CALIBRATED IMPULSE GENERATOR MODEL CIG khz 1 GHz

Similar documents
BROADBAND PREAMPLIFIER MODEL BPA khz 1 GHz

LOG PERIODIC ANTENNA MODEL LPA MHz - 1 GHz

PARALLEL ELEMENT ANTENNA MODEL PEA-30

POWER LINE IMPEDANCE STABLIZATION NETWORK (LISN) MODEL PLISN-25/2. 5 khz 1 GHz

OMNI-DIRECTIONAL WIDEBAND ANTENNA MODEL EM GHz - 18 GHz

BICONICAL ANTENNA MODEL BIA MHz 200 MHz

LOOP ANTENNA MODEL ALR-30M. 9 khz 30 MHz

REMOTE LOOP ANTENNA MODEL ALR khz 30 MHz

ELECTRIC FIELD PROBE ANTENNA MODEL PEF-10A. 20 Hz 1 MHz

PARABOLIC ANTENNA MODEL MTA GHz 10.0 GHz

INSTRUCTION MANUAL TRI-PLATE LINE MODEL EM-7310

Model 7000 Low Noise Differential Preamplifier

Broadband Power Amplifier

Model 4007DDS. 7 MHz Sweep Function Generator

COMBILOG ANTENNA MODEL AC MHz. rev: 0202

INSTRUCTION MANUAL. March 11, 2003, Revision 3

Instruction Manual Model M Switch, DPDT, Manual Select

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

Model 1791 VHF Radio User's Manual

Model 4402B. Ultra-Pure Sinewave Oscillator 1Hz to 110kHz Typical Distortion of % Serial No. Operating Manual

Model Hz to 10MHz Precision Phasemeter. Operating Manual

MODEL 3810/2 Line Impedance Stabilization Network

COM-POWER OPERATION MANUAL ACS W

CT-2 and CT-3 Channel Taggers OPERATION MANUAL

3100LA Broadband Power Amplifier

CIRCUIT-TEST ELECTRONICS

411LA Broadband Power Amplifier

Current Probes. User Manual

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

MFJ SIGNAL ENHANCER II

Operation and Service Manual. 350 MHz Preamplifier SIM914. Stanford Research Systems

2100L Broadband Power Amplifier

A 500 Broadband Power Amplifier

COUPLING DECOUPLING NETWORK MODEL CDN-AF4

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

OPERATING MANUAL CAVITY DUMPER / PULSE PICKER DRIVER MODEL NUMBER: 643ZZ.ZZZ-SYN-Y-X

Advanced Test Equipment Rentals ATEC (2832)

Opus 21 s80 Integrated Amplifier Owner's Manual

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

Model 310H Fast 800V Pulse Generator

TLS-3A. Telephone Line Simulator. User Manual , Rev. B Covers Model TLS-3A-01

SDI SPECTRADYNAMICS, INC. LOW NOISE FREQUENCY REFERENCE OPERATING MANUAL

HydroLynx Systems, Inc.

1140LA Broadband Power Amplifier

MZ2 HEADPHONE AMPLIFIER, PREAMP, & STEREO AMPLIFIER USER GUIDE

Models 1421 and 1422 User s Manual. Broadband Amplifiers

KeyPre KP6 - Electronic Instrument Preamplifier

léìë=on ëpm=fåíéöê~íéç=^ãéäáñáéê lïåéêdë=j~åì~ä êéëçäìíáçå

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

DUAL LEVELAR. Two Channel Tube Compressor/Leveling Amplifier

Power Probe Model PP115

Series 3000 Model R-107A

PI-10 Broadband Power Indicator

INSTRUCTION MANUAL MODEL 2779 SUBCARRIER MODULATOR

About JFW Industries, Inc.

MODEL W Power Amplifier

MODEL 25D MANUAL PRODUCT OVERVIEW:

Data Sheet SC5317 & SC5318A. 6 GHz to 26.5 GHz RF Downconverter SignalCore, Inc. All Rights Reserved

Model 34A. 3Hz to 2MHz 2-Channel Butterworth/Bessel HP, LP, BP, BR Plug-In Filter Card for Model 3905/3916 Chassis.

PI-150 Broadband Power Indicator

User Guide. Digital AC/DC Clamp Meter Model 38394

User s Guide. Digital AC/DC Clamp Meter Model 38394

200Amp AC Clamp Meter + NCV Model MA250

INSTRUCTION MANUAL MODEL 2455T SUBCARRIER MODULATOR

TA MHz oscilloscope probe TA MHz oscilloscope probe

EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

LINCO MEASUREMENT MODEL CP-2B MASTER METER PROVER COUNTER INSTRUCTION MANUAL

INSTRUCTION MANUAL MODEL 4010A. 2 MHz FUNCTION GENERATOR MANUAL DE INSTRUCCIONES MODELO 4010A. 2MHz GENERADOR DE FUNCIONES

Localizer provides signal generation over the Localizer band of to MHz with 90 Hz and 150 Hz tones, amplitude modulated

Signal Forge 2500M Frequency Expansion Module. 1.5 GHz to 2.6 GHz. User Manual

Process Calibrator. TechChek 820

Log Periodic Antenna

Advanced Test Equipment Rentals ATEC (2832)

TIA-4000 Optical/Electrical Converter. Operating Instructions

Owner s Manual.

Thruline RF Directional Wattmeters

Model 8140VT VERSATAP INSTALLATION AND OPERATION MANUAL

INSTRUCTION SHEET WIDEBAND POWER SENSOR MODEL Copyright 2008 by Bird Electronic Corporation Instruction Book P/N Rev.

Utilizzo del Time Domain per misure EMI

Model Quality in Test and Measurement Since 1949 OUTSTANDING PERFORMANCE DESCRIPTION APPLICATIONS ADDITIONAL FEATURES

Additional JFW Brochures

ASX SERIES PACIFIC OPERATION MANUAL AC POWER SOURCE POWER SOURCE

Broadband Current Probe Series Operation Manual

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

IFR 4000 Portable Nav/Comm Test Set

MODEL FS-4 INSTRUCTION MANUAL R.L. DRAKE COMPANY, MIAMISBURG, OHIO, U.S.A.

TIA-3000 Optical/Electrical Converter. Operating Instructions

INSTRUMENTS, INC. Model 2960AX Disciplined Quartz Frequency Standard 2960AX. Section Page Contents

Multi-Couplers And Distribution Amplifiers 0.5 MHz to 18 GHz

NANOSECOND PULSE GENERATOR NPG-15/2000(N) USER MANUAL

User s Guide. 400A AC/DC Clamp Meter. Model MA220

Model 3725/2M. Line Impedance Stabilization Network (LISN) User Manual

Amplified High Speed Photodetectors

ADA416-XLR DISTRIBUTION AMPLIFIERS OPERATING AND MAINTENANCE MANUAL

TIA-1200 Optical/Electrical Converter. Operating Instructions

Random & Sinusoidal Jitter Injector. Main Unit Operation Manual

HQ-31 HQ-15 USER S GUIDE SINGLE CHANNEL 31 BAND 1/3 OCTAVE GRAPHIC EQUALIZER DUAL CHANNEL 15 BAND 2/3 OCTAVE GRAPHIC EQUALIZER

Advanced Test Equipment Rentals ATEC (2832)

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

Agilent 8473B/C Crystal Detector. Operating and Service Manual

Transcription:

INSTRUCTION MANUAL CALIBRATED IMPULSE GENERATOR MODEL CIG-25 10 khz 1 GHz

INSTRUCTION MANUAL THIS INSTRUCTION MANUAL AND ITS ASSOCIATED INFORMATION IS PROPRIETARY. UNAUTHORIZED REPRODUCTION IS FORBIDDEN. 1995 ELECTRO-METRICS CORP. CALIBRATED IMPULSE GENERATOR 10 khz 1 GHz ELECTRO-METRICS MODEL CIG-25 SERIAL NO: N/A ELECTRO-METRICS CORPORATION 231 Enterprise Road, Johnstown, New York 12095 Phone: (518) 762-2600 Fax: (518) 762-2812 EMAIL: info@emihq.com WEB: http://www.electro-metrics.com MANUAL REV. NO: CIG25-0895 ISSUE DATE: AUGUST 01 1995

WARRANTY This Model CIG-25 Calibrated Impulse Generator is warranted for a period of 12 months (USA only) from date of shipment against defective materials and workmanship. This warranty is limited to the repair of or replacement of defective parts and is void if unauthorized repair or modification is attempted. Repairs for damage due to misuse or abnormal operating conditions will be performed at the factory and will be billed at our commercial hourly rates. Our estimate will be provided before the work is started.

TABLE OF CONTENTS SECTION TITLE PAGE 1.0 Introduction 1 2.0 Specifications 1 2.1 Electrical 1 2.2 Mechanical 1 3.0 Power Supply 2 3.1 Power Requirements 2 3.2 Power Source Selector 2 3.3 Fuse Specifications 2 4.0 4.1 Description Front/Rear Panel Front Panel 3 3 4.2 Rear Panel 4 5.0 Operating Procedure 4 5.1 Initial Power-Up Procedure 4 5.2 Operating Instructions 4 6.0 Applications 5 ILLUSTRATIONS TITLE NUMBER PAGE 1.0 CIG-25 Correction Factor Chart 7 (EM4320-i)

OPERATION AND USE CALIBRATED IMPULSE GENERATOR ELECTRO-METRICS MODEL CIG-25 1.0 Introduction The Electro-Metrics Model CIG-25 Calibrated Impulse Generator produces calibrated impulses at variable repetition rates from 10 khz to 1000 MHz. The repetition rate is variable between 1 Hz and 100 Hz (1 Hz steps--1 to 10 Hz, 10 Hz steps--10 to 100 Hz) from 10 khz to 1000 MHz. The impulse level is variable in 1 db steps from 0 to 90 db(µv/mhz) with an accuracy of ±1.0 db for the level selected and a flatness of ±0.5 db over the calibrated frequency range. The pulse width is approximately 0.2 nsec (0.2 x 10-9 sec.), while a fixed internal attenuator ensures a VSWR not exceeding 1.7:1. Additional features are: a. The unit can be synchronized with and operated at the AC line frequency. b. Single pulse (manual) operation. c. Selection of either positive or negative polarity impulse to facilitate checking for possible overloads of a device or unit under test. 2.0 Specifications 2.1 Electrical Frequency Range (calibrated): Repetition Rate: Calibrated Output Level: 10 khz to 1000 MHz. 1 Hz to 100 Hz. 0 to +90 db(µv/mhz). Average VSWR: 1.7:1. Impedance: Output Connector: Matched to 50 ohms. TNC, female. 2.2 Mechanical Length: 302 mm (11 7/8\"). Width: 208 mm (8 3/16"). Height: 148 mm (5 13/16"). Weight: 2.7 kg (6 lbs). (CIG25-1)

3.0 Power Supply 3.1 Power Requirements a. AC Power Sources: 1) 105-130 VAC, 50-400 Hz. 2) 210-230 VAC, 50-400 Hz. 3.2 Power Source Selector The Power Source Selector is incorporated as part of the power input connector. The number visible in the window indicates the nominal AC power source for which the receiver is set. To change the power source setting: a. Remove the power cord from the connector plug. b. Pull the handle marked FUSE PULL and remove the fuse. c. Rotate the handle down and gently pull the printed circuit voltage selector card from its slot. d. Orient the card so that the desired operating voltage appears on the bottom-left side. e. Firmly push the voltage selector card back into its slot. f. Rotate the FUSE PULL handle up and install the correct rating fuse. g. Reconnect the AC power cord to the connector. CAUTION Verify that the Power Source Selector setting corresponds to the AC power source being used. Operation on "220" VAC with the module set for "110" VAC can cause extensive circuit damage. 3.3 Fuse Specifications The CIG-25 uses the following fuses: a. 115 VAC operation: 1/8 AMP 3AG TIME-DELAY. (CIG25-2)

b. 230 VAC operation: 1/16 AMP 3AG TIME-DELAY. 4.0 Description Front/Rear Panel 4.1 Front Panel a. Power Switch Type: Two position toggle switch. Function: Self-explanatory. b. Power On Indicator Type: LED. Color: Amber. Function: Self-explanatory. c. Repetition Rate Select Switch Type: Four (4) position rotary. Function: To select either X10, X1, Line Synchronized, or Manual (MAN) mode of impulse repetition rate. c1. Repetition Rate Multipication Select Switch Type: Ten (10) position rotary. Function: To select the multiplication factor to be used in conjuction with the X1 and X10 positions of the Repetition Rate Select Switch. c2. Manual Impulse Switch Type: Momentary Pushbutton. Function: In the Manual position of the Repetition Rate Select Switch, used to manually generate the impulse output. d. Output Level Select Switches Type: Nine (9) and ten (10) position rotary. Function: To set the output level of the impulse signal from 0 to 90 db(µv/mhz) in 1 db steps. e. Polarity Select Switch Type: Two position toggle switch. (CIG25-3)

Function: To select either a positive or negative polarity for the impulse signal being generated. f. Output Connectors 4.2 Rear Panel Type: TNC, female. Function: Self-explanatory. a. Power Input Connector Type: Combined voltage selector and fuse holder. Function: Self-explanatory. 5.0 Operating Procedure 5.1 Initial Power-Up Procedure a. Before applying power to the CIG-25 check the following: 1) The CIG-25 must be in an up-right position to function properly. 2) Power Source Selector setting should correspond to the AC power source being used. 3) The fuse should be the correct rating for the AC power source being used. b. Connect the power cord between the J1 POWER Connector and the AC power source selected. c. Push the POWER Switch in, the POWER ON light should come on. Allow a minimum warm-up time of 30 minutes. 5.2 Operating Instructions a. Power-up the instrument following the procedure in Paragraph 4.1. b. Use a 50-ohm coaxial cable to connect the output of the CIG-25 to the input of the receiver being calibrated. Frequency range of the receiver must be within the 10 khz to 1000 MHz range of the CIG-25. In addition, the CIG-25 must work into a 50-ohm load impedance for accurate results. c. The output level in db(µv/mhz) is the sum of the front panel attenuator settings. d. Set the polarity (positive or negative) of the output pulse to the setting required using the front panel POLARITY Switch. (CIG25-4)

When operating with broadband impulse noise, care should be taken to prevent receiver overload. This is easily detected by noting the receiver output readings obtained for positive and negative pulses of the same amplitude level. The CIG-25 output level does not change with polarity; thus, any change in receiver output is caused by overloading of the receiver input circuitry. The input stage often is receiving a strong signal although the receiver output may be low. It is recommended, therefore, to set the receiver gain high and keep the CIG-25 amplitude level low. If receiver overload cannot be prevented in this manner, the use of a low-pass filter is recommended. The filter should have a cut-off frequency slightly above the highest intended operating frequency. 6.0 Applications The CIG-25 Calibrated Impulse Generator is an ideal calibration standard for use with RF noise meters and EMI receivers. It can also be used for receiver alignment, bandwidth measurements, and for checking transient response. When used with a receiver equipped with a "slideback control", the indicating meter of the receiver is adjusted so that the unknown impulsive signal or noise is just above the cut-off point. The unknown impulsive signal or noise is then disconnected and the output of the CIG-25 connected to the receiver. Its level is then adjusted to match that of the unknown impulsive signal or noise, the level of the unknown signal is equal to that of the CIG-25. NOTE: It is important that the front panel controls of the receiver are not changed between the time the unknown and known signals are read. Due to the broadband characteristics of the CIG-25 output, the receiver circuits respond in an equal manner to both the unknown and known impulse signals. Thus the bandwidth of the receiver need not be considered as is the case when using a sine wave or CW calibration voltage as a transfer standard. Changes in receiver bandwidth at any frequency up to 1000 MHz can be measured by comparing the sine wave sensitivity of the receiver to its impulse sensitivity. Since the CIG-25 produces a flat noise spectrum to 1000 MHz, any change in sine wave sensitivity is an indication of a bandwidth change. This method permits bandwidth measurements with greater accuracy than is the case with conventional means. Due to the short pulse duration and low repetition rate of the CIG-25, it is necessary that a "peak" indicator be used in the receiver. This may be a peak reading VTVM, a slideback second detector, or an oscilloscope connected ahead of the second detector. (CIG25-5)

FIGURE 1 CIG-25 CORRECTION FACTOR CHART PAGE 6A (CIG25-6)