ProLong Glass Antifade Mountant

Similar documents
Nikon Instruments Europe

AbC Total Antibody Compensation Bead Kit

EVOS M5000 Imaging System

Confocal Laser Scanning Microscopy

SHORT INSTRUCTIONS FOR OPERATING LSM1/2 (Zeiss LSM510) AT CIAN Version 1.4, September 2014

Supplementary Information. Stochastic Optical Reconstruction Microscopy Imaging of Microtubule Arrays in Intact Arabidopsis thaliana Seedling Roots

Operation Guide for the Leica SP2 Confocal Microscope Bio-Imaging Facility Hunter College October 2009

Why and How? Daniel Gitler Dept. of Physiology Ben-Gurion University of the Negev. Microscopy course, Michmoret Dec 2005

LSM 710 Confocal Microscope Standard Operation Protocol

Operating Instructions for Zeiss LSM 510

ANSWER KEY Lab 2 (IGB): Bright Field and Fluorescence Optical Microscopy and Sectioning

Introduction. INSTRUCTION MANUAL CAT XL, 6500-XLCORE, 6500-FL Evos-XL, Evos-XL/Core, Evos-FL

Nikon Ti-E Microscope Manual. Rightmire Hall Ohio State University. Director: Tony Brown Rightmire

Last updated: May 2014 Y.DeGraaf

ZEISS LSM510META confocal manual

LSM 510 META in Chang Gung University

1 Co Localization and Working flow with the lsm700

Zeiss LSM880 Operating Instructions. UTMB Optical Microscopy Core Jan. 16, 2018

Things to check before start-up.

TRAINING MANUAL. Multiphoton Microscopy LSM 510 META-NLO

Microscopy. The dichroic mirror is an important component of the fluorescent scope: it reflects blue light while transmitting green light.

Olympus Fluoview 1000S Spectral Confocal Microscope Introduction to the NRI-MCDB Microscopy Facility Spectral Confocal Microscope

Nikon E800 Operating Instructions.

Figure 1. Oil-immersion objectives available for use with the Lionheart FX.

INTRODUCTION TO MICROSCOPY. Urs Ziegler THE PROBLEM

Bi/BE 227 Winter Assignment #3. Adding the third dimension: 3D Confocal Imaging

Confocal Microscopy and Related Techniques

Imaging Introduction. September 24, 2010

Internal Medicine Imaging Core Emory University Department of Medicine

Quick Start Guide. Leica SP5 X

Light Microscopy. Upon completion of this lecture, the student should be able to:

3. are adherent cells (ie. cells in suspension are too far away from the coverslip)

Basics of confocal imaging (part I)

Travel to New Dimensions- LSM 880. The Resolution of a Microscope is limited. The Resolution of a Microscope is limited. Image. Image. Object.

Observing Microorganisms through a Microscope LIGHT MICROSCOPY: This type of microscope uses visible light to observe specimens. Compound Light Micros

Supplemental Figure 1: Histogram of 63x Objective Lens z axis Calculated Resolutions. Results from the MetroloJ z axis fits for 5 beads from each

Nikon E800 Operating Instructions.

Using the Nikon TE2000 Inverted Microscope

CFIM MICROSCOPY COURSE PROGRAMME PRINCIPLES OF MICROSCOPY CONFOCAL AND FLUORESCENCE MICROSCOPY

Leica Sp5 II Confocal User Guide

Zeiss LSM 510 Confocor III Training Notes. Center for Cell Analysis & Modeling

FLUORESCENCE MICROSCOPY. Matyas Molnar and Dirk Pacholsky

Bio 407. Applied microscopy. Introduction into light microscopy. José María Mateos. Center for Microscopy and Image Analysis

Practical work no. 3: Confocal Live Cell Microscopy

Nikon Eclipse Ti2-E Widefield/Spinning Disk Confocal Microscope Standard Operation Protocol

Confocal Application Letter No. 13. Sequential Scan for Leica TCS NT/SP systems

You won t be able to measure the incident power precisely. The readout of the power would be lower than the real incident power.

Super Resolution Microscope N-SIM E. Super Resolution Microscope

Multicolor 4D Fluorescence Microscopy using Ultrathin Bessel Light sheets

We attempted to separate the two dyes by acquiring images using a single excitation wavelength and just two emission wavelengths.

Boulevard du Temple Daguerrotype (Paris,1838) a busy street? Nyquist sampling for movement

Nikon E800 Microscope. Operating Instructions

Final Exam, 150 points PMB 185: Techniques in Light Microscopy

Nikon. King s College London. Imaging Centre. N-SIM guide NIKON IMAGING KING S COLLEGE LONDON

LSM 780 Confocal Microscope Standard Operation Protocol

Microscope anatomy, image formation and resolution

Microscopy Live Animal Imaging

Training Guide for Carl Zeiss LSM 510 META Confocal Microscope

Zeiss LSM 880 Protocol

Point Spread Function. Confocal Laser Scanning Microscopy. Confocal Aperture. Optical aberrations. Alternative Scanning Microscopy

Spectral Imaging with the Opterra Multipoint Scanning Confocal

IN Cell Analyzer 6500HS

Advanced Optical Microscopy lecture. 03. December 2012 Kai Wicker

Training Guide for Carl Zeiss LSM 5 LIVE Confocal Microscope

Invitation for a walk through microscopy. Sebastian Schuchmann Jörg Rösner

3D light microscopy techniques

Topics. - How to calibrate the LSM scanner. - How to clean the microscope. - How to adjust the pinhole alignment. - How to adjust the Collimator

Diskovery Spinning Disk Guide

Comparing FCS and FRAP as methodologies for calculating diffusion

Maria Smedh, Centre for Cellular Imaging. Maria Smedh, Centre for Cellular Imaging

Zeiss 880 Training Notes Zen 2.3

INTRODUCTION TO OPTICAL MICROSCOPY

ImageXpress Micro XLS Widefield High Content Screening System. Imaging with a vision.

BD FC Beads 7-Color Kit

TRAINING MANUAL. Olympus FV1000

b. Turn the power switch and key to on position for blue laser.

LSM 800 Confocal Microscope Standard Operation Protocol

LSM 510 Meta Training Notes

BX-61: Brightfield Instruction /Continue to scroll for Fluorescent Instuctions

IC 2 S High Performance Objectives

Zeiss LSM 780 Protocol

Zeiss Axio Imager.A1 manual

Nikon C1si Spectral Laser Scanning Confocal Microscope. User Guide

LSM 510 Training Notes

personal DELTAVISION (pdv)

Quick Guide for Zeiss 710 Laser Scanning Confocal MGH Cancer Center

a) How big will that physical image of the cells be your camera sensor?

Sensitive imaging of spectrally overlapping fluorochromes using the LSM 510 META

Multifluorescence The Crosstalk Problem and Its Solution

CCAM Microscope Objectives

Akinori Mitani and Geoff Weiner BGGN 266 Spring 2013 Non-linear optics final report. Introduction and Background

Microscopy Techniques that make it easy to see things this small.

Lecture 16. OMX - Structured Illumination Microscopy Ian Dobbie x Microscopy Course Lecture 16 1

Tissue Preparation ORGANISM IMAGE TISSUE PREPARATION. 1) Fixation: halts cell metabolism, preserves cell/tissue structure

BASICS OF CONFOCAL IMAGING (PART I)

MULTIPHOTON MICROSCOPY. Matyas Molnar Dirk Pacholsky

Quick Guide for Zeiss 710 Laser Scanning Confocal MGH Cancer Center

contents TABLE OF The SECOM platform Applications - sections Applications - whole cells Features Integrated workflow Automated overlay

CCAM s Selection of. Zeiss Microscope Objectives

Examination, TEN1, in courses SK2500/SK2501, Physics of Biomedical Microscopy,

Transcription:

USER GUIDE ProLong Glass Antifade Mountant Catalog No. P36980, P36981, P36982, P36983, P36984, P36985 Pub. No. MAN0017262 Rev. A.0 Product information ProLong Glass Antifade Mountant is a glycerol-based, hard-setting, and ready-to-use mountant that is applied directly to fluorescently labeled cells or tissue samples on microscope slides for mounting. ProLong Glass mountant has a refractive index (RI) of ~1.52 after curing (Figure 1, page 3), which matches closely to glass coverslips and oil-immersion microscope objectives. This allows for increased resolution and sensitivity by minimizing refraction of the light path, which maximizes the light gathering potential of the microscope (Figure 2, page 3). ProLong Glass mountant is designed to provide unparalleled antifade protection across the entire visible and near-infrared spectra (Figure 4, page 4; Table 4, page 8). ProLong Glass mountant can be used with almost any fluorescent dye or fluorescent protein (e.g., GFP, RFP, mcherry) and any cell/tissue type from a depth of 0 μm to 100 μm for bright, high resolution Z-stack, 3-D, and 2-D images (Figure 3, page 4). ProLong Glass mountant does not discolor or extensively shrink when cured, making it possible to take high quality fluorescent images weeks or even months after mounting the slides. Table 1. Contents and storage Material Catalog No. Amount Storage* P36980 5 2 ml ProLong Glass Antifade Mountant P36982 2 ml ProLong Glass Antifade Mountant with NucBlue (Hoechst 33342) P36984 P36981 P36983 P36985 10 ml 5 2 ml 2 ml 10 ml Store at 2 8 C upon receipt. Avoid freeze/thaw cycles. Protect from light. * Product can be stored at 20 C for longer term storage. When stored as directed, the product is stable for at least 6 months from the date receipt. Benefits of ProLong Glass Antifade Mountant Features high refractive index of ~1.52 after curing, which is the same as glass coverslips, and is compatible with immersion oil and oil-immersion microscope objectives. Ideal for use with confocal laser scanning microscopy (CLSM) and other high resolution microscopes, while using immersion oil and oil-immersion microscope objectives. Protects fluorescent dyes and fluorescent proteins from photobleaching across the entire visible and near-infrared spectra. For Research Use Only. Not for use in diagnostic procedures.

Materials required but not provided Unless otherwise indicated, all materials are available through thermofisher.com. MLS: Fisher Scientific (fisherscientific.com) or other major laboratory supplier. Table 2. Materials required, but not provided. Item Source Cells/Tissue Slides Coverslips Conjugated probes for FISH, as needed Primary or secondary antibodies, as needed* Ethanol Glycerol, fluorescent microscopy grade Various vendors. Use positive and negative controls as needed. MLS; Use high quality slides made from crown, borosilicate, or soda lime glass. MLS; Use coverslip recommended by the objective manufacturer. Most of the oil immersion objective manufacturers recommend #1.5 coverslip made out of high-quality glass, such as Thermo Scientific Gold Seal Cover Slips (Fisher Scientific, Cat. No. 12-519-21A). MLS MLS MLS MLS Distilled water Thermo Fisher Scientific, Cat. No. 15230147 Image-iT Fixation/Permeabilization Kit Thermo Fisher Scientific, Cat. No. R37602 * To search through the vast Thermo Fisher Scientific primary antibody collection, visit our Antibody seach tool at thermofisher.com/us/en/home/life-science/antibodies. To detect low abundant targets, SuperBoost Tyramide Signal Amplification is recommended. Learn more at thermofisher.com/superboost. Table 3. Selection guide for ProLong and SlowFade antifade mountants. Feature ProLong Glass ProLong Diamond ProLong Gold SlowFade Diamond SlowFade Gold Hard/Soft setting Hard-setting (curing) Soft-setting (non-curing) Refractive index Z-stacking, 3D reconstruction/ deconvolution ~1.52 after curing (same as crown glass) Yes ~1.47 after curing ~1.47 after curing ~1.42 ~1.42 Not recommended Recommended objective type Oil-immersion* Glycerol-, water-, or air-corrective objectives** Cell/tissue thickness 0 100 μm Best results from 0 10 μm. Imaging up to 30 μm is possible under optimized conditions. Organic dye photobleach protection +++ +++ ++ +++ ++ Fluorescent protein photobleach protection +++ +++ Not recommended +++ Not recommended Slide storage after mounting Long term (weeks to months) Short term (days to weeks) * Best results are obtained with oil-immersion objective. Other objective types are also compatible. ** Best results are obtained with glycerol-corrective objective. Other objective types are also compatible. Photobleaching resistance was quantified on a Zeiss LSM 710 confocal microscope. HeLa or U2OS cells were stained and mounted using standard immunocytocehmistry (ICC) protocols. Five regions within three fields of view were scanned 15 times with 1.58 μs dwell time per pixel. Excitation wavelength and intensity were optimized by fluorophore. On an epi-fluoresence microsocope using 100-watt Hg-arc lamp, this amount of light/photon exposure will be equal to 60 90 seconds. In the table, +++ designates when 90% of signal intensity was left, as compared to initial signal intensity. ++ designates 80 90% remaining signal intensity and + represents 60 80% remaining signal intensity. ProLong Glass Antifade Mountant 2

Figure 1. ProLong Glass Antifade Mountant cures to a final RI of ~1.52. The refractive indices of various ProLong Antifade Mounting Media were measured using a Thermo Scientific ABBE-3L refractometer by applying 300 µl of mountant and spreading to cover the measuring prism surface. Mountants were cured open to air at room temperature and read by closing the prism case at indicated time points. Plotted data shows the change in refractive index of each mountant as a function of time. The curing time for 1 2 drops (40 80 μl) of mountant on cultured cells or tissue sections of less than 10 μm under a coverslip is 12 24 hours. Tissue sections thicker than 10 μm take more time to cure and require 24 48 hours. Humidity level in the air and/or the temperature during curing or analysis can also effect the RI of the sample. Figure 2. Lateral and axial resolution as a point spread function of detected 170 nm microspheres. To detect the lateral and axial resolution at various focal depths, sub-resolution fluorescent yellow (Ex/Em 505 nm/515 nm) 170 nm microspheres were suspended on the surface of a glass coverslip. Same 170 nm microspheres were also mixed with 100 μl of either ProLong Glass (RI~1.52 after curing) or ProLong Diamond (RI~1.47 after curing) and suspended throughout the mountant. The mountant-microsphere mixture was spread over a 18 mm 18 mm area on a microscope slide and was left to cure without a coverslip on it. Next day, 10 µl of glycerol was placed on top of each sample and coverslips (Zeiss high tolerance #1.5 170 nm ± 5 nm) were mounted on the samples (a thin layer of undiluted gycerol helps the coverslip to adhere and mount on the cured sample). Coverslips were allowed to adhere for 1 hour before imaging. Z-stacks of individual microspheres were collected on a Zeiss LSM 710 confocal microscope using a Plan-Apochromat 63x/1.4 NA Oil objective, sampling at a rate of 42 nm in x, y and 100 nm in the z dimensions. Lateral (x, y) and axial (z) resolutions were calculated using the ImageJ MetroloJ plugin. Plotted data shows axial and lateral resolutions as a function of focal depth. ProLong Glass with a refractive index of ~1.52 maintains a higher axial resolution than mountants with a refractive index of ~1.47 across focal depts. Lateral resolution remains the same in both mountants at all focal depths tested as expected. The maximum theoretical axial resolution of the microscope is 500 nm, with 200 nm for lateral direction. ProLong Glass Antifade Mountant 3

Figure 3. Improved axial resolution in FFPE pig liver tissue. FFPE preserved pig liver tissue sections were prepared for fluorescence microscopy and stained overnight with the nuclear stain DAPI. These 100 μm thick sections were mounted using either (A) ProLong Diamond (RI ~1.47) or (B) ProLong Glass (RI ~1.52) mountants. A coverslip was applied to the tissue section mounted with ProLong Diamond and left to cure for 24 hours before imaging. For mounting with ProLong Glass, the tissue section was covered with the mountant spread evenly over an area of approximately 18 mm 18 mm. The sample was cured for 24 hours without a coverslip. After 24 hours, 10 µl of glycerol was added across the top of the sample using a pipette. A coverslip was applied to the sample and tapped to remove air bubbles. The coverslip was allowed to cure for 1 hour after which it did not move. Tissue sections were imaged on a Zeiss LSM 710 confocal microscope using a Plan-Apochromat 63x/1.4 NA Oil objective, sampling at a rate of 83 nm in x, y, and 100 nm in the z dimensions with a pixel size of 0.07 μm. Z projections were generated using Zeiss Zen software. ProLong Glass mountant with the higher refractive index of ~1.52 improved the depth of imaging by 40%, allowing nuclei to be imaged 70 μm into the tissue section. Objectives with longer working distance and optimized instrument settings should allow high resolution imaging deeper then 70 μm. A B ProLong Diamond (RI~1.47) ProLong Glass (RI~1.52) Figure 4. FITC photobleach curves with widefield (A) and confocal (B) microscopes. (A) Tubulin in HeLa cells was labeled with mouse anti-tubulin primary antibody, detected with fluorescein (FITC)-labeled goat anti-mouse antibody, and mounted with PBS + 50% glycerol or various commercially available antifade mounting media. Photobleach curves were collected by illuminating the samples for 2 minutes using a 100 watt Hg-arc lamp, imaged using a 20x air objective, then acquired using a 12-bit monochrome camera. The data plotted is the mean florescence intensity of three fields of view over time. (B) Tubulin in HeLa cells were labeled with mouse anti-tubulin primary antibody, detected with fluorescein (FITC)-labeled goat anti-mouse antibody, and mounted with PBS + 50% glycerol or various commercially available antifade mounting media. Photobleach curves were collected using a confocal microscope with a 20x oil-immersion objective scanning regions of interest fifty times with a pixel dwell time of 1.6 microseconds. Excitation source power intensity was set such that ProLong Diamond retained 50% of initial signal intensity at the end of the final scan. Detector gain was held constant for all mounting media. Plotted data is the mean fluorescence intensity from fifteen regions of interest across mounted samples as number of scans. A B ProLong Glass Antifade Mountant 4

Before you begin Storage and handling For regular usage, store the ProLong Glass Antifade Mountant at 4 C, protected from light. For long term storage, you can store the mountant at 20 C. To maximize product lifetime, avoid repeated freeze-thaw cycles. Note: ProLong Glass Antifade Mountant will freeze or become more viscous at temperatures below 0 C. When stored as described, the ProLong Glass Antifade Mountant is stable for at least 6 months from the date of receipt. Important procedural guidelines Use at room temperature: Allow the ProLong Glass Antifade Mountant to warm to room temperature for 1 hour before using it to mount coverslips. Do not shake: Avoid shaking the bottle of ProLong Glass Antifade Mountant to prevent the introduction of air bubbles that can make mounting and imaging difficult. Allow to cure completely to achieve refractive index of 1.52: ProLong Glass Antifade Mountant reaches its maximal refractive index of ~1.52 upon curing as detected by a refractometer. Extra water in and around the specimen will affect the curing time and the refractive index. For specimens thicker then 30 μm, we recommend mounting option B (page 6) or option C (page 6) for optimal results. Apply appropriate spacers, if needed: For thicker specimens, use appropriate spacers to ensure specimen integrity, if needed. Height of the spacers can affect the working distance and curing time, and should be chosen carefully. For immediate viewing: Tack the corners of the coverslip with wax, VALAP, or epoxy. After viewing or imaging, follow the curing instructions. For extended storage: Following curing as described, seal the edges of the coverslip with wax, VALAP, or epoxy, then store the sample in an appropriate slide holder. You can store the samples with minimal loss of antifade performance for up to 1 month at 4 C and up to 3 months at 20 C. If the edges are not sealed properly, moisture in the air, especially in damp environments such as inside a refrigerator, can reduce the refractive index of mounted samples. Not recommended for lipophilic membrane stains: ProLong Glass Antifade Mountant contains glycerol, which may interfere with the use of lipophilic membrane stains such at DiI. Methods Choose one of the following mounting options based on the thickness of the specimen and the allowed curing time. Option A For cultured monolayer cells and tissue sections with a thickness of less than 30 µm (Overnight to 24 hours of total curing time) 1. Warm to room temperature: Allow the mountant to warm to room temperature for 1 hour before mounting specimens. 2. Apply mountant: Remove excess liquid from the sample by gently tapping the edge of the coverslip or slide on a laboratory wipe. For coverslip-mounted specimens: Apply 1 2 drops or 20 60 µl of the mountant directly onto a clean slide, then carefully lower a coverslip onto the mountant to avoid trapping any air bubbles. ProLong Glass Antifade Mountant 5

For slide-mounted specimens: Apply 1 2 drops or 20 60 µl of the mountant directly to the specimen, then carefully lower a coverslip onto the mountant to avoid trapping any air bubbles. 3. Allow to cure overnight: Place the mounted sample on a flat, dry surface, and allow it to cure for 18 24 hours at room temperature in the dark. Option B For specimens 30 100 µm and thicker - Standard curing protocol (48 to 60 hours of total curing time) 1. Warm to room temperature: Allow the mountant to warm to room temperature for 1 hour before mounting specimens. 2. Apply mountant: Remove excess liquid from the sample by gently tapping the edge of the coverslip or slide on a laboratory wipe. For coverslip-mounted specimens: Apply 2 3 drops or 60 100 µl of the mountant directly onto a clean slide, then carefully lower a coverslip onto the mountant to avoid trapping any air bubbles. For slide-mounted specimens: Apply 2 3 drops or 60 100 µl of the mountant directly to the specimen, then carefully lower a coverslip onto the mountant to avoid trapping any air bubbles. 3. Allow to cure: Place the mounted sample on a flat, dry surface, and allow it to cure for 48 to 60 hours at room temperature in the dark. Option C For specimens 30 100 µm and thicker - Fast curing protocol (19 to 27 hours of total curing time) 1. Warm to room temperature: Allow the mountant to warm to room temperature for 1 hour before mounting specimens. 2. Apply mountant: Remove excess liquid from the sample by gently tapping the edge of the coverslip or slide on a laboratory wipe. For coverslip-mounted specimens (recommended): Apply 2 3 drops or 60 100 µl of the mountant directly onto the specimen. Carefully tilt the coverslip back-andforth to distribute mountant evenly over the specimen and the coverslip. You can use the edge of a pipette tip to gently assist in removing any bubbles and spreading the mountant. Proceed to Step 3. Do not place the coverslip on a microscope slide at this point. For slide-mounted specimens: This method is recommended only for specimens 50 µm or less, or if you are planning to use a short working distance objective. Apply 2 3 drops or 60 100 µl of the mountant directly to the specimen. Carefully tilt the coverslip back-and-forth to distribute mountant evenly over the specimen and the coverslip. You can use the edge of a pipette tip to gently assist in removing any bubbles and spreading the mountant. Proceed to Step 3. Do not apply a coverslip to the specimen at this point. 3. Allow to cure overnight: Place the mounted sample on a flat, dry surface, and allow it to cure for 18 24 hours at room temperature in the dark. 4. Apply a thin layer of glycerol or immersion oil: After 18 24 hours, apply 10 30 µl of glycerol or immersion oil across the top of the cured mountant and specimen. Note: Apply just enough glycerol to create a very thin layer across the mounted specimen to adhere the coverslip in place for the next step. The thin layer of glycerol does not seem to change the refractive index for the light path significantly while still allowing the capture of images with minimum optical refraction. ProLong Glass Antifade Mountant 6

5. Apply coverslip to microscope slide: Apply a coverslip to the microscope slide and gently press it into place, tapping to remove bubbles as necessary. Make sure that no air bubbles exist between the mounted sample and the microscope slide. If necessary, apply additional glycerol. The coverslip can be tacked in place with paraffin and imaged immediately; however, the coverslip will begin to set into place over 1 3 hours. Fluorescence microscopy You can image the samples with a fluorescence microscope before the mounting medium cures. However, the refractive index as well as the antifade effectiveness improve following curing for 18 48 hours. When properly handled and stored as recommended, samples can be imaged with minimal photobleaching for up to three months. To further resist photobleaching, minimize the exposure of fluorescently labeled samples to light by using neutral density filters and limit exposure times and exposure intensity. Using LED light cubes from the EVOS microscopy system or similar tools can also be highly beneficial in reducing photobleaching and enhancing sensitivity. ProLong Glass Antifade Mountant is compatible with most fluorescent microscopes and objectives, such as epi-fluorescent, wide-field, confocal, stimulated emission depletion (STED), and structured illumination microscopy (SIM). For best results, we recommend oil immersion objectives with a high numerical aperture. Removal of mounted coverslips Note: If your workflow requires the removal of coverslips for further manipulation or staining of the specimen, we highly recommend that you use the SlowFade Diamond or SlowFade Gold Antifade Mountants. 1. To remove mounted coverslips, place the mounted slide into a Coplin jar with phosphate buffered saline at room temperature and gently agitate overnight. 2. Once the coverslip has detached from the slide, carefully rinse the slide or coverslip with additional PBS or water to remove residual mountant. 3. Carefully note which side of the coverslip or slide contains the specimen before continuing with additional manipulation or staining of the specimen. ProLong Glass Antifade Mountant 7

Appendix Axial resolution and signal intensity Studies show that the axial resolution of a microscopy system can be improved by matching the refractive index (RI) of mounting media, which maximizes light collection by the objective lens. 1 3 Fouquet et al. saw dramatic improvement in axial resolution while using a confocal microscope with high-ri media. 1 ProLong Glass Antifade Mountant is a hard-setting, curing mountant that forms an optical path with minimal optical distortion, because its RI of ~1.52 (after curing) matches that of crown glass used in coverslips. When ProLong Glass mountant with a refractive index of ~1.52 is compared with a mounting medium with a refractive index of ~1.47, the axial resolution is improved by 32% at focal depth of 40 µm and 75% at focal depth of 100 µm. Because the optical light path is improved due to high refractive index, the signal intensity and sensitivity of fluorophores are also observed in deep tissues. The lateral direction resolution is unchanged (Figure 1, page 3). This property makes the ProLong Glass Antifade Mountant an excellent mountant to capture Z-stack and 2-D images of cells and tissues at any depth from 0 μm to 100 μm. Photobleach resistance of mounted fluorophores Table 4. Photobleach resistance of various fluorophores when mounted using ProLong Glass, Diamond, or Gold antifade mountants. Fluorescent dye Ex/Em (nm) Resistance to photobleaching* ProLong Glass ProLong Diamond ProLong Gold Hoechst 350/461 +++ +++ +++ DAPI 345/455 +++ +++ ++ BODIPY FL 505/513 Not tested +++ + Alexa Fluor 488 495/519 +++ ++ ++ Alexa Fluor Plus 488 495/519 +++ ++ + GFP 488/510 ++ ++ Not recommended Fluorescein 494/518 +++ +++ + Cy3 550/570 ++ ++ ++ Alexa Fluor 546 556/575 ++ ++ +++ Tetramethylrhodamine 555/580 ++ +++ + Alexa Fluor 555 555/565 +++ +++ +++ Alexa Fluor Plus 555 555/565 +++ +++ ++ TagRFP 555/584 ++ ++ Not recommended mcherry 575/610 +++ +++ +++ Alexa Fluor 568 578/603 +++ +++ + Texas Red 595/615 +++ +++ +++ Alexa Fluor 594 590/617 +++ +++ +++ TO-PRO -3 642/661 +++ +++ + Alexa Fluor 647 652/668 +++ +++ +++ Alexa Fluor Plus 647 652/668 +++ +++ +++ Cy5 650/670 +++ +++ +++ * Photobleaching resistance was quantified on a Zeiss LSM 710 confocal microscope. HeLa or U2OS cells were stained and mounted using standard immunocytocehmistry (ICC) protocols. Five regions within three fields of view were scanned 15 times with 1.58 μs dwell time per pixel. Excitation wavelength and intensity were optimized by fluorophore. On an epi-fluoresence microsocope using 100-watt Hg-arc lamp, this amount of light/photon exposure will be equal to 60 90 seconds. In the table, +++ designates when 80% or more of signal intensity was left, as compared to initial signal intensity. ++ designates 65 80% remaining signal intensity and + represents 50 65% remaining signal intensity. Not recommended means less than 50% remaining signal intensity. ProLong Glass Antifade Mountant 8

References 1. PLoS ONE 10(3): e0121096. doi:10.1371/journal (2015); 2. Mol Bio of Cell 26, 4075 (2015); 3. Eur Phys J H 38, 281 (2013). Ordering information Cat. No. Product name Unit size P36980 ProLong Glass Hard-set Antifade Mountant... 5 2 ml P36982 ProLong Glass Hard-set Antifade Mountant... 2 ml P36984 ProLong Glass Hard-set Antifade Mountant... 10 ml P36981 ProLong Glass Hard-set Antifade Mountant with NucBlue... 5 2 ml P36983 ProLong Glass Hard-set Antifade Mountant with NucBlue... 2 ml P36985 ProLong Glass Hard-set Antifade Mountant with NucBlue... 10 ml Related products P36934 ProLong Gold Antifade Mountant.... 5 2 ml P10144 ProLong Gold Antifade Mountant.... 2 ml P36930 ProLong Gold Antifade Mountant.... 10 ml P36935 ProLong Gold Antifade Mountant with DAPI... 5 2 ml P36941 ProLong Gold Antifade Mountant with DAPI... 2 ml P36931 ProLong Gold Antifade Mountant with DAPI... 10 ml P36961 ProLong Diamond Antifade Mountant... 5 2 ml P36965 ProLong Diamond Antifade Mountant... 2 ml P36970 ProLong Diamond Antifade Mountant... 10 ml P36962 ProLong Diamond Antifade Mountant with DAPI.... 5 2 ml P36966 ProLong Diamond Antifade Mountant with DAPI.... 2 ml P36971 ProLong Diamond Antifade Mountant with DAPI.... 10 ml S36937 SlowFade Gold Antifade Mountant... 5 2 ml S36936 SlowFade Gold Antifade Mountant... 10 ml S36939 SlowFade Gold Antifade Mountant with DAPI... 5 2 ml S36938 SlowFade Gold Antifade Mountant with DAPI... 10 ml S36963 SlowFade Diamond Antifade Mountant... 5 2 ml S36967 SlowFade Diamond Antifade Mountant... 2 ml S36972 SlowFade Diamond Antifade Mountant... 10 ml S36964 SlowFade Diamond Antifade Mountant with DAPI.... 5 2 ml S36968 SlowFade Diamond Antifade Mountant with DAPI.... 2 ml S36973 SlowFade Diamond Antifade Mountant with DAPI.... 10 ml ProLong Glass Antifade Mountant 9

Documentation and support Customer and Technical Support Visit thermofisher.com/support for the latest in services and support, including: Worldwide contact telephone numbers Product support, including: Product FAQs Software, patches, and updates Training for many applications and instruments Order and web support Product documentation, including: User guides, manuals, and protocols Certificates of Analysis Safety Data Sheets (SDSs; also known as MSDSs) Note: For SDSs for reagents and chemicals from other manufacturers, contact the manufacturer. Limited Product Warranty Life Technologies Corporation and/or its affiliate(s) warrant their products as set forth in the Life Technologies General Terms and Conditions of Sale found on Life Technologies website at www.thermofisher.com/us/en/home/global/terms-and-conditions.html. If you have any questions, please contact Life Technologies at thermofisher.com/support. The information in this guide is subject to change without notice. For Research Use Only. Not for use in diagnostic procedures. DISCLAIMER: TO THE EXTENT ALLOWED BY LAW, LIFE TECHNOLOGIES AND/OR ITS AFFILIATE(S) WILL NOT BE LIABLE FOR SPECIAL, INCIDENTAL, INDIRECT, PUNITIVE, MULTIPLE OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH OR ARISING FROM THIS DOCUMENT, INCLUDING YOUR USE OF IT. Revision history: Pub. No. MAN0017262 Revision Date Description A.0 07 September 2017 New user guide Important Licensing Information: These products may be covered by one or more Limited Use Label Licenses. By use of these products, you accept the terms and conditions of all applicable Limited Use Label Licenses. Manufacturer: Life Technologies Corporation 29851 Willow Creek Road Eugene, OR 97402 Trademarks: All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. Cy is a registered trademark of GE Healthcare UK Limited. Zeiss is a registered trademark of Carl Zeiss AG. 2017 Thermo Fisher Scientific Inc. All rights reserved. 07 September 2017