Solid State Relays 1-Phase, Zero Cross or Instant On Switching 25 AAC, 230 VAC with LED and Built-in Transil Types RF1A, RF1B

Similar documents
Solid State Relays 1-Phase, Soft Start Switching Types RGS1P..K..

2-pole solid state relays

Industrial, 2-Pole ZS Type RA2A

Solid State Relay. Zero Switching Types RGC Solid State Contactor 'U' Connection. Product Description RGC 1 A 60 A 40 K G U _.

Solid State Relays 1-Phase with Integrated Heatsink Soft Start Switching Types RGC1P..K..

2-pole solid state relays

1-Phase Integrated Heatsink Zero Cross or Instant On Switching

Solid State Relays Zero Switching Types Solid State Contactor

RP1A, RP1B. 1-phase PCB mount solid state relays. Main features. Description

Solid State Relays Zero Switching Types RGC Solid State Contactor 'U' Connection

RP1A, RP1B. 1-phase PCB mount solid state relays. Main features. Description

Solid-state Contactor Specifications

Solid State Relays 1-Phase Integrated Heatsink Zero Cross or Instant On Switching

Solid State Relays Zero Switching Types RGC Solid State Contactor 'E' Connection

Solid-state Contactor Specifications

Solid State Relays 1-Phase with Integrated Heatsink Proportional Switching Controllers Types RGC1P..AA.., RGC1P..V..

2PSS60A40 Solid State Relays 3-Phase with Integrated Heatsink

Solid State Relay. Zero Switching Types RGC Solid State Contactor 'E' Connection. Product Description RGC 1 A 60 A 30 K K E _.

Solid State Relays 3-Phase with Integrated Heatsink Types 2 & 3 Pole

Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink

Subject to changes 11/2003 Page 1/7

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60

NEW Series STH Output to 75A, 600 Vac High Industrial Performance (HIPpak) Solid-State Relays

Electronic timer CT-TGD.22

Type CP-S, CP-C & CP-A Switch mode

08/07/2015

Output Voltage* (nom.)(adjustable)

Solid State Relays 1-Phase, Proportional Switching Controllers Types RGS1P..AA.., RGS1P..V..

Solid State Relays 1-Phase with Integrated Heatsink Zero Cross or Instant On Switching Types RGC Solid State Contactor 'E' Connection

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

Features. Regulated Converter RAC05- SK/C14. RAC 5 Watt Single Output RAC05-3.3SK/C14. AC/DC Converter

Electronic timer CT-SDD.22

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Power supply CP-D 24/4.2 Primary switch mode power supply

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

Starting Torque Controller Technical Data

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT AC/DC Converter

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT12- AC/DC Converter

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Features. Regulated Converter. RAC10-K/ Watt 2 x 1 Single and Dual Output RAC10- K/277. AC/DC Converter

Solid State Relays SOLITRON MIDI Multi-Function Analog Switching Type RJ1P

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Features. Regulated Converters. RAC05-K 5 Watt 1 x 1 Single Output RAC05- SK. AC/DC Converter

Features. Regulated Converters. RAC01-C RAC02-C 1-2 Watt Single Output RAC0_- C. AC/DC Converter

Features. Switching Regulator. 2.0 Amp SIP3 Single Output R-78B-2.0 R-78B DC/DC Converter

Custom "Compact" range with display CD20 Custom Part number

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms

CB Scheme UL508 UL ATEX II3G

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

C B. Models. Models 2MOPP

Features. Regulated Converter. RAC04-C/277 4 Watt Single and Dual Output RAC04- C/277 -_. AC/DC Converter

Power supply CP-E 24/20.0

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Features. Regulated Converter. RAC05-K 5 Watt 1 x 1. Single Output RAC05- SK. AC/DC Converter

Three-phase monitoring relay CM-PVE

Electronic timer CT-SDS.22

Output Power Output Voltage (3) Output Current Total Regulation (2) Efficiency (5) Model Number (1,6) 8 W 3.3 VDC 2.50 A 7% 68% AEL15US03 (4) 12 W

Three-phase monitoring relays

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet

05/09/2012

Solid State Motor Contactor 3 Phase Motor Reversing Types REC2R

High precision measurement system for current and voltage IHC-A/B-RM01/03

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max.

Power supply CP-E 24/2.5

02/11/2015

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Three-phase monitoring relays CM-PFE and CM-PFE.2

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

Solid State Relays Industrial, 1-Phase ZS, Standard Range Types RA /RA /RA

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

02/11/2015

CP-T range Product group picture

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

Power supply CP-D 24/1.3

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

SOLID STATE RELAY RATINGS

RN Thyristor Controllers

celduc SILD Output : VAC 32A(*) Input : 3-32VDC - I<10mA Diagnostic : 30VDC - 100mA r e l a i s celpac P roud to serve you

Features. Regulated Converter. RAC02-SE/277 2 Watt Single Output RAC02- SE/277. AC/DC Converter

General. Environmental. EMC & Safety

Introduction EMC. Filter parameters. Definition of EMC / EMI. X-Capacitor. Sources of EMI. Coupling mechanism. Y-Capacitor.

celduc SIM Phase angle controller Output : VAC 40A(*) Input : Analog 0-10V r e l a i s celpac

Power supply CP-E 24/0.75

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

CP-E range Benefits and advantages

08/07/2015

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet

3.6. Control Relays and Timers D A M D 2. Contents. Product Overview. Catalog Number Selection. Solid-State Relays

Zelio Control Measurement Relays

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

Features. Regulated Converter. RAC05-K/277 5 Watt Single Output RAC05- SK/277/W. AC/DC Converter

Transcription:

Solid State Relays 1-Phase, Zero Cross or Instant On Switching 25 AAC, 230 VAC with LED and Built-in Transil Types RF1A, RF1B AC switching Solid State Relay Switching through back to back thyristors Long lifetime through reduced stress on output chip Operational ratings: up to 280 VAC, 25 AAC Control voltage: 5 VDC, 12 VDC, 24 VDC LED for control status indication Integrated overvoltage protection on output Opto isolation input to output 3750 VAC 0k cycles endurance test according to UL508 Pre-attached thermal interface to SSR backplate Product Description The RF1 series provides a compact solid state switching solution suited for confined spaces. Long life time is ensured by the use of assembly technology that reduces stresses on the power semiconductors. The RF1 series is suitable for resistive loads. The zero switching type (RF1A), switches ON when the voltage crosses zero. The instant-on type Specifications are stated at 25 C unless otherwise noted (RF1B), switches on when the control voltage is applied. Switch OFF occurs when current crosses zero. Integrated transils provide protection against overvoltages. A green LED indicates presence of the control voltage. FAS- TON terminals enable fast installation. The RF1 is provided with pre-attached thermal interface ready for mounting on chassis or heatsink. Ordering Key SSR series Number of switching poles Switching mode Rated operational voltage Control voltage Rated operational current Options RF 1 A 23 D 25 _ Ordering Key Switching mode Rated voltage Control voltage Rated current* RF1A: Zero Cross (ZC) 23: 230 VAC L: 5 VDC 25: 25 AAC RF1B: Instant On (IO) (24-280 VAC), M: 12 VDC 50/60 Hz D: 24 VDC Selection Guide Rated output voltage, Blocking voltage Control voltage Rated operational current* Switching mode range 230 VAC, ZC 600 Vp 4.25-9.0 VDC RF1A23L25 9.0-18.0 VDC RF1A23M25 18.0-28.8 VDC RF1A23D25 230 VAC, IO 600 Vp 4.5-9.0 VDC RF1B23L25 11.0-18.0 VDC RF1B23M25 18.0-28.8 VDC RF1B23D25 * Max. 25 AAC with suitable heatsink. Refer to Heatsink Selection tables. Specifications are subject to change without notice (23.06.2017) 1

General Specifications Latching voltage (across L-T) Operational frequency range Leakage current @ rated voltage Power factor Control input status 20 V 45 to 65 Hz < 3m AAC > 0.9 @ rated voltage continously ON Green LED, when control input is applied Rated impulse withstand voltage, U imp Isolation Input to Output Input & Output to Case 4 kv (1.2/50µs) for Overvoltage Category III 3750 Vrms 2500 Vrms Output Specifications Rated operational current* AC-51 (IEC/EN 60947-4-3, UL508) Minimum operational current Rep. overload current - UL508: T=40 C, ton=1s, toff=9s, 50 cycles Non-repetitive surge current (t=ms) 25 AAC 150 ma 40 AAC 325 Ap On state voltage drop I²t for fusing (t=ms) minimum Critical dv/dt @ Tj init = 40 C Endurance testing acc. to UL508 < 1.3 V 525 A²s 00 V/us 0,000 cycles * Max. 25 AAC with suitable heatsink. Refer to Heatsink Selection tables. Output Voltage Specifications Operational Voltage Range Blocking voltage Output protection 24-280 VAC 600 Vp Integrated transil Input specifications RF1..L RF1..M RF1..D Control voltage range RF1A 4.25-9.0 VDC 9.0-18.0 VDC 18.0-28.8 VDC RF1B 4.5-9.0 VDC 11.0-18.0 VDC 18.0-28.8 VDC Pick-up voltage RF1A 4.25 VDC 9.0 VDC 18.0 VDC RF1B 4.5 VDC 11.0 VDC 18.0 VDC Drop-out voltage 1.0 VDC 1.0 VDC 1.0 VDC Maximum Reverse voltage 9.0 VDC 18.0 VDC 28.8 VDC Max Response time pick-up RF1A 1/2 cycle 1/2 cycle 1/2 cycle RF1B 350 µs 350 µs 350 µs Response time drop-out RF1A 1/2 cycle 1/2 cycle 1/2 cycle RF1B 1/2 cycle 1/2 cycle 1/2 cycle Input current refer to diagrams below RF1..L RF1..M RF1..D Input current (madc) 20 18 16 14 12 8 6 4 RF1A23L25 RF1B23L25 4 4.5 5 5.5 6 6.5 7 7.5 8 8.5 9 Input voltage (VDC) Input current (madc) 14 12 8 6 4 RF1A23M25 RF1B23M25 8 9 11 12 13 14 15 16 17 18 Input voltage (VDC) Input current (madc) 14 RF1A23D25 12 RF1B23D25 8 6 4 18 19 20 21 22 23 24 25 26 27 28 29 Input voltage (VDC) 2 Specifications are subject to change without notice (23.06.2017)

Agency Approvals and Conformances Conformance IEC/EN 62314 IEC/EN 60947-4-3 Agency Approvals UR: UL508 Recognised, NRNT2 E80573 cur: CSA 22.2 No.14-, NRNT8 E80573 CSA: CSA 22.2 No.14-, 204075 VDE: DIN EN 60947-4-3 (VDE 0660-9) DIN EN 60335-1 ( VDE 0700-1) Electromagnetic Compatibility EMC Immunity IEC/EN 60947-4-3 Electrostatic Discharge (ESD) Immunity IEC/EN 600-4-2 Air discharge, 8 kv Performance Criteria 2 Contact, 4 kv Performance Criteria 2 Electrical Fast Transient (Burst) Immunity IEC/EN 600-4-4 Output: 2 kv, 5kHz Performance Criteria 2 Input: 1 kv, 5kHz Performance Criteria 2 Electrical Surge Immunity IEC/EN 600-4-5 Output, line to line, 1 kv Performance Criteria 1 Output, line to earth, 2 kv Performance Criteria 1 Input, line to line, 500 V Performance Criteria 1 Input, line to earth, 500 V Performance Criteria 1 Radiated Radio Frequency Immunity IEC/EN 600-4-3 V/m, 80-00 MHz Performance Criteria 1 V/m, 1.4-2 GHz Performance Criteria 1 3V/m, 2-2.7 GHz Performance Criteria 1 Conducted Radio Frequency IEC/EN 600-4-6 Immunity V/m, 0.15-80 MHz Performance Criteria 1 Voltage Dips Immunity IEC/EN 600-4-11 0% for 0.5/1 cycle Performance Criteria 2 40% for cycles Performance Criteria 2 70% for 250 cycles Performance Criteria 2 Voltage Interruptions Immunity IEC/EN 600-4-11 0% for 5000 ms Performance Criteria 2 EMC Emission IEC/EN 60947-4-3 Radio Interference Voltage Emission (Conducted) IEC/EN 55011 0.15-30MHz Class A (for currents >15 AAC a filter 0 nf/ 275 VAC/ X1 is needed for compliance) Radio Interference Field Emission (Radiated) IEC/EN 55011 30-00MHz Class B Note: Performance Criteria 1: No degradation of performance or loss of function is allowed when the product is operated as intended. Filter Connection Diagram Performance Criteria 2: During the test, degradation of performance or partial loss of function is allowed. However when the test is complete the product should return operating as intended by itself. 1Phase Performance Criteria 3: Temporary loss of function is allowed, provided the function can be restored by manual operation of the controls. L1 L1 T1 Control input lines must be installed together to maintain products' susceptability to Radio Frequency interference. Use of AC solid state relays may, according to the application and the load current, cause conducted radio interferences. Use of mains filters may be necessary for cases where the user must meet E.M.C requirements. The capacitor values given inside the filtering specification tables should be taken only as indications, the filter attenuation will depend on the final application. N SSR Specifications are subject to change without notice (23.06.2017) 3

Environmental and Housing Specifications RoHS (2011/65/EU) Pollution degree Impact resistance (EN50155, EN61373) Vibration resistance (2-0Hz, IEC60068-2-6, EN50155, EN61373) Weight Material Compliant 2 (non-conductive pollution with possibilities of condensation) 15/11 g/ms 2 g approx. 15 g approx. 2 g (box of pcs.) PA66, RAL7035 Relative humidity UL flammability rating (housing) Installation altitude 95% non-condensing @ 40 C UL 94 V0 0-00 m. Above 00 m derate linearly by 1% of FLC per 0 m up to a maximum of 2000 m GWIT & GWFI conforms to EN 60335-1 requirements Terminal Layout and Dimensions 1 / L1: Mains Connection 2 / T1: Load Connection 3 / A1(+): Control Signal 4 / A2(-): Ground All dimensions in mm Connection Specifications Functional Diagram SSR mounting screws M4 Terminal material CuEtp, Nickel plated copper Mounting torque 1.0Nm (8.85lb-in) Fastons pull out force* Connection type power: 1/L1, 2/T1 Connection type control: 3/A1+, 4/A2-130N Faston 6.35 x 0.8mm Faston 4.8 x 0.8mm 3/A1+ 4/A2- ZC IO 1/L1 2/T1 *Refer to Installation instructions 4 Specifications are subject to change without notice (23.06.2017)

Heatsink Selection Connection Diagram Load current [A] Thermal resistance [ C/W] Power dissipation [W] L1 25 2.5 1.9 1.3 0.8 0.3 -- -- 23.8 22.5 3.2 2.5 1.8 1.1 0.5 -- -- 20.9 20 4.1 3.2 2.4 1.6 0.9 0.2 -- 18.1 L2/N LOAD * 17.5 5.5 4.3 3.2 2.3 1.4 0.6 -- 15.4 15 7.5 5.9 4.4 3.2 2.1 1.0 0.1 12.9 12.5 8.4 6.4 4.6 3.1 1.7 0.5.4 16 12 9.3 6.8 4.7 2.8 1.2 8.1 7.5 -- -- 15 7.1 4.3 2.0 5.9 5 -- -- -- -- 13 7.5 3.4 3.8 2.5 -- -- -- -- -- -- 8.5 1.9 20 30 40 50 60 70 80 Note: These thermal resistance values are only applicable to the RF1 using the pre-attached thermal interface. TA Ambient temp [ C] *Depends on system requirements (- ) ( + ) Control Input Output Power Dissipation (PD) Thermal Specifications Power dissipation in W Power Dissipa on in W 25 20 15 Operating temperature Storage temperature Max. junction temperature, Tj Junction to heatsink thermal resistance, including pre-attached thermal interface, Rthjc Max. case temperature, Tc -30 C to 80 C (-22 to 176 F) -40 C to 0 C (-40 to 212 F) 0 C (212 F) 1.5 C/W Tj - (PD x Rthjc) See chart below 5 0 0 5 15 20 25 Load current in AACrms Load current in AACrms Max. Max. case Case temperature in in C C 0 95 90 85 80 75 70 65 60 0 2 4 6 8 12 14 16 18 20 22 24 26 Output Power power Dissipa on dissipation in Win W Duty cycle is considered to be 0% Short Circuit Protection, Co-ordination Type 2 Part No. Prospective short Mersen* Siba circuit current [karms] RF1..25 690 VAC, 25A gr x38 mm, 600 VAC, 25A grl x38 mm, FRGR69V25 60 034 34.25 * formerly Ferraz Shawmut Specifications are subject to change without notice (23.06.2017) 5

Installation 1. Peel off liner before mounting on heatsink. 2. Tighten screws alternately to max. 1.0Nm. 3. Insert / remove FASTON receptacle only with RF1 tightened to a surface. Packaging pcs. per box Weight per box, approx. 2 g Accessories Phase Change Thermal Pad Ordering Key RFHT Phase change thermal pad for RF1 Dimensions: 19mm x 17mm Packing quantity: pieces Heatsinks Ordering Key RHS5050RFD 3.5 C/W thermal resistance Dimensions: 80 x 50 x 51mm (Max. rating with mounted RF1 @ 40 C is 15 AAC) Panel Mounting Ordering Key RHS38ARFD 2.85 C/W thermal resistance Dimensions: 46 x 76 x 33mm (Max. rating with mounted RF1 @ 40 C is 16 AAC) Thru wall or Panel Mounting For specific details refer to the individual datasheet of each heatsink model. 6 Specifications are subject to change without notice (23.06.2017)