civil product range JUNCTION BOXES DUCT CHANNELS AND COVERS Gas Line Cover Slabs ESB Railways ROAD GULLY AND LIDS

Similar documents
MANHOLES PART I: GENERAL. A. Precast Concrete Manholes

Engineering and Construction Services Division Construction Drawings for Sewers and Watermains. T No. Revision T No. Revision Remarks All T drawings

STANDARD CATCH BASIN GUTTER LINE CB INLET FRAME & GRATE, GROUTED TO GRADE RINGS AS REQ'D CONCRETE CURB FINISHED GRADE ASPHALT MAX 50 MIN

ABOUT INLAND. Tannis Karklin, E.I.T Technical Sales and Marketing

DESIGN GUIDELINES (SD) COUNTY OF ALAMEDA PUBLIC WORKS AGENCY 399 ELMHURST STREET HAYWARD, CA

Cooke Precast Concrete

Pipe Product Catalog Table of Contents

Cooke Precast Concrete

Manhole or Catch Basin Type A & B Cone Sections Precast - Design F Manhole or Catch Basin Cover (Reducer Cone Section Precast) Design D

2. Remove from the Standard Plate manual: Standard Plate Index, Sheets 1-4 of 4, Numerical Index of Standard Plates (August 31, 2012)

Standard Specifications

Standard Plate 7036 is discontinued. It is replaced by Standard Plan Pedestrian Curb Ramp Details.

TIMARU DISTRICT COUNCIL 2 King George Place P.O. Box 522 Timaru 7940 Telephone: Website:

DIVISION APPROVED MATERIAL LIST AND STANDARD DETAILS

SUBJECT: Standard Plate Turf Establishment Areas (at Pipe Culvert Ends)

City of Vaughan Engineering Department DESIGN STANDARD DRAWINGS

C-M TMR Products Index

INSTRUCTIONS: 1. Record the transmittal letter number, date, and subject on the transmittal record sheet located in the front of the manual.

SUBJECT: Standard Plate 9102 Turf Establishment Areas At Pipe Culvert Ends

TOWN of LAKESHORE SITE PLAN CHECKLIST

SUBJECT: Standard Plates 4132, 4155, Drainage Structures and Castings Info

MSD STANDARD DRAWINGS LOUISVILLE AND JEFFERSON COUNTY METROPOLITAN SEWER DISTRICT 700 WEST LIBERTY STREET LOUISVILLE, KENTUCKY

PART 4 STANDARD DRAWINGS FOR CONSTRUCTION

SUPPLEMENTARY STANDARD DETAIL DRAWINGS

SECTION ELECTRICAL IDENTIFICATION

SECTION MANHOLES

Cooke Precast Concrete

CONCRETE MANHOLES.

MH Table of Contents Standard Title/Scope Page Table of Contents SCE Public

Manholes Table of Contents

SECTION 8: DRAINAGE, SEWER AND WATER SUPPLY NETWORKS

SECTION 095 SPECIFICATIONS DETAIL DRAWINGS. Index of Detail Drawings

STATE WHEN ORDERING HI =...

Risk Assessment & Safe Working Practice

SECTION 39 - MANHOLES TABLE OF CONTENTS

REGISTRATION EXAMINATION, JUNE 2008 DRAINLAYING ANSWER SCHEDULE

MAINTENANCE HOLES, CATCH BASINS AND DITCH INLETS - MTC FORM 407 INDEX

STORM M ANHOLE FOR 42" PIPE AND SM ALLER JOB NO. SHEET NO. DATE MARCH 2015 OF MIN OF 3 CRSES MAX OF 5 CRSES 30"MAX 3 OR 3.5 PRECAST ECCENTIC CONC

24" Dia. 36" Dia. WE BUILD CONFIDENCE

STANDARD DRAWINGS INDEX MODIFIED FOR CENTRAL REGION Revised August 6, 2018

Cablelink Plus Flush Technical

SOUTH AFRICAN NATIONAL STANDARD

Miscellaneous. Demolition

SECTION III STANDARD DRAWINGS ROYSE CITY GENERAL CONSTRUCTION NOTES & DETAILS

Government Of Newfoundland & Labrador Municipal Water, Sewer And Roads Master Construction Specifications

Anti-Trust Statement

STANDARD AND EXAMPLE DRAWINGS

Appendix C Construction Details

Current Standard Plates including Transmittal Letters are available on the web at:

D. Thermally Sprayed Metallic Coating (Flame Spray): STD SPEC

RECORD DRAWINGS REVISED TO CONFORM TO CONSTRUCTION RECORDS PROVIDED BY CONTRACTOR GMG BY DATE 11/13 CRS NO.

CITY OF VISTA STANDARD DRAWINGS

UTILITY AND STREET CONSTRUCTION PLAN REQUIREMENTS SECTION 1

Utility Structures. Utility vaults, trenches, transformer pads Electrical Pole Bases and switching cubicles

CITY OF VISTA STANDARD DRAWINGS

ROOM smooth cement f.f FLOOR LAYOUT

CONSTRUCTION SPECIFICATION FOR MAINTENANCE HOLE, CATCH BASIN, DITCH INLET, AND VALVE CHAMBER INSTALLATION

The Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 8

Bracket guide. LK Pipe Pole. LK Radiator fixture Uni

Customer Connection Guide Updates Effective May 2017

Hollow Stem Auger Modifications

kilform

Oakdale Primary School, Peterborough Civil Engineering NBS Specification

Locator Accessories DATA SHEETS. Accessory Range for Pipe & Cable Location Equipment

METRIC LIGHTNING PROTECTION PRODUCTS

G.J. FIRE HYDRANT BOX - TYPE 5 - SABS

Current Standard Plates including Transmittal Letters are available on the web at:

Khathij Industrial Fasteners

Z1035, Z1036, & Z1903 FLOOR DRAIN & CLEANOUT INSTALLATION STABILIZER

Introduction. Classifications of piping: Industrial. Residential (i.e., plumbing) Carries liquids and gases used in the manufacture of products

Typical Drawings for Schools

SECTION COMMON WORK RESULTS FOR HVAC

M I N N E S O T A D O T BID TABULATION SUMMARY JOB PAGE 1 ON 01/14/97 MINNESOTA PROJECT NO.S: DPI 015-8(021) DPI 015-8(022)

Football Goals 7,32x2,44 m

netball netball Socketed International Freestanding International Floor Fixed International Wheelaway Posts Practice Posts Rings

EXCAVATION AND BACKFILL

Junction boxes. Surface mounting - IP44 - IP55 - IP56 TECHNICAL CHARACTERISTICS

B422 - PRECAST REINFORCED CONCRETE BOX CULVERTS AND BOX SEWERS - OPSS 422

Raised Floor system LIMOGES Cedex. Phone : Fax :

SECTION UNDERGROUND POWER DUCT AND SUB-STRUCTURES. A. Section : Trenching, Backfilling, and Compacting

Standard Plate Sheer Reinforcement for Precast Drainage Structures has been updated upon recommendation of the Bridge Office.

Section E NSPS MODEL STANDARDS FOR TOPOGRAPHIC SURVEYS Approved 3/12/02

CSP PSYCHIATRIC SERVICES UNIT SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

Flush Floor system LIMOGES Cedex. Phone : Fax :

Outdoor equipment. Barrier posts. Stainless steel. Barrier elements. Barrier poles. Outdoor equipment - pages

F-5-1a. Concrete Bollards (Detail 1 of 2) WEIGHT: 166kg. WEIGHT: 227kg. WEIGHT: 113kg. WEIGHT: 212kg

Thru Wall Floor Seals For New Installation

Plate 8132A - Preformed Rigid PVC Conduit Loop Detector, is a new plate requested by OTST.

This specification describes the minimum requirements for piping systems for the following service:

Industrial Pipe Marking

International Tube & Conduit Company Ltd. BRITISH STANDARD STEEL CONDUITS & FITTINGS

Piping & Equipment Identification

SECTION TRACER WIRE FOR NONMETALLIC PIPE

MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C

PRODUCT CATALOGUE. Saskatchewan

LETTING : CALL : 029 COUNTIES : GOODHUE

SECTION MANHOLES

6. Internal lightning protection

SECTION PRECAST CONCRETE SECTIONAL MANHOLES

Wiring ducts Easily allows for organization, pulling and separation of cables

Transcription:

kilform civil product range ESB CCTV Eircom Services Lighting Risers DUCT CHANNELS AND COVERS Gas Line Cover Slabs ESB Railways ROAD GULLY AND LIDS Untrapped Gully Trapped Gully Large Trapped Gully Headwalls Gully Risers Cast Iron Free Flow Lids MARKER POSTS, SLABS AND PLATES Round Top Marker Post Flat Top Marker Post Square Head Marker Post Electrical Marker Post MISCELLANEOUS Retaining Wall Blocks Lamp Post Base Duct Marker Post Duct Marker Blocks Hydrant and Water Plates Earth Rod Box Specials made to order

REFERENCE SIZE MM A x B x C HOLES 4 WAY HOLES 3 WAY HOLES 2 WAY HOLES KNOCK OUT STANDARDS NOTICE: Killeshal Precast Services Boxes are manufactured to comply with EN1917:2004 Concrete manholes and inspection chambers unreinforced, steel fibre and reinforced. WEIGHT KG J/B 3 640 x 1110 x 800 535 J/B 4 640 x 1110 x 800 646 J/B 5 960 x 1270 x 895 1066 J/B 9 440 x 590 x 400 90 J/B 10 440 x 590 x 400 45 J/B 11 420 x 540 x 220 46 J/B 12 850 x 850 x 950 826 J/B 15 890 x 1450 x 950 1215 J/B 18 1150 x 1150 x 850 1046 J/B 21 1150 x 1450 x 850 1200 J/B 24 450 x 700 x 650 328 J/B 25 1000 x 1600 x 1040 1515 J/B 26 1290 x 1310 x 1150 1600 J/B 27 1190 x 1210 x 870 1113 J/B 28 740 x 1210 x 900 758 J/B 29 740 x 1210 x 900 851 J/B 30 1075 x 1150 x 1050 1155 J/B 31 875 x 950 x 900 795 J/B 33 800 x 1400 x 895 870 J/B 34 1090 x 1110 x 1000 1088 J/B 35 1075 x 1150 x 1050 838 2

COLOUR CODE BURIED PLASTIC PIPING I.S. 370: 2007 Electricity ducting Public lighting Street furniture / signal below 125 Volt Gas pipe Buried potable water Sewer Storm and road drain smooth external wall duct Storm and road drain corrugated Telecom / fibre optic smooth external wall duct Telecom / fibre optic corrugated dud only- Maximum pipe outside diameter 175 mm Any colour except Red or Yellow Junction Boxes Section ***Colour may very depend on application STANDARDS NOTICE: Killeshal Precast Services Boxes are manufactured to comply with EN1917:2004 Concrete manholes and inspection chambers unreinforced, steel fibre and reinforced. eircom JUNCTION BOX 3 eircom JUNCTION BOX 4 640 x 1110 x 800mm 640 x 1110 x 800mm Other sizes available contact Killeshal s customer service on Ref: eircom J/B 3 Reinforced walls. eircom approved. Ref: eircom J/B 4 Easily knockout polystyrene cable entry point/can be supplied with 12/no x 150mm dia straight through entry points (4/no or 1. no side wall, 4/no on each cable end). Easily manoeuvred with lifting eyes. eircom JUNCTION BOX 28 eircom JUNCTION BOX 29 740 x 1210 x 900mm 740 x 1210 x 900mm Ref: eircom J/B 28 Ref: eircom J/B 29 3

ESB MINI PILLAR JUNCTION BOX 5 960 x 1270 x 895mm Reinforced walls. 100 mm shoulder to facilitate increasing the depth. Drainage Sump. Easily manoeuvred. Multiple cable entry points. Integrated, reinforced base. 450 x 700 x 650mm Ref: J/B 5*** JUNCTION BOX 24 JUNCTION BOX 9 JUNCTION BOX 10 JUNCTION BOX 11 HEAVY DUTY VALVE CHAMBER 440 x 590 x 400mm HEAVY DUTY VALVE CHAMBER 440 x 590 x 200mm Ref: J/B 10 Ref: J/B 9 Ref: J/B 24*** 420 x 540 x 220mm Ref: J/B 9 Ref: J/B 10 Ref: J/B 11 JUNCTION BOX 12 JUNCTION BOX 15 JUNCTION BOX 18 JUNCTION BOX 21 MANHOLE BOX 850 x 850 x 950mm MANHOLE BOX 890 x 1490 x 950mm MANHOLE BOX 1150 x 1150 x 850mm MANHOLE BOX 1150 x 1450 x 850mm Frame Ref: J/B 13 Frame Ref: J/B 16 Frame Ref: J/B 19 Frame Ref: J/B 22 Ref: J/B 12 Ref: J/B 15 Ref: J/B 18 Ref: J/B 21 Base Ref: J/B 14 Base Ref: J/B 17 Base Ref: J/B 20 Base Ref: J/B 23 ***Colour may very depend on application see page 2 4

1000 x 1600 x 1040mm JUNCTION BOX 25 Reinforced concrete walls. Preformed cable entry points. Integrated reinforced base. Base incorporating sump. Easily manoeuvred with lifting hooks. Ironmongery fitted. For J/B 25 without base see J/B 33 Ref: J/B 25*** NRA RCD/500/54 JUNCTION BOX 26 1290 x 1310 x 1150mm Reinforced concrete walls. Preformed cable entry points. Integrated reinforced base. Splayed base to aid stability. Easily manoeuvred. Base incorporating sump. 1190 x 1210 x 870mm Ref: J/B 26*** JUNCTION BOX 27 For J/B 26 without base see J/B 34 High adjusting riser to suit see J/B 502 For J/B 27 without base see J/B 35 High adjusting riser to suit see J/B 502 SUBGRAGE DBR % TABLE FOR J/B 25, J/B 26, J/B 27 BLINDING AND EMBEDDING REQUIREMENTS IN ACCORDANCE WITH HD 25/95 SUB-BASE THICKNESS MM Ref: J/B 27*** EDGE DISTANCE FROM BOX TO EDGE BLINDING MM SUB-BASE MATERIAL >5 225 225 GRANULAR MATERIAL (TYPE2) 5<CBR<3 300 300 GRANULAR MATERIAL (TYPE2) 3<CBR<2 350 300 GRANULAR MATERIAL (TYPE2) <2 600-1000 300 600MM OF CAPPING (6F1 OR 6F2) OVERLAID BY A GRANULAR SUB-BASE (TYPE2) UP TO 400MM IF REQUIRED ***Colour may very depend on application see page 2 5

800 x 1400 x 895mm For J/B 33 with base see J/B 25 High adjusting riser to suit see J/B 502 JUNCTION BOX 33 1090 x 1110 x 1000mm JUNCTION BOX 34 Ref: J/B 33*** For J/B 34 with base see J/B 26 High adjusting riser to suit see J/B 502 JUNCTION BOX 31 JUNCTION BOX 30 875 x 950 x 900mm 1075 x 1150 x 1050mm For J/B 31 with base see J/B 30 1075 x 1150 x 1050mm For J/B 35 with base see J/B 27 High adjusting riser to suit see J/B 502 JUNCTION BOX 35 For J/B 30 without base see J/B 31 Ref: J/B 34*** Ref: J/B 35*** High adjusting riser to suit see J/B 501 High adjusting riser to suit see J/B 501 Ref: J/B 31*** Ref: J/B 30*** JUNCTION BOX RISER J/B 501 JUNCTION BOX RISER J/B 502 875 x 950 x 150mm Riser if required - J/B 31 for high adjustment - J/B 30 1090 x 1110 x 100mm Riser if required - J/B 26 for high adjustment - J/B 27 - J/B 34 - J/B 35 Ref: J/B 501 Ref: J/B 502 ***Colour may very depend on application see page 2 6

370 x 490 x 610mm DUCT CHANNEL 105 DUCT CHANNEL 108 DUCT COVER Ref: D/C 173 215 x 285 x 915mm DUCT COVER Ref: D/C 126 Ref: D/CH 105 DUCT CHANNEL 111 DUCT CHANNEL 117 350 x 765 x 1497mm 340 x 448 x 1000mm DUCT COVER Ref: D/C 209 Ref: D/CH 108 DUCT CHANNELS AND COVERS Ref: D/CH 111 DUCT CHANNEL 114 DUCT CHANNEL 115 170 x 440 x 1000mm 170 x 280 x 1000mm DUCT COVER Ref: D/C 260 SPILLWAY CHANNEL 116 343 to 450 x 710 x 895 x 1000mm Ref: D/CH 114 DUCT COVER Ref: D/C 262 1820 x 1037 x 2000mm HEADWALLS Ref: D/CH 117 Ref: D/CH 115 Other sizes available contact Killeshal s customer service on Ref: D/CH 116 GAS LINE COVER SLABS 1450 x 100mm 1450 x 150mm 1450 x 200mm Ref: M/127 Ref: D/C 242 Ref: D/C 199 Ref: D/C 228 7

UNTRAPPED GULLY UNTRAPPED GULLY (800x380x445mm) Ref: G/1 Ref: G/1 + G/R 104 TRAPPED GULLY TRAPPED GULLY (800x500x375mm) Ref: G/1 + G/R 104 + C/250 (G/9) ROAD GULLY AND LIDS Ref: G/2 Ref: G/2 + G/R 104 LARGE TRAPPED GULLY LARGE TRAPPED GULLY (805x585x450mm) Ref: G/2 + G/R 104 + C/250 (G/9) 970x970x85mm 750x650x100mm - G/5 Ref: G/5 GULLY RISERS 750x650x100mm - G/5 Ref: G/5 + Ref: G/5 + G/R 103 + C/250 (G/9) G/R 102 + C/400 (G/10) 610x610x100mm - G/1 - G/2 CAST IRON FREE FLOW LIDS 527x527x100mm - G/5 515x395x75mm - G/1 - G/2 - G/5 Ref: G/R 101 Ref: G/R 102 Ref: G/R 103 Ref: G/R 104 Ref: D/400 (G/10) Ref: D/250 (G/9) 8

MARKER POSTS AND SLABS marker posts are placed at or behind location points for services such as AV/SV, hydrant chambers, water and gas chambers, electric cable junctions and field markers as markers for emergency services or service engineers buried hazard warning marker slabs which shadow electricity lines and gas pipes, helping to avoid breaches and health and safety incidents ROUND TOP (300x100x1090mm) *Plates see below FLAT TOP (270x80x1220mm) *Plates see below SQUARE HEAD (75x100x1230mm) *Plates see below DUCT (110x140x1600mm) MARKER POSTS & PLATES DUCT MARKER BLOCK (300x300x225mm) Ref: M/POST 101 Ref: M/POST 102 Ref: M/POST 116 Ref: M/POST 111 ELECTRICAL (180x50x935mm) DUCT MARKER BLOCK (300x300x225mm) DUCT MARKER BLOCK (300x300x225mm) Ref: M/POST 105 EARTH ROD BOX (325x325x150mm) Ref: M/POST 113 Ref: M/POST 114 Ref: M/POST 115 HYDRANT PLATES *Made to suit each individual requirements PLATES WATER PLATES *Full range of plates available Ref: M/123 MISCELLANEOUS RETAINING WALL BLOCKS 1400 x 695 x 795mm Ref: M/112 LAMP POST BASE 700 x 700 x 700mm * 1200 x 1200 x 1200mm also available Ref: IR/11 For Line Drainage See Pre-Fabricated Drainage System Catalogue 9

UK OFFICE Tel: 0800 0393367 Email: sales@killeshalprecast.co.uk Web: killeshalprecast.co.uk R. I OFFICE Tel: +353 (0)57 9353018 Email: sales@killeshal.com Web: killeshal.com