in international standards on performance qualification and design of anechoic and hemi-anechoic chambers

SIGNAL PROCESSING ALGORITHMS FOR HIGH-PRECISION NAVIGATION AND GUIDANCE FOR UNDERWATER AUTONOMOUS SENSING SYSTEMS

ACTIVE LOW-FREQUENCY MODAL NOISE CANCELLA- TION FOR ROOM ACOUSTICS: AN EXPERIMENTAL STUDY

Transcription:

PERFORMANCE OF A NEW MEMS MEASUREMENT MICROPHONE AND ITS POTENTIAL APPLICATION R Barham M Goldsmith National Physical Laboratory, Teddington, Middlesex, UK Teddington, Middlesex, UK 1 INTRODUCTION In deciding how to determine the sound level of a particular environment or source, the selection of microphone is frequently a limiting factor. In the area of environmental noise monitoring, for example, it would be ideal if arrays of low-cost transducers were continuously available for periods or many months. It would then be possible to obtain multi-point measurements of the noise fields of, for example, roads, railways, factories or streets which would include diurnal and seasonal variations at all likely listener positions 1. In the measurement of the sound fields due to particular machines and installations especially large ones like air-conditioning systems or pump installations - an array of low-perturbation transducers spread over an enveloping surface would also be ideal 2. A third example is that of condition monitoring, where small, low-cost, robust transducers could be permanently installed in vehicles or domestic products, and be used to check on changes in acoustic signature which would indicate degradation of performance. In reality, the microphones and associated equipment currently available are highly unsuitable to such tasks, being expensive, large, somewhat perturbing and not particularly robust. Furthermore, their relative instability compared to other measuring devices means that an in-situ calibration is required (in the form of, for example, a sound calibrator). The difference between desirable measurement instruments and real ones is so significant that completely different approaches are taken to determining noise levels. Thus, predictive noise modelling is used for noise mapping, often not constrained by measurement at all (but on, for example, traffic flow predictions for road noise) temporal variations are modelled or ignored. Similarly, sound power measurement of large machines or installations employs a range of compromises and simplifying assumptions, while condition monitoring by acoustic measurement is rarely used. The enormous increase in recent years of the number of cell phones led to an immediate and unprecedented demand for low-cost, robust microphones. This was met by the rapid development of microphones constructed on silicon chips, so called MEMS (MicroElectroMechanical Systems) microphones 3,4. The cost of these transducers is a tiny fraction of that of conventional condenser microphones. If it were possible to use MEMS-based microphones in place of current measurement microphones, the reduction in cost alone would allow enormous improvements in noise measurements, and their small size and robustness would also be very significant advantages. The problem with this is of course that cell phone microphones are not intended to be used as measurement devices, so there is no guarantee of their stability (over time or over environmental conditions, in particular temperature). Also, they are required to function only over a narrow frequency range. The question therefore arises: is it possible to design and build a MEMS-based microphone which could produce more useful results than current measurement systems and/or predictive approaches? Vol. 30. Pt.2 2008

To answer these questions, a number of collaborative projects led by the Acoustics Group of the UK National Physical Laboratory have been undertaken, funded both by the DTI/DIUS NMS and Technology Programmes. The remainder of this paper will describe elements of this work. 2 TEAM There have been two main phases to this work; the first running from October 2004 to September 2007, and involving NPL with QinetiQ and Strathclyde University, the second running from October 2007 to September 2010 with a team comprising NPL, QinetiQ, Castle and Hoare Lea Acoustics. The first project designed and built experimental prototype transducers exploiting technology available at QinetiQ 5 and tested them in laboratories, while the current one is producing enhanced transducers, installing them in prototype measuring devices and testing them, both in laboratories and as arrays in real environments. 3 TRANSDUCER DESIGN The key design targets associated with the MEMS microphone (see Figures 1 and 2) are: Diaphragm resonant frequency, which should be significantly higher than the required upper frequency limit (20 khz in this case). For this project, >30 khz was specified. Mechanical Q-factor of the membrane. This was chosen to be 0.5 in this project. Microphone sensitivity (1 mv/pa here). The minimum detectable A-weighted sound pressure level. This relatively challenging parameter is determined by the noise from the microphone, the bias resistor and the associated electronics as well as the microphone sensitivity. The original target set for this was 45 dba, reduced to 30 dba for the next phase of the project. The maximum sound pressure level that the microphone can measure within a set limit of total harmonic distortion. Target for this application was 110 db. The difference between this and the minimum detectable A-weighted sound pressure level defines the acoustical dynamic range of the microphone. (In practice the electrical dynamic range may be less than this and may define the actual dynamic range of the microphone) Figure 1: Schematic view of microphone design (QinetiQ copyright image)

Figure 2: General view of prototype transducer (QinetiQ copyright image) 4 LABORATORY TESTS Aside from the design and fabrication of the MEMS microphones, a significant element of the project was to develop a suite of calibration and testing facilities to enable the electroacoustic performance of both bespoke and commercially available MEMS microphones to be fully evaluated. This was considered to be a key project development, as no similar facilities or corresponding data have been reported in the literature on MEMS microphones. Facilities and techniques have therefore been developed at NPL to evaluate the following parameters; Pressure sensitivity in the range 31.5 Hz to 20 khz, Free field sensitivity at normal incidence and 90 degrees incidence in the range 100 Hz 25 khz, Signal-to-noise ratio (and hence noise floor) in the range 20 Hz to 20 khz Total harmonic distortion, Dynamic range These facilities were employed to test the prototype MEMS microphones produced by QinetiQ. Results for representative devices are reported below. Some comparison measurements of a Commercial Off-The Shelf (COTS) MEMS microphone, designed for mobile phone use, were also made. Comparative reference data for Brüel and Kjær eighth-inch (4138), quarter-inch (4135) and half-inch (4133) microphones are also shown. 4.1.1 Free field frequency response These tests were carried out in the NPL full anechoic chamber. A comparison method adopting a substitution approach was used. A reference microphone (Brüel and Kjær type 4180) was first used to establish the sound pressure at the point of calibration. The MEMS microphone under test was then substituted into this sound field and its response to the known sound pressure determined. Comparison calibrations were conducted in the frequency range from 100 Hz to 25 khz.

Figure 3 shows the response of a QinetiQ microphone and is compared with an equivalent response for a commercially available device. 210.0 190.0 Sensitivity (mv/pa) 170.0 150.0 130.0 110.0 90.0 70.0 1500b 1500a 1000b 1000a Average 50.0 100 1000 10000 100000 Frequency (Hz) Figure 3: Free-field response of QinetiQ microphone (line labels include measurement distance in mm and test sequence identifier) The ripple in the frequency responses and the spikes observable around 6 khz and 9 khz are almost certainly due to imperfections in the free-field performance of the room, mainly arising from the use of a pure tone test signal. A comparison of free-field responses of the COTS microphone with the QinetiQ one shows that, as hoped, the high-frequency increase in sensitivity seen in the response of the COTS device is much reduced in the QinetiQ microphone (Figure 4).

16 14 12 Normalised sensitivity (db) 10 8 6 4 2 0 100 1000 10000 100000-2 QinetiQ COTS -4 Frequency (Hz) Figure 4: Free-field responses of bespoke and commercial MEMS microphones compared The general rise in sensitivity with frequency of the QinetiQ device is due, at least in part, to interaction of the acoustical field with the microphone assembly. This is the same effect that gives rise to a free-field correction for conventional measurement microphones and is investigated further below. 4.1.2 The influence of mounting geometry on microphone sensitivity A number of experiments were conducted on the effects of different mountings on the microphone sensitivity variation. Space limitations preclude the inclusion of full details here, but it is clear that, despite the small size of the microphone itself, the packaging geometry has a significant impact on the frequency-dependence of the sensitivity, due to diffraction effects, and that, in designing MEMSbased acoustic sensors, the optimum geometry would be one in which the diaphragm is mounted on the end of a rod of the same circumference, thus reducing the frontal area to a minimum. Alternatively, in designing microphones in the future it would be necessary to consider an appropriately controlled damping mechanism that can be used to compensate for the enhancement effect of the geometry. This is the approach taken to produce conventional measurement microphones having a flat free-field response, despite the diffraction effects that results due to their size. However replicating the approach at the MEMS level may present significant technical challenges. 4.1.3 Noise floor MEMS microphones typically have significantly higher noise-floors than conventional devices, but can in principle be accurately "tuned" at the design phase to have relatively low noise floors albeit at the expense of reduced frequency bandwidth.

The noise floors of the MEMS microphones were determined by simply removing any sound from the environment as far as possible, and measuring the persisting output from the microphone, which was then assumed to be the self-noise of the device. The NPL hemi-anechoic chamber was known to have an acoustic background level below 0 db SPL, so this was used as the test environment for determining the noise floor. Before proceeding, the actual background noise was established using a very high sensitivity microphone system. See Table 1 for results. 4.1.4 Total harmonic distortion (THD) Distortion in MEMS microphones results when the deflection of the membrane becomes sufficiently large that it can no longer be considered small compared to the gap size between the membrane and backplate (such an assumption is required to linearise the analytical model of the membrane dynamics). Indeed this is true of all microphones, but in MEMS devices the gap size is itself already very small (c. 1 µm). The THD of the MEMS microphones was measured by placing the devices within a closed pressure driver, along with a calibrated WS3 microphone. The WS3 microphone was used to monitor the sound pressure level within the pressure driver, while a frequency analysis of the MEMS microphone output was carried out: the levels of the fundamental (1 khz) and the first six harmonics, were measured directly from the analyser and used to calculate THD. The process was repeated with 1 db increases in the sound pressure level until the THD reached around 5%, where the tests were terminated to avoid damaging the MEMS devices. However, a COTS device was tested to much higher levels, to investigate whether these devices actually fail at some point. It is noticeable that the distortion of the QinetiQ device, in the upper range of sound pressures to which it was exposed, is less than that of the COTS transducer. See Table 1 for numerical results. 26 24 22 20 18 16 14 Distortion (%) 12 10 8 6 4 2 0 COTS QinetiQ 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 Sound pressure (db) Figure 5: Distortion tests

4.1.5 Dynamic range The dynamic range is defined here as the difference between the A-weighted noise floor and the SPL required to produce a distortion of 5% at 1 khz. The data measured in the tests described above have been used to determine the dynamic ranges given below Device A-weighted noise floor SPL at 5% THD (db) Dynamic range (db) QinetiQ 51.2 116 65 COTS 42.4 113 71 B&K 4138 ⅛" 56 174 118 B&K 4135 ¼" 39 170 131 B&K 4133 ½" 26 161 135 Table 1: Dynamic ranges 5 NEXT STEPS The next phase of the project will aim to illustrate the potential impact of MEMS measurement microphones using a specific application to drive the technological developments required. The selected application involves the use of MEMS microphones in the development and testing of an innovative approach to the validation of strategic environmental noise maps. However such developments will be readily applicable to a wide range of other applications. The approach involves the deployment of DREAMSys, an array of approximately 100 wireless sensor devices containing MEMS-based microphones, including enhanced versions of the type reported above which are planned to have significantly lower noise floors. The remainder will be low-cost commercial devices of lower performance. The array will be tested for one year at a specially selected site, and the results used to validate a predictive noise map of that site. The information and knowledge gained from this field trial will lead to guidance on the adoption of a new approach to noise mapping and validation based on a mix of measurement and prediction. The array-based system will be available for use for future mapping projects. 6 ACKNOWLEDGEMENT The contribution to this work from the Microsystems team at QinetiQ Malvern Technology Centre, in developing the MEMS measurement microphones is gratefully acknowledged. The authors also gratefully acknowledge the financial support of the National Measurement System Programmes Unit of the UK Department for Innovation, Universities and Skills. 7 REFERENCES 1. B Vincent and J Lambert. Assessing the quality of urban sound environment: complementarity between noise monitoring system, noise mapping and perception survey, the stakes for the information to the public. Congress and Exposition on Noise Control Engineering, Rio de Janeiro, August 2005. 2. D Simmons and R Payne. R Problems in the industrial application of procedures for measurement of machinery noise emission. NPL Report DQL-AC 017. 2007

3. Peter V. Loeppert and Sung B. Lee. A commercialized MEMS microphone for high-volume consumer electronics. J. Acoust. Soc. Am. Volume 116, Issue 4. 2004 4. G W Elko, et al. Surface-Micromachined MEMS Microphone. AES Convention Paper Number No. 5889. 115th AES Convention. New York. October 2003. 5. K M Brunson. MEMS microphone technology. IEE Seminar and Exhibition on MEMS Sensor Technologies. London. April 2005.